User Manual
Note that to undertake the following programming the master user must be logged in
1 Read Card #
To add a card user Cards can be added continuously without exiting
programming mode
To unlock the door for a PIN user Enter the PIN then press #
4.Features
Waterproof, conforms to IP65/IP68
Strong Zinc Alloy Electroplated anti-vandal case
Full programming from the keypad
2000 uses, supports Card, PIN, Card + PIN
Can be used as a stand alone keypad
Backlight keys
Wiegand 26 input for connection to external readerWiegand 26 output for connection to a controller
Adjustable Door Output time, Alarm time, Door Open time
Very low power consumption (30mA)
Fast operating speed, <20ms with 2000 users
Lock output current short circuit protection
Easy to install and program
Built in light dependent resistor (LDR) for anti tamper
Built in buzzer
Red, Yellow and Green LEDS display the working status
5.Specifications
Operating Voltage DC12-24V
User Capacity 2000
Card Reading Distance 3-6 cm
Active Current 60mA
Idle Current 25±5 mA
Lock Output Load Max 1A
Alarm Output Load Max 20A
Operating Temperature -4560
Operating Humidity 10%- 90% RH
Waterproof Degree IP65/IP68
Adjustable Door Relay time 0 -99 seconds
Adjustable Alarm Time 0- 3 minutes
Wiegand Interface Wiegand 26 bit
Wiring Connections Electric Lock, Exit Button, External Alarm
6.Installation
Remove the back cover from the keypad using the supplied special screw driver
Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
Put the supplied rubber bungs to into the two holes
Fix the back cover firmly on the wall with 2 Self tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover.
7.Wiring
Colour Function Description
Pink BELL_A Doorbell button one end
Pink BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Gray ALARM Alarm negative(alarm positive connected 12 V+)
Yellow OPEN Exit button one end(the other end connected GND)
Brown D_IN Magnetic switch one end(the other end connected GND)
Red 12V+ 12V + DC Regulated Power Input
Black GND 12V - DC Regulated Power Input
Blue NO Relay normally-on end(Connect positive electric lock "-")
Purple COM Relay Public end, connect GND
Orange NC Relay Closed end(connect negative electric lock "-")
Pink
Pink
Doorbell
DC12V
Pink
Pink
Doorbell
DC12V
8.To Reset to Factory Default
a. Power off
b. Press and hold # key whilst powering on
c. On hearing tick twice release # key, system is back factory settings now
Registered users won’t be deleted when reset to factory default
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code # New code #
The master code can be 6 to 8 digits long
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
2 User ID number #
To delete a PIN user Users can be deleted continuously without exiting
programming mode
To Add a card and Pin user Add the card as for a card user
(The PIN is any four digits between Press to exit from the programming mode
0000 & 9999 with the exception of Then allocate the card a PIN as follows:
1234 which is reserved.) Read card 1234 # PIN # PIN #
11.2Door Settings
Relay Output Delay Time
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN
numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and
the inside buzzer will operate for 10 minutes, depending on the option selected below.
Keypad Lockout 7 1 #
To reset the Door Forced Open warning Read valid card or Master Code #
To reset the Door Open Too Long warning Close the door or Read valid card or Master Code #
12.The unit operating as a Wiegand Output Reader
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any
controller which supports a Wiegand 26 bit input.
Pink
Pink
Doorbell
DC12V
Access Controller