ETAP - Load Flow Analysis Using

ETAP's advanced Load Flow module enables users to create and validate electrical system models efficiently, providing accurate calculations of bus voltages, power flows, and branch power factors. The software supports various power sources and configurations, allowing for simultaneous analysis of multiple scenarios and detailed reporting. Key features include automatic device evaluation, extensive violation alerts, and intelligent graphics for result visualization.

Uploaded by

manuel santiago
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views26 pages

ETAP - Load Flow Analysis Using

ETAP's advanced Load Flow module enables users to create and validate electrical system models efficiently, providing accurate calculations of bus voltages, power flows, and branch power factors. The software supports various power sources and configurations, allowing for simultaneous analysis of multiple scenarios and detailed reporting. Key features include automatic device evaluation, extensive violation alerts, and intelligent graphics for result visualization.

Uploaded by

manuel santiago
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 26

Load Flow Analysis using etap

Create & Validate System Models with Ease


& Accuracy

 With ETAP’s advanced Load Flow module, you can


create and validate your system model with ease and
obtain accurate and reliable results. Built-in features like
automatic device evaluation, summary alarms /
warnings, result analyzer, and intelligent graphics make it
the most efficient Load Flow program available today.
 ETAP calculates bus voltages, branch power factors,
currents, and power flows throughout the electrical
system. ETAP allows for swing, voltage regulated, and
unregulated power sources with multiple power grids
and generator connections. It is capable of performing
analysis on both radial and loop systems. ETAP allows
you to select from several different methods in order to
achieve the best calculation efficiency and accuracy.
 Voltage Drop
 Power Factor Correction
 Automatic Device Evaluation
 Automatic Temperature Correction
 2W & 3W Transformer LTC /
Regulator Actions
 Real & Reactive Power Losses
 Auto-Run Based on System
Changes
 Extensive Violation Alerts
 Multi-Report Result Analyzer
Intelligent Graphics: State-of-the-art graphical
display of results including voltage drop, load
terminal voltage, branch losses, and transformer
LTC settings
Most Efficient Load Flow Program Available

Study Options
 • Option to update initial conditions
 • Phase-shifting transformers
 • Auto-adjust LTC / regulator settings
 • Power factor correction
 • Saves solution control parameters for
each scenario

 3-Phase and 1-Phase Power Flow: Calculate


power flow for 3-phase, 1-phase, panel,
and UPS systems simultaneously
Study Options

 • Make changes to your system & re-run studies instantly


 • Conduct unlimited “what if” studies within one database
 • Calculate bus voltages, currents, & power factors
 • Bus / transformer / cable reactor overload warnings
 • Calculate power flows
 • Update loading for DC load flow
 • Voltage drop calculations
 • Five levels of automatic error checking
Capabilities
 • Simulate multiple loading & generation conditions
 • Automatically adjust transformer tap & LTC / regulator settings
 • User-controlled convergence parameters
 • Compare & analyze multiple reports using result analyzer
 • Include effect of phase-shifting transformers
 • View results graphically
 • Evaluate critical & marginal limit violations
 • Solve 3-phase & 1-phase system load flow simultaneously
 • Isolated 1-phase source modeling
 Load Flow Analysis
Flexible Operation

 • Diverse operating conditions


 • Multiple loading categories
 • Multiple demand factors
 • Different model of lumped loading
 • Unlimited configurations
 • Different nameplate data
 • Global & individual bus diversity factors
Automatic Device Evaluation: Automatically generate critical and marginal alerts for overstressed 3-
phase and 1-phase systems
Simultaneous Analysis of Different
Scenarios
 Load Flow Result Analyzer
 ETAP Load Flow Result Analyzer is a time-saving tool that compares and
analyzes multiple reports in a single view. You can compare the results of
general information about a project or more specific information such as
the load flow results for buses, branches, loads, or sources.
Detailed Modeling with Accurate Results
 Reporting
 • State-of-the-art graphic display of results
 • Customize output reports using Crystal Reports®
 • Generate output reports in any language
 • Voltage drops, losses, power flows, power factor, etc.
 • Input data, detailed load flows, & summaries
 • Export reports to your favorite word processing program
 • Graphically display device evaluation results
 • Graphically display buses with marginal or critical under / over
voltage
 • Export one-line diagrams including results to third party CAD
systems
 • Alert view to display critical & marginal limit violations
Extensive Reporting: Detailed load flow reports and indispensable summaries
including branch losses, voltage drop, and loading
• Understand results of multiple studies in one glance
• Compare & view multiple load flow results in a single view
• Analyze & compare reports from multiple projects
• Create a base line report & quickly identify deviations for all cases
• View multiple bus, branch, load, & source results
• Advanced alert & warning feature identifies & highlights overstressed
components
• Easily find components on one-line diagrams from the analyzer view
• Export summary view into Microsoft® Excel for maximum data
flexibility & visualization
Features
 • Newton-Raphson, fast decoupled, & accelerated Gauss Seidel
 • Generator governors with isochronous or droop mode
 • Generator exciters with AVR or Mvar / PF controllers
 • Transformer load tap changers (LTC / regulators)
 • Advanced solution techniques for fast convergence
 • Multiple loading conditions
 • Multiple generation conditions
Features
 • Swing, voltage regulated, & unregulated power sources
 • Voltage drop calculations
 • Load forecasting
 • Alert view to display critical & marginal limit violations
 • Bus / transformer / cable overload warning
 • Single-phase load flow display
 • Global & individual bus diversity factors
 • Individual demand factors for continuous, intermittent, &
spare operating conditions
 • Option to update the initial condition from load flow
solutions
Features
 • Phase-shifting transformer
 • Power factor correction
 • Multi-report result analyzer
 • Unlimited bus capability
ETAP Desktop
Instruments
CT’s, VT’s, Relays, …….
AC Elements
Generators, Loads,
Motors, transformers ,……

DC Elements
UPS, VFD, Inverters,
……
Protective
devices
CB’s, Fuses, Contactors,
…..
END