1/8 Solenoid Operated Directional Valves, DSG-01 Series
These are Solenoid Operated Directional Valves of high pressure, high
flow and low pressure drop, the features of which can be materialized
by employing a powerful wet type solenoid and the rational flow
channel design.
High Pressure & High Flow Rate
In comparison to our existing lines, both the pressure and flow of
these valves are much increased.
Max. Operating Pressure: approx. 10 % increased [31.535 MPa
(4570 5080 PSI)]
Terminal Box Type
Max. T-Line Back Pressure: approx. 30 % increased [1621 MPa
(2320 3050 PSI)]
Max. Flow Rate: approx. 60 % increased [63100 L/min (16.64
26.42 U.S.GPM)]
Low Pressure Drop
The pressure drop of these valves is reduced by 10 % from 1.0 to 0.9
MPa (145 to 131 PSI), in comparison to our existing lines*; the valves
effectively reduce the energy consumption of the unit.
{* At Flow Rate: 60 L/min (15.9 U.S.GPM), Spool Type: 3C2 (PA)}
Compact & Small Mass
Despite of high pressure, high flow and low pressure drop, these valve
Plug-in Connector Type
bodies are compact and lightweight with DC double solenoids; the
overall length and mass are reduced from 210 to 205 mm (8.26 to 8.07
inch) and from 2.2 to 1.85 kg (4.85 to 4.08 lbs), respectively.
Shockless type available
In addition to the standard valves for high pressure and high flow, a
shockless type capable of minimizing noise and vibration in piping
during spool changeover is also available.
Stable Operation
Due to the powerful magnetic and spring force of the solenoids, these
valves exhibit a high tolerance to contaminants and especially stable
operation.
IP65-equivalent high dust- and water-proof
These valves demonstrate excellent dust- and water-proof
characteristics, in compliance with I. E. C. Pub. 529. IP65 and JIS C
0920 IP65 (dust- and jet-proof type).
Usable in products of various standards
These standard valves are CE certified for installation in equipment overseas.
UL/CSA certified products are also available.
Specifications
Valve Type
Model Numbers
Max. Flow 2
L/min
(U.S.GPM)
Max. Operating
Pressure
MPa (PSI)
Max. T-Line
Back Pressure
MPa (PSI)
100
(26.4)
35
(5080)
21
(3050)
DSG-01-3C - -70/7090
Standard Type
DSG-01-2D2- -70/7090
DSG-01-2B - -70/7090
Shockless Type
S-DSG-01-3C - -70/7090
S-DSG-01-2B2- -70/7090
Max. Changeover
Frequency
Cycle/min {min1}
Mass
kg
(lbs.)
300
R Type Sol. Only
120
1.85
(4.08)
63
(16.6)
25
(3630)
21
(3050)
120
40
(10.6)
16
(2320)
16
(2320)
300
R Type Sol. Only
120
1.4(3.09)
1.85(4.08)
1.4(3.09)
L-DSG-01-3C - -70/7090
Low Wattage(14W)
Type 1
L-DSG-01-2D2- -70/7090
L-DSG-01-2N - -70/7090
L-DSG-01-2B
- -70/7090
1.85
(4.08)
1.4(3.09)
1. For details of L-DSG-01, please contact us.
2. Maximum flow indicates a ceiling flow depends on the type of spool and operating condition, refer to the List of Spool Functions on pages 347
to 351 for details.
344
DSG-01 Series Solenoid Operated Directional Valves
DIRECTIONAL CONTROLS
Sub-plate
Piping
Size
Japanese Standard "JIS "
Sub-plat e
Model Numbers
Thread
Size
European Design Standard
Sub-plat e
Model Numbers
N.American Design Standard
Thread
Size
Sub-plat e
Model Numbers
Approx.
Mass
kg (lbs.)
Thread
Size
1/8
DSGM-01-31
Rc 1/8
DSGM-01-3180
1/8 BSP. F
DSGM-01-3190
1/8 NPT
0.8 (1.8 )
1/4
DSGM-01X-31
Rc 1/4
DSGM-01X-3180
1/4 BSP. F
DSGM-01X-3190
1/4 NPT
0.8 (1.8 )
3/8
DSGM-01Y-31
Rc 3/8
DSGM-01Y-3190
3/8 NPT
0.8 (1.8 )
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
Mounting Bolt
For socket head cap screws in the table below are included.
Descriptions
Soc. Hd. Cap Screw (4 pcs.)
Tightening Torque
Japanese Standard "JIS"
European Design Standard
M5 45 Lg.
N. American Design Standard
No. 10-24 UNC 1-3/4 Lg .
5 - 7 Nm (43 - 60 in. 1bs.)
Applicable to working pressure more than
25 MPa (3630 PSI): 6 - 7 Nm (52 - 60 in. 1bs.)
Valve Type
Coil
Type
Electric source
Frequency
(Hz)
50
A100
Standard
Type
AC
A120
A200
A240
Shockless
Type
DC (K Series )
AC DC Rectified (R )
D12
D24
D48
R100
R200
60
50
60
50
60
50
60
50/60
Voltage (V)
Source Ratin g
100
100
110
120
200
200
220
240
12
24
48
100
200
Serviceable Range
80 - 110
90 - 120
96 - 132
108 - 144
160 - 220
180 - 240
192
216
10.8
21.6
43.2
90
180
264
288
13.2
26.4
52.8
110
220
Current & Power at Rated Voltage
Inrush (A) 2 Holding (A)
Power (W)
2.42
0.51
2.14
0.37
2.35
0.44
2.02
0.42
1.78
0.31
1.21
0.25
1.07
0.19
1.18
0.22
1.01
0.21
0.89
0.15
2.45
1.23
29
0.61
0.33
29
0.16
DSG-01 Series Solenoid
Operated Directional Valves
Solenoid Ratings
1. AC solenoid is not available in shockless type.
R type models with built-in current rectifier is recommended for shockless operation with AC power.
2. Inrush current in the above table show rms values at maximum stroke.
3. There are more coil types other than the above. For details, please make inquiries.
The coil type numbers in the shaded column are handled as opotinal extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
Options
Push Button with Lock Nut
Can be used for manual changeover of spool. The push button
can be locked in the pressed condition.
Lock Nut
SOL b
Push Button
Plug-in Connector with Solenoid Indicator Light
These are the indicator light incorporated plug-in connector
type solenoids. Energisation or de-energisation of the solenoid
can be easily identified with the incorporated indicator light.
Plug-in Connector
With Indicator Light
SOL b
DSG-01 Series Solenoid Operated Directional Valves
345
Model Number Designation
FSpecial
Seals
SShockless
Type
- 01
DSG
Series
Number
Valve
Size
-2
Number
of Valve
Positions
3:
Three
Positions
B
SpoolSpring
Arrangement
C:
Spring
Centred
2
Spool
Type
-D24
Special Two
Position Valve
Omit if not
required
2, 3
4, 40
60, 9
10, 11
12
Coil
Type
-C
Manual
Override
-N
Electrical
Conduit
Connection
-70
-L
Design
Number
Models with
Reverse Mtg. of
Solenoid
Omit if not
required
None:
Japanese
Std. "JIS"
AC:
A100
A120
A200
A240
Design
Standard
None:
Manual
Override
Pin
None:
Terminal
Box Type
90:
N.American
Design Std.
DC:
None:
Standard
Type
F:
For Phosphate
Ester Type
Fluids
(Omit if not
required
D:
No-Spring
Detented
DSG:
Solenoid
Operated
Directional
Valve
01
2:
Two
Positions
R:
B:
Spring
Offset
S:
Shockless
Type
D12
D24
D48
3:
Three
Positions
C:
Spring
Centred
2:
Two
Positions
B:
Spring
Offset
2
3
8
2
4
A
B
1
1
(AC
DC)
R100
R200
DC:
D12
D24
D48
C:
Push
Button
and
Lock Nut
(Option)
70
N:
Plug-in
Connector
Type
2
N1 :
Plug-in
Connector
Type
with
Indicator
Light
(Option)
R:
(AC
DC)
R100
R200
1. In case of the special two position valve, please refer to page 352 for details.
2. N1 is not available for R type solenoids.
In the table above, the symbols or numbers highlighted with shade represent the optional
extras. The valves with model number having such optional extras are handles as options,
therefore, please confirm the time of delivery with us before ordering.
346
DSG-01 Series Solenoid Operated Directional Valves
None:
Japanese
Std. "JIS"
and
European
Design
Std.
90:
N. American
Design
Std.
DIRECTIONAL CONTROLS
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01-
-A
L /min
[Port "B" Blocked]
Model
Numbers
Graphic
Symbols
10
DSG013C2
b
PT
AB
DSG013C3
b
PT
AB
DSG013C4
DSG013C40
b
PT
AB
Spring Centred
Working Pressure MPa
A B
Three Positions
b
PT
AB
DSG013C60
a
PT
16
25
31. 5
100
100
100
Working Pressure MPa
Working Pressure MPa
35
10
16
25
1004310041 8021
5738 5331 2917
1008010080100801007710077 7046 7046 7046
9063 9063 9063 9063 9063 4530 4530 4530
90 9022 3518 10038 7628 6715
90
90
9026 4314 3011 5031 3820 2010
85 8040 8022 8540 8535 8524
85
85
80
80 8030 6315 2510 7026 5024 3216
4323 4323 4223 4223 4223 5432 5432 5232
4023 4023 3823 3623 3523 4830 4730 4730
100
[Port "A" Blocked]
100
31. 5
6017
1910
7046
4530
5710
167
6016
2213
5232
4730
35
10
16
25
3815 1004310041 8021
139 5738 5331 2917
7046 7046 7046 7046
4530 4530 4530 4530
357 10038 7628 6715
125 5031 3820 2010
5512 8540 8535 8524
1810 7026 5024 3216
5232 5432 5432 5232
4730 4830 4730 4730
31. 5
35
6017
1910
7046
4530
5710
167
6016
2213
5232
4730
3815
139
7046
4530
357
125
5512
1810
5232
4730
10
AB
DSG013C9
100
100
100
100
100
100
100
100
20
10
15
10
20
10
15
PT
AB
DSG013C10
a
PT
AB
DSG013C11
a
PT
AB
DSG013C12
No-Spring
Detented
DSG012D2
80
80
80
80
80
45
6213
1510
6027
3518
6213
1510
5045 5042 4540 4540
4521 4516 3813
AB
50
45
PT
5045 5042 4540 4540
3618 2813 2212
AB
Spring Offset
Two Positions
PT
100 100631003310027100501003710020 7816 6213 100501003710020 7816
10070 8020 7020 4019 10037 5525 2914 2011 1510 10037 5525 2914 2011
10065 8552 7245 6534
5
13
10
20
23
100
100
100
100
7050 5740 5025 4319
100 100631003310027100501003710020 7816 6213 100501003710020 7816
10070 8020 7020 4019 10037 5525 2914 2011 1510 10037 5525 2914 2011
DSG012B2
85
85
85
85
85
20
16
16
15
13
70
70
70
70
70
50
50
50
50
50
26
17
13
11
10
PT
AB
DSG012B3
PT
AB
DSG012B8
PT
8563
8530
8070
7048
8050
3520
8050
6033
8070
7048
7040
2315
6340
5028
8070
7048
6020
158
4432
4028
8070
7048
4510
105
E
DSG-01 Series Solenoid
Operated Directional Valves
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
4432
4028
8070
7048
3010
75
Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
( Example )
50 Hz, At minimum serviceable voltage
(80% of rated voltage)
50 Hz, At rated voltage
The maximum flow rate is constant
regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
60 Hz, At rated voltage
2. For the maximum flow rate in P T of the valves with a
100
100 (43)
57 (38)
60 Hz, At minimum serviceable voltage
(90% of rated voltage)
mark, please see page 351.
The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.
DSG-01 Series Solenoid Operated Directional Valves
347
List of Standard Models and The Maximum Flow
Models with DC or R Type Solenoids: DSG-01-
-D /R
L /mi
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
[Port "B" Blocked]
Model
Numbers
Graphic
Symbols
Working Pressure MPa
10
16
25
31. 5
35
100
100
100
100
100
100
80
100
80
90
90
85
85
50
41
50
41
100
80
90
42
65
45
50
41
100
80
50
26
40
30
50
41
100
100
100
85
85
100
AB
a
PT
a
Spring Centred
Three Positions
DSG013C60
a
PT
Working Pressure MPa
35
10
16
25
31. 5
35
100
80
38
20
33
26
50
41
100
55
78
70
100
62
85
65
66
58
45
35
78
70
58
48
52
36
66
58
28
23
78
70
38
30
30
25
66
58
25
19
78
70
31
25
26
21
66
58
22
17
75
70
29
23
24
19
66
58
100
55
78
70
100
62
85
65
66
58
45
35
78
70
58
48
52
36
66
58
28
23
78
70
38
30
30
25
66
58
25
19
78
70
31
25
26
21
66
58
22
17
75
70
29
23
24
19
66
58
100
100
20
15
10
10
20
15
10
10
85
35
80
23
40
20
100
74
56
43
36
28
28
20
24
19
100
100
100
100
23
20
13
10
85
85
85
35
80
23
40
20
100
74
56
43
36
28
28
20
24
19
100
74
100
85
100
74
56
43
60
46
56
43
36
28
40
32
36
28
28
20
36
28
28
20
24
19
32
24
24
19
75
75
75
75
75
40
30
27
50
50
45
45
45
42
40
40
31
23
75
65
35
30
24
19
75
65
23
17
22
18
75
65
19
13
22
18
75
65
17
12
PT
AB
31. 5
AB
a
25
PT
DSG013C40
16
AB
DSG013C4
10
PT
DSG013C3
Working Pressure MPa
A B
DSG013C2
[Port "A" Blocked]
AB
DSG013C9
a
PT
AB
DSG013C10
a
PT
AB
DSG013C11
a
PT
AB
DSG013C12
No-Spring
Detented
DSG012D2
AB
45
50
45
PT
30
25
22
16
16
15
13
50
50
50
50
50
26
17
13
11
10
70
70
70
70
70
80
80
80
80
80
20
70
70
70
70
70
AB
Spring Offset
Two Positions
PT
DSG012B2
PT
AB
DSG012B3
PT
AB
DSG012B8
b
PT
46
32
75
65
53
35
Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
100
2. For the maximum flow rate in P T of the valves with a
100
55
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
mark, please see page 351.
The valve models with a mark are handled as
Options. If you choose suce valves, check the time
of delivery beforehand.
348
DSG-01 Series Solenoid Operated Directional Valves
DIRECTIONAL CONTROLS
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01-
-A
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
U.S.GPM
[Port "B" Blocked]
Model
Numbers
Graphic
Symbols
Working Pressure PSI
[Port "A" Blocked]
Working Pressure PSI
Working Pressure PSI
1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080
DSG013C2
b
PT
AB
DSG013C3
b
PT
AB
DSG013C4
DSG013C40
Spring Centred
Three Positions
PT
AB
b
PT
AB
DSG013C60
a
PT
26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0) 26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0)
15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4) 15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4)
26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2)
23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9)
23.8 23.8(5.8) 9.2(4.8) 26.4(10.0) 20.1(17.4) 17.7(4.0) 15.1(2.6) 9.2(1.8) 26.4(10.0) 20.1(7.4) 17.7(4.0) 15.1(2.6) 9.2(1.8)
23.8
23.8
23.8(6.9) 11.4(3.7) 7.9(2.9) 13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3) 13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3)
22.5
22.5
22.5 21.1(10.6) 21.1(5.8) 22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2) 22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2)
21.1
21.1 21.1(7.9) 16.6(4.0) 6.6(2.4) 18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6) 18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6)
11.4(6.1) 11.4(6.1) 11.1(6.1) 11.1(6.1) 11.1(6.1) 14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4) 14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4)
10.6(6.1) 10.6(6.1) 10.0(6.1) 9.5(6.1) 9.2(6.1) 12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9)
26.4
26.4
26.4
26.4
26.4
AB
DSG013C9
26.4
26.4
26.4
26.4
26.4
26.4
5.3
4.0
2.6
2.6
2.1
5.3
4.0
2.6
2.6
2.1
PT
AB
DSG013C10
a
PT
AB
DSG013C11
b
PT
AB
DSG013C12
No-Spring
Detented
DSG012D2
21.1
21.1
21.1
21.1
21.1
11.9
11.9
16.4(3.4)
4.0(2.6)
15.9(7.1)
9.2(4.8)
16.4(3.4)
4.0(2.6)
13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)
11.9(5.6) 11.9(4.2) 10.0(3.4)
AB
13.2
PT
9.5(4.8) 7.4(3.4) 5.8(3.2)
AB
Spring Offset
Two Positions
PT
26.4 26.4(16.6) 26.4(8.7) 26.4(7.1) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2)
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9)
26.4(17.2) 22.5(13.7) 19.0(13.7) 17.2(9.0)
26.4
26.4
26.4
26.4
26.4
6.1
5.3
3.4
2.6
1.3
18.5(13.2) 15.1(10.6) 13.2(6.6) 11.4(5.0)
26.4 26.4(16.6) 26.4(8.7) 26.4(7.1) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4) 26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2)
26.4
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6) 26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9)
DSG012B2
22.5
22.5
22.5
22.5
22.5
5.3
4.2
4.2
4.0
18.5
18.5
18.5
18.5
18.5
13.2
13.2
13.2
13.2
6.9
4.5
3.4
2.9
PT
AB
DSG012B3
PT
AB
DSG012B8
PT
13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)
E
DSG-01 Series Solenoid
Operated Directional Valves
A B
22.5(16.6) 21.1(13.2) 16.6(10.6) 11.6(8.5) 11.6(8.5)
22.5(7.9) 15.9(8.7) 13.2(7.4) 10.6(7.4) 10.6(7.4)
21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5)
13.2
18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7)
21.1(13.2) 18.5(10.6) 15.9(5.3) 11.9(2.6) 7.9(2.6)
2.6
9.2(5.3) 6.1(4.0) 4.0(2.1) 2.6(1.3) 1.9(1.3)
3.4
Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
( Example )
50 Hz, At minimum serviceable voltage
(80% of rated voltage)
50 Hz, At rated voltage
The maximum flow rate is constant
regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
60 Hz, At rated voltage
2. For the maximum flow rate in P T of the valves with a
26.4
26.4(11.4)
15.1(10.0)
60 Hz, At minimum serviceable voltage
(90% of rated voltage)
mark, please see page 351.
The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.
DSG-01 Series Solenoid Operated Directional Valves
349
List of Standard Models and The Maximum Flow
Models with DC or R Type Solenoids: DSG-01-
-D /R
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
U.S.GPM
[Port "B" Blocked]
Model
Numbers
Graphic
Symbols
Working Pressure PSI
[Port "A" Blocked]
Working Pressure PSI
Working Pressure PSI
1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080
A B
DSG013C2
26.4
26.4
26.4
26.4
26.4
PT
AB
DSG013C3
b
PT
AB
DSG013C4
Spring Centred
Three Positions
PT
AB
DSG013C40
b
PT
AB
DSG013C60
a
PT
26.4 26.4 26.4 26.4 26.4
21.1 21.1 21.1 21.1 21.1
23.8 13.2 10.0
23.8 23.8
5.3
11.1 6.9
17.2 10.6 8.7
22.5 22.5
11.9 7.9
6.9
13.3 13.3 13.3 13.3 13.3
10.8 10.8 10.8 10.8 10.8
26.4
14.5
20.6
18.5
26.4
16.4
22.5
17.2
17.4
15.3
11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3
7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3
6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3
5.8 26.4
14.5
4.5
19.8 20.6
18.5 18.5
7.7 26.4
6.1 16.4
6.3 22.5
5.0 17.2
17.4 17.4
15.3 15.3
11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3
7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3
6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3
5.8
4.5
19.8
18.5
7.7
6.1
6.3
5.0
17.4
15.3
AB
DSG013C9
26.4
26.4 26.4
26.4
26.4
5.3
4.0
2.6
2.6
2.1
5.3
4.0
2.6
2.6
2.1
22.5
22.5
22.5
9.2
21.1
6.1
10.6
5.3
26.4
19.6
14.8
11.4
9.5
7.4
7.4
5.3
6.3
5.0
26.4
26.4 26.4
26.4
26.4
6.1
5.3
3.4
2.6
1.3
22.5
22.5
22.5
9.2
21.1
6.1
10.6 26.4
5.3 19.6
14.8
11.4
9.5
7.4
7.4
5.3
6.3
5.0
26.4
19.6
26.4
22.5
26.4
19.6
14.8
11.4
15.9
12.2
14.8
11.4
9.5
7.4
10.6
8.5
9.5
7.4
7.4
5.3
9.5
7.4
7.4
5.3
6.3
5.0
8.5
6.3
6.3
5.0
19.8
19.8
19.8
19.8
19.8
10.6
7.9
7.1
13.2
13.2
11.9
11.9
13.2
11.1
10.6
10.6
8.2
6.1
19.8
17.2
9.2
7.9
6.3
5.0
19.8
17.2
6.1
4.5
5.8
4.8
19.8
17.2
5.0
3.4
5.8
4.8
19.8
17.2
4.5
3.2
PT
AB
DSG013C10
a
PT
AB
DSG013C11
a
PT
AB
DSG013C12
No-Spring
Detented
DSG012D2
AB
11.9
13.2
11.9
PT
7.9
6.6
5.8
4.2
4.2
4.0
3.4
13.2
13.2
13.2
13.2
13.2
6.9
4.5
3.4
2.9
2.6
18.5
18.5
18.5
18.5
18.5
21.1
21.1
21.1
21.1
21.1
5.3
18.5
18.5
18.5
18.5
18.5
AB
Spring Offset
Two Positions
PT
DSG012B2
PT
AB
DSG012B3
PT
AB
DSG012B8
b
PT
12.2
8.5
19.8
17.2
14.0
9.3
Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
26.4
2. For the maximum flow rate in P T of the valves with a
26.4
14.5
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
mark, please see page 351.
The valve models with a mark are handled as
Options. If you choose suce valves, check the time
of delivery beforehand.
350
DSG-01 Series Solenoid Operated Directional Valves
DIRECTIONAL CONTROLS
Maximum Flow of Centre By-Pass
In valve type 3C60, in case where the actuator is put on in between the cylinder ports A and B as illustrated below and
where the actuator moves and suspended at its stroke end and where the valve is then shifted to the neutral position in
the suspended state of the actuator, the maximum flow rates available are those as shown as the table below regardless
of any voltage in the range of serviceable valtage.
Max. Flow
Graphic
Symbol
Mode Numbers
10 MPa
16 MPa
25 MPa
31.5 MPa
35 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (5080 PSI)
AB
55
(14.5)
DSG-01-3C60-A /D /R
L/min (U.S.GPM)
PT
44
(11.6)
30
(7.9)
26
(6.9)
22
(5.8)
E
List of Shockless Models and The Maximum Flow
-D /R
Max. Flow
L/min (U.S.GPM)
[Port "B" Blocked]
No. of
Valve
Positions
Spool-Spring
Arrangement
Graphic
Symbol
Model Numbers
Working Pressure
MPa (PSI)
10
(1450)
16
(2320)
25
(3630)
63
(16.6)
63
(16.6)
40
(10.6)
60
(15.9)
50
(13.2)
40
(10.6)
45
(11.9)
40
(10.6)
40
(10.6)
20
(5.3)
45
(11.9)
40
(10.6)
A B
S-DSG-01-3C2
Three
Positions
a
PT
Spring
Centred
AB
S-DSG-01-3C4
a
PT
Two
Positions
Spring
Offset
AB
S-DSG-01-3B2
b
PT
50
(13.2)
45
(11.9)
[Port "A" Blocked]
Working Pressure
MPa (PSI)
10
16
25
(1450) (2320) (3630)
Working Pressure
MPa (PSI)
10
16
25
(1450) (2320) (3630)
40
(10.6)
32
(8.5)
40
(10.6)
32
(8.45)
32
(8.5)
20
(5.3)
32
(8.5)
16
(4.23)
25
(6.6)
16
(4.23)
16
(4.2)
12
(3.17)
40
(10.6)
32
(8.5)
40
(10.6)
32
(8.45)
32
(8.5)
20
(5.3)
32
(8.5)
16
(4.23)
25
(6.6)
16
(4.23)
16
(4.2)
12
(3.17)
30
(7.9)
30
(7.9)
30
(7.9)
60
(15.9)
40
(10.6)
40
(10.6)
DSG-01 Series Solenoid
Operated Directional Valves
Models with DC or R Type Solenoids: S-DSG-01-
Notes: 1. The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.
L/min
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
60
(15.9)
50
(13.2)
40
(10.6)
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
U.S.GPM
DSG-01 Series Solenoid Operated Directional Valves
351
Reverse Mounting of Solenoid.
In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position
(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse
position -SOL a side- is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.
A
SOL b
SOL a
Standard Mtg. of Solenoid
Reverse Mtg. of Solenoid
Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B) .
(Example) In case of Spool Type "2"
Neutral Position
SOL. a Energised
Position
SOL. b Energised
Position
A
B
b
a
P
2B2A
2B2B
b
"A": Use of Neutral and
SOL. a Energised
Position (2B2A)
"B": Use of Neutral and
SOL. b Energised
Position (2B2B)
Graphic SymbolsG
Model Numbers
Standard
Mtg. Type
A
A
b
DSG-01-2B2A
Reverse
Mtg. Type
DSG-01-2B A
T
raphic Symbols
Model Numbers
Standard
Mtg. Type
AB
DSG-01-2B B
a
P
b
P
DSG-01-2B2B
DSG-01-2B3B
DSG-01-2B4B
DSG-01-2B60B
DSG-01-2B10B
In the above table, the graphic symbols in mounting
type highlighted with shade are optional extra,
therefore, please confirm the time of delivery with
us before ordering.
352
Reverse
Mtg. Type
DSG-01 Series Solenoid Operated Directional Valves
DIRECTIONAL CONTROLS
Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
Standard Type (Without Shockless Function)
[Result of Measurement]
[Test Conditions ]
Pressure:
Flow Rate:
Viscosity:
Voltage:
16 MPa (2320 PSI)
31.5 L /min (8.3 U.S.GPM)
35 mm 2 /s (164 SSU)
100 %V
(After coil temprature rises and saturated)
ON
Solenoid
OF F
O FF
0
Spool Shift
Max.
T2
Type
Model Numbers
Standard
Type
DSG-01-3C2- A
DSG-01-3C2- D
DSG-01-3C2- R
Time ms
T1
T2
15
48
50
23
19
100
Shockless Type
[Reaults of Measurement]
[Test Circuit and Conditions]
Accelmeter
OF F
ON
SOL a
Speed
G1
a
G2
Acceleration (G)
Load
Pressure (Ps)
Ps
T1
Setting Pressure (Ps): 7 MPa (1020 PSI)
Load (W): 1000 kg (2205 1bs.)
Speed: 8 m/min (26.2 ft./min)
Viscosity: 35 mm 2 /s (164 SSU )
Type
T2
Time
Model Nmbers
Time Acceleratio n
ms
m/s2 (G)
T1 T2
G1
G2
Shockles s
Type
S-DSG-01-3C2- D
70 30
12
(1.2 )
7
(0.7 )
Standard
Type
DSG-01-3C2- D
35 25
18
(1.8 )
15
(1.5 )
DSG-01 Series Solenoid Operated Directional Valves
E
DSG-01 Series Solenoid
Operated Directional Valves
T1
353
Pressure Drop
Pressure drop curves based on viscosity of 35 mm2 /s (164 SSU) and specific gravity of 0.850.
Standard Type: DSG-01
PSI
600
MPa
4
Model Numbers
Pressure Drop P
500
12
80
16
20
DSG-01-3C3
DSG-01-3C60
DSG-01-3C9
DSG-01-3C10
DSG-01-3C11
DSG-01-3C12
DSG-01-2D2
100 L/min
DSG-01-2B2
U.S.GPM
DSG-01-2B3
DSG-01-2B8
60
DSG-01-3C40
100
40
200
20
A T
DSG-01-3C4
P B
B T
DSG-01-3C2
400
300
Pressure Drop Curve Number
P A
24
Flow Rate
Shockless Type: S-DSG-01
PSI
180
MPa
1.2
160
120
80
0.8
0.6
Pressure Drop Curve Number
P A
B T
P B
A T
S-DSG-01-3C2
S-DSG-01-3C4
S-DSG-01-2B2
1.0
P
Pressure Drop
Model Numbers
0.4
40
0.2
0
10
0
20
4
30
6
40
10
50
12
14
60
L/min
16
U.S.GPM
Flow Rate
For any other viscosity, multiply the factors in the table below.
Viscosity
mm 2/s 15
Factor
SSU
77
40
50
60
70
80
90
100
20
30
98
141 186 232 278 324 371 417 464
0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
For any other specific gravity (G'), the pressure drop ( P') may be
obtained from the formula below.
P' = P (G'/0.850)
354
DSG-01 Series Solenoid Operated Directional Valves
P T
2
DIRECTIONAL CONTROLS
Mounting surface: ISO 4401-AB-03-4-A
TERMINAL BOX TYPE
Models with AC Solenoids
Single Solenoid: Spring Offset
DSG-01-2B -A -70/7090
Double Solenoid: Spring Centred & No-Spring Detented
3C -A -70/7090
DSG-01- 2D2
Solenoid Indicator Light
(For Sol a)
145.7
(5.74)
Pressure Port "P"
Cylinder Port "A"
76.7
(3.02)
142.2
(5.60)
Solenoid Indicator Light
(For Sol b)
196.4
(7.73)
95
(3.74)
26
(1.02)
50.7
(2.00)
For other dimensions, refer to "spring Centred and
No-Spring Detented" models.
Solenoid being mounted in the reverse position
SOL a side is also available.
46
(1.81)
A100
SOL a
SOL b
13.5
(.53)
70
(2.76)
38
(1.50)
Mounting Surface
(O-Rings Furnished)
Space Needed to Remove
Solenoid-Each End
45.5
Electrical Conduit Connection
"C " Thd. (Both Ends)
(1.79)
Lock Nut
Tightening Torque:
10.3-11.3 Nm (91-100 IN.lbs.)
33
(1.30)
23.5 47(1.85)
(.93)
88.8
(3.50)
Tank Port "T"
T
B
A
P
27
(1.06)
Manual Actuator-Both Ends
6(.24) Dia.
3(.12) Dia.
5(.20) Deep
VIEW ARROW X
X
Model Numbers
"C " Thd.
DSG-01-
-A -70
DSG-01-
-A -7090 1/2 NPT
G 1/2
Locating pin can be fitted to this hole to conform with
ISO4401-03-02-94. However, locating pin is not provided
to standard design valve. When ordering valve with a
locating pin, please consult Yuken.
DSG-01 Series Solenoid
Operated Directional Valves
Cylinder Port "B"
SOL b
31.75
(1.25)
40.5
(1.59)
31 0.75
(1.22) (.03)
32.5
(1.28)
5.5(.22) Dia. Through
9.5(.37) C' Bore
4 Places
DIMENSIONS IN
MILLIMETRES (INCHES)
Models with DC Solenoids: (S-)DSG-01-D -70/7090
Models with R Type Solenoids: (S-)DSG-01-R -70/7090
Spring Centred
No-Spring Detented
Spring Offset
Space Needed to Remove
Solenoid-Each End
50
(1.97)
204.4(8.05)
149.7
(5.89)
80.7
(3.16)
D24
SOLa
SOL b
D
3
Double Solenoid
Models Only
Spring Offset Type 146.2
(5.76)
For other dimensions, refer to models with AC solenoids.
DSG-01 Series Solenoid Operated Directional Valves
355
Sub-plate : DSGM-01/01X/01Y-31/3180/3190
14.2
(.56)
"C" Thd.
4 Places
DSGM-01-31
Piping Size
"C" Thd.
Rc 1/8
DSGM-01-3180
1/8 BSP.F
DSGM-01-3190
1/8 NPT
DSGM-01X-31
Rc 1/4
"D" Thd.
"E"
mm(IN.)
M5
10 (.39)
No.10-24 UNC
12 (.47)
M5
10 (.39)
DSGM-01X-3180
1/4 BSP.F
DSGM-01X-3190
1/4 NPT
No.10-24 UNC
12 (.47)
Rc 3/8
M5
10 (.39)
3/8 NPT
No. 10-24 UNC
12 (.47)
DSGM-01Y-31
DSGM-01Y-3190
T
11
(.43)
7 (.28) Dia. Through
7
(.28) 11 (.43) Dia. Spotface
2 Places
DSG-01 Series Solenoid Operated Directional Valves
37
(1.46)
24
(.94)
25.8
(1.02)
31
(1.22)
31.75
(1.25)
48
(1.89)
63
(2.48)
Sub-plate
Model Numbers
356
16
(.63)
15
(.59)
8.5
(.33)
7.5
(.30)
12.7(.50)
5.2
(.20)
71
(2.80)
85
(3.35)
32
(1.26)
"D" Thd. "E" Deep
4 Places
0.75
(.03)
15.5
(.61)
7 (.28) Dia.
4 Places
40.5
(1.59)
30.2
(1.19)
21.5
(.85)
DIMENSIONS IN
MILLIMETRES (INCHES)
12.5
(.49)
35.5
(1.40)
58.5
(2.30)
DIRECTIONAL CONTROLS
PLUG-IN CONNECTOR TYPE (N)
PLUG-IN CONNECTOR WITH INDICATOR LIGHT (N1)
DIMENSIONS IN
MILLIMETRES (INCHES)
-A - N -70/7090
N1
Models with DC Solenoids: (S-)DSG-01-D - N -70/7090
N1
Models with R Solenoids: (S-)DSG-01-R -N-70/7090
Models with AC Solenoids: DSG-01-
SOL b
A100
Double Solenoid
Models Only
23.5
(.93)
SOLa
Lock Nut
Tightening Torque:
10.3 - 11.3 Nm (90 - 100 IN.lbs.)
Model Numbers
DSG-01-
-A -N
(S-)DSG-01-
-D -N
(S-)DSG-01-
-R -N
C
196.4
(7.73)
204.4
(8.05)
204.4
(8.05)
D
76.7
(3.02)
80.7
(3.18)
80.7
(3.18)
E
88.5
(3.48)
99.5
(3.92)
102.5
(4.04)
F
53
(2.09)
64
(2.52)
57.2
(2.25)
G
H
27.5 39
(1.08) (1.54)
27.5 39
(1.08) (1.54)
34
53
(1.34) (2.09)
DSG-01 Series Solenoid
Operated Directional Valves
D
29.5
(1.16)
72.5
(2.85)
The position of the Plug-in connector can be changed as
illustrated below by loosening the lock nut. After
Cable Departure
completion of the change, be sure to tighten the lock nut
with the torque as specified below.
Cable Applicable:
....
Outside Dia.
8 - 10 mm (.31 - .39 in.)
Conductor Area ....
46(1.81)
Not Exceeding 1.5 mm2 (.0023 Sq. in.)
G
For other dimensions, refer to "Terminal Box type" (Page 356).
Models with Push Button & Lock Nut
(S-)DSG-01-
- -C
AC: 132.2(5.20)
DC/R: 136.2(5.36)
Lock Nut
Press the "Push Button" then turn "Lock Nut"
clockwise. The position of the "Push Button" is held.
Be sure to loosen "Lock Nut" fully before solenoid
is energised.
SOL b
Push Button
Interchangeability in Installation Current and New Design
In ouder to achieve higher pressure, higher flow, lower pressure drop DSG-01 valves has been upgraded from the 60
design series to the 70 design series.
The figures in the table below are the comparison between the current and the new design valves.
Specifications
Design Number
Max. Flow
L/min
(U.S.GPM)
Max. Operating
Pressure
MPa (PSI)
Max. T-Line
Back Pres.
MPa (PSI)
New Design: 70
100(26.4)
35(5080)
21(3050)
Current Design: 60
63(16.6)
31.5(4570)
16(2320)
Flow Rate: 60 L/min (15.9 U.S.GPM), Viscosity: 30
mm2/s
Pressure Drop
MPa (PSI)
{PA}
Max. Changeover
Frequency
Cycle/min (min1)
300
(R Type sol. Only 120)
Mass kg (lbs.)
3C /2D
2B
0.9(130)
1.85(4.08)
1.4(3.09)
1.0(145)
2.2(4.85)
1.6(3.53)
(141 SSU), Spool type "2" (Closed centre)
Interchangeability in Installation
Interchangeability in installation in maintained though there are minor differences in demension as in the following table.
A
E
Coil Type
AC
38
(1.50)
K
J
B
A100
SOL b
SOL a
27
(1.06)
DC
R
Design
Number
New Design
: 70
196.4 142.2 46
88.8
95
50.7
26
70
13.5 70.5
(7.73) (5.60) (1.81) (3.50) (3.74) (2.00) (1.02) (2.76) (.53) (2.78)
Current Design 191.4 142.7 48
90.3
90
50.7 23.5
65
11
72
: 60
(7.54) (5.62) (1.89) (3.56) (3.54) (2.00) (.93) (2.56) (.43) (2.83)
New Design
: 70
204.4 146.2 46
88.8
95
54.7
26
70
13.5 70.5
(8.05) (5.76) (1.81) (3.50) (3.74) (2.15) (1.02) (2.76) (.53) (2.78)
Current Design 210 152
48
90.3
90
60
23.5
65
11
72
: 60
(8.27) (5.98) (1.89) (3.56) (3.54) (2.36) (.93) (2.56) (.43) (2.83)
DSG-01 Series Solenoid Operated Directional Valves
357
Details of Receptacle
Type of
Electrical Conduit
Connection
Double Solenoid Type
Single Solenoid Type
Power Supply
(For SOL.a)
Power Suppl y
Power Supply
(For SOL.b)
SOL. a
SOL. b
Ground
Indicator Light
Terminal
Box Type
Common Plate
SOL. b
Indicator Light
Indicator Light
Common
Ground
Ground
Ground
1
1
Plug-in
Connector
Type
1-Power Suppl y
2-Power Suppl y
1. There are two grounding terminals. You can use either one.
2. If you do not need the common plate, remove it.
3. With DC solenoids, polarity is no question.
DANGER
Do not perform wiring while the power is on.
Doing so may result in electric shock, burns or death.
Make the wiring properly. Improper wiring will cause an
irregular movement of the machine, resulting in a grave
accident.
Electrical Circuit
Type of
Electrical Conduit
Connection
Electric Source
AC
ACDC Rectified
DC
Indicator Light
Indicator Light
Power
Supply
Power
Supply
Terminal
Box Type
Power
Supply
SOL.
Common
Ground
SOL.
Common
Ground
Voltage-Surge
Suppressor
SOL.
Common
Ground
Indicator Light
(Integrated in "N1"
model only)
Plug-in
Connector
Type
1-Power
Supply
1-Power
Supply
2-Power
Supply
2-Power
Supply
2-Power
Supply
Ground
Ground
SOL.
Indicator Light
(Integrated in "N1"
model only)
358
Rectifier
Circuit
Voltage-Surge
Suppressor
SOL.
1-Power
Supply
Indicator Light
Voltage-Surge
Suppressor
SOL.
Ground
Voltage-Surge
Suppressor
(Circuit composed
in coil)
DSG-01 Series Solenoid Operated Directional Valves
Rectifier
Circuit
DIRECTIONAL CONTROLS
List of Seals
-DSG-01-
- -70/7090
Spring Offset type
28
16
18
12
17
19
14
29
13
10
15
30
9
7
SOL b
SOL a
6
8
27
24
25
21
23
20
26
22
11
-DSG-01-
- -N/N1-70/7090
16 15 14
18
11
SOL a
19
SOL b
List of Seals
Item
Name of Parts
Part Numbers
O-Ring
SO-NB-A-012 (NBR, Hs90)
O-Ring
SO-NB-P18
18
Packing
19
O-Ring
24
25
Qty.
3C
2D
2B
1790S-VK421290-8
S6
O-Ring
AS 568-026 (NBR, Hs70)
O-Ring
SO-NB-P18
26
O-Ring
SO-NA-P20
27
O-Ring
SO-NA-P4
30
Plug
Remarks
DSG-01 Series Solenoid
Operated Directional Valves
1790S-VK418329-9
Included in Solenoid Ass'y (Item 11)
When ordering the O-Rings, please specify the seal kit number from the table below.
Valve Model Numbers
Seal Kit No.
O-Ring Details for Seal Kit
-DSG-01-
- -70/7090
KS-DSG-01-70
8 (4 Pcs.), 9 & 25 (2 Pcs., see above), 27 (4 Pcs.)
-DSG-01-
- -N-70/7090
KS-DSG-01-N-70
8 (4 Pcs.), 9 & 25 (2 Pcs., see above)
Solenoid Ass'y, Coil, Receptacle and Connector Refer to page 360 for the details of these parts.
DSG-01 Series Solenoid Operated Directional Valves
359
Solenoid Ass'y, Coil, Receptacle and Connector Ass'y No.
Valve Model Numbers
DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01S-DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01DSG-01S-DSG-01S-DSG-01S-DSG-01-
-A100-70
-A120-70
-A200-70
-A240-70
-D12-70
-D24-70
-D48-70
-R100-70
-R200-70
-D12-70
-D24-70
-D48-70
-R100-70
-R200-70
-A100-N-70
-A120-N-70
-A200-N-70
-A240-N-70
-D12-N-70
-D24-N-70
-D48-N-70
-R100-N-70
-R200-N-70
-D12-N-70
-D24-N-70
-D48-N-70
-R100-N-70
-R200-N-70
-A100-N1-70
-A120-N1-70
-A200-N1-70
-A240-N1-70
-D12-N1-70
-D24-N1-70
-D48-N1-70
-D12-N1-70
-D24-N1-70
-D48-N1-70
11
20
Solenoid Ass'y No.
Coil No.
SA1-100-70
SA1-120-70
SA1-200-70
SA1-240-70
SD1-12-70
SD1-24-70
SD1-48-70
SR1-100-70
SR1-200-70
SD1-12-S-70
SD1-24-S-70
SD1-48-S-70
SR1-100-S-70
SR1-200-S-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SR1-100-N-70
SR1-200-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70
SR1-100-S-N-70
SR1-200-S-N-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70
C-SA1-100-70
C-SA1-120-70
C-SA1-200-70
C-SA1-240-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
13
Receptacle
Part No.
18
Connector Ass'y
Part No.
Remarks
R1-70
KR1-A-70
Terminal
Box
Type
KR1-B-70
RR1-70
KR1-A-70
KR1-B-70
RR1-70
GDM-211-A-11
GDM-211-B-11
Plug-in
Connector
Type
GDME-211-R-A-10 GDME-211-R-B-10
GDM-211-A-11
GDM-211-B-11
GDME-211-R-A-10 GDME-211-R-B-10
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
Note: The connector assembly is not included in the solenoid assembly.
360
19
Connector Ass'y
Part No.
DSG-01 Series Solenoid Operated Directional Valves
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
Plug-in
Connector
with
Indicator
Light