Acuvim 392 Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Acuvim 392

Double-Line Multifunction Power Meter

ISO9001 Certi ed

Acuvim 392 Double-Line Multifunction Power Meter


INTRODUCTION
The Acuvim392 Series Double-Line Multifunction Power Meter is designed for power distribution system of continuous monitoring and control. It can measure double loop three-phase current, power, energy and demand, as well as three-phase voltage. And also it has 4 switch input and 1 DI auxiliary Power supply with 24VDC. All the data can be read out via RS485 communication interface using Modbus-RTU protocol. The Acuvim392 series combine high accuracy measurement with intelligent multifunction and friendly HMI interface. The Acuvim392 double loop power meter is alternative two multifunction power meter. It saves space and communication resource and reduce the cost of monitoring and power management system, at the same time save a lot of investment when Users achieving distribution automation and energy management.

BASIC FUNCTION
Basic measuring parameter Voltage (U): Current (I): Power (P): Reactive Power (Q): Apparent power (S): power factor (PF): Frequency (F): True RMS value of three phase voltage,line voltage and the average. True RMS value of three phase current, average and neutral current. Three phase and system total Power. Three phase reactive power and system total reactive Power. Three phase apparent power and system total apparent power. Three phase power factor and system power factor. System frequency.

The nature of the load: Capacitive, inductive and Resistive IO Function Digital Input (DI ): read via communication or display. Auxiliary Power supply(PO): 1 24VDC, use for DI. Energy measuring energy, reactive energy and apparent energy. Demand measuring the demand value of current, power, reactive power and apparent power. The statistics method is sliding window. Communicaton RS485 Port, Modbus-RTU protocol.

FUNCTIONS OF Acuvim 392 SERIES


Parameter U (3-phase) I (6-phase) P (phase and the total) Q (phase and the total) S (phase and the total) PF Hz I1_demand I2_demand I3_demand P_demand (total) S_demand (total) Ep (total) Eq (total) Es (total) DI and 24Vdc Acuvim 392-S1 Acuvim 392-S2 Acuvim 392-S6

Real time Measuring

Demand

Energy IO Display Communition


Note:

Standard Function

Optional function, needed speci ed in ordering

APPLICATION FIELDS
energy management system Industry Automation Area Power Monitoring Substation Automation Power Distribution Automation Intelligent Building Intelligent Electric Switch Gear

TYPICAL WIRING
LINE A B C N 1A FUSE
1A FUSE LINE A B C N

Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27

Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
LOAD
9 10 11 12
1 2 3 7 4 5

I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62

10

11

12

VN

V3

V2

V1

VN

V3

V2

V1

Acuvim 392

6 22 623 24 7 25 26 27

Acuvim 392

LOAD

FEATURES
Measuring power Parameters of doubleloop, monitoring power Switch; Small size 9696 DIN; Saving space and communication resources; Input directly from voltage or current transformer, PT/CT ratio can be set. large and high clarity LCD screen Communication with Con guration software (IntouchF ixC itec etc.) used With GE, ABB, Schneider, etc; easy installation. High Cost-e ective

3LN-3CT
LINE

3LN-3CT With 2CT


LINE A B C

A B C 1A FUSE

1A FUSE

Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27

Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
9 10 11 12

1 2 3 7 4 5

I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62

10

11

12

VN

V3

V2

V1

VN

V3

V2

V1

Acuvim 392

6 22 623 24 7 25

Acuvim 392

26 27

LOAD

LOAD

2LL-3CT
LINE

3LL-3CT

A B C

LINE

A N

1A FUSE

1A FUSE

Terminal
1 2 3 7 4 5 6 22 623 24 7 25 26 27

Terminal
I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62
9 10 11 12

1 2 3 7 4 5

I11 I12 I21 I22 I31 I32 I41 I42 I51 I52 I61 I62

10

11

12

VN

V3

V2

V1

VN

V3

V2

V1

Acuvim 392

6 22 623 7 24 25 26 27

Acuvim 392

LOAD

LOAD

3LL-3CT with 2CT

Single phase 2 line

DIMENSIONS
Unit: mm
Acuvim

300

92.00

96.00

Panel

92.00 96.00 Panel cutting Front View 53.50 65.00 Side View 14.50

91.00

CUT-OUT

SPECIFICATION
Parameter Current Voltage Power Reactive Power Apparent Power Power Factor Frequency Energy Reactive Energy Drift with temperature Stability Current Input Rated input Overload Dielectric strength CT Burden Pickup Current 5Arms 10A (continuously); 100A per sec(no recurrence) 2500VAC rms, 50Hz~60Hz, 1minute <0.2VA 0.005Arms Voltage Input Rated Input Input Overload Metering Frequency Dielectric strength PT Burden Input Impedance 400LN/690LL VAC rms (3-phase) 800VAC continuous, 2500VAC, 50/60Hz for 1Minute 45~65Hz 2500VAC rms, 50~60Hz,1 minute <0.2VA 2Mohm/phase Digital Input (DI) Input Type Max Input Current Input voltage Input Resistance Isolated voltage Wet Contact 20mA 16~30V 2k 2500V 0.5 Measuring Accuracy(%rdg) 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 0.2% 1.0% 2.0% <100ppm/ /year Operation Temperature Storage Temperature Humidity Maximum altitude Environment -25C~70C -40 C~85 C 5%~95% non condensation 2000m Power supply Range Power Consumption 100~240Vac, 50/60Hz, 100~300Vdc Facilities category II, pollution level 2 3W 230Vac,50Hz

ORDERING INFORMATION
Acuvim 392 Blank: Without Communication C: Communication Blank: Without DI 4DI: 4DI 24VDC Blank: 50Hz 60: 60Hz Blank: 5A 1A: 1A S1: S2: S6: Voltage, Current Voltage, Current, Energy Full-function

24VDC Auxiliary Power Supply Output Voltage Rated Power Isolated Voltage 24VDC (10 2W 1000VDC Standard Measuring Environmental Safety EMC Dimension IEC 61036 Class 1 IEC62053-21 IEC 60068-2 IEC 61010-1 IEC 61000-4/-2-3-4-5-6-8-11 DIN 43700 Suitable Conditions Dimensions Protection Level 9696 IP40 (Front), IP20(Cover) Accuenergy Corporation Los Angeles-Toronto-Beijing North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: [email protected] Revision Date: March, 2009 Document #1060E1101 )