Make-Up Units
FILE NO: DATE: SUPERSEDES: DATE: 8-1 August 2010 8-1 July 2009
Pressurisation Series
2
Conventional heating systems are provided with a feed and expansion tank, normally positioned above the highest point in the system. This feeds the system with water, accommodates expansion and replaces losses due to evaporation. With this type of arrangement air is absorbed into the water with resultant corrosion of heat exchangers, pipework and boilers. A sealed system limits air intake and corrosion to a minimum and only needs fresh water make-up to replace any losses caused by leakage. The conventional header tank, with its housing, associated pipework and lagging, is dispensed with and atmospheric contamination is excluded. Higher flow temperatures may be used in sealed systems which, with larger temperature drops, permit lower water circulation rates, smaller pumps and reductions in pipework sizes, all with obvious cost-savings.
Glycol Auto-Fill
GLA 606 / 626
The glycol make-up unit has been rarely seen as a standard plant item. It has usually been provided as a custom-built product. GLA houses all the water/glycol make-up components in an enclosed unit with large storage capacity yet small footprint. Available with single or duty/standby pumps and an extensive options list for low and medium pressure systems containing glycol.
3750 Pulpress
Cabinet enclosed unit, specified for wall or floor mounting, providing control for low and medium pressure systems. Available in a wide range of specification levels with duty or duty/standby pumps. Microprocessor controlled with optional VFC interface and connection to BMS systems. Rotomould lightweight construction providing an environmentally friendly recyclable pressurisation solution.
3750 Pulpress
Typical Installations
4
Recommended installation of Armstrong Pressurisation make-up units and expansion vessels Wall mounted option*
Automatic Air Vent Cold Water Feed
3750 Pulpress Anti-Gravity Loop (2m min) Intermediate Vessel (if required) Expansion Vessel(s)
Drain Cock
Isolating Valve
Expansion Vessel(s)
3750 Pulpress
Drain Cock
Isolating Valve
Expansion Vessel(s)
GLA Unit
Drain Cock
Isolating Valve
Alternative Position
To Cooling Tower
Chillier Unit Condenser Mains Supply Pump Test Point System Fill Connection Electrical Safety Interlock Isolating Valve Non-Return Valve Drain Cock Lock Shield Valve
3750 Pulpress
Electrical Supply
Heating Load Flow Temperature Gauge Pump Safety Valve Pressure Gauge Return Auto-Air Vent with On-Off Clock Expansion Vessels Signals to BMS AntiGravity Loop
3750 Pulpress
Mains Supply Test Point System Fill Connection Electrical Safety Interlock Equipment within this area supplied by others
Boiler Controls
Isolating Valve
Non-Return Valve
Drain Cock
Warning Notes:
1. Packed-gland circulating pumps must NOT be used in sealed systems. 2. Water treatment must NOT be added to the system via the 3750 Pulpress break tank. 3. No part of the set, expansion vessel, intermediate vessel or connecting pipe is to be lagged. 4. Precautions should be taken to ensure that Lock Shield Valves are protected against unauthorised closure.
H
W D
Range
Model
Motor kW
rpm
Dimensions
1 1 1 1
6 6 6 6
8 8 8 8
/2 /2 /2 /2
/4 /4 /4 /4
1 1 1 1 3
6 8 6 8 8
25 25 26 26 26
/2 /2 /2 /2 /2
/2 /2 /2 /2 /2
1 1 1 1 1 1 1 1
560 902 560 902 560 902 560 902 560 902 560 902 560 902 560 902
42 55 42 55 42 55 42 55
/2 /2 /2 /2 /2 /2 /2 /2
/2 /2 /2 /2 /2 /2 /2 /2
3750-2SM 3750-1EL
W
1 1 1 1 3 3
8 8 10 10 10 10
600 1300 600 600 1300 600 600 1300 600 600 1300 600 600 1300 600 600 1300 600
65 70 65 70 65 70
/2 /2 /2 /2 /2 /2
/2 /2 /2 /2 /2 /2
GLA 626/M
All dimensions are in mm unless stated Dimensions for fully packaged units can be supplied upon request
Design Baseplate Cabinet Wall Mounted Floor Mounted Single System Two System Pump Dis. Iso Valves Pump Suct. Iso Pump Suction Strainer BS6281 Type A Air Gap BS1212 pt 3 Ball Valve Single Pump Duty/Standby Pumps Single Phase 220/240V Three Phase 380/415V Cold Fill 0-3 bar Cold Fill 3-6 bar Cold Fill 0-2.7 bar Cold Fill 2.7-5.5 bar Features Packaged Controls Pressure Switches Microprocessor Under Voltage Protection Door Interlocked Isolator Power On Lamp Pump Test Button Pump Run Lamp Pump Trip Lamp & Alarm Low Water Cut Out High Water Alarm Low Pressure Alarm High Pressure Alarm Excessive Demand Alarm Transducer Failure Alarm Audible Alarm Manual Reset of Alarm Automatic Reset Option H/O/Auto Switches Alternate Pump Start Hours Run Meter(s) Pump Frequency Alarm Delay Pump Start Service Due Indicator Modbus Connectivity to BMS BACnet Gateway LonWorks Gateway Glycol Auto Mix Volt Free Contacts Common High/Low Press. High Pressure Low Pressure Low Water Common High/Low Water Pump Run Pump Trip Pump Freq./Exces. Demand Power/Fuse Failure Common Alarm
Technical Summary
SPU 502 503 502 MPU 506 526 1SL 2SL 1SM 3750 2SM 1EL 2EL 1EM 2EM 606 GLA 626 606E 626E
O* O*
O* O*
O* O*
O* O*
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
4 bar max
All 3750 Pulpress units are attractively encased in a unique rotomoulded plastic enclosure. This enclosure is made of recyclable material giving it a lightweight environmentally-friendly design.
21 litre active capacity and manufactured from polyethylene complete with ball valve to BS1212 part 2 with type 'AB' air gap to comply with BS EN 13076:2003, WRAS (approval number: 0904058) and model water byelaws.
All pumps can be isolated for servicing. A non-return valve is fitted to each pump discharge, with an additional valve being fitted prior to the system connection.
Fabricated steel construction, complying with BS4814 and listed by the WRAS, either with a fixed or removable diaphragm. All vessels are suitable for maximum working pressures of up to 10 bar and are rated at 6 bar when BS4814 applies. Max water working temperature 100c (short period exposure). Max continuous water temperature 70c. Further information available upon request.
Specifications for MPU and GLA units can be supplied upon request
Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 8444 145 145 F: +44 (0) 8444 145 146
Pumps
Enclosures
Break Tank
Valves
Expansion Vessels
1. Static head of system above pressurisation unit. 2. Flow, return and ambient temperatures. 3. Total water content of system. 4. Percentage of antifreeze to system volume. 5. Maximum allowable pressure.
Our policy is one of continuous improvement and we reserve the right to alter our dimensions and specifications without notice
S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: 001 416 755 2291 F: 001 416 759 9101