Symmetra PX 96/160

Scalable from 16 kW to 160 kW Modular, scalable, high-efficiency power protection for data centers

High-performance, right-sized, three-phase power protection with industry-leading efficiency, availability, and performance for small and medium data centers or high-density zones
Modular and scalable without forced shutdowns High-efficiency double conversion technology (95%) Redundant power, runtime, and optional power distribution in a single unit High-density design Low total cost of ownership Unity power factor corrected Optional ultra-efficient, ultra-safe modular power distribution Rack-based for agility and aesthetics

Features and benefits


The right-sized UPS for demanding business-critical applications
The APC Symmetra PX 96/160 is a world-class, high-efficiency power protection system designed to costeffectively provide redundancy and high levels of availability while simplifying right-sizing of your data center. The Symmetra PX 96/160 kW UPS is a true modular system, made up of hot-swappable power, battery, intelligence, and bypass modules that facilitate easy installation and efficient service. This architecture can scale in increments of 16 kW up to 160 kW as demand grows or higher levels of availability are required in your data center. Designed exclusively for the Symmetra PX 96/160, the optional Integrated 160 kW Modular Power Distribution Unit combines a modular power distribution unit, battery cabinet, and maintenance bypass panel into a single enclosure, ensuring safe expansion of the power distribution system without hot work, without scheduling downtime, and without expanding the UPS footprint. The Symmetra PX 96/160 is built into standard APC NetShelter SX racks, aesthetically promoting quick installation and agility in a changing environment while minimizing the solution footprint to a mere 1.28 square meters for the Symmetra PX 96 kW or 1.92 square meters for the Symmetra PX 160 kW. The highly manageable Symmetra PX 96/160 features self-diagnostic capabilities, increasing overall data center reliability. Standardized, factory-assembled modules mitigate the risk of human error during installation or routine maintenance procedures. Suitable in small and medium data centers or high density zones of larger data centers, the Symmetra PX 96/160 delivers the efficient, modular, high-availability power protection that your business-critical applications require.

Symmetra PX 96/160 features


1 4 6

5 2 3

Symmetra PX 96/160
Availability
Hot-scalable 16 kW power modules Redundant intelligence module Hot-swappable power, battery, and intelligence modules Hot-swappable static bypass switch Self-diagnosing, field-replaceable modules Toolless module replacement Configurable alarm notifications StruxureWare Central compatible

Options
Integrated modular power distribution (36 poles) Additional modular power distribution (up to 72 poles) Line-up/remote extended runtime battery frames Secondary network management card (HTTP/Telnet/SNMP)

Total cost of ownership


TV-verified high efficiency (95% at 35% load) Unity power factor corrected Powerful, high-performance batteries

1 2

Dual mains input/output


Allows for top or bottom feed connection to two separate power inputs for increased availability

Typical applications
Small/medium data centers High-density zones of large data centers

High efficiency (95%) power module - down to 35% loading


Independently verified by TV, these highefficiency double conversion power modules reduce power and cooling costs, saving you money while delivering the optimal power protection your data center deserves

Hot-swappable battery module


Connected in parallel for increased availability, these hot-swappable battery modules feature advanced battery monitoring and temperaturecompensated battery charging that extends battery life, and hot swappability lowers the cost of replacement and mean time to repair (MTTR). Additional battery frames can be added for longer run times

Scalability
Adaptable 16 kW to 160 kW power capacity N+0 or N+1 module-level redundancy Extended battery runtime available

Support and service


Included: Start-up service Factory warranty Optional: Assembly Preventive maintenance On-site warranty extension Advantage plans

5 6

LCD display interface


Offers a clear text-based overview of alarms, status data, and system configuration options

Manageability
Dual mains input, top or bottom feed Embedded network management Remote access over HTTP, Telnet, SNMP Local access at PowerView display interface

Main intelligence module and redundant intelligence module


Automated predictive diagnostics expand your ability to monitor and control energy costs; back-up for the main intelligence module guarantees the maximum possible availability for your system

Premium line-up/remote external battery enclosure


A total of four enclosures can be connected to the UPS, allowing the UPS to be configured to your data center requirements while offering extended runtimes & availability

2 | Symmetra PX 96/160

3 | Symmetra PX 96/160

Symmetra PX 96/160 features, continued

The high-density, efficient, scalable, modular UPS


Energy efficiency
Independently verified by TV, the Symmetra PX 96/160 is 95% efficient to 35% loading, saving power and cooling costs and significantly reducing your overall total cost of ownership
Efficiency (%)
100 90 80 70 60 50 0 10 20 30 40 50 60 70 80 90 100

Energy use/efficiency APC Symmetra PX 160 kW 400 V, SY160K160H-PD

10

Load (%)
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output

Scalability and modularity

Sample configurations

7 8

Scalable from 16 kW to 160 kW Modular components simplify future expansion as your load grows N+1 redundant up to 144 kW Optional modular power distribution Hot swappable power and battery modules Hot-swappable breaker modules for UPS units with power distribution All components conform to NetShelter SX form-factor (H x W x D: 78.7 x 23.6 x 42.1 in, 1991 x 600 x 1070 mm) One-time installation service Note: To expand the system from 96 kW to 160 kW, the input power cabling must be sized for a Symmetra PX 160 kW at initial installation

Symmetra PX 96
1 power frame 1 battery frame Up to 6 power modules Up to 9 battery modules

Symmetra PX 160
1 power frame 2 battery frames Up to 10 power modules Up to 15 battery modules

Network management card


Provides UPS status and event notification. SmartSlot positions support dry contact, environmental monitor, building management system (Modbus/Jbus), and additional network management cards

High-density footprint
Protect power and provide runtime in a mere 1.28 square meters for the Symmetra PX 96 kW or 1.92 square meters for the Symmetra PX 160 kW. Integrate modular power distribution and maintenance bypass without changing the footprint, freeing valuable data center space for IT equipment

Built-in static bypass switch


The hot-swappable static bypass switch transfers the load to utility power without interruption in case of heavy overload or faulty conditions, and ensures that even in 125% overload conditions, the data center remains operational

10

Modular power distribution (optional)


Adapt the modular power distribution solution to meet changing demandwithout a forced shutdown. Monitor breaker positions and simplify power management with output metering and branch current/circuit monitoring

Symmetra PX 96 with power distribution


1 power frame 1 integrated power distribution, battery, and MBP frame Up to 6 power modules Up to 9 battery modules

Symmetra PX 160 with power distribution


1 power frame 1 battery frame 1 integrated power distribution, battery, and MBP frame Up to 10 power modules Up to 15 battery modules

4 | Symmetra PX 96/160

5 | Symmetra PX 96/160

The high-density, efficient, scalable, modular UPS


High-density and flexible configuration
Modular, energy-efficient design gives the Symmetra PX the highest power density in its class Frees up valuable data center space - Up to 96 kW in 1.28 square meters (battery footprint included) - Up to 160 kW in 1.92 sq. meters (battery footprint included) Integrated hot-scalable power, runtime, and distribution maximize solution density footprint Modular architecture simplifies installation by offering the flexibility that todays data centers require - Top feed, bottom feed - Single feed, dual feed
160 kW of protection in three NetShelter enclosures (1.92 m2)

Technical specifications: Symmetra PX 96/160


UPS rating kVA/kW (PF = 1)
Mains input (Normal operation)
Grid system Voltage range (full load) Frequency range Power factor (PF) I thd (full load) Nominal input current Maximum input current Maximum input short-circuit level Protection 3 phases + neutral + ground 340-477 V 40-70 Hz with 10 Hz/sec slew rate >0.99 @ load > 25% < 5% 155 A @ 380 V, 146 A @ 400 V, or 142 A @ 415 V (Continuous, at 340 V mains voltage) 175 A @ 380 V, 400 V, or 415 V 30 kA Backfeed contactor 3 phases + neutral + ground 340-477 V 40-70 Hz with 10 Hz/sec slew rate >0.99 @ load > 25% < 5% 256 A @ 380 V, 243 A @ 400 V, or 234 A @ 415 V (Continuous, at 340 V mains voltage) 290 A @ 380 V, 400 V, or 415 V 30 kA Backfeed contactor

96 kW

160 kW

Bypass input (Bypass operation)


Grid system Voltage (nominal) Voltage (range) Frequency (nominal) Frequency (range) Nominal input current Maximum overload input current 3 phases + neutral + ground 380 V / 400 V / 415 V +/-10% (from selected voltage) 50/60 Hz +/-0.1 Hz, +/-3 Hz, +/-10 Hz (user selectable) 147 A @ 380 V; 139 A @ 400 V; 134 A @ 415 V 184 A @ 380 V, 174 A @ 400 V, 167 @ 415 V 3 phases + neutral + ground 380 V / 400 V / 415 V +/-10% (from selected voltage) 50/60 Hz +/-0.1 Hz, +/-3 Hz, +/-10 Hz (user selectable) 243 A @ 380 V; 231 A @ 400 V; 223 A @ 415 V 304 A @ 380 V; 289 A @ 400 V; 279 A @ 415 V

Accessories
Extended runtime (XR) frames
To increase the number of minutes your load can remain on battery, add optional battery extended runtime frames. A maximum of four battery frames can be connected to the Symmetra PX 96/160 to extend runtime

Output Management cards


SmartSlot positions can be used to expand the monitoring capabilities of the UPS with these APC management cards: Network management card: One management card is included with the UPS; it enables you to monitor and control the UPS over the network. Optionally, install a second management card for redundancy Dry contact/environmental cards: Monitor the conditions of the UPS and its environment using external devices such as sensors
Power rating Grid system Voltage (nominal) Output current (nominal) Maximum battery operation time Frequency regulation Synchronized slew rate Overload (normal operation) Overload (battery operation) V thd Load PF 96 kW 3 phases + neutral + ground 380 V / 400 V / 415 V L-L 147 A @ 380 V; 139 A @ 400 V; 134 A @ 415 V Unlimited 50/60 Hz bypass synchronized, 50/60 Hz +/-0.1% free running Programmable to 0.25, 0.5, 1, 2, 4, 6 Hz/sec 150% for 60 seconds, 125% for 10 min, 100% continuous 150% for 60 seconds < 2% from 0 to 100% linear load, < 6% full non-linear load according to IEC/EN62040-3 from 0.5 leading to 0.5 lagging without any derating 160 kW 3 phases + neutral + ground 380 V / 400 V / 415 V L-L 243 A @ 380 V; 231 A @ 400 V; 223 A @ 415 V Unlimited 50/60 Hz bypass synchronized, 50/60 Hz +/-0.1% free running Programmable to 0.25, 0.5, 1, 2, 4, 6 Hz/sec 150% for 60 seconds, 125% for 10 min, 100% continuous 150% for 60 seconds < 2% from 0 to 100% linear load, < 6% full non-linear load according to IEC/EN62040-3 from 0.5 leading to 0.5 lagging without any derating

Modular power distribution


APC modular power distribution units eliminate the need to schedule downtime to add a breaker. Power distribution modules plug into a touch-safe backplane that shields users from dangerous amperage. The power distribution system simplifies power management by including output metering, branch current/circuit monitoring, and auto-detection by the StruxureWare suite of management options. Multiple power ratings and power cord lengths for low to high power guarantee compatibility and convenient installation

Building management system (Modbus/Jbus) card: Enable a building management system to monitor the UPS

Efficiency
Normal operation Battery operation 95% at 35% - 100% load; 90% @ 15% - 34% load 94% at 25% - 100% load; 90% @ 15% - 34% load 95% at 35% - 100% load; 90% @ 15% - 34% load 94% at 25% - 100% load; 90% @ 15% - 34% load

Preliminary Subject to change without notice

6 | Symmetra PX 96/160

7 | Symmetra PX 96/160

Technical specifications: Symmetra PX 96/160, continued


UPS rating kVA/kW (PF = 1)
Mechanical
Maximum dimensions (HxWxD) Net weight Shipping weight 1,991 x 1,200 x 1,070 mm 1,814 kg (3,991 lbs) 1,963 kg (4,319 lbs) 1,991 x 1,800 x 1,070 mm 2,806 kg (6,173 lbs) 3,037 kg (6,681 lbs)

96 kW

160 kW

Maximum module capacity


16 kW power modules Battery modules Power distribution modules 6 9 6 10 15 12

Regulatory compliance
CE, UL1778, EN/IEC62040-1-1, E/IEC/UL60950-1, EN50091-2 / IEC62040-2 (class A), FCC15A, EN/IEC62040-3

Preliminary Subject to change without notice

Technical specifications: 160 kW Modular PDU


Modular Power Distribution Unit (PDUM160H-B)
Output
Output voltage 230 V

Input
Voltage Load capacity Input mains Frequency Maximum input current 400 V 160 kVA Dual 40-70 Hz 295 A

Physical
Weight Shipping weight Dimensions (H x W x D) Shipping dimensions (H x W x D) 411 kg (906 lb) 444 kg (978 lb) 1991 x 600 x 1070 mm 2150 x 848 x 1210 mm

Preliminary Subject to change without notice

2011 Schneider Electric. All Rights Reserved. Schneider Electric, APC, Symmetra, NetShelter, StruxureWare, and Modbus are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. email: esupport@apc.com 132 Fairgrounds Road, West Kingston, RI 02892 USA 998-4749