0% found this document useful (0 votes)
277 views3 pages

MCM800 081215

The MCM800 module provides condition monitoring and protection for rotating machinery by incorporating vibration monitoring, protection functions, and communication capabilities into a single module to reduce hardware needs. It integrates into DCS systems or operates standalone, and can be installed in a centralized or remote location through its Profibus and Ethernet interfaces. The document provides details on the MCM800's inputs, outputs, communication protocols, reporting values, environmental specifications, and contact information for ABB regarding the power generation product.

Uploaded by

blbka
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
277 views3 pages

MCM800 081215

The MCM800 module provides condition monitoring and protection for rotating machinery by incorporating vibration monitoring, protection functions, and communication capabilities into a single module to reduce hardware needs. It integrates into DCS systems or operates standalone, and can be installed in a centralized or remote location through its Profibus and Ethernet interfaces. The document provides details on the MCM800's inputs, outputs, communication protocols, reporting values, environmental specifications, and contact information for ABB regarding the power generation product.

Uploaded by

blbka
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

System 800xA for Power Generation

MCM800 Machine Condition Monitoring Condition Monitoring Porducts

Addressing the needs of your Rotating Machinery


The MCM800 provides a complete set of functions designed to address the monitoring and protection needs of your rotating machinery. The MCM800 incorporates all monitoring, protection and communication into a single module. This single module concept provides a common interface reducing hardware by combining functions and reduces the need for spare parts. The MCM800 integrates into DCS systems or operates standalone. The module may be installed in a centralized or remote location. Communication to the module is accomplished through the on-board Profibus and Ethernet interfaces. Monitoring and configuration is available with both communication ports. The MCM800 reports the measured values for monitoring and protection along with synchronous speed and harmonic (orders) data used for detecting machine defects. In addition, the MCM800 provides waveform data for more extensive analysis, such as FFTs, waterfall plots, orbits, shaft centerline plots, bode plots, etc. Independent Monitoring Device Universal Module Provides Monitoring and Protection Vibration Eccentricity Thrust (Rotor) Position Differential (Relative) Expansion Case (Absolute) Expansion Profibus DP Controller Interface Ethernet TPC/IP 10/100 Base T Interfaces to all common sensor types Proximity (eddy current) probes Moving Element Velocity probes Piezoelectric Velocity probes Accelerometers DC LVDTs Integrates into DCS system or operates standalone Installs in centralized or remote locations DIN Rail Mountable

MCM800 Machine Condition Monitoring Condition Monitoring Porducts


Field I/O Power Input Supply voltage: +24 / -24 VDC +/-10% Operating Current: 300 mA each supply (typical) Maximum Current (short circuit): 535 mA (+24V), 545 mA (-24V) Power consumption: 7.2 Watts each supply (typical) Parallel terminals Analog Inputs for use in daisy-chaining modules System Power: +24VDC, -24VDC current limited to 30mA. Individually fused Constant current 4.7mA available for piezoelectric devices Range: +/- 20 VDC with 10 VAC peak-to-peak maximum amplitude Optional 4 - 20mA input Event Marker Input Relay Outputs Alert Danger Buffered Outputs available Accuracy 0.25% of Full Scale System Power: -24 VDC current limited to 30mA Adjustable pulse detection (3 V p-p minimum) Dry Contact (Form C) 2A @ 24 VDC / VAC (resistive load) Normally deenergized/energized selectable Dry Contact (Form C) 2A @ 24 VDC / VAC (resistive load) Normally deenergized/energized selectable One BNC connector per channel plus Event Marke +/- 24 Volt range, current limited to 40 mA Accuracy 1% Fixed 50KHz 2-pole Low Pass Analog Filter Physical I/O Module Mounting I/O Termination TBU Mounting TU Terminal Blocks Ethernet Profibus / Modbus Communication RS-485 Profibus DP v1 Modbus RTU Ethernet 10/100 BaseT RS-232 Debug Operation Microprocessors Data sampling Orders Debugging and Firmware Upgrades. Configuration, Control, and Reporting Values. Firmware Upgrades. One slot in Modular Termination Unit (TBU850) 7.87 x 8.46 (maximum) 200mm x 215mm (maximum) Standard 35mm DIN Rail 24A/250V Compression: 0.14-1.5 / 0.14-1.5 / 28-16 solid[mm2] / stranded[mm2] / AWG RJ-45 DSub9F (input), DSub9M (output)

Configuration, Control, and Reporting Values Reporting Values

MCF5282 @ 64 MHz PLL MC56321 DSP @ 250 MHz PLL Sample rate 50K samples / sec Vibration evaluation period 250 msec (4 Hz) 0.5X amplitude and phase 1X amplitude and phase 2X amplitude and phase NX amplitude and phase (where N=3 to 10 user selectable) Not1X amplitude Accuracy 0.25% amplitude Phase +/- 3 degrees with phase correction

Filters Anti-aliasing High Pass Low Pass Integration Speed Alarming Fixed 20 KHz 4-pole Butterworth Analog Low Pass Filter 1 to 1000 Hz 4-pole Butterworth Digital Filter 30 to 15KHz 4-pole Butterworth Digital Filter Velocity to displacement (in/s to mils or mm/s to um) Acceleration to velocity (gs to in/s or gs to mm/s) 0 30,000 RPM High / Low Alert per channel (Full range in EU) High / Low Danger per channel (Full range in EU) Alert Delay 0.1 to 300 seconds per channel Danger Delay 0.1 to 300 seconds per channel

MCM800 Machine Condition Monitoring Condition Monitoring Porducts


DIP Switches Profibus Address Option Switch Profibus termination Environmental Installation Ambient Temperature Humidity Atmospheric Pressure Air Quality Installation Category Seven switches for address selection; one for mode selection Used for calibration, startup mode, diagnostics, and power option.
Document ID

Two switches for termination of Profibus line A and line B.

This card was designed for use as process control equipment in an ordinary (non-hazardous) location. 0 to 55 C (32 to 131 F) 5% to 90% RH up to 55C (non-condensing) Sea level to 3 km (1.86 miles) Non-corrosive Category II per ANSI/ISA-S82.01-1994

For more information please contact: ABB Ltd. Business Unit Power Generation P.O. Box 8131 8050 Zrich SWITZERLAND Phone: +41 (0) 43 317-5380 Fax: +41 (0) 43 317-5382 Internet: www.abb.com/powergeneration