0% found this document useful (0 votes)
6 views1 page

Brief 2

The document outlines the space layout and requirements for a Marine Research Centre, detailing various office areas, meeting zones, visitor facilities, and utility zones. It emphasizes accessible design, furniture specifications, and compliance with workplace regulations, including temperature control and ventilation. Additionally, it includes information on outdoor spaces and parking arrangements to accommodate visitors and staff.

Uploaded by

Fridah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views1 page

Brief 2

The document outlines the space layout and requirements for a Marine Research Centre, detailing various office areas, meeting zones, visitor facilities, and utility zones. It emphasizes accessible design, furniture specifications, and compliance with workplace regulations, including temperature control and ventilation. Additionally, it includes information on outdoor spaces and parking arrangements to accommodate visitors and staff.

Uploaded by

Fridah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BRIEF ANALYSIS: MARINE RESEARCH CENTRE

4 OFFICES.
SPACE LAYOUT SPACE DESCRIPTION FURNITURE REQUIREMENTS DESIGN REQUIREMENTS USERS
600
SECRETARY
3,000
1,600
AREA 01
800
SECRETARY AREA 02
Visitor,employee, researcher check-ins Desks (1524 x 762 mm), Accessible design for ease of use by T.AREA
3,800
800 375 625 860
600 2,400 800 all visitors, including those with * T.Area- Total Area.

Office chair (600mm x 450mm) disabilities.


Waiting

860
Rooms = 2
Access Waiting

625
Access
3,660

A welcoming atmosphere with

860
4,145
Desk Area

Filing cabinets (600mm x 900mm) Area = 24 Sq.m


Setback

Access

1,000

Desk Area

comfortable seating and appropriate

1,800
Setback

Access
3.6x3m + 1.5sqm circulation
3.6x4.15m + 1.5sqm circulation
600mm by 1800mm benches lighting to ensure a good first
Reception Layout 1. Reception Layout 2. impression.
A 12 sq.m B 16 sq.m
Offices will be at land and
NB; Referenced from Architect's Data some at sea
Ernst Neufert

SINGLE WORK STATION


SINGLE WORK STATION WITH CORNER
ATTACHMENT According to the new Workplace Work area: table The room temperature should be Scientist
600
3,000
1,600 800 600 800
3,800
1,600 800 Regulations, there are no longer any min. 19°C and max. 26°C (legal Rooms = 20
fixed minimum dimensions for work Shelf area: plan area of the furniture. interpretation of the Workplace
800

800

Area = 400
Desk Area Desk Area
1,800

1,800
Setback

Setback
Access

Access

places. Regulations)
1,000

1,000

Sq.m
3x1.8m + 1.5sqm circulation

Office Layout 1.
3.8x1.8m + 1.5sqm circulation

Office Layout 2. The standard requires sufficient working Furniture function area: space required for
C 7 sq.m D 7 sq.m doors and drawers For archive rooms the rooms must be
and movement areas for changing positions dry, so attic and cellar are inadvisable. Management
MEETING ZONE
SPACE FOR CABINETS at work and for the individually adaptable
Movement area at the workstation Rooms = 20
placing of work equipment.
800

900
2,400

Area = 400
800
Setback

400 600 400

Traffic and through-passages


800

300 2,400
1,400 Spaces will be assigned to scientists and management offices.
Sq.m
2,700
Office Cabinets.
Meeting Zone F 1.3 sq.m
E 6.5 sq.m NB; Referenced from Architect's Data
Offices will be at land and
Ernst Neufert some at sea

CONFRENCE ROOM 600mm x 450mm Ergonomic office chairs Compliance: Ensure the room
8,200 A space for conducting meetings complies with accessibility standards,
Rooms = 4
500

800mm x 4000mm Conference table accommodations for individuals with


Area = 148
1,240

800

1,000

disabilities.
4,480

600 1,500 4,000 1,300 600


4,280
800

450mm x 2700mm side bench Sq.m


storage
1,240

Signage: Use clear, visible signage to


500

600mm x 900mm office cabinets guide users to the conference room


G
Conference Room.
37 sq.m NB; Referenced from Architect's Data
and within it.
Ernst Neufert

Auditorium Size of auditorium: the number of people in Seats (450mm x 450mm) Good view, without moving head, Users = 200
the audience gives the required floor area. but light eye movements of approx.
Projection screen Area = 100
For seated spectators, assume :0.5 m2 / 30°.
Sq.m
spectator.
Full head and shoulder movement
Length of the rows of seats per aisle: 10 allows an angle of view of 360°.
places.
25 places per aisle if an exit door of 1.2 m Audiovisual equipment must be
width is available at the side per 3 or 4 rows high-quality for clear presentations.
Exits, routes 1.2 m wide per 200 people Wall acoustic traetments
1% of the seats (at least two) must be
accessible for wheelchair users,

5 VISITOR CENTRE
6,800

Waterboil
Preparation of employee and visitors meals. Countertops, island or prep stations, stoves Install proper ventilation systems to Rooms= 2
and ovens, microwaves and toasters, handle cooking fumes and maintain
Meat Deep fat
598

Placing Placing er Warmers


Preparation Griddle Griddle fryer
1,000

598 802 600 600 600 600 600 600 600 402 598
Area = 82 Sq.m
cabinets, pantries, refrigerators and freezers, air quality.
& Transfer
Sorting
1,002

cutting boards, kitchen carts, tables and


Install proper lighting
1,400

6,693

chairs, sinks, a dishwasher, garbage and


placing RG RG
vice counter
Seating/Ser
placing

placing

1,200

recycling bins and shelving units


To
Low level
600

6,100
F

worktop
Oven
5,910

Dishwashe
with

600 1,100 600 750 750 1,000 100 1,120 580 100
600

r
Preparation

600
Dough

Waterboiler
Veg Preparation
From Store
Washing
2,298
Crockery
Shelving

1,200

Potato peeling /
Large utensil wash
& Sorting
Returns

Splash
back

800
exit/store
600

Crockery Receiving
To

for wash
Sizes can be adjusted based on the
Kitchen number of units and additional
One at sea, one at land
A 41 sq.m NB; Referenced from Architect's Data equipment requirements
Ernst Neufert

1,475
2,600 2,360
Eating, relaxing 800mm x 800mm Ergonomic Tables Seating capacity that accommodates Users = 150
peak visitor times. Area = 225
2,040
2,200

450mm x 450mm Ergonomic Chairs


2,550

Sq.m
Scenic views to enhance visitor
Dining 1 Dining 2 Dining 3
B1 4 sq.m B2 6 sq.m B3 5 sq.m experience.
Sizes can be adjusted based on the
NB; Referenced from Architect's Data
number of units and additional
Ernst Neufert equipment requirements One at sea, one at land

Art gallery: Collection of works of fine art Art


1,000 1,200
The size and height of the display
150

Through
passage
(including craftworks and graphics). Display windows, if available and dimensions of the works and the
1,500

width
Users = 200
Distance
extent of the collection.
1,200

Area = 264
depends on
picture size

Science Gallery: Collection of educational


Sq.m
1,200

Exhibition 1 Exhibition 2 and display material connected with Sizes can be adjusted based on the
number of units and additional
The minimum height is 4 m clear.
C1 C2 KMFRI Mombasa
scientific and technical themes. equipment requirements One at sea, one at land
150

350mm by 1800mm Shelving for Attractive and organized display of Users = 4


650

Selling sea artifacts, food oulets merchandise displays products to encourage sales.
Area = 172
1,800

Sq.m
650 650

Cashier station.
6,200
1,800
650
150

150 4,150 1,800 650 150


6,900

Retail shop One at sea, one at land


D 43 sq.m
NB; Referenced from Architect's Data
Ernst Neufert

6
Utility Zones.

An outdoor space for conducting events Waste bins Well ventilated


Users = 1
150

Rubbish Room
Accessible from all spaces Area = 16 Sq.m
3,400

Fire Retarted Direct to open air


self closing door

150 4,600 150


150

Rubbish Collection room


A 16 sq.m NB; Referenced from Architect's Data
Ernst Neufert

Sizes can be adjusted based on the


Generator Rooms Back up generator number of units and additional
equipment requirements

2,000
1,500
2,100
300
For 100 employees: Disability-friendly toilets A lobby with washbasins (at least Users = 10
Men: 5 WCs, 5 urinals, 2 washbasins, one washbasin per five water closets)
300 600 600 300
0.450
1,000

Area = 16 Sq.m
2,000

1 wastebin.
300
1,000

Urinals must be placed and not be


1,970

Water Closets (WC)


600 600

PWD Normal Bathroom sink visible from the entrance.


B 4 sq.m
C 1.5 sq.m
D 4 sq.m Women: 7 WCs, 2 washbasins, 1
wastebin. Urinals (For Men) Toilet cubicles must be lockable.
With window ventilation on one side
Washbasins 1700 cm2/WC, 1000 cm2/urinal;.
NB; Referenced from Architect's Data
Ernst Neufert

7 OUTDOOR SPACES
Users = 500
Scenic open views to enhance visitor Area = 250
Outdoor Amphitheatre An outdoor space for conducting events Concrete landscaped seats 0.5 sq.m per person
experience. Sq.m
Parking 10,500
NB; Referenced from Architect's Data
Ernst Neufert

5,000 5,500
1,525

3,700
2,500
2,900

4,025
4,400

2,500

5,000 5,500

10,500
1,500

8,500

Car Parking PWD Car Parking Boat Parking


13,900 14,000
B C 42 sq.m
D 31 sq.m
26 sq.m
27,900

Bus Parking
A 123 sq.m Users = 5 buses Area = 615 Sq.m Users = 40 cars Area = 1040 Sq.m Users = 5 cars Area = 210 Sq.m Users = 10 boats Area = 310 Sq.m

Total Area = 8055 Square Metres


Total Area = 8055 x 10% (Landscaping)= 806 Square Metres Total Area = 10473 Square Metres

Total Area = 8055 x 20% (Circulation)= 1612 Square Metres

KIBET NICHOLAS BARC/091J/2018 TECHNICAL UNIVERSITY OF MOMBASA: DEPARTMENT OF ARCHITECTURE


GSPublisherVersion 0.0.100.100

You might also like