SPECIFICATION
Model:
LG128641-SFLYH6V
LG128641-SFLYH6V
-2-
1. BASIC SPECIFICATIONS
1.1 Display Specifications
LCD Mode Display Color Background Color Driving Method Viewing Direction Backlight : : : : : : STN Positive Transflective Dark Blue Yellow-Green 1/64 Duty,1/9 Bias 6:00 LED
KS0107 or Eqv.
64 COM
DB0 DB7 RS, R/W, E, /RST /CS1 /CS2 LEDA LEDK LED Backlight
LG128641-SFLYH6V
-3-
R/W
Read/Write Selection H: Read Operation L: Write Operation Enable Signal. Read data when E is H, write
8 9 10 11 12 13 14 15 16 17 18 19 20
E DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 /RST VOUT LEDA LEDK
data at the falling edge of E. Data Bit0 Data Bit1 Data Bit2 Data Bit3 Data Bit4 Data Bit5 Data Bit6 Data Bit7 Reset Signal, Active Low Negative Voltage Output (-10V) LED Power Supply (+5V) LED Power Supply (0V)
LG128641-SFLYH6V
-4-
3. ELECTRICAL CHARACTERISTICS
3.1 DC Characteristics Item Supply Voltage (Logic) Supply Voltage (LCD Drive) Input High Voltage Input Low Voltage Output High Voltage Output Low Voltage Supply Current (Logic) Symbol VDD VDD-VO VIH VIL VOH VOL IDD IOH=-0.2mA IOL=1.6mA VDD=5.0V Condition Min. 4.5 -2.0 0 2.4 0 -(VDD=5.0VD10%, Ta=25:) Typ. 5.0 12.0 ----6.0 Max. 5.5 -VDD 0.8 VDD 0.4 8.0 UNIT V V V V V V V
3.2 Interface Timing Chart Characteristic E Cycle E High Level Width E Low Level Width E Rise Time E Fall Time Address Set-Up Time Address Hold Time Data Set-Up Time Data Delay Time Data Hold Time(Write) Data Hold Time(Read) Symbol Min. 1000 450 450 --140 10 200 -10 10
LG128641-SFLYH6V
-5-
tC t WL E
tR t ASU R/W
t WH
tF t AH
t AH
t DSU t DSU
DB0~DB7
tC t WL E
tR
t WH
tF
tD
t DHR
DB0~DB7
LG128641-SFLYH6V
-6-
3.3 LED Backlight Characteristics (Ta=25 Item Forward Voltage Forward Current Peak Wave Length Luminance Symbol Vf If p Lv
) Min. 3.9 Typ. 4.1 300 568 -Max. 4.3 ---UNIT V mA nm cd/m2
Condition
--50
VO VOUT LEDA
+5V LEDK
LCM
LG128641-SFLYH6V
-7-
4.4 Reset The system can be initialized by setting /RST terminal at low level when turning power on, receiving instruction from MPU. When /RST becomes low, following procedure is occurred. 1. Display off 2. Display start line register is set by 0. (Z-address 0) While /RST is low level, no instruction except status read can be accepted. Reset status appears at DB4 of status byte, after DB4 becomes L, any instruction can be accepted.
LG128641-SFLYH6V
-8-
The Conditions of power supply at initial power up are shown below. Item Reset time Rise time Symbol Min. 1.0 -Typ. --Max. -200 Unit s ns
tRS tR
4.5V
V DD
t RS
tR 0.7V DD 0.3V DD
/RST
4.5 Busy Flag Busy flag indicates the system is now internally operating or not. When busy flag is H, the system is in internal operation. When busy flag is L, the system can accept data or instruction. Busy flag is read out on DB7 by the Status Read instruction.
RS R/W
Busy Check
4.6 Display On/Off Flip-Flop The display on/off flip-flop makes on/off the liquid crystal display. When flip-flop is reset (logical low), selective voltage or non selective voltage appears on segment output terminals. When flip-flop is set (logical high), non selective voltage appears on segment output terminals regardless of display RAM data. The display on/off flip-flop can change status by instruction. The display data at all segments disappear while /RST is low. The status of the flip-flop is output on DB5 by Status Read instruction.
LG128641-SFLYH6V
-9-
4.7 X Page Register X page register designates page of the internal display data RAM. Count function is not available. An address is set by instruction. 4.8 Y Address Counter Y address counter designates address of the internal display data RAM. An address is set by instruction and is increased by 1 automatically by read or write operations of display data. 4.9 Display Data RAM Display data RAM stores a display data for liquid crystal display. 1 bit data of this RAM corresponds to light ON (data=1) or light OFF (data=0) of 1 dot on the display panel. 4.10 Display Start Line Register The register specifies a line in display data RAM that corresponds to the top line of LCD panel, when displaying contents in display data RAM on the LCD panel. Bit data (DB<0:5>) of the display start line information is written into this register by display start line set instruction. It is used for scrolling of the liquid crystal display screen.
LG128641-SFLYH6V
- 10 -
0/1 Controls the display on or off. Internal status and display RAM data are not affected.
Set Address (Y address) Set Page (X address) Display Start Line (Z address) Status Read
Y address (0-63)
Page (0-7)
Sets the X address at the X address register. Indicates the display data RAM displayed at the top of the screen.
B U S Y
O N / O F F
R E S E T
Reads status. BUSY 0: Ready 1: In internal operation ON/OFF 0: Display ON 1: Display OFF RESET 0: Normal 1: Reset
Display Data
Writes data (DB0~DB7) into display data RAM. After writing instruction, Y address is increased by 1 automatically.
Display Data
Reads data (DB0~DB7) from display data RAM to the data bus.
LG128641-SFLYH6V
- 11 -
5.1 Display On/Off RS 0 R/W 0 DB7 0 DB6 0 DB5 1 DB4 1 DB3 1 DB2 1 DB1 1 DB0 D
The display data appears when D is 1 and disappears when D is 0. Though the data is not on the screen with D=0, it remains in the display data RAM. Therefore, you can make it appear by changing D=0 into D=1. 5.2 Set Address (Y Address) RS 0 R/W 0 DB7 0 DB6 1 DB5 AC5 DB4 AC4 DB3 AC3 DB2 AC2 DB1 AC1 DB0 AC0
Y address (AC0~AC5) of the display data RAM is set in the Y address counter. An address is set by instruction and increased by 1 automatically by read or write operations of display data. 5.3 Set Page (X Address) RS 0 R/W 0 DB7 1 DB6 0 DB5 1 DB4 1 DB3 1 DB2 AC2 DB1 AC1 DB0 AC0
X address (AC0-AC2) of the display data RAM is set in the X address register. Writing or reading to or from MPU is executed in this specified page until the next page is set. 5.4 Display Start Line (Z Address) RS 0 R/W 0 DB7 1 DB6 1 DB5 AC5 DB4 AC4 DB3 AC3 DB2 AC2 DB1 AC1 DB0 AC0
Z address (AC0~AC5) of the display data RAM is set in the display start line register and displayed at the top of the screen.
LG128641-SFLYH6V
- 12 -
5.5 Status Read RS 1 R/W 0 DB7 BUSY DB6 0 DB5 ON/OFF DB4 RESET DB3 0 DB2 0 DB1 0 DB0 0
BUSY When BUSY is 1, the chip is executing internal operation and no instructions are accepted. When BUSY is 0, the chip is ready to accept any instructions. ON/OFF When ON/OFF is 1, the display is off. When ON/OFF is 0, the display is on. RESET When RESET is 1, the system is being initialized. In this condition, no instructions except status read can be accepted. When RESET is 0, initializing has finished and the system is in the normal operation condition.
5.6 Write Display Data RS 0 R/W 1 DB7 D7 DB6 D6 DB5 D5 DB4 D4 DB3 D3 DB2 D2 DB1 D1 DB0 D0
Write data (D0~D7) into the display data RAM. After writing instruction, Y address is increased by 1 automatically. 5.7 Read Display Data RS 1 R/W 1 DB7 D7 DB6 D6 DB5 D5 DB4 D4 DB3 D3 DB2 D2 DB1 D1 DB0 D0
Read data (D0~D7) from the display data RAM. After reading instruction, Y address is increased by 1 automatically. One time of dummy read must be required after column address setting.
LG128641-SFLYH6V
- 13 -
B8
B9
BA
BB
BC
BD
BE
BF
Segment
--
--
LG128641-SFLYH6V
- 14 -
P2.5~P2.7
3 74LS138
Y0
/RST
a. Application Circuit 1
b. Application Circuit 2
LG128641-SFLYH6V
- 15 -
Z( =0 ) Y( =180 , =-90 )
1
Top
X'
Bottom
Y'( =0 , =+90 )
1,
2.0
1
Viewing Angle
LG128641-SFLYH6V
- 16 -
B1 Brightness
B2
Driving Voltage Brightness of non-selected dot (B1) Brightness of selected dot (B2)
Contrast=
Non-selective state
Selective state
Non-selective state
Brightness
100%
90%
10%
tf Time
tr
LG128641-SFLYH6V
- 17 -
9. DIMENSIONAL OUTLINE
LG128641-SFLYH6V
- 18 -
L G 128 64 1 S F L Y H 6 V XX
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13)
(1) Brand : Laurel products (2) Module type C - Character module G - Graphic module (3) Display format Character module : Number of characters per line, two digits XX Graphic module : Number of columns, tow or three digits XX or XXX (4) Display format Character module : Number of lines, one digits X Graphic module : Number of rows, two or three digits XX or XXX (5) Development number : One digit X ( 1~9, A~Z ) (6) LCD mode T - TN Positive, Gray S - STN Positive, Yellow-green B - STN Negative, Blue K - FSTN Negative, Black (7) Polarizer mode R - Reflective (8) Backlight type N - Without backlight (9) Backlight color Y - Yellow-green A - Amber B - Blue R - Red W - White M - Multi color
o o
F - Transflective
M - Transmissive
L - Array LED
E - EL
C - CCFL
G - Green
(10) Operating temperature range S - Standard temperature ( 0 ~ +50 C ) (11) Viewing direction 3 - 3:00 6 6:00 9 9:00 U 12:00 H - Extended Temperature ( -20 ~ +70 C )
(12) DC-DC Converter N Without DC-DC converter (13) Version code Nil Standard product 01~ZZ Version code V Built in DC-DC converter
LG128641-SFLYH6V
- 19 -
LG128641-SFLYH6V
- 20 -
LCD module should be stored in the same conditions in which they were shipped from Our company. 2) Exercise care to minimize corrosion of the electrodes. Corrosion of the electrodes is accelerated by water droplets or a current flow in a high humidity environment. 11.3 Design Precautions 1) The absolute maximum ratings represent the rated value beyond which LCD module can not exceed. When the LCD modules are used in excess of this rated value, their operating characteristics may be adversely affected. 2) To prevent the occurrence of erroneous operation caused by noise, attention must be paid to satisfy VIL, VIH specification values, including taking the precaution of using signal cables that are short. 3) The liquid crystal display exhibits temperature dependency characteristics. Since recognition of the display becomes difficult when the LCD is used outside its designated operating temperature range, be sure to use the LCD within this range. Also, keep in mind that the LCD driving voltage levels necessary for clear displays will vary according to temperature. 4) Sufficiently notice the mutual noise interference occurred by peripheral devices. 5) To cope with EMI, take measures basically on outputting side. 6) If DC is impressed on the liquid crystal display panel, display definition is rapidly deteriorated by the electrochemical reaction that occurs inside the liquid crystal display panel. To eliminate the opportunity of DC impressing, be sure to maintain the AC characteristics of the input signals sent to the LCD Module. 11.4 Others 1) Liquid crystals solidify under low temperatures (below the storage temperature range) leading to defective orientation or the generation of air bubbles (black or white). Air bubbles may also be generated if the LCD module is subjected to a strong shock at a low temperature. 2) If the LCD modules have been operating for a long time showing the same display patterns, the display patterns may remain on the screen as ghost images and a slight contrast irregularity may also appear. A normal operating status can be regained by suspending use for some time. It should be noted that this phenomenon does not adversely affect performance reliability. 3) To minimize the performance degradation of the LCD modules resulting from destruction caused by static electricity, etc., exercise care to avoid touching the following sections when handling the module: Terminal electrode sections. J Part of pattern wiring on TAB, etc. J