POWER TRIM

5 C
26345

PRESTOLITE POWER TRIM PUMP

INDEX

Table of Contents
Page Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-1 Valve Pressure Specifications . . . . . . . . . . . 5C-1 Electrical Specifications . . . . . . . . . . . . . . . . 5C-1 Lubricants/Sealers/Adhesives . . . . . . . . . . . . . . 5C-1 Special Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-2 Thermal Circuit Breaker Operation . . . . . . . . . 5C-2 Manual Release Valve Operation . . . . . . . . . . . 5C-2 Maintaining Power Trim Pump Oil Level . . . . . 5C-2 Air Bleeding Power Trim System . . . . . . . . . . . 5C-3 Bleeding OUT/UP Trim Circuit . . . . . . . . . . . 5C-3 Bleeding IN/DOWN Trim Circuit . . . . . . . . . 5C-3 Testing Power Trim Pump . . . . . . . . . . . . . . . . . 5C-4 Connecting Test Gauge . . . . . . . . . . . . . . . . 5C-4 Internal Restriction Test . . . . . . . . . . . . . . . . 5C-5 OUT/UP Pressure Test . . . . . . . . . . . . . . . . . 5C-5 IN/DOWN Pressure Test . . . . . . . . . . . . . . . . 5C-5 Trim Cylinder Internal Leak Test . . . . . . . . . . . . 5C-5 Trim Cylinder Shock Piston Test . . . . . . . . . . . . 5C-7 Motor and Electrical Bench Tests . . . . . . . . . . . 5C-7 Trim Pump Motor Test (In Boat) . . . . . . . . . 5C-7 Trim Pump Motor Test (Out of Boat) . . . . . . 5C-8 Solenoid Test (Pump in Boat) . . . . . . . . . . . 5C-9 Solenoid Test (Pump Out of Boat) . . . . . . . 5C-10 110 Amp Fuse Test (Pump in Boat) . . . . . 5C-11 110 Amp Fuse Test (Pump Out of Boat) . . . . . . . . . . . . . . . . . . 5C-12 20 Amp Fuse Test . . . . . . . . . . . . . . . . . . . . 5C-12 Page Trim Pump Removal . . . . . . . . . . . . . . . . . . . . . 5C-13 Hydraulic Repair . . . . . . . . . . . . . . . . . . . . . . . . 5C-13 Manual Release Valve Replacement . . . . 5C-13 Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . 5C-13 Valve Body and Gear Assembly . . . . . . . . 5C-14 Motor Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-15 Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . 5C-15 Armature Tests . . . . . . . . . . . . . . . . . . . . . . . 5C-17 Continuity Test . . . . . . . . . . . . . . . . . . . . . 5C-17 Test For Shorts . . . . . . . . . . . . . . . . . . . . 5C-17 Cleaning Commutator . . . . . . . . . . . . . . 5C-17 Field Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C-17 Test For Open Circuit . . . . . . . . . . . . . . . 5C-17 Test For Short In Field . . . . . . . . . . . . . . 5C-18 Thermal Switch Test . . . . . . . . . . . . . . . . . . 5C-18 Continuity Test . . . . . . . . . . . . . . . . . . . . . 5C-18 Brush Lead Tests . . . . . . . . . . . . . . . . . . . . . 5C-18 Brush Replacement . . . . . . . . . . . . . . . . . . . 5C-19 Brush Replacement . . . . . . . . . . . . . . . . 5C-19 End Cap And Brush Assembly Replacement . . . . . . . . . . . . . . . . . . . . . 5C-19 Reassembly . . . . . . . . . . . . . . . . . . . . . . . . . 5C-20 Trim Pump Installation . . . . . . . . . . . . . . . . . . . 5C-22 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . 5C-23

5C-0 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Identification
Some MerCruiser Sterndrives will be equipped with a Prestolite Power Trim pump. This pump was used interchangeably with the Oildyne pump for a period of time.

Specifications
Valve Pressure Specifications
Valve Up Circuit Down Circuit Pressure 2200 - 2600 PSl (15173 - 17932 kPa) 400 - 600 PSl (2759 - 4138 kPa)

Electrical Specifications
Pump Amperage Draw 115 Amps at 2200 - 2600 PSl (15173 - 17932 kPa)

Lubricants/Sealers/ Adhesives
Description
Power Trim and Steering Fluid 2-4-C Marine Lubricant Liquid Neoprene
50524

Part No.
92-90100A12 92-825407A2 92-25711-2

Prestolite Power Trim Pump

Special Tools
Description Test Gauge Kit Multi-Meter Torque Wrench (lb. ft.) Torque Wrench (lb. in.) Jumper Wire Part No. 91-52915A6 91-99750 91-36210 91-66274 Obtain Locally

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-1

Description
The Prestolite Power Trim Pump has internal valving that eliminates the need for an external reverse lock, as was required in the past. The pump generates a higher volume of fluid, but at a lower pressure than previous Prestolite pumps. This, in conjunction with large I.D. hydraulic hoses (gimbal housing to pump) and larger I.D. trim cylinders, should allow the drive unit to kick-up easier if an underwater object is struck.

Maintaining Power Trim Pump Oil Level


! CAUTION
Vent screw MUST BE backed out two (2) full turns (after bottoming out) to vent pump reservoir. FAILURE TO BACK SCREW OUT COULD RESULT IN DAMAGE TO PUMP. IMPORTANT: Check oil level with sterndrive unit in the full down position. IMPORTANT: SAE 10W-30 or 10W-40 engine oil can be used in system, if Quicksilver Power Trim and Steering Fluid is not available. 1. Place drive unit in the full IN/DOWN position. 2. Remove Fill screw from pump. Oil level should be up to bottom of the threads in Fill screw hole. If necessary, add Quicksilver Power Trim and Steering Fluid or SAE 10W-30 or 10W-40 motor oil (through Fill screw hole). NOTE: In tropical areas, single viscosity SAE 30 motor oil can be used.

! CAUTION
Due to differences in internal valving, the new Prestolite trim pump cannot be used to replace an earlier Prestolite pump, or vice-versa. Use of incorrect pump will affect trim operation and may cause damage to trim system. The pump motor is protected from overheating by an internal circuit breaker (on commutator end plate), that interrupts the current flow through the field windings in the event of an overheating condition. Electrical current overload protection is provided to the pump by a 110 amp fuse. Pump also is fitted with a 20 amp in-line fuse, which serves to protect the trim control and harness from an overload.

Thermal Circuit Breaker Operation


If the IN/DOWN or Trailer switch is kept depressed after drive unit reaches its end of travel, a thermal circuit breaker will open to prevent pump motor from overheating and pump motor will stop. Release switch(es) as soon as drive unit reaches end of travel, to prevent this from happening. If circuit breaker should open, allow motor to cool down and circuit breaker will automatically reset.

Manual Release Valve Operation


! WARNING
Before loosening manual release valve, make sure all persons are clear of sterndrive unit. In case of a Power Trim system malfunction, the sterndrive unit can be raised and lowered manually by turning the manual release valve counterclockwise approximately 3 turns and moving drive unit to desired position by hand. After drive unit has been placed in the desired position, close valve COMPLETELY. Power Trim system will not function properly, unless valve is completely closed.
5C-2 PRESTOLITE POWER TRIM PUMP 50524

a - Fill Screw b - Vent Screw c - Manual Release Valve

3. Raise and lower drive unit 6 to 10 times to purge any air from system; then, recheck oil level (with drive unit fully IN/DOWN) and add oil if necessary.
90-12934--2 1097

INDEX

Air Bleeding Power Trim System


The power Trim System will purge itself of a small amount of air by raising and lowering the drive unit several times. However, if a rebuilt trim cylinder is being installed (which has not been filled with oil), the following bleeding procedure should be used to remove the air from the system.

Bleeding IN/DOWN Trim Circuit


1. Ensure pump reservoir is filled to proper level. 2. Disconnect IN/DOWN hose from rear connection on gimbal housing hydraulic connector. If both cylinders were rebuilt, disconnect hoses from both sides of hydraulic connector. 3. Plug holes in hydraulic connector, using plug (22-38609) or suitable device. 4. Direct end of trim hose(s) into container. 5. Run trim pump in the UP direction until trim cylinders are fully extended. 6. Remove plug(s) from gimbal housing hydraulic connector and momentarily run trim pump in the IN/DOWN direction until a solid, air-free stream of fluid is expelled from rear hole(s) in hydraulic connector. Reconnect trim hose(s) and tighten securely. 7. Lower drive unit to the full IN/DOWN position and refill trim pump to proper level. Run trim system IN/DOWN and OUT/UP several times and recheck fluid level.

Bleeding OUT/UP Trim Circuit


1. Fill pump reservoir to proper level as explained preceding. (Trim cylinder must be compressed). 2. Disconnect OUT/UP hose from front connection on trim cylinder. If both cylinders were rebuilt, disconnect hoses from both cylinders. 3. Direct end of trim hose(s) into a container. 4. Run trim pump in the UP direction until a solid, airfree stream of fluid is expelled from hose(s). Reconnect hose(s) and tighten securely. 5. Refill trim pump to proper level.

22089 22089

a - OUT/UP Trim Hose b - Front Connection on Trim Cylinder

a - IN/DOWN Trim Hose b - Hydraulic Connector c - Plug (22-38609)

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-3

Testing Power Trim Pump


Connecting Test Gauge
1. Check trim pump oil level. Fill if necessary. 2. Place drive unit in the full IN/DOWN position. 3. Connect test gauge at the most convenient location (at pump or hydraulic connector).

22090

Gauge Connect to Hydraulic Connector


c - Caps d - Plugs
26344

Gauge Connected at Pump


a - Hydraulic Test Gauge 91-52915A6 b - Extension Hoses 91-52915A6 c - Fittings 22-77366

4. Open Valve A and B and run pump UP and DOWN several times (to purge air).

NOTE: Extension hoses MUST BE used to obtain accurate readings.

22126

a - Hydraulic Test Gauge (91-52915A6) b - Gimbal Housing Hydraulic Connector

5C-4 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Internal Restriction Test


1. Open valve A and B. 2. Run pump OUT/UP and IN/DOWN while observing gauge. 3. Replace adapter, if pressure is in excess of 200 psi (1379 kPa).

Trim Cylinder Internal Leak Test


IMPORTANT: The following test assumes that pump OUT/UP pressure is within specifications as determined by performing Power Trim Pump Test. 1. Reconnect trim cylinder hoses (if removed in previous test) as follows: a. Remove plugs and caps. b. Install UP hose to forward hole on hydraulic connector. Tighten securely. c. Install DOWN hose to aft hole on hydraulic connector. Tighten securely.

OUT/UP Pressure Test


1. Leave Valve A open and close Valve B. 2. Run pump OUT/UP while observing gauge. Reading should be 2200 - 2600 psi (15173 17932 kPa). If not, replace valve body and gear assembly. 3. Stop pumping OUT/UP. Pressure should not fall below 1900 psi (13104 kPa). If it does, check for and/or replace following: External oil leaks Valve Body and Gear Assembly

IN/DOWN Pressure Test


1. Close Valve A and open Valve B. 2. Run pump IN/DOWN while observing gauge. Reading should be 400 - 600 psi (2759 - 4138 kPa). If not, replace valve body and gear assembly. 3. Stop pumping IN/DOWN. Pressure should not fall below 350 psi (2410 kPa). If it does, check for and/or replace the following: External oil leaks Valve Body and Gear Assembly
22090

a - UP Hose b - DOWN Hose c - Hydraulic Connector

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-5

2. Connect gauge at most convenient location.

3. Open Valve Aand B and run pump OUT/UP and IN/DOWN; several times (to purge air). 4. Run pump OUT/UP until trim cylinders are fully extended; then, observe gauge while pumping. Pressure should be 2200 - 2600 psi (15173 17932 kPa). 5. Stop pumping OUT/UP. Pressure should not fall below 1900 psi (13104 kPa). If readings are not within specifications, an internal trim cylinder leak is indicated. Use the following procedure to locate faulty cylinder. a. If gauge is connected at pump, reconnect gauge at gimbal housing hydraulic connector. Repeat Step 2; then, run pump in OUT/ UP direction until trim cylinder are fully extended. b. Close Valve B on test gauge and repeat Steps 3 and 4.

26345

If Readings Are Now Within Specifications: Trim cylinder on the same side that test gauge is connected, is faulty. If Readings Are Still Not Within Specifications: Trim cylinder on the opposite side from where the test gauge is connected, is faulty.

Gauge Connected at Pump


a b c d e Hydraulic Test Gauge 91-52915A3 Fitting (22-77366) Fittings (Supplied with Gauge) Black Hydraulic Hose (From Gimbal Housing) Gray Hydraulic Hose (From Gimbal Housing)

22126

Gauge Connected to Hydraulic Connector


a - Test Gauge b - Coupling (Supplied with Gauge) c - Front Hydraulic Connector Port

5C-6 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Trim Cylinder Shock Piston Test


If trim system checks out good, but drive unit will not trim IN/DOWN, problem may be due to a leaky trim cylinder shock piston. Use the following test to check for this condition. Test gauge is not required. 1. Run pump in OUT/UP direction until trim cylinders are fully extended. 2. Prevent trim cylinder piston rods from retracting, using a suitable device. Quicksilver Trailering Kit works well for this purpose.

Motor and Electrical Bench Tests


Trim Pump Motor Test (In Boat)
! WARNING
DO NOT perform this test near fIammables (or explosives), as a spark may occur when making connections.

! WARNING
RemaIn clear of drive unit when performing power trim pump motor tests with pump in the boat and hydraulic hoses connected. 1. OUT/UP Operation: a. Connect a jumper wire between positive (+) solenoid terminal and BLUE/WHITE motor lead terminal. b. Motor should run.

22562

a - Trailering Clip

3. Disconnect UP trim hose from trim cylinders.

50523

22089

a b c d

OUT/UP Solenoid POSITIVE Terminal (+) BLUE/WHITE Motor Lead Terminal Jumper Wire

a - UP Trim Hose b - Front Connection

4. Run pump in IN/DOWN direction. If oil flows from UP port on trim cylinder, shock piston is leaking and must be replaced.
90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-7

2. IN/DOWN Operation: a. Connect a jumper wire between positive (+) solenoid terminal and GREEN/WHITE motor lead terminal. b. Motor should run.

3. OUT/UP Operation: a. Connect a 12 volt positive (+) supply lead to BLUE/WHITE motor lead terminal. b. Connect the negative (-) supply lead to a good ground on pump. c. Motor should run.

50523

a b c d

IN/DOWN Solenoid POSITIVE Terminal (+) GREEN/WHITE Motor Lead Terminal Jumper Wire

50523

a - OUT/UP Solenoid b - 12 Volt POSITIVE (+) Supply Lead c - NEGATIVE (-) Supply Lead

3. If motor does not run, refer to Motor Repair. See Table of Contents.

Trim Pump Motor Test (Out of Boat)


! WARNING
DO NOT perform this test near flammables (or explosives), as a spark may occur when making connections. 1. Remove trim pump from boat. Refer to Trim Pump Removal. See Table of Contents. 2. Remove fluid from trim pump reservoir.

5C-8 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

4. IN/DOWN Operation: a. Connect a 12 volt positive (+) supply lead to GREEN/WHITE motor lead terminal. b. Connect the negative (-) supply lead to a good ground on pump. c. Motor should run.

Solenoid Test (Pump in Boat)


! WARNING
DO NOT perform this test near flammables (or explosives), as a spark may occur when making connections.

! CAUTION
Remain clear of drive unit when performing power trim pump motor tests with pump in boat and hydraulic hose connected. 1. UP/OUT Solenoid: a. Connect jumper wire between positive (+) solenoid terminal and BLUE/WHITE harness wire terminal. b. Motor should run.

50524

a - IN/DOWN Solenoid b - 12 Volt POSITIVE (+) Supply Lead c - NEGATIVE (-) Supply Lead

NOTE: If motor does not run, refer to Motor Repair.

50521

a b c d

OUT/UP Solenoid Positive (+) Terminal BLUE/WHITE Harness Wire Terminal Jumper Wire

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-9

2. IN/DOWN Solenoid: a. Connect a jumper wire between positive (+) solenoid terminal and GREEN/WHITE harness wire terminal. b. Motor should run.

Solenoid Test (Pump Out of Boat)


! WARNING
DO NOT perform this test near flammables (or explosives), as a spark may occur when making connections. 1. Remove trim pump from boat. Refer to Trim Pump Removal. See Table of Contents. 2. Remove fluid from trim pump reservoir. 3. OUT/UP Solenoid: a. Connect 12 volt positive (+) supply lead to BLUE/WHITE harness wire terminal. b. Connect negative (-) supply lead to solenoid ground terminal. c. Connect ohmmeter leads to large terminals on solenoid.

50521

a b c d

IN/DOWN Solenoid Positive (+) Terminal GREEN/WHITE Harness Wire Terminal Jumper Wire

3. If motor does not run in one direction or another, replace appropriate solenoid. (See Wiring Diagram at end of this section for wire connection points).
50521

a b c d

OUT/UP Solenoid 12 Volt Positive (+) Supply Lead Negative (-) Supply Lead Ohmmeter Leads

4. Zero Ohms Reading (Full Continuity): Solenoid is OK. High Ohms Reading (No Continuity): Replace solenoid.

5C-10 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

5. IN/DOWN Solenoid: a. Connect 12 volt positive (+) supply lead to GREEN/WHITE harness wire terminal. b. Connect negative (-) supply lead to solenoid ground terminal. c. Connect ohmmeter leads to large terminals on solenoid.

2. Check for voltage at terminal 2, using volt meter. Voltage Indicated: Fuse OK. Voltage Not Indicated: Replace fuse.

50523

50521

a - Volt Meter Negative (-) Lead b - Volt Meter Positive (+) Lead c - Fuse

a b c d

IN/DOWN Solenoid 12 Volt Positive (+) Supply Lead Negative (-) Supply Lead Ohmmeter Leads

6. Zero Ohms Reading (Full Continuity): Solenoid is OK. High Ohms Reading (No Continuity): Replace solenoid. See Wiring Diagram at the end of this section for wiring connection points.

110 Amp Fuse Test (Pump in Boat)


! WARNING
DO NOT perform this test near flammables (or explosives), as a spark may occur when making connections. 1. Check for voltage at terminal 1 using a volt meter. Voltage MUST BE indicated before proceeding with next check.
50524

a - Volt Meter Negative (-) Lead b - Volt Meter Positive (+) Lead c - Fuse

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-11

110 Amp Fuse Test (Pump Out of Boat)


1. Connect ohmmeter leads between terminals on fuse. ZEro Ohms Reading (Full Continuity): Fuse OK HIGH OHMS READING (No Continuity): Replace fuse

20 Amp Fuse Test


1. Remove fuse from fuse holder.

50521

a - Fuse Holder

2. Connect ohmmeter; one lead to each end of fuse.


50524

a - 110 Amp Fuse b - Ohmmeter Leads

Zero Ohms Reading (Full Continuity): Fuse OK. HIGH OHMS READING (No Continuity): Replace fuse.

22497

a - 20 Amp Fuse b - Ohmmeter Leads

5C-12 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Trim Pump Removal


1. Disconnect trim pump battery leads from battery (negative lead first). 2. Disconnect trim harness connector (3 pronged) from trim pump. 3. Remove hydraulic hoses from trim pump. Cap end of hoses. 4. Remove lag bolts and washers, and lift pump and floor bracket from boat.

Hydraulic Repair
Manual Release Valve Replacement
NOTE: Replacement of manual release valve can be completed without removing the trim pump from boat.

! WARNING
Before loosening the manual release valve, make sure all people are clear of drive unit as drive unit will drop to full IN/DOWN position when valve is loosened. Slowly turn manual release valve counterclockwise to remove. To install new valve, turn valve clockwise until it seats.

50461

a - O-ring b - Rubber Seal

Disassembly
! CAUTION
50524

a b c d e

Positive Battery Lead Negative Battery Lead Harness Connector Black Hydraulic Hose (UP Hose) Gray Hydraulic Hose (DOWN Hose)

Work area must be dirt and lint free. The slightest amount of dirt in hydraulic system can cause pump malfunction. 1. Disconnect trim motor wires.

50520

a - BLUE/WHITE Motor Wire b - GREEN/WHITE Motor Wire c - BLACK Ground Wires

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-13

2. Remove mounting bolts and remove trim pump from floor bracket.

Valve Body and Gear Assembly


1. Place pump in a container to catch oil when valve body and gear assembly is removed. 2. Remove valve body, gear assembly and seal.

50522

50460

a - Screws (8) b - Valve Body And Gear Assembly

50522

a - Trim Pump b - Floor Bracket c - Mounting Bolts

3. Remove solenoids (if replacement is necessary).

50520

c - Seal

50520

a - UP Solenoid b - DOWN Solenoid c - Mounting Bolts (2 On Each Solenoid)

5C-14 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

3. Install new seal in reservoir.

5. Install valve body and gear assembly.

50520

a - Seal

4. Align motor shaft with gear assembly.


a - Screws (8) b - Valve Body And Gear Assembly c - New Seal (Not Seen)

50460

Motor Repair
Disassembly
1. Disconnect trim pump motor leads.

50522

a - Motor Shaft b - Gear Assembly

50459

a - Trim Pump Motor Leads b - Solenoids

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-15

2. Remove solenoid plate and connector and harness.

4. Remove motor assembly.

50459

a b c d e f

Solenoid Plate Nut Screws Solenoids Spacer Connector and Harness


26506

3. Remove valve body and gear assembly.

a b c d e f g h i

Nut And Washer (2) End Plate Assembly Field and Frame Assembly Armature Small Thrust Washer(s) Large Thrust Washer Spacer (1) Studs (2) Reservoir

50460

a - Screws (8) b - Valve Body And Gear Assembly c - Seal (Not Seen)

5C-16 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Armature Tests
CONTINUITY TEST

1. Clean commutator with 00 garnet grit sandpaper. DO NOT use emery paper. 2. Check gaps between commutator bars for material. Remove material if present.

1. Check armature for continuity. Set ohmmeter on Rx1 scale. Connect leads as shown. Continuity Indicated: Armature is grounded (replace armature). Continuity Not Indicated: Armature is OK.

50520

a - Commutator b - Gap
50461

a - Ohmmeter b - Meter Lead - Place On Armature Shaft c - Meter Lead - Place On All Commutator Bars (One At A Time)

Field Test
TEST FOR OPEN CIRCUIT 1. Set ohmmeter to Rx1 scale and connect meter leads between field leads. Zero Ohms Indicated (Full Continuity): Field OK. Zero Ohms Not Indicated (No Continuity): Replace field assembly.

TEST FOR SHORTS

1. Check armature on a growler (follow growler manufacturers instructions). Indication of a short requires replacement.
CLEANING COMMUTATOR

NOTE: If commutator is worn it can be turned down on a lathe or an armature conditioner tool.

50461

a - Ohmmeter b - Meter Leads - Connect Between Field Leads c - Field Leads

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-17

TEST FOR SHORT IN FIELD 1. Set ohmmeter on Rx1 scale. Connect ohmmeter between field brush lead and field frame. Zero Ohms Indicated (full continuity) - Short indicated (Replace field assembly). Zero Ohms Not Indicated (no continuity) - Field OK.

Brush Lead Tests


1. Set ohmmeter on Rx1 scale. Connect leads as shown. Test positive brush lead for ground. Continuity Indicated: Grounded condition; replace end plate assembly. No continuity: Brush lead OK.

50461

a b c d

Ohmmeter Meter Lead - Place On Positive Brush Holder Lead Meter Lead - Place On Frame Field Lead

50460

Thermal Switch Test


CONTINUITY TEST

a - Ohmmeter b - Meter Lead - Place On Positive Brush Lead c - Meter Lead - Place On End Cap

1. Test thermal circuit breaker for continuity, using ohmmeter set on Rx1 scale. Zero Ohms Indicated (Full Continuity): Thermal switch OK. Zero Ohms Not Indicated (No Continuity): Replace thermal switch.

2. Set ohmmeter on rx1 scale. Connect leads as shown. Test negative brush lead for an open condition. Continuity Indicated: Brush lead OK. Continuity NOT Indicated: Inspect lead for a poor connection.

26507

a - Place Meter Lead At This Point b - Place Meter Lead At Ground

50460

a b c d

Ohmmeter Meter Lead - Place On Negative Brush Lead Meter Lead - Place On End Cap Positive Brush Lead

5C-18 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

Brush Replacement
Inspect brushes and replace if: Pitted Chipped Brush is less than 1/4 in. (6mm) long Leads are fraying
BRUSH REPLACEMENT

END CAP AND BRUSH ASSEMBLY REPLACEMENT 1. Cut off field to positive brush holder lead as close to brush holder as possible. 2. Using 70-30 tin-lead alloy rosin core solder, solder field lead to brush holder on new end cap.

1. Cut brush leads off as close to brush holders as possible. 2. Using 70-30 tin-lead alloy rosin core solder, solder new brushes to brush holders.

50459

a - Field Lead b - Positive Brush Holder c - End Cap

26507

a - Brush Leads b - Brush Holders

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-19

Reassembly
1. Install armature and washers.

NOTE: Brush holder tool can be made as shown.

26507

3. Spread brushes with brush holder tool and install end plate over armature. Secure end cap with nuts and washers.

26506

a b c d e f g h

Large Washer Small Washer(s) Armature Reservoir Long Stud Sleeve (1) Small Stud Connector And Harness Holder a - End Plate

26507

2. Install field and frame assembly. Align index mark on field and frame assembly with mark on reservoir.

4. Ensure seal is in place in reservoir.

50459

50520

a - Index Marks - Align b - Field And Frame Assembly c - Reservoir


5C-20 PRESTOLITE POWER TRIM PUMP

a - Seal

INDEX

90-12934--2 1097

5. Align motor shaft with gear assembly.

7. Install solenoid plate and connector and harness.

50459

50522

a - Motor Shaft b - Gear Assembly

a b c d e f

Solenoid Plate Nut Screws Solenoids Spacer Connector And Harness

6. Install valve body and gear assembly.

8. Secure trim pump motor leads to solenoids.

50460

a - Screws (8) b - Valve Body and Gear Assembly c - New Seal (Not Seen)

50459

a b c d

Blue Lead - Connect to OUT/UP Solenoid Green Lead - Connect to IN/DOWN Solenoid OUT/UP Solenoid IN/DOWN Solenoid

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-21

9. Install trim pump on floor bracket. Tighten securely.

Trim Pump Installation


1. Secure pump and mounting bracket to boat using lag bolts and washers. 2. Reconnect trim hoses to pump. Black hose to left connection; gray hose to right connection. DO NOT cross-thread or overtighten hose fittings. Torque to 70 - 150 lb. in. (7.9 - 16.9 NSm). 3. Reconnect trim harness connector to trim pump. 4. Reconnect battery leads to battery. 5. Check fluid level and fill if necessary. (Refer to Maintaining Power Trim Pump Oil Level in this section.)

50522

50522

a - Trim Pump b - Floor Bracket c - Screws and Lock Washers

50524

a b c d e

Positive Battery Lead Negative Battery Lead Harness Connector Black Hydraulic Hose (UP Hose) Gray Hydraulic Hose (DOWN Hose)

5C-22 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097

90-12934--2 1097

INDEX

PRESTOLITE POWER TRIM PUMP - 5C-23

26347

Wiring Diagram

THIS PAGE IS INTENTIONALLY BLANK

5C-24 PRESTOLITE POWER TRIM PUMP

INDEX

90-12934--2 1097