Company name: Created by: Phone: Fax: Date:

Position Count Description

PFC Equipment Jeff Hasslen 763-425-7890 763-425-1132 3/1/12


Unit price

-1

MMS 8000 N

On request

Product photo could vary from the actual product

Product No.: 96530100 The motor is a 3-phase motor of the rewindable type with a sand shield, liquid-lubricated bearings and pressure-equalizing diaphragm. Liquid: Max liquid temperature at 0.15 m/sec: 104 F Technical: Shaft seal for motor: Materials: Motor:

SIC/SIC

Stainless steel DIN W.-Nr. 1.4401 AISI 316

Installation: Motor diameter: Electrical data: Motor type: Rated power - P2: Main frequency: Rated voltage: Voltage tolerance: Start. method: Service factor: Rated current: Starting current: Cos phi - power factor: Rated speed: Rated full-load torque: Locked-rotor torque: Breakdown torque: Moment of inertia: Enclosure class (IEC 34-5): Insulation class (IEC 85):

8 inch

MMS8000 123 HP 60 Hz 3 x 460 V +6/-10 % direct-on-line 1,15 194-186-186 A 600 % 0,88 3480 rpm 213.9 ft lb 190 % 310 % 1.571 lb ft 58 A

Printed from Grundfos CAPS [2012.01.058]

1/5

Company name: Created by: Phone: Fax: Date:


Position Count Description

PFC Equipment Jeff Hasslen 763-425-7890 763-425-1132 3/1/12


Unit price

Built-in temperature transmitter: No Windings: PE/PA

Others: Net weight: Shipping volume:

624 lb 8.44 ft

Printed from Grundfos CAPS [2012.01.058]

2/5

Company name: Created by: Phone: Fax: Date:


Description Product name: Product Number: EAN number: Technical: Shaft seal for motor: Materials: Motor: Value MMS 8000 N 96530100 5700397180594

PFC Equipment Jeff Hasslen 763-425-7890 763-425-1132 3/1/12

SIC/SIC

Stainless steel DIN W.-Nr. 1.4401 AISI 316

Installation: Motor diameter: Liquid: Max liquid temperature at 0.15 m/sec Electrical data: Motor type: Rated power - P2: Main frequency: Rated voltage: Voltage tolerance Start. method: Service factor: Rated current: Starting current Load current: Cos phi - power factor: Rated speed: Rated full-load torque: Locked-rotor torque: Breakdown torque: Moment of inertia: Axial load max: Enclosure class (IEC 34-5): Insulation class (IEC 85): Motor protection: Thermal protec: Built-in temperature transmitter R: Windings: Others: Net weight: Shipping volume:

8 inch

104 F

MMS8000 123 HP 60 Hz 3 x 460 V +6/-10 % direct-on-line 1,15 194-186-186 A 600 % 184 A 0,88 3480 rpm 213.9 ft lb 190 % 310 % 1.571 lb ft 11000 lb 58 A NONE external No 0,090 ohm PE/PA

127

38.1

45

192

68

152.5

45

45 18

L1 L2 L3 PE

624 lb 8.44 ft

M
3

Printed from Grundfos CAPS [2012.01.058]

72 "

101.6

W PE

3/5

Company name: Created by: Phone: Fax: Date:

PFC Equipment Jeff Hasslen 763-425-7890 763-425-1132 3/1/12

96530100 MMS 8000 N 60 Hz


cos phi eta 1 MMS 8000 N 123 HP 3* 460 V, 60 Hz, SF = 1.15 I (A) 200 I cos phi eta 0.8 160

0.6

120

0.4

80

0.2

40 P2 = 75 HP cos phi = 0.79 eta = 85.9 % I = 103 A 0 140 P2(HP) P1 (kW) n P1

0 0 n (rpm)

20

40

60

80

100

120

3200

120

2800

80

2400

40 P1 = 65.1 kW n = 3539 rpm 0

Printed from Grundfos CAPS [2012.01.058]

4/5

Company name: Created by: Phone: Fax: Date:

PFC Equipment Jeff Hasslen 763-425-7890 763-425-1132 3/1/12

96530100 MMS 8000 N 60 Hz


127 38.1

45

192

68

152.5

45

45 18

Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos CAPS [2012.01.058]

72 "

101.6

5/5