MCM800 081215
MCM800 081215
MCF5282 @ 64 MHz PLL MC56321 DSP @ 250 MHz PLL Sample rate 50K samples / sec Vibration evaluation period 250 msec (4 Hz) 0.5X amplitude and phase 1X amplitude and phase 2X amplitude and phase NX amplitude and phase (where N=3 to 10 user selectable) Not1X amplitude Accuracy 0.25% amplitude Phase +/- 3 degrees with phase correction
Filters Anti-aliasing High Pass Low Pass Integration Speed Alarming Fixed 20 KHz 4-pole Butterworth Analog Low Pass Filter 1 to 1000 Hz 4-pole Butterworth Digital Filter 30 to 15KHz 4-pole Butterworth Digital Filter Velocity to displacement (in/s to mils or mm/s to um) Acceleration to velocity (gs to in/s or gs to mm/s) 0 30,000 RPM High / Low Alert per channel (Full range in EU) High / Low Danger per channel (Full range in EU) Alert Delay 0.1 to 300 seconds per channel Danger Delay 0.1 to 300 seconds per channel
This card was designed for use as process control equipment in an ordinary (non-hazardous) location. 0 to 55 C (32 to 131 F) 5% to 90% RH up to 55C (non-condensing) Sea level to 3 km (1.86 miles) Non-corrosive Category II per ANSI/ISA-S82.01-1994
For more information please contact: ABB Ltd. Business Unit Power Generation P.O. Box 8131 8050 Zrich SWITZERLAND Phone: +41 (0) 43 317-5380 Fax: +41 (0) 43 317-5382 Internet: www.abb.com/powergeneration