Honeywell 5800pir Res Install Guide
Honeywell 5800pir Res Install Guide
Honeywell 5800pir Res Install Guide
1
LOCATION / EMPLACEMENT
No / Non / No Satisfactory / Satisfaisant / Satisfactorio
OPEN / OUVERTURE
1 2
See page GO Panasonic CR123A / SENSOR, CONDUCT GO / NO2 for ENROLL THE more information / Duracell DL123A / PERFORM WALK TEST TEST, AND See page 2 for Honeywell 466 more information
- Use only left OR right side corner mounting holes.
CONNECT THE BATTERY, ENROLL THE SENSOR, CONDUCT GO / NO GO TEST, AND PERFORM WALK TEST / METTRE LES PILES EN PLACE ,
MOUNT / INSTALLATION
1
TOP
ACCESSORIES / ACCESSOIRES
SMB-10 (P/N 0-000-110-01) SMB-10C (P/N 0-000-111-01) SMB-10T (P/N 0-000-155-01)
1 1
Swivel Mount Bracket Swivel Mount Ceiling Bracket Swivel Mount Bracket w/Tamper High Security Lens Kit Pet Alley Lens Kit
20' 0 6m 13' 4m
7' 2m
13' 4m
20' 6m
1 2
27' 8m
35' 11m
12
4 5 6 7 8 9 10
18
13 14
19
15 16 17
20
20' 6m
Side View / Vue de Cote
11
7'6" 0 (2.3m) 0
7' 2m
13' 4m
20' 6m
27' 8m
35' 11m
-1-
TROUBLESHOOTING
Problem: The system displays a low battery message. Solution: Replace the battery within 7 days.
SPECIFICATIONS
Power: Battery* (included). Battery Life, years (typical): RF Frequency: Operating Temperature: (for indoor use environment) Relative Humidity, no condensation: Detectable Walk Rate: Temperature Compensation:
1 x 3 V, Lithium; CR123A / DL 123A / 466 5 345 MHz 14 to 131 F (-10 to 55 C) 95% max. 0.7 7ft/Sec. (0.2 2.0m/Sec.) Advanced Dual Slope
LED INDICATIONS
Condition Power Up Walk Test Indicator LED Blinks once per second (for < 45 seconds) ON for 3 seconds = Loop 1 / Low Sensitivity Alarm Flickers rapidly for 3 seconds = walk test period ended
* Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212 F (100 C), or incinerate. Dispose of used batteries promptly. Keep away from children.
APPROVALS / LISTINGS
FCC part 15, Class B verified IC, ICES-003, Class B verified C-Tick CE SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. cETLus Listed COMPLIANCE NOTES Product must be tested at least once each year. Product must be installed within the protected area only.
WALK TESTING
The 10 minute walk test mode begins after power up, and can be restarted by removing and replacing the battery. As you walk through the detection pattern, the sensor LED will light for 3 seconds to indicate each alarm detection. Note: In walk test mode all transmissions will be sent as they occur. During normal operation, only one transmission sequence will occur within a 3-minute period to conserve battery life.
FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/television technician for help.
The user is cautioned that changes or modifications not expressly approved by Honeywell could void the users authority to operate this equipment. IC NOTICE: This Class B digital device complies with the Canadian ICES-003. Cet appareil numrique de la Classe B est conforme la norme NMB-003 du Canada. This device complies with RSS-210 of the IC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme la norme CNR-210 des rgles dIC. Lutilisation de ce dispositif est autorise seulement aux deux conditions suivantes ; (1) il ne doit pas produire de brouillage, et (2) lutilisateur du dispositif doit tre prt accepter tout brouillage radiolectrique reu, mme si ce brouillage est susceptible de compromettre le fonctionnement du dispositif.
To obtain applicable EU compliance Declaration of Conformity for this product, please refer to our Website, http://www.security.honeywell.com/hsce/international/index.html.
2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information.
800-04182&
P/N 800-04182 Rev A 8/09
-2-