Generator Model:
BCJD 40-60
60 Hz
3-Phase
Power Factor
Cos = 0.8
STANDBY POWER (LTP)
kVA 50 50 50 50 50 kWe 40 40 40 40 40 Amps 60 66 69 120 131
Key Features:
Efficient water cooled John Deere diesel engine. Single bearing CGT Stamford alternator Radiator with pressure cap and drain point Fully guarded engine-driven fan Fully welded steel skid base with fork lift pockets Integral fuel tank with filler cap and gauge Heavy duty rubber anti-vibration mountings 12V starter battery and connecting cables Separate engine-driven battery charging alternator Spin on oil and fuel filters and dry type air filter element Industrial silencer (15dBA reduction) supplied loose Key Start control system with analogue instruments Main line circuit breaker Factory Test Certificate Operation & Maintenance Manual Wide range of optional extra features available
Length (L) = 2080mm [82in] Width (W) = 680mm [27in] Height (H) = 1420mm [56in] Dry Weight (inc oil) = 725kg [1600lb] Operating Weight = 870kg [1920lb]
Typical Open Generator Sound Pressure Level at 1m, Free Field (dB)
Overall dBA 96 63 Hz 82 125 Hz 83 250 Hz 88 500 Hz 91 1000 Hz 92 2000 Hz 89 4000 Hz 84 8000 Hz 78
BCJD 40-60
February 2012
STANDBY
mm litres kPa litres/h litres/h litres/h litres/h litres m/s kPa m/s C kPa mm m/s Pa C C litres litres litres kPa litres/h kW kW kW
[in.] [cu.in.] [psi] [gal/h] [gal/h] [gal/h] [gal/h] [gal] [cfm] [inWG] [cfm] [F] [inWG] [in.] [cfm] [inWG] [F] [F] [gal] [gal] [gal] [psi] [pt/h] [btu/min] [btu/min] [btu/min] V A
3 cyl / inline / 4-stroke Turbocharged / None Mechanical Governor 106 / 110 [ 4.19 / 4.33 ] 2.9 [ 179 ] 984 [ 143] 11.1 [ 2.9] 8.7 [ 2.3 ] 6.0 [ 1.6 ] 111 [ 29] 155 [ 41] 0.058 [ 124] 6.25 [ 25] 0.142 [ 300] 480 [ 896] 7.5 [ 30] 65 [ 2.5 ] 1.1 280 50 105 5.7 16.5 9.0 345 0.03 25 [ 1423]
n/a [ 2331] [ 1.1 ] [ 122] [ 221] [ 1.5 ] [ 4.4] [ 2.4 ] [ 50] [ 0.06]
General
Fuel
Air
Thermal
Oil
Cooling
Exhaust
5.4 [ 306]
Elec
ALTERNATOR
SI Units Manufacturer Model (may vary with voltage) Operating Temperature Coupling / No. of Bearings Phase / Poles / Winding Type Power Factor Excitation Insulation System AVR Type Voltage Regulation [US Units]
[F]
Cummins Generator Technologies - STAMFORD PI 144 J PI 144 J 40 [104] 27 [81] Direct / Single Bearing 3-Phase / 4-Pole / Winding 311 Cos = 0.8 Self Excited Class H SX 460 1.0%
All designs and specifications subject to change without notice
General Data
BCJD 40-60
February 2012
Together with digital displays for : Volts, Amps and Frequency Engine operating hours This system also has an increased digital input/output count for external options and, being cost effective in comparison with the optional (BC 701) analogue system, is the preferred choice for most customers.
The BC 7320 provides full AMF functionality with integrated mains monitoring and generator/mains contactor control. BC 7510 & BC 7520 control systems provide the same features as BC 7310 & BC 7320 respectively, plus : BC 7510 - Set-to-Set Synchronisation BC 7520 - Single Set-to-Mains Synchronisation with integrated mains monitoring For Multi Set-to-Mains synchronisation, each set requires BC 7510 with the addition of one mains monitoring panel BC 7560 (not illustrated). See the Synchronisation Guidelines for further details.
The optional control system for this model is BC 701 (photo), based on the Deep Sea Electronics DSE701 Key Start controller. This provides for the manual control of the generator via a two-position key switch and membrane push button for Start, together with Overspeed, Low Oil Pressure and High Coolant Temperature protection. LED indications for protection operation & charge alternator fail Analogue voltmeter with 7-position selector switch Analogue ammeter with 4-position selector switch Analogue frequency meter Analogue gauges for Oil Pressure, Coolant Temp & Charge Amps Engine hours counter Emergency Stop button One auxiliary input for optional features Optional - analogue kW meter, Generator Running volt-free output
The panel is constructed in 1.5mm steel, powder coated to RAL9001 for a high quality, durable finish with side-hinged door.
BCJD 40-60
February 2012
Canopy 1
The optional acoustic enclosure for this model is Canopy 1, suitable for operation in harsh outdoor environmments whilst providing excellent security and acoustic performance. All steel canopy components are pre-treated and polyester powder coated (to a typical thickness of 70-80m) in RAL9001 white and the baseframe is finished in RAL9005 black. Acoustically, the canopy is designed to meet the requirements of EU Legislation 2000/14/EC, achieved by extensive use of fire-retardant polyurethane foam together with efficient management of cooling air. Exhaust noise is minimised by internally mounted high performance exhaust silencers. A steel fuel tank with filler, gauge and accessory points, is integrated within the baseframe. Alernatively, a bund with separate fuel tank can be provided where this is required. Other key features include : Gull-wing doors with gas struts for good service access Panel/breaker access door with viewing window Heavy duty locks on all doors for total security Weather cap on exhaust discharge Emergency Stop button relocated to canopy exterior Lifting and holding down points Fork Lift pockets Optional single roof lifting point.
Dimensions mm [in] L x W x H
Typical Sound Pressure Level at Standby Power dB(A) at 1m [3ft] dB(A) at 7m [23ft]
2261 [89.0]
851 [33.5]
1621 [63.8]
235 [518]
82
72
115 [30.4]
100 [26]
Optional
[ Indicative weight of canopy additional to open set Typical SPL is a mean level, measured in free field conditions, with no contributory background noise.
Alternator : Anti-condensation heater Quadrature droop kit Alternative AVR Thermistor probes and controls
Please refer to Broadcrown Sales Department for full details of these and other options