Emergency Stop Relays, Safety Gate Monitors PNOZ - X9P - GB
Emergency Stop Relays, Safety Gate Monitors PNOZ - X9P - GB
Emergency Stop Relays, Safety Gate Monitors PNOZ - X9P - GB
24 V DC, 100 ... 240 V AC 85 ... 110 % approx. 5.5 W/max. 10 VA 24 V DC, 50 mA
Emergency stop relay and safety gate monitor in accordance with VDE 0113 part 1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98.
7 safety contacts (N/O), 2 auxiliary contacts (N/C) Blow-out fuse: 10 A quick or 6 A slow Safety cut-out: 24 V AC/DC: 10 A Characteristic B/C
Features l Dual-channel operation with or without detecting shorts across the inputs contacts l Automatic or monitored manual reset can be selected l Designed for operation using semiconductor outputs l 2 semiconductor outputs (Fault, K1/K2) l Plug-in connection terminals (Either screw terminals or cage clamp terminals)
Times Switch-on delay Max. 250 ms Delay on de-energisation Max. 25 ms Recovery time Approx. 0.3 s Simultaneity channels 1/2 Max. 150 ms Max. supply interruption before Approx. 35 ms de-energisation Mechanical Data: with cage clamp terminals Terminal blocks per connection 2 Maximum cross section of ext. conductors Flexible, without crimp connectors: 0.2 ... 1.5 mm2 Stripping length 8 mm Dimensions (H x W x D) 101 x 90 x 121 mm Weight 550 g Mechanical Data: with screw terminals Maximum cross section of ext. conductor Single-core Flexible, without crimp connectors: 0.2 ... 2.5 mm2
Flexible, with crimp connectors: 0.25 ... 2.5 mm2
Approvals PNOZ X9P DC PNOZ X9P AC/DC Description l 90 mm P-99 housing, DIN-Rail mounting l Positive-guided relay outputs: 7 safety contacts (N/O) 2 auxiliary contacts (N/C) l Connections for E-STOP buttons safety gate limit switches reset buttons l LEDs for channel 1, channel 2 and power supply
Torque setting for screw terminals Dimensions (H x W x D) Weight
Flexible, with crimp connectors but without plastic sheath: 0.25 ... 1 mm2 Flexible, with TWIN-crimp connectors and plastic sheath: 0.5 ... 1.5 mm2 0.5 ... 0.6 Nm 94 x 90 x 121 mm 550 g
l Increase in the number of contacts available by connecting expander modules Operating modes l l l l l Single-channel operation Dual-channel operation Automatic reset Manual reset Monitored manual reset
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, T elefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-169-10/03
S1 S3
K1
Y31 Y35
24 V DC ext.
K2 K3 &
K1 A2 (0 V)
K2
K3 14 24 34 44 54 64 74 82 92
S1
S3
S34 S37
Y2
A1 A2 Y31 Y35
AC DC 24 VDC ext.
K1
K2 K3 &
K1 B2 (0V)
K2
K3 14 24 34 44 54 64 74 82 92
External wiring
S12 S52 S34 Y2
S1 S3
S1 S3
S34
Y2
S12 S34 S22 Y2
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany T Telephone +49 (7 11) 34 09-0, T elefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-169-10/03
l Increase in safety contacts The number of output contacts can be increased by using contactors with positive-guided contacts.
1L1
K4 Y1
K5 Y2 13
14
K4 1L2
K5
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, T elefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-169-10/03
50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92, EN 61000-6-2, 03/00 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110 part 1, 04/97 -10 ... +55 C -40 ... +85 C 0.6 Nm (screws) Any Thermoplast Noryl SE 100 Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at the time of development.
Order References Type PNOZ PNOZ PNOZ PNOZ UB 24 V DC 24 V DC 24 V DC, 100 ... 240 V AC 24 V DC, 100 ... 240 V AC Order No. 787 609 777 609 787 606 777 606
cage clamp terminals screw terminals cage clamp terminals screw terminals
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Strae 2, 73760 Ostfildern, Germany T Telephone +49 (7 11) 34 09-0, T elefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-169-10/03