Acuvim 392 Brochure
Acuvim 392 Brochure
Acuvim 392 Brochure
ISO9001 Certi ed
BASIC FUNCTION
Basic measuring parameter Voltage (U): Current (I): Power (P): Reactive Power (Q): Apparent power (S): power factor (PF): Frequency (F): True RMS value of three phase voltage,line voltage and the average. True RMS value of three phase current, average and neutral current. Three phase and system total Power. Three phase reactive power and system total reactive Power. Three phase apparent power and system total apparent power. Three phase power factor and system power factor. System frequency.
The nature of the load: Capacitive, inductive and Resistive IO Function Digital Input (DI ): read via communication or display. Auxiliary Power supply(PO): 1 24VDC, use for DI. Energy measuring energy, reactive energy and apparent energy. Demand measuring the demand value of current, power, reactive power and apparent power. The statistics method is sliding window. Communicaton RS485 Port, Modbus-RTU protocol.
Demand
Standard Function
APPLICATION FIELDS
energy management system Industry Automation Area Power Monitoring Substation Automation Power Distribution Automation Intelligent Building Intelligent Electric Switch Gear
TYPICAL WIRING
LINE A B C N 1A FUSE
1A FUSE LINE A B C N
Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27
Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
LOAD
9 10 11 12
1 2 3 7 4 5
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
10
11
12
VN
V3
V2
V1
VN
V3
V2
V1
Acuvim 392
6 22 623 24 7 25 26 27
Acuvim 392
LOAD
FEATURES
Measuring power Parameters of doubleloop, monitoring power Switch; Small size 9696 DIN; Saving space and communication resources; Input directly from voltage or current transformer, PT/CT ratio can be set. large and high clarity LCD screen Communication with Con guration software (IntouchF ixC itec etc.) used With GE, ABB, Schneider, etc; easy installation. High Cost-e ective
3LN-3CT
LINE
A B C 1A FUSE
1A FUSE
Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27
Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
9 10 11 12
1 2 3 7 4 5
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
10
11
12
VN
V3
V2
V1
VN
V3
V2
V1
Acuvim 392
6 22 623 24 7 25
Acuvim 392
26 27
LOAD
LOAD
2LL-3CT
LINE
3LL-3CT
A B C
LINE
A N
1A FUSE
1A FUSE
Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27
Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
9 10 11 12
1 2 3 7 4 5
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
10
11
12
VN
V3
V2
V1
VN
V3
V2
V1
Acuvim 392
6 22 623 7 24 25 26 27
Acuvim 392
LOAD
LOAD
DIMENSIONS
Unit: mm
Acuvim
300
92.00
96.00
Panel
92.00 96.00 Panel cutting Front View 53.50 65.00 Side View 14.50
91.00
CUT-OUT
SPECIFICATION
Parameter Current Voltage Power Reactive Power Apparent Power Power Factor Frequency Energy Reactive Energy Drift with temperature Stability Current Input Rated input Overload Dielectric strength CT Burden Pickup Current 5Arms 10A (continuously); 100A per sec(no recurrence) 2500VAC rms, 50Hz~60Hz, 1minute <0.2VA 0.005Arms Voltage Input Rated Input Input Overload Metering Frequency Dielectric strength PT Burden Input Impedance 400LN/690LL VAC rms (3-phase) 800VAC continuous, 2500VAC, 50/60Hz for 1Minute 45~65Hz 2500VAC rms, 50~60Hz,1 minute <0.2VA 2Mohm/phase Digital Input (DI) Input Type Max Input Current Input voltage Input Resistance Isolated voltage Wet Contact 20mA 16~30V 2k 2500V 0.5 Measuring Accuracy(%rdg) 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 0.2% 1.0% 2.0% <100ppm/ /year Operation Temperature Storage Temperature Humidity Maximum altitude Environment -25C~70C -40 C~85 C 5%~95% non condensation 2000m Power supply Range Power Consumption 100~240Vac, 50/60Hz, 100~300Vdc Facilities category II, pollution level 2 3W 230Vac,50Hz
ORDERING INFORMATION
Acuvim 392 Blank: Without Communication C: Communication Blank: Without DI 4DI: 4DI 24VDC Blank: 50Hz 60: 60Hz Blank: 5A 1A: 1A S1: S2: S6: Voltage, Current Voltage, Current, Energy Full-function
24VDC Auxiliary Power Supply Output Voltage Rated Power Isolated Voltage 24VDC (10 2W 1000VDC Standard Measuring Environmental Safety EMC Dimension IEC 61036 Class 1 IEC62053-21 IEC 60068-2 IEC 61010-1 IEC 61000-4/-2-3-4-5-6-8-11 DIN 43700 Suitable Conditions Dimensions Protection Level 9696 IP40 (Front), IP20(Cover) Accuenergy Corporation Los Angeles-Toronto-Beijing North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: [email protected] Revision Date: March, 2009 Document #1060E1101 )