Bulletin 30
Bulletin 30
M
GM Transformer Company has established
Liquid Filled Substation Transformers: itself as a leading manufacturer of custom dry
500 kVA to 10,000 kVA type transformers. With an exceptionally
2.5 kV to 34.5 kV
large and experienced engineering staff, MGM has the
Indoor and Outdoor
ability to design to the varying criteria of differing
Dry Type Drives Isolation Transformers: industries while maintaining short lead times. Core and
6, 12, 18, 24 and 36-Pulse coil applications for regulators and UPS systems, low
15 kVA to 7,500 kVA loss/high efficiency drives isolation transformers.
600 V to 25 kV Special custom size K-factor rated substation
Indoor and Outdoor transformers for retrofit are but a few of the special
transformers MGM has designed and manufactured.
Liquid Filled Drives Isolation Transformers:
6, 12, 18, 24 and 36-Pulse MGM employs three winding styles for Special Design
200 kVA to 7,500 kVA Dry Type transformers, based on kVA, voltage and BIL
2.5 kV to 25 kV requirements. The ability to select a specific winding
Indoor and Outdoor style assures the highest degree of mechanical strength
600V Class Transformers: under short circuit stress conditions and suitability for
15 kVA to 3,750 kVA, 3-Phase different voltage classes.
10 kVA to 833 kVA, 1-Phase
Most transformer companies offer standard engineered
products only, and ask the users to make it fit their
applications. MGM can engineer the product both
electrically and mechanically to fit virtually any
application.
Dry Type Transformers
PRODUCT RANGE
Three Phase Barrel wound
Voltage Class KVA
The rectangular barrel wound
600 V thru 1.2 kV 9 thru 2,000
style is the most common
2.4 kV thru 5 kV 15 thru 10,000 method in the industry for 600V
8.7 kV thru 15 kV 45 thru 10,000 and 5kV applications.
25 kV 225 thru 10,000 MGM’s standard is the superior
34.5 kV 500 thru 10,000 oval barrel wound method for
600V class and 5kV class, 45kV
Single Phase BIL maximum.
Voltage Class KVA
600 V thru 1.2 kV 10 thru 833
2.4 kV thru 5 kV 15 thru 1,667
8.7 kV thru 15 kV 30 thru 1,667
25 kV 150 thru 1,667
34.5 kV 333 thru 1,667
Section wound
The section wound style is rarely
used in the industry due to
higher cost vs. barrel or random
wound. May be used for special
applications up to 125 kV BIL.
SPECIFICATIONS
Aluminum/Copper
150°C / 115°C / 80°C or Special Request
220°C insulation
NEMA standard/special sound levels
ANSI standard/special BIL levels
VPI
UL K-factor ratings
Disk wound
UL/CUL/CE/CSA listings (check with factory) Due to its superior design criteria,
Multi-voltage input/output MGM uses this method on most
15kV class to 125kV BIL.
50/60/400 Hz
OEM core and coil
Multiple electrostatic shields
Design to meet customer impedance and loss
criteria
Ultra Efficient Designs
Substation Transformers
RANGE
225kVA-
3,750kVA,
600 V
225kVA-
10,000kVA,
2.4/5/15kV
500kVA-
10,000kVA,
34.5kV
Dry Type Substation 1800 kVA
SPECIFICATIONS Primary 6.3kVΔ Secondary 400Y/231V 50Hz;
Aluminum/Copper 150°C Rise; Copper Wound; Digital Temperature
150°C / 115°C / 80°C Monitor; NEMA 3R Louvers; Low Voltage
220°C insulation Transition Section with Flex Leads
Indoor/outdoor
ANSI standard/special BIL levels
VPI
UL K-factor ratings For over two decades, MGM Transformer Company has been a reliable source for
UL/CUL/CSA listings quality secondary unit substation transformers. Our standard designs cover the
(check with factory) full range of requirements from 5kV to 34.5kV, 500kVA to 10,000kVA, in both
liquid and dry type.
General Construction
Depth Width Coils are vacuum-pressure-
impregnated (VPI) with solventless
polyester resin, ensuring complete
impregnation of the windings and
Approximate Enclosure Dimensions and Weights insulation.The finished VPI coils are
Based upon 15kV class, 150°C rise. Al windings incredibly strong, readily dissipate heat
Height Width* Depth Weight and are protected against moisture,
KVA
Inches Inches Inches lbs dirt and most industrial contaminants.
225 90 56 50 2,400 Ventilated dry-type winding designs
300 90 56 50 3,000 vary depending on the voltage, basic
impulse level (BIL) and current of the
500 90 72 50 3,700
individual winding and/or application
750 90 80 50 4,900
of the transformer. For all units, the
1000 90 90 50 6,000
insulation system will be 220°C
1500 90 90 50 8,100 regardless of the average winding rise.
2000 100 100 60 9,700
2500 108 108 60 11,500 MGM ventilated dry-type transformers
3000 108 108 60 12,800 are designed for indoor or outdoor
*Add 18" to width for each ATC. applications in schools, hospitals,
industrial plants, commercial buildings
NOTES: and any place requiring safe and
1. Coordination to HV/LV Switchgear may require Transition/Throats.
2. Depth and height dimension may increase for outdoor NEMA 3R enclosures.
dependable power.Ventilated dry-type
3. Dimensions may vary with special requirements. transformers offer an economical
4. Dimensions and weights are subject to change without notice and should not be used for construction purposes. solution and are extremely reliable
5. Compact designs available.
6. Retrofit designs available. (with or without enclosures)
when properly installed and
7. Special, totally enclosed enclosures available. (dimensions will vary) maintained.
8. MGM is now offering NEMA 1/3R/4 stainless steel enclosures.
D RY
ENCLOSURE
The standard indoor enclosure is NEMA 1, Category C
construction. Enclosures are suitable for lifting, jacking,
rolling or skidding with provisions for lifting from the
transformer base. High voltage and low voltage ANSI
ground pads are provided.
COILS
Generally, low voltage (LV) windings less than 2,400
STANDARD FEATURES volts are either multi-conductor barrel or sheet
conductor types. Multi-conductor windings may be
■ UL Listing, CSA, & CUL
more economical and preferred in smaller kVA low
■ Vacuum Pressure Impregnated voltage applications in which the current and axial short
(VPI) windings circuit forces are relatively small. High voltage (HV)
■ 80°, 115°, 150°C average winding windings 2,400 volts or greater may be single-section
rise ratings barrel, multi-section barrel or disk types. Ventilated dry-
■ 60 Hz operation type coils may be either round, oval or rectangular
■ 220°C insulation system through about 2,000 kVA. Transformers larger than
■ Aluminum or copper windings 2,000 kVA generally are designed with round windings
unless there are special considerations, such as limiting
■ ANSI ground pads
dimensions.
■ Core ground strap
Q u a l i t y Universities / Labs
UCLA
UC Berkeley
Un i v e r s i t y of M ic h ig a n
University of Minnesota
y o u c a n s e e
UC San Diego Lawrence Livermore Labs
Fermilab SUNY
Argonne National Lab
Wind-Turbine Power Generation
Palm Springs, California Tehachapi Pass, California
Solar City
M G M Tra n s fo r m e r C o m p a ny
5701 Smithway Street, City of Commerce, CA 90040
1-800-423-4366 Fax: (323) 726-8224 Email: [email protected] www.mgmtransformer.com