DO NOT SHUT UNIT OFF DURING PRESSURE CHECK AND OIL PURGE PROCESS. WAIT UNTIL RECOVERY & RECYCLE IN PROCESS LIGHT STOPS FLASHING.
8. Remove oil discharge cup and read the amount from the markings on the cup. LITTLE OR NO OIL REMOVED IS NORMAL. 9. Dispose of recovered oil in accordance with any federal, state or local ordinances. Replace discharge cup
REPALCE ANY OIL REMOVED WITH PROPER LUBRICANT FOR A/C SYSTEM. CHECK VEHICLE MANUFACTURERS PUBLISHED SERVICE PROCEDURES FOR CORRECT LUBRICANT.
10. The recovery & recycle process is now complete. Close the valves on the system hoses and disconnect from vehicle. Necessary repairs can now be made to the A/C system. REPLACING THE FILTERCORE (Units with recovery / recycling) Change Filter core every 20 hours as indicated by unit in a vacuum. 1. Close valves on the hoses or couplings of the RED and BLUE unit hoses. 2. Press START RECOVERY & RECYCLE button and allow unit to run until the LOW gauge rises to 5 to 10 psi. 3. Turn unit power to OFF when the LOW gauge reaches 0 to 5 psi. 4. Loosen the center bolt on the filter shell lid three full turns. 5. Turn the lid counterclockwise until it stops and lift up on the lid. The center bolt may have to be pushed down slightly prior to turning the lid. 6. Remove th esoring plate. Remove the old filter core and dispose of it properly. 7. Remove the new filter (P/N K16200-SP 2 pack) from the vacuum sealed container and install it immediately in the filter shell with the cone-shaped end up. 8. Install the spring plate on top of the new core with the spring facing up. 9. Replace the filter shell lid and turn it clockwise until the marks on the side of the lid are alighned with those on the seal. 10. Tighten the center bolt on the filter shell lid to 10 ft-lbs. Of torque.
Page C-2
Effective 7/2000
Effective 7/2000
Page C-3
CHARGING TIPS
1. USE CAUTION WHEN HANDLING THE UNIT HEATER BLANKETS. The virgin tank heater blankets are on when the unit power is on and can become very hot. Shut power off prematurely will prevent the oil purge from occurring and can prevent removal of filter shell lid for filter core change. 2. Do not leave the oil injection bottle attached to the unit when not in use. 3. Do not push the oil injector button while the vacuum pump is running. 4. Close all tank and hose valves when not in use to prevent loss of refrigerant. 5. Make certain to completely open the R134a service couplings (R134a units only). 6. Charging from the recycled refrigerant tank will be faster when the tank is at least half full, especially in cooler weather. 7. Charging from the virgin refrigerant tank will be faster if the tank is allowed to heat for 20 minutes before starting charge. 8. Make sure that the heater blanket is located on the virgin tank as shown:
Back of unit
VIRGIN TANK
Heater Blanket
Straps D-Rings
GENERAL MAINTENANCE
Check O-rings and depressor gaskets on hoses and couplings EVERY 20 HOURS Replace the Micron Filter Elements EVERY 20 HOURS REPLACE THE MICRON FILTERS 1. Locate the micron filter assemblies on the system and tank hoses:
Hose Filter Assembly Hose Large Section Filter Element
2. Using two 5/8 open end wrenches , separate the filter assembly. 3. Remove the filter element from the assembly. 4. Install a new element (P/N 90420-SP 10 pack) with the core pointing toward large section of filter assembly. 5. Using 2 5/8 open-end wrenches, tighten the 2 pieces of the filter assembly together. Effective 7/2000
Page C-4
ERROR CODES
ERROR CODES ARE ONLY DISPLAYED ON UNITS WITH DIGITAL CHARGING DISPLAYS TO CLEAR ERROR CODE DISPLAY, PRESS THE MODE SELECT BUTTON ONCE E:01 Not Used E:02 The Oil Purge Did Not Occur This error will occur if: 1. The recovery tank vapor valve or hose valve is cleared. 2. The recovery tank is empty. 3.The ambient temperature is below 20 F. E:03 The Vacuum Pump Did Not Start This error will occur if: 1. The system hoses have more than 20 psi in them or applied to them. A recovery operation must be performed before evacuating. E:04 The Units Select Button Did Not Change the Dispensing Unit for the Charge. This error will occur if: 1. The EVACUATE Indicator is ON. Evacuation time is always in minutes. 2. Amounts are programmed for either VIRGIN CHARGE or RECYCLED CHARGE. To clear, dial all programmed charge amounts to zero or turn the machine off and then back on. E:05 The Current Charge Can Not Start This error will occur if: 1. The pressure of the tank being charged from (virgin or recycled) is over 220 psi. This error will generally occur if the recycled tank contains excess air or is too hot. Allow the tank to cool if too hot. If excess air is suspected, shut the unit off and then back on. Wait about 40 seconds. The EXCESS AIR indicator will illuminate if the tank contains excess air. If so, follow the procedures for performing on excess air purge. E:06 The Unit Did Not Complete the Oil / Air Purge at the End of the Recovery Cycle. This error will occur if: 1. There is a restriction in the unit plumbing from the filter shell to the oil purge port. 2. Previous oil purge cycles were interrupted by shutting unit off before purge was complete. Effective 7/2000
Page C-5