ATS CTG White Paper
ATS CTG White Paper
ATS CTG White Paper
FEATURES
Ratings 40 to 3000 amps (2, 3 or 4 poles) UL 1008 listed at 480 VAC CSA certified at 600 VAC (200-225 amp 480 V) IEC listed at 480 V Double throw, mechanically interlocked contactor mechanism Electrically operated, mechanically held Designed for emergency and standby applications Available in standard open transition (CTG) or delayed transition (CTGD) models Ringing wave immunity per IEEE 472 (ANSI C37.90A) Conducted and Radiated Emissions per EN55022 Class B (CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3) ESD immunity test per EN61000-4-2 (Level 4) Radiated RF, electromagnetic field immunity test per EN61000-4-3 (ENV50140) 10v/m Electrical fast transient/burst immunity test per EN61000-4-4
Surge immunity test per EN61000-4-5 IEEE C62.41 (1.2 X 50 ms, 5 & 8 kV) Conducted immunity test per EN61000-4-6 (ENV50141) Voltage dips and interruption immunity EN61000-4-11 Seismic Compliance to IEEE-693-2005 and IBC-2003
LEXX0523-08
LEXX0523-08
NOTE: For applications requiring additional options or other configurations, see the CTS Series fully configurable transfer switch.
DIMENSIONAL SPECIFICATIONS
CTG & CTGD TRANSFER SWITCHES
MODEL AMP RATING POLES HEIGHT (A) NEMA 1 ENCLOSED WIDTH DEPTH (B) (C) REFERENCE FIGURE WEIGHT APPLICATION NOTES
40, 80, 100, 150 & 200 225 260 400 600 800 CTG 1000 1200 1600 2000 2600 3000
40, 80, 100, 150, 200 & 225
260 & 400 600 800 1000 CTGD 1200 1600 2000 2600 3000
LEXX0523-08
2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2, 3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4 2,3 4
24 (610) 24 (610) 46 (1168) 46 (1168) 46 (1168) 46 (1168) 46 (1168) 46 (1168) 66 (1686) 66 (1686) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 46 (1168) 46 (1168) 46 (1168) 46 (1168) 66 (1686) 66 (1686) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 74 (1880) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286) 90 (2286)
18 (457) 18 (457) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 40 (1016) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902) 35.5 (902)
11 (279) 11 (279) 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 14 (356) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 14 (356) 14 (356) 14 (356) 14 (356) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 19.5 (495) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219)
A A A A A A A A B B B B B B B B C C C C C C C C A A A A B B B B B B B B C C C C C C C C
69 (31) 69 (31) 69 (31) 75 (34) 114 (52) 125 (57) 168 (76) 180 (82) 97 (44) 224 (102) 460 (209) 490 (222) 475 (215) 560 (254) 475 (215) 560 (254) 1030 (467) 1180 (535) 1030 (467) 1180 (535) 1150 (522) 1400 (635) 1150 (522) 1400 (635) 127 (58) 133 (60) 176 (80) 188 (85) 221 (100) 230 (104) 475 (215) 560 (254) 475 (215) 560 (254) 475 (215) 560 (254) 1030 (467) 1180 (535) 1030 (467) 1180 (535) 1150 (522) 1400 (635) 1150 (522) 1400 (635)
1-6 1-5 1-5 1-5 1-5 &7 1-5 &7 1-5 &7 1-5 &7 1-5, 7&8 1-5, 7&8 1-5, 7&8 1-5, 7&8 1-5 1-5 1-5 & 7 1-5 & 7 1-5 & 7 1-5 & 7 1-5 & 7-8 1-5 & 7-8 1-5 & 7-8 1-5 & 7-8
Application Notes : 1. Dimensions are listed in inches (mm) and weights in pounds (kg). 2. Includes 1.25" door projection beyond base depth. Allow a minimum of 3" additional depth for projection of handle, light, switches, pushbuttons, etc. 3. All dimensions and weights are approximate and subject to change without notice and are not for construction use. 4. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc. 5. Special enclosures (NEMA 3R, 4, 4X, 12, etc.) dimensions may differ. Consult Caterpillar for details. 6. CTG 40-200 require larger 36" H X 24" W X 14" D enclosure depending on options specified. Consult Caterpillar for details. 7. Add 3" in height for lifting eyes. 8. Ventilation louvers on side/rear of 2600 and 3000A units require one side or rear of enclosure to be clear in order to afford proper airflow.
LEXX0523-08
TESTING STANDARDS
UL, CSA and IEC listed Ringing wave immunity Conducted and Radiated Emissions ESD immunity test Class B Radiated RF, electromagnetic field immunity test Electrical fast, transient / burst immunity test Surge immunity test Conducted immunity test Voltage dips and interruption immunity UL 1008, CSA 22.2 No. 178, IEC 947-6-1 IEEE 472 (ANSI C37.90A) EN55022 Class B (CISPR 11) (Exceeds EN55011 & MILSTD 461 Class 3) EN61000-4-2 (Level 4) EN61000-4-3 (ENV50140) 10v/m EN61000-4-4 EN61000-4-5 IEEE C62.41 EN61000-4-6 (ENV50141) EN61000-4-11
Switch Size (Amps) 40, 80 100, 150, 200 & 225 260 & 400 600 800, 1000, 1200 1600, 2000, 2600, 3000
*or 2 1/0 - 250 MCM may be used
LEXX0523-08
CTG Switch Ratings (Amps) 40, 80, 100, 150, 200, 225 260 400, 600 800 1000, 1200 1600, 2000, 2600, 3000
Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. www.Cat-ElectricPower.com LEXX0523-08 LEXX0523-08 (06-10)