Cryofuges
Cryofuges
Cryofuges
Large volume refrigerated centrifuges for practical work in blood banks and biotechnology.
Highest Versatility Swinging-bucket rotors for the Heraeus Cryofuge series centrifuges support a diverse array of sample processing applications without the need to modify existing protocols.
Our Heraeus Cryofuge centrifuges work with the Thermogenesis APX system to automatically separate cord blood into a freezing bag (for the mononuclear cell product), an erythrocyte bag and an excess plasma bag.
Convenient Operation The SEPACONTROL operating panel is systematically arranged, clearly displaying all functional areas and allowing easy access to operating parameters. Visual diagnostic indicators and acoustic signals supplement the information supplied by the microcomputer. This makes the centrifuge easy to use right from the start. The delay function permits users to delay system start-up.
Panel Five visual displays facilitate the identification of problems during centrifugation. When the lid is opened, the rotor is unevenly balanced. In the event of a system error, programming error, or if the temperature limit has been exceeded, an LED signals a warning. Memory Control 33 memory locations are available to save run parameters for future use. New programs generated using the function panel can be immediately added to the library.
Status The status field is systematically arranged into the following areas: start-up and braking curves, speed and rotor data, time and temperature. LEDs prevent the user from confusing the values on the display. Software for Sample Tracking Heranet software allows users to document centrifugation in blood banks. The software saves actual and set values and processes information which is entered at the centrifuge, using a barcode reader.
Easy Opening and Closing The robust, automated lid-lock mechanism protects operators and makes lid openings and closures effortless.
Easy Set-Up, Programming and Monitoring An intuitive operator keypad allows you to recall protocols at the touch of a button. Only five keys are required for completely programming all parameters.
Easy User Access Front panel controls allow users to start, stop and open the lid of the centrifuge. Whisper-Quiet Operation A noise level under 58 dBA provides the lab with a more comfortable working environment.
Energy-Efficient Performance Energy-saving design increases refrigeration efficiency and minimizes heat output, ensuring a more comfortable working environment.
Technical data Operation with blood packs No. of pack systems/bucket Polyamide plastic inserts: Order no. M2) Opening M (mm) Order no. L1) Opening L (mm) Order no. XL3) Opening XL (mm) Order no. XXL4) Opening XXL (mm) double-quint 2 76007667 110 x 57 76007647 110 x 70 76007657 110 x 76 76007677 110 x 88
* At ambient temp. of 25 C M, L and XL plastic inserts come complete with balancing weights 75007645. One set of balancing weights includes 4 weights of 6 and 15 g each. Balancing plates 75005759 can be used to compensate big weight differences. One set includes 2 plates at 35 and 65 g each. The balancing insert 75007668 consists of an XL plastic insert, 2 balancing weights and 30 balancing plates, enabling compensation of up to a full bucket load. 1) Suitable for triple and quad systems. 2) Suitable for double systems. 3) Suitable for quad systems, systems with soft filters. 4) Suitable for quad and quintuple systems, systems with filters..
Ordering Information Additional Accessories for Blood Pack Operation 75006681 75005759 75015638 12 rubber volume compensation plates 4 rubber balancing plates Hook adapter for Cord Blood Seperations (max RCF 1,328xg)
1) Make sure that the bucket swings out correctly when all places are used. Type of tube: ML = microlitre tube; B. Coll. = blood collection tube; Con = disposable conical tube; Oil test = oil test tube, pear shaped; Univ. = universal container (with vertical edge, disposable conical type). Standard tube: a) 1.5 ml microlitre tubes, b) borosilicate glass, c) 12 ml Nunc.-screw cap tube, d) oil test tube, pear shaped, e) 50 ml disposable conical screw cap tube. Adaptors can be used with tubes with the following shape bottom: F = flat, R = round, C = conical, S = special
Round Bucket
Ordering Information Model Cat. No. Max. speed (rpm) Max. RCF (x g) Max. capacity Max. perm. mass (g) Min. temp. at max. RCF* Max. acceleration time (s) Min. braking time (s) Radius (cm)
*At ambient temp. of 25 C Aerosol tight cap (order no. 75008081) available on request.
Heraeus Cryofuge 8500i 75008165 5,050 8,525 1 x 1000 ml 3,200 +8 C 190 220 29.9
Nominal volume of tube: Bp. = blood pack, Type of tube: Div. = diverse, Corni. = Corning bottle, H = Heraeus tube, HST = Heraeus stainless steel tube Standard tube: b) borosilicate glass. 2) Additional pad for conical tubes required from manufacturer, 3) Only use without cap 75008081, 4) Pad 75001808 required, 6) Pad 75001913 required, 7) max. speed 2,600 rpm Adaptors can be used with tubes with the following shape bottom: F = flat, R = round, C = conical, S = special
Type of tube: ML = microlitre tube; B. Coll. = blood collection tube, Con = disposable conical tube Standard tube: a) microlitre tubes, b) borosilicate glass, c) 15 ml disposable conical screw cap tube, e) 50 ml disposable conical screw cap tube. Adaptors can be used with tubes with the following shape bottom: F = flat, R = round, C = conical.
Temperature control range Safety features Design Dimensions (hxwxd) Weight (excl. rotor) Power consumption Refrigeration unit Recommended fuse Designed and tested in acc. with
Ordering Information Electrical Configuration 220 V, 50 Hz, Single Phase 230 V, 50 Hz, Single Phase 400 V, 50 Hz, 3 phase 220 V, 60 Hz, Single Phase GMP model* 400 V, 50 Hz, 3 phase with built-in refrigeration unit 400 V, 50 Hz, 3 phase for external refrigeration unit Heraeus Cryofuge 6000i 75007520 75007526 75007521 75007528 75007562 75007566 Heraeus Cryofuge 8500i 75007550
75007561
* external refrigeration unit required when operating a GMP unit (part number 75015709
Protecting Your Investment Centrifuge rotor maintenance is critical to the safety of your lab. We offer rotor safety seminars and rotor inspection clinics to ensure the longevity of your investment, and the safety of your workplace. If you would like to learn more about hosting a clinic at your facility or taking part in one at one of our facilities, please contact your local representative for further information.
2008 Thermo Fisher Scientific Inc. All rights reserved. Hitachi is a registered trade mark of Hitachi Koki Co., Ltd. Corning is a registered trademark of Corning, Inc. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
North America: USA/Canada +1 866 984 3766 www.thermo.com/centrifuge Europe: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, France +33 2 2803 2000, Germany national toll free 08001-536 376, Germany international +49 6184 90 6940, Italy +39 02 02 95059 434-254, Netherlands +31 76 571 4440, Nordic countries +358 9 329 100, Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203 Asia: China +86 21 6865 4588 or +86 10 8419 3588, India +91 22 6716 2200, Japan +81 45 453 9220, Other Asian countries +852 2885 4613 BRO-LECF-CRYO-0108 Countries not listed: +49 6184 90 6940 or +33 2 2803 2000