Programing Basic3
Programing Basic3
Contents:
Switching to programming mode
Adjustable parameters, change machine type
Temperature and time setting, reversing
Cooling time, residual moisture level, extra drying time
Quick view parameter list
487 21 98 61 - 290,530,650 - GB
Programming 5
1
Switching to Programming mode
• Open the loading door (the door must be
kept open).
1 • Open the door of the control panel.
Programming mode 2
X1 1
Caution SP
7
487 21 98 61 - 290,530,650 - GB
6 Programming
Adjustable parameters:
00. Machine type
01.-03. Temperature
04. Temperature hysteresis
05. Time interval
06. Max. running time or “coin 2”
07. Running time between reversals
08. Cooling time
09.-11. Residual moisture levels
12.-14. Extra drying time
SP = Parameter Programming
Clock button:
Shift between different parameters
continues overleaf
487 21 98 61 - 290,530,650 - GB
Programming 7
Change of parameters
When the machine type has been select-
ed, push the clock button; parameter no.
01. will come up on the display: After two
seconds a value is shown that can be
changed by means of the count up/down
buttons.
Clock button,
change to next parameter
Note! Parameter06. = maximum running time for a manual machine or running per
coin insert on “coin insert 2” (double coin insert). If maximum running time on a man-
ual machine is changed e.g. to 30 minutes, the machine cannot choose to run more
than the maximum time, i.e. 30 minutes.
Temperature setting
The highest temperature
can be set to a value
between 32°C-85°C.
Temperature
Factory setting = 85
program High
Lowest temperature
Next para-
can be set to a value
meter
between 32°C-85°C.
Temperature- Factory setting = 50
program Low Count down Count up
Time setting
Running time Can be set to a value From 0.1 to 9.9 minutes the setting can
per pulse between 0.1 and 90 minutes. be changed by increments of
(per coin insert - Factory setting = 15 1/10 minute per push.
Time interval or push From 10 to 90 minutes the setting can
if time- be changed by increments of
controlled) 1 minute per push.
Max. running Can be set to a value From 0.1 to 9.9 minutes the setting can
time on manual between 0.1 and 90 minutes. be changed by increments of
machine or Factory setting = 60 1/10 minute per push.
Max. running running time per From 10 to 90 minutes the setting can
time or coin insert on be changed by increments of
Time inter- coin 2 (double 1 minute per push.
val, insert)
coin 2
Reversing
Can be set to a value Change the setting by
between 0.1 and 9,9 minutes. 1/10 minute per push.
Factory setting = 5.0
Running time
between reversals
487 21 98 61 - 290,530,650 - GB
Programming 9
Cooling time
Running time Can be set to a value
without between 00 and 10 minutes.
heat at end of Factory setting = 03
Cooling time cycle
Count down Count up
Residual Can be set to a value The values for residual moisture are
moisture level, between 05 and F0. given in hexadecimals (05-F0). See
F0 = ready Factory setting F0 explanation on following page.
Program
to put away
P1 =
extra dry
Residual Can be set to a value
moisture level, between 05 and F0.
F0 = ready Factory setting F0
Program to put away
P2 =
ready to put away
Residual Can be set to a value
moisture level, between 05 and F0.
e.g. 30 = Factory setting 30
Program iron dry
P3 =
ironing dry
Extra drying Can be set to a value Extra drying time when the value set
time between 00 and 20 minutes. in parameter 11 has been reached.
in minutes Factory setting 00
Program
P3 =
ironing dry
487 21 98 61 - 290,530,650 - GB
10 Programming
0% residual moisture
5V F0
E0
D0
C0
B0
A0
Ironing dry
3A
30
20
Parameters 12 - 14
10 Extra drying time 0-20 minutes
0V 05
30 % 25 20 15 10 05 % 00
0 03 09 minutes
P3, P2, P1
F0 The values for residual moisture are shown in the display in so-
C0
called hexadecimals - a series of numbers covering a total of 16
values for each digit (0,1,2,3,———9,A,B,C,D,E,F). A total of
B0 236 values can be shown.
A0
Example:
Total: P3, ironing dry, parameter no. 11 = 30.
236 increments
4F If the clothes are not dry enough, add increments by using the
“count up” button: 31,32,33,34,.....3A,3b,3C,3d... etc. up to F0
3F
30 = P3
2F
1F
15
05
487 21 98 61 - 290,530,650 - GB
Programming 11
Parameter- Value/setting
number Man. Man. *Coin *CP
RMC Time Machine types.
50 10 11/51 12 W/o rev.
00. 70 30 31/71 32 W/ rev. Standard and condensate versions.
487 21 98 61 - 290,530,650 - GB