Fronius Data Logger Web Configuration Guide
Fronius Data Logger Web Configuration Guide
42,0426,0064,EA
01/2012
Dear reader,
Introduction Thank you for the trust you have placed in our company and congratulations on buying this high-quality Fronius product. These instructions will help you familiarize yourself with the product. Reading the instructions carefully will enable you to learn about the many different features it has to offer. This will allow you to make full use of its advantages. Please also note the safety rules to ensure greater safety when using the product. Careful handling of the product will repay you with years of safe and reliable operation. These are essential prerequisites for excellent results.
Contents
General ...................................................................................................................................................... General ................................................................................................................................................. Applicable DATCOM components ........................................................................................................ Prerequisites for operation.................................................................................................................... Required Inverter Software ................................................................................................................... Scope of supply .................................................................................................................................... Controls, connections and indicators ......................................................................................................... Safety.................................................................................................................................................... Controls, connections and indicators .................................................................................................... Installing Fronius Datalogger Web............................................................................................................. Safety.................................................................................................................................................... Configuration examples ........................................................................................................................ Preparation ........................................................................................................................................... Installing 'Fronius Datalogger Web' ...................................................................................................... Fronius Datalogger Web network configuration ......................................................................................... General ................................................................................................................................................. Requirements........................................................................................................................................ 'Fronius Datalogger Web' network configuration .................................................................................. Installing Fronius Datalogger Web and going to the Fronius Datalogger Web homepage................ Entering network data ........................................................................................................................... Setting 'Fronius Datalogger Web' for the WLAN connection ................................................................ Setting the IP address and connecting 'Fronius Datalogger Web' to the network ................................ Network settings for PC/laptop .................................................................................................................. General ................................................................................................................................................. Network settings for PC/laptop ............................................................................................................. Internet options for PC/laptop ............................................................................................................... Connecting to 'Fronius Datalogger Web' via Internet browser ................................................................... General ................................................................................................................................................. Requirements........................................................................................................................................ Connecting to 'Fronius Datalogger Web' via Internet browser.............................................................. For the network administrator ............................................................................................................... Connecting to 'Fronius Datalogger Web' via 'Fronius Solar.access' .......................................................... General ................................................................................................................................................. Requirements ....................................................................................................................................... Connecting to 'Fronius Datalogger Web' via 'Fronius Solar.access'..................................................... For the network administrator ............................................................................................................... Connecting to 'Fronius Datalogger Web' via the Internet and 'Fronius Solar.web' .................................... General ................................................................................................................................................. Function overview ................................................................................................................................. Requirements ....................................................................................................................................... Accessing data from 'Fronius Datalogger Web' via the Internet and 'Fronius Solar.web'..................... For the network administrator ............................................................................................................... Calculating the data volume....................................................................................................................... General ................................................................................................................................................. Firmware versions for calculating the data volume............................................................................... Calculating the data volume.................................................................................................................. Calculation examples............................................................................................................................ General information for the network administrator ..................................................................................... General firewall settings........................................................................................................................ Sending service messages via a DSL Internet connection................................................................... Using 'Fronius Solar.web' and sending service messages ................................................................... 'Fronius Datalogger Web' views................................................................................................................. Overview ............................................................................................................................................... Current total view .................................................................................................................................. Current comparison view ...................................................................................................................... 'Fronius Datalogger Web' settings ............................................................................................................. Overview ............................................................................................................................................... Accessing and editing selection options ............................................................................................... Passwords ................................................................................................................................................. General ................................................................................................................................................. 5 5 5 5 6 6 7 7 7 9 9 9 10 10 11 11 11 11 12 13 16 18 19 19 19 21 23 23 23 23 23 24 24 24 24 25 26 26 26 26 27 27 28 28 28 28 29 31 31 31 31 32 32 32 33 34 34 34 35 35
Passwords ............................................................................................................................................ User password ...................................................................................................................................... Administrator Password ........................................................................................................................ Forgot Your Password? ........................................................................................................................ Time/Date .................................................................................................................................................. General ................................................................................................................................................. Time/Date ............................................................................................................................................. Views ......................................................................................................................................................... General ................................................................................................................................................. Views .................................................................................................................................................... 'General' view........................................................................................................................................ Inverter views........................................................................................................................................ Sensor Card views................................................................................................................................ Logging ...................................................................................................................................................... General ................................................................................................................................................. Logging ................................................................................................................................................. Memory capacity................................................................................................................................... Calculating memory capacity ................................................................................................................ Calculation example.............................................................................................................................. Overwriting data when memory is full ................................................................................................... Delete Data button .............................................................................................................................. Network...................................................................................................................................................... General ................................................................................................................................................. Network................................................................................................................................................. Network diagnostics.............................................................................................................................. Solar.web ................................................................................................................................................... General ................................................................................................................................................. Solar.web .............................................................................................................................................. Daily data transmission to Solar.web.................................................................................................... Hourly data transmission to Solar.web ................................................................................................. Service messages...................................................................................................................................... General ................................................................................................................................................. Service messages................................................................................................................................. System information .................................................................................................................................... General ................................................................................................................................................ System information ............................................................................................................................... Firmware update ........................................................................................................................................ General ................................................................................................................................................. Automatic update search ...................................................................................................................... Manual update search .......................................................................................................................... Firmware update via web...................................................................................................................... Firmware update via LAN ..................................................................................................................... Technical data............................................................................................................................................ Technical data.......................................................................................................................................
35 35 36 36 37 37 37 39 39 39 39 40 41 42 42 42 42 42 43 43 44 45 45 45 46 47 47 47 47 47 48 48 48 51 51 51 52 52 52 52 53 54 55 55
General
General The 'Fronius Datalogger Web' is a network-compatible Datalogger. The 'Fronius Datalogger Web' website provides a quick overview of the PV system. The website can be accessed via a direct connection from the Intranet or with the proper configuration via the Internet. The 'Fronius Datalogger Web' is equipped with an easy-to-configure system monitoring feature with an automatic alarm. The alarm can be signaled via SMS, e-mail, fax, relay contact or buzzer. When connected to 'Fronius Solar.access,' realtime PV system data as well as archived data can be saved to a PC and analyzed. You can also make settings to all devices in 'Fronius Solar Net.' When connected to 'Fronius Solar.web,' realtime PV system data as well as archived data can be easily accessed via the Internet - no difficult configuration required. Data is sent automatically from 'Fronius Datalogger Web' to 'Fronius Solar.web.'
'Fronius Datalogger Web' can be used with the following DATCOM components: - Up to 100 - Up to 10 - Up to 10 - Up to 1 - Up to 200 x Fronius IG Plus, Fronius IG or Fronius CL inverters x 'Fronius Sensor Cards' or 'Fronius Sensor Boxes' x 'Fronius Public Display Cards' or 'Fronius Public Display Boxes' x 'Fronius Interface Card' or 'Fronius Interface Box' x 'Fronius String Controls'
The inverter requires a 'Fronius Com Card' in order to operate 'Fronius Datalogger Web.' For a proper function of the Fronius Datalogger Web an appropriate Internet connection is required: For cable-bound internet solutions Fronius recommends a download speed. of min. 512 kBit/s and an upload speed of min. 256 kBit/s. For solutions with mobile internet services Fronius recommends min. 3G transmission standard with a reliable signal strength. This information does not constitute an absolute guarantee of proper operation. High error rates in the transmission, reception fluctuations or transmission interruptions can affect the online operation of the 'Fronius Datalogger Web' in a negative way. Fronius recommends testing connections with minimum requirements on site.
The correct display of daily energy using Fronius Datalogger Web requires the following inverter software versions: Inverter Fronius IG 15 - 60 Fronius IG 2000 - 5100 Fronius IG 300 - 500 Fronius IG Plus 35 - 150 Required software version according to display (MainControl) V2.9.4 or higher starting from series no. 19153444 V3.6.4.0 or higher V4.22.00 or higher
The respective inverter software version can be downloaded for free from our homepage (http://www.fronius.com). Please use a Fronius Update Card to update inverter software. If you have any questions, please contact [email protected].
Scope of supply
1 x 'Fronius Datalogger Web' Datalogger with wall mounting device 1 x 'Safety' leaflet 1 x 'Quick Installation' leaflet 1 x Ethernet cable 5 m, blue 1 x Solar Net cable 2 m, red 2 x Terminating plugs 2 x Installation anchors + screws 1 x 'Fronius Solar.access' CD 1 x Relay plug 1 x Relay connector housing 1 x Sticker set
(2)(1)
(8)
(9)
(10)
(11)
(12)
(13)
Solar Web connection LED lights up green: when there is an existing connection to 'Fronius Solar.web' lights up red: when there is no connection to 'Fronius Solar.web' but one is required does not light up: when no connection to 'Fronius Solar.web' is required Supply LED lights up green: when there is sufficient power coming from 'Fronius Solar Net' - 'Fronius Datalogger Web' is operational does not light up: when there is no power or not enough power coming from 'Fronius Solar Net' - an external power source for 'Fronius Datalogger Web' is required flashing red: during updating IMPORTANT Do not interrupt the power supply while updating. lights up red: the update process failed
(2)
(3)
Relay connection Equipped as an NCC (normally closed contact) and NOC (normally open contact), switches when there is an error Connection LED lights up green: when there is an active connection within 'Fronius Solar Net' lights up red: when there is an interrupted connection within 'Fronius Solar Net' WLAN LED lights up green: when there is a network connection lights up red: when there is no network connection does not light up: the WLAN stick is not inserted
(4)
(5)
No. Function (6) Alarm switch for switching the alarm function on/off Alarm off: Alarm function, relay and buzzer deactivated Alarm on: Alarm function, relay and buzzer activated; when 'Alarm on' is selected, the buzzer and relay are briefly activated as a test of the alarm function (7) IP address switch used to switch from an assigned IP address to a default IP address '169.254.0.180' (only relevant to LAN) Assigned IP: 'Fronius Datalogger Web' operates using an assigned IP address (factory setting 192.168.1.180). The IP address can be set on the 'Fronius Datalogger Web' website 169.254.0.180: 'Fronius Datalogger Web' operates using a fixed IP address 169.254.0.180; the fixed IP address is used for a direct connection to a PC without having to pre-configure the PC (8) (9) LAN connection Ethernet interface colored blue for connecting an Ethernet cable USB connection USB interface for connecting the WLAN stick or WLAN stick outdoor options
(10) Power supply connection 12 V DC / 1 A, electronic fuse protection for supplying power to external components (e.g., external routers) (11) External power supply connection for connecting an external power supply when the power supply within 'Fronius Solar Net' is insufficient (e.g., when too many DATCOM components are installed in 'Fronius Solar Net'). Important The external power supply unit for the Fronius Datalogger Web must have a secure disconnect between components supplying grid voltage (SELV or Class 2 for USA/Canada). The output of the power supply unit may not exceed a max. of 15 VA / 1.25 A. If the power supply is sufficient, the Supply LED (2) lights up green. (12) Solar Net IN connection Fronius Solar Net input colored red for connecting other DATCOM components (e.g., inverters, sensor cards) (13) Solar Net OUT connection Fronius Solar Net output colored red for connecting other DATCOM components (e.g., inverters, sensor cards)
Configuration examples
Inverter
PC / Laptop
'Fronius Datalogger Web' networks with several inverters, a 'Fronius Sensor Box' and a PC:
Inverter 1
Inverter 2
Inverter 3
IN
OUT
PC / Laptop
OUT OUT IN
NOTE! When networking several DATCOM components, a termination plug must be placed on each free IN and/or OUT connection of a DATCOM component.
Preparation
IMPORTANT Please follow the operating instructions for the inverter as well as the 'Fronius IG DATCOM Detail' operating instructions.
Install 'Fronius Datalogger Web' in the proper position using the screws and installation anchors provided in the scope of supply Insert the red Solar Net cable into the Solar Net output (OUT) of the 'Fronius Com Card' If the 'Fronius Com Card' is the last DATCOM component in the network: Insert a terminating plug into the Solar Net OUT connection
IN
OUT
CAUTION! DATCOM components and/or the PC/laptop will be damaged if the Ethernet or Solar Net cables are connected incorrectly. The Ethernet cable should only be inserted into the LAN connection (colored blue) The Solar Net cable should only be inserted into the Solar Net IN or Solar Net OUT connections (colored red)
1 2
Insert the red Solar Net cable into the Solar Net output (OUT) of the 'Fronius Com Card' If the 'Fronius Com Card' is the last DATCOM component in the network: Insert a terminating plug into the Solar Net OUT connection If there are additional DATCOM components in the network after the 'Fronius Datalogger Web': Insert an additional Solar Net cable into the Solar Net OUT connection
3 4
Insert the blue Ethernet cable into the LAN connection Insert the blue Ethernet cable into the PC/laptop or into a corresponding network connection
10
Requirements
NOTE! The network configuration of the 'Fronius Datalogger Web' Datalogger requires knowledge of network technology. If the 'Fronius Datalogger Web' is being integrated into an existing network, the 'Fronius Datalogger Web' address must be adapted to the network. Example: Network address range = 192.168.1.x, subnet mask = 255.255.255.0 An IP address between 192.168.1.1 and 192.168.1.254 must be assigned to the 'Fronius Datalogger Web.' The IP address selected may not be already assigned in the network. The subnet mask must correspond to the existing network (e.g., 255.255.255.0).
If the 'Fronius Datalogger Web' will be sending service messages and/or data to 'Fronius Solar.web,' then a gateway address and a DNS server address must also be entered. 'Fronius Datalogger Web' uses the gateway address to access the Internet. The IP address of the DSL router can be used as a gateway address, for example. IMPORTANT 'Fronius Datalogger Web' may not have the same IP address as the PC/laptop. 'Fronius Datalogger Web' cannot connect by itself to the Internet. A router must be used for a DSL connection to the Internet. If the network connection uses WLAN, then one of the following options is required: WLAN stick (41,0018,0070) WLAN stick outdoor (41,0018,0071)
The Fronius Datalogger Web network configuration comprises the following steps: Installing Fronius Datalogger Web and going to the Fronius Datalogger Web homepage Entering network data Setting 'Fronius Datalogger Web' for the WLAN connection Setting the IP address and connecting 'Fronius Datalogger Web' to the network
11
Installing Fronius Datalogger Web and going to the Fronius Datalogger Web homepage
1 2
Only if you are using the WLAN network connection: connect the WLAN stick or WLAN stick outdoor option to the USB port Install 'Fronius Datalogger Web'
Wait approx. 1 minute until the 'Connectivity' icon appears in the PC/laptop taskbar.
5 6
Open the PC's/laptop's Internet browser (e.g., Microsoft Internet Explorer) Enter 'http://169.254.0.180' in the address field The 'Fronius Datalogger Web' website will appear.
12
http://169.254.0.180
13
To define the Internet connection (e.g., to Fronius Solar.web): Click on 'Internet connection' The Internet connection settings are displayed.
(1)
(2)
*)
*)
WLAN can only be used when one of the two options (WLAN stick or WLAN stick outdoor) is inserted in the Fronius Datalogger Web. Select the type of Internet connection (LAN or WLAN) (1) Click on 'Save' (2) After the changes have been loaded, the message 'Changes have been applied' is displayed.
4 5
Click on 'OK' The Internet connection data are displayed. IMPORTANT You may also have to enter a gateway and a DNS server depending on the Internet connection option selected. For example, if 'LAN' was selected for the Internet connection, a gateway and a DNS server must be entered for the 'LAN' interface.
Click on 'LAN' or 'WLAN' in the 'Network' submenu depending on the network connection interface you are using. The interface settings are displayed (LAN or WLAN).
(3)
(4)
14
Select either a static or dynamic IP address (3) Obtain IP address statically (factory setting): The user enters a fixed (static) IP address for the 'Fronius Datalogger Web' and also manually sets the subnet mask, gateway address and the DNS server address (from provider). Obtain IP address dynamically: Obtain IP address dynamically: The 'Fronius Datalogger Web' obtains its IP address from a DHCP server (DHCP = dynamic host configuration protocol). The DHCP server must be configured so that the 'Fronius Datalogger Web' is always assigned the same IP address. This enables you to always know under which IP address the 'Fronius Datalogger Web' can be reached. If the DHCP server supports the 'DNS dynamic updates' function, a name can be entered for the 'Fronius Datalogger Web' in the 'Hostname' field. The connection to the 'Fronius Datalogger Web' can then take place via the name instead of the IP address. Example: Hostname = samplesystem, Domain name = fronius.com The 'Fronius Datalogger Web' can be accessed via the 'samplesystem.fronius.com' address
Click on 'Save' (4) After the changes have been loaded, the message 'Changes have been applied' is displayed.
10 Click on 'OK'
The interface settings are displayed (LAN or WLAN).
15
The following steps are only required if you decide to use the WLAN network connection at a later date.
1 2 3
Click on 'WLAN' in the 'Network' submenu. Enter the settings for the WLAN interface Click on 'WLAN management' in the 'Network' submenu. WLAN management is displayed with the available networks (1).
(1)
(2)
(3)
4 5 6
Click on 'Update' (2) to update the networks Select a suitable network by clicking on it Click on 'Configure Network' (3). 'Configure Network' is displayed.
(7)
7 8
Enter the SSID network name (4) Enter the encryption type (5): none = no encryption WEP = hexagonal encryption WPA1/2 = encryption via pass phrase (8 - 63 ASCII characters) Only if WEP or WPA1/2 encryption has been selected: enter the corresponding pass phrase / key (6)
16
11 Click on 'OK'
WLAN management is displayed.
(8)
(9)
You can use the arrow keys (8) and the Save Order key (9) to change the sequence of displayed networks.
17
Setting the IP address and connecting 'Fronius Datalogger Web' to the network
Set the IP address switch on the 'Fronius Datalogger Web' to 'assigned IP'
Connect 'Fronius Datalogger Web' to the respective network via the LAN or WLAN connection
18
1 2
Start / Control Panel / Network and Internet Connections Double-click on 'Network Connections'
5 6
19
20
If a DHCP server is not available in the network: 7a Select 'Use the following IP address' 7b Assign a unique IP address to the PC/laptop Example: Network address range = 192.168.1.x, subnet mask = 255.255.255.0 An IP address between 192.168.1.1 and 192.168.1.254 must be assigned to the PC/laptop. The IP address selected may not be already assigned in the network. The subnet mask must correspond to the existing network (e.g., 255.255.255.0). The 'Default gateway' setting is not relevant to the 'Fronius Datalogger Web' connection.
IMPORTANT The PC/laptop must not have the same IP address as the 'Fronius Datalogger Web.'
1 2 3
Open the Internet browser (e.g., Microsoft Internet Explorer) Click on 'Tools' Click on 'Internet Options'
21
When the 'Use a proxy server for your LAN' option is not activated like in the picture, the setting options below it are grayed and not accessible. When 'Use a proxy server for your LAN' is activated: Click on 'Advanced'
www.proxy.exa
Enter the IP address of the 'Fronius Datalogger Web' in the 'Exceptions' field, e.g., 192.168.1.180 Click on "OK"
22
Requirements
At least a LAN or WLAN connection Internet browser (e.g., Microsoft Internet Explorer IE6.0, Firefox 2) PC/laptop in the same network segment as the 'Fronius Datalogger Web'
1 2
Open Internet browser Enter the IP address or the hostname and domain name of the 'Fronius Datalogger Web' The 'Fronius Datalogger Web' website will appear.
http://169.254.0.180
Assign an IP address or hostname as per the section 'Fronius Datalogger Web network configuration'.
To access the Datalogger website outside of the LAN: Configure the network router so that requests are forwarded to port 80/TCP on the Datalogger
23
Requirements
At least a LAN or WLAN connection Internet browser: Microsoft Internet Explorer IE6.0 Network configuration of Datalogger as per section 'Fronius Datalogger Web network configuration' PC/laptop in the same network segment as the 'Fronius Datalogger Web' PC/laptop operating system: Win 2000, Win XP, Win Vista or Win 7 'Fronius Solar.access' software installed on the PC/laptop (the 'Fronius Solar.access' software is included on the CD) Photovoltaic system created in 'Fronius Solar.access' as per 'Fronius Solar.access' online help (Open 'Fronius Solar.access' / Administration / PV Systems / Set up PV System)
*)
*)
1 2 3
Open 'Fronius Solar.access' software Select 'PV Systems' Select the desired photovoltaic system After a brief time, the connection is made to the selected photovoltaic system. 'Online' and the version of the Datalogger will be displayed in the bottom left status bar.
24
To access the Datalogger outside of the LAN: Configure the network router so that requests are forwarded to port 80/TCP and port 15015/TCP on the Datalogger
25
Connecting to 'Fronius Datalogger Web' via the Internet and 'Fronius Solar.web'
General Using the connection to the 'Fronius Datalogger Web' via the Internet and 'Fronius Solar.web,' you can access archived data and realtime PV system data from anywhere via the Internet. In addition, you can also provide other users with guest access so that they can view your photovoltaic system as well as make a comparison of several systems.
Function overview
The Datalogger is connected to the Internet (e.g., via a DSL router). The Datalogger logs on to 'Fronius Solar.web' on a regular basis and sends its saved data every day. 'Fronius Solar.web' can establish active contact with 'Fronius Datalogger Web', e.g., to display realtime data.
Requirements
Internet access Internet browser IMPORTANT 'Fronius Datalogger Web' cannot connect by itself to the Internet. A router must be used for a DSL connection to the Internet.
Registration of photovoltaic system with 'Fronius Solar.web' (1) The Datalogger ID is required for the registration. The Datalogger ID is available in Settings / System Information. In order to access realtime data in Fronius Solar.web, the Yes selection option must be activated under Send current data to Solar.web in Fronius Datalogger Web (2). In order to access archived data in 'Fronius Solar.web,' the 'Daily at' or 'Hourly' selection option must be activated under 'Send archive data to Solar.web' in 'Fronius Datalogger Web' (3).
(1) (2)
(3)
(3)
26
Accessing data from 'Fronius Datalogger Web' via the Internet and 'Fronius Solar.web'
To access realtime and archived data from 'Fronius Datalogger Web' using 'Fronius Solar.web':
1 2
Open the 'Solar Electronics' heading on the Fronius website 'www.fronius.com' Start 'Fronius Solar.web' For more information about 'Fronius Solar.web,' see the online help.
Configure the firewall so that the IP address of the Datalogger can send data to port 49049/ UDP from 'solarweb.fronius.com.' DSL routers mostly enable you to send data to the Internet and, therefore, do not normally have to be configured.
27
The calculation of the data volume is based on the 'Fronius Datalogger Web' firmware version V 2.3.x-x and below. Due to expanded range of functions higher firmware versions may cause a higher data volume.
The calculation of the data volume depends on the active functions of the 'Fronius Datalogger Web'. Function Making available current data within 'Fronius Solar.web' Viewing current data in 'Fronius Solar.web' Data volume singular 1) 150 Byte 32 kByte/h 42 kByte/h + 300 kByte/h 13 kByte/h + 4 kByte/h 0 kByte/h 0 kByte/h
2)
Current total view per sensor card / sensor box Current comparison view per inverter website PV system comparison view
Sending archive data / logging data to 'Fronius Solar.web' Communication of service messages or errors
With daily communication per service message or error With immediate communication per service message or error
1) 2) 3)
only after a data logger reboot or a disconnected internet connection Calculation of the memory sectors per day according to chapter "Logging" section "Calculating memory capacity" depends on the quality of ther internet connection
IMPORTANT! Since the values listed in the table are "raw data" of the 'Fronius Datalogger Web' and due to differences by various counting variants at the providers settlement, increase the calculated total value about 10 - 20 %. If the functions are disabled, no data volume accumulates.
28
An update of the 'Fronius Datalogger Web' firmware also requires a certain data volume. This data volume depends on the size of the update package and can not be considered in the pre-calculation of the data volume.
Calculation examples
Example 1 - home PV system 1 inverter; No sensor card / sensor box; The Fronius Datalogger Web has a 24 h internet connection; + 0,15 kByte + 32 kByte/h x 24 h = 768 kByte
Archive data are sent to the 'Fronius Solar.web'; + 0,6 kByte/min x 30 min = 18 kByte 30 minutes transmission time; Inverter runs 14 h/day; + (1 memory sectors/day x 4 kByte) + 8 kByte 15 minutes save interval; = 12 kByte (according to section Calculating memory capacity 1 memory sector per day results) Current data are daily viewed for 15 minutes Average error rate is assumed to be one service message per day Subtotal without safety + 42 kByte/h x 0,25 h = 10,5 kByte
0,15 kByte 768,00 kByte 18,00 kByte 12,00 kByte 10,50 kByte 1,00 kByte 809,65 kByte
29
Example 2 - industrial PV system 100 inverters; 10 sensor cards / sensor boxes; The Fronius Datalogger Web has a 24 h internet connection; Archive data are sent to the 'Fronius Solar.web'; 120 minutes transmission time; Inverters run 14 h/day; 5 minutes save interval; (according to section Calculating memory capacity 173 memory sectors per day results) The current total view and the current comparison view are daily viewed for 2 h. + 0,15 kByte + 32 kByte/h x 24 h = 768 kByte
+ 0,6 kByte/min x 120 min = 72 kByte + (173 memory sectors/day x 4 kByte) + 8 kByte = 700 kByte
+ 42 kByte/h x 2 h + 300 kByte/h x 10 x 2 h + (13 kByte/h + 100 x 4 kByte/h) x 2 h = 6910 kByte + 50 service messages x 1 kByte = 50 kByte
Average error rate is assumed to be 50 service messages per day Subtotal without safety
0,15 kByte 768,00 kByte 72,00 kByte 700,00 kByte 6910,00 kByte 50,00 kByte 8500,15 kByte
30
Access to the 'Fronius Datalogger Web' website Service messages are sent via Fronius Solar.web.
Normally, no additional router configuration is required for a regular DSL Internet connection for accessing 'Fronius Solar.web' and/or sending service messages, because connections from the LAN to the Internet are open.
However, an Internet connection is required to use 'Fronius Solar.web' and send service messages. 'Fronius Datalogger Web' cannot connect by itself to the Internet. A router must be used for a DSL connection to the Internet.
31
The Current total view contains: PV system power data CO2 savings per day and total Yield per day and total Sensor Card data (if available)
(1)
(1)
(1)
(2)
(2)
Sensor Card data in graphic display (1): the first three measuring channels of Sensor Card 1 are displayed Sensor Card data under graphic display (2): starting with Sensor Card 0, the first four active measuring channels of Sensor Cards available in the system are displayed
32
Several inverters in the same PV system can be compared to each other in the Current comparison view. The realtime inverter AC power is displayed as a percentage of the power from the solar module connected to the respective inverter (shown in a bar diagram). A bar is displayed for each inverter. The bar color indicates the power range of the inverter: Green: Yellow: Red: the inverter power corresponds to the average power of all inverters the inverter power deviates slightly from the average power of all inverters the inverter power deviates strongly from the average power of all inverters or an error has occurred in the inverter
33
*) The Date/Time setting is mandatory The individual selection options will be explained in the following sections.
1 2 3
Connect to 'Fronius Datalogger Web' Click on the 'Settings' menu item Click on the desired selection option The desired selection option will open
4 5
View/Edit selection option If required, click on the respective button (e.g., Save, Synchronize, Update) The changed data are applied.
34
Passwords
General Access to 'Fronius Datalogger Web' is regulated by assigning passwords. There are 2 different password types available: The user password The administrator password IMPORTANT New passwords are only activated when the 'IP address' switch on the Datalogger is set to 'assigned IP.'
Passwords
User password
An assigned user password only gives the user read access to 'Fronius Datalogger Web.' The user cannot open the 'Settings' menu. Users must enter their username and password every time they connect to 'Fronius Datalogger Web.' Username = user
35
Administrator Password
An assigned administrator password gives the user both read and write access to 'Fronius Datalogger Web.' The user can then open the 'Settings' menu and make any changes as desired. When assigning an administrator password, the user must enter the username and password in 'Fronius Datalogger Web' to open the 'Settings' menu. Username = admin
Make a direct connection to 'Fronius Datalogger Web' as per the 'Quick Installation' leaflet The 'Fronius Datalogger Web' website will appear (no request for passwords)
36
Time/Date
General The date and time handle several tasks in the system. The time and date are saved for every data record that is logged.
NOTE! You must set the time and date in order to operate 'Fronius Datalogger Web.' This is the only way in which Datalogger data can be recorded.
Time/Date
(1)
(2)
(3)
(5) (8)
(9)
(10)
(1)
(3)
(4) (6)
(8)
(7b)
(9)
(10)
37
(4) (5)
Date/Time setting option: synchronize to PC/laptop or manual Automatically adjust for daylight savings time
IMPORTANT For the automatic daylight savings time setting, the correct time zone must be selected. (6) (7) (7a) (7b) (8) (9) (10) Time from PC/laptop for PC synchronization setting Field for setting the time for the manual setting Date from PC/laptop for PC synchronization setting Calendar icon Calendar (opens when you click on the calendar icon) Field for setting the time zone 'Synchronization' button 'Cancel' button
38
Views
General Configuration of the Fronius Datalogger Web website takes place in the views. The language, yield and data for the Comparison and Total view can be set here. A sub-menu is available for settings related to inverters and Sensor Cards.
Views
(1) (2)
(3)
'General' view
You can enter the charge rate per kWh and the currency for calculating the yield in 'Yield' (1). The yield is shown in the Current total view. You can enter the CO2 savings per kWh and the unit for calculating the CO2 savings in CO2 factor (2). The CO2 savings are shown in the Current total view. The 'Fronius Datalogger Web' website will appear in the language set in the browser or in the last language selected. The language can be changed in the language selection fields (3).
39
Inverter views
1 2 3 4
Select an inverter to be displayed in the Comparison view Enter the respective solar module power for each inverter (the nominal output of the inverter is entered by default) Assign PV power to the respective inverter using the 'Accept' button Click on 'Save' The settings for the Comparison view are applied.
40
A specific channel name can be assigned to each sensor value of a Sensor Card in Sensor Cards (e.g., wind speed).
1 2 3
Select Sensor Card for which the channel names are to be changed Enter the desired channel names Click on 'Save'
41
Logging
General The Datalogger saves the realtime data of all inverters as well as all sensor cards and Fronius sensor boxes integrated into the system at regular intervals. The save interval can be defined in a range of 5 - 30 minutes. The data can be prepared, archived and viewed easily with a PC or laptop using the "Fronius Solar.access" software.
Logging
Memory capacity
The Datalogger has a memory capacity of up to 5 years and 7 months for a PV system with one inverter and a save interval of 15 minutes. However, the memory capacity is reduced accordingly depending on the number of inverters and/or Fronius sensor cards/boxes that are integrated into the system.
Determine logging points for inverters and Fronius sensor cards/boxes Logging duration [min] Save interval [min]
Logging duration [min] For inverter: e.g., 14 hours = 840 minutes For Fronius Sensor Card/Fronius Sensor Box: 24 hours = 1440 minutes
Calculate the total logging points Total logging points = = (number of inverters x logging points per day) + (number of Fronius Sensor Cards/ Boxes x logging points per day)
42
4 5
Round to whole numbers Determine memory capacity 2048 Memory sectors per day
Calculation example
2 inverters, logging duration = 14 hours (840 minutes) 1 Fronius Sensor Card, logging duration = 24 hours (1440 minutes) Save interval = 15 minutes 1. Logging points per day: Inverter logging points = 840 min 15 min 1440 min 15 min = 56
= 96
Total logging points = (2 x 56) + (1 x 96) = 208 (2 x 56) ... 2 inverters, (1 x 96) ... 1 Sensor Card 3. Memory sectors per day: Memory sectors = 208 114 = 1,825
4.
Rounded: 1,825 2
5.
Memory capacity [days]: Memory capacity = 2048 2 = 1024 days (= 2 years, 9 months, 18 days) 2048 Memory sectors per day
When the Datalogger memory is full, the oldest data will be overwritten by the newest data.
43
All log data saved to Datalogger Web is deleted using the Delete Data button. IMPORTANT The power supply to Datalogger Web must not be interrupted during the deletion process.
44
Network
General The 'Network' selection option is used to configure 'Fronius Datalogger Web' for integration with an existing network. For more information about network configuration for 'Fronius Datalogger Web,' please see the section 'Fronius Datalogger Web network configuration.'
Network
45
Network diagnostics
The Network diagnostics selection option under 'Network' is used to enter ping and trace route commands.
Ping command The ping command is used to determine whether or not a host is available and how much time a data transfer will take. Sending a Ping command:
1 2
Enter a host name in the Host field Click on the Ping button Ping command is sent The resulting data is displayed
Trace route command A trace route command is used to determine the intermediate stations the data takes to reach the host. Sending a trace route command:
1 2
Enter a host name in the Host field Click on the Trace route button Trace route command is sent The resulting data is displayed
46
Solar.web
General The 'Solar.web' selection option is used to make a direct connection to 'Fronius Solar.web' from 'Fronius Datalogger Web.' For more information about 'Fronius Solar.web,' please see the section 'Connecting to Fronius Datalogger Web via the Internet and Fronius Solar.web' or the 'Fronius Solar.web' online help.
Solar.web
(1) (4)
If the daily selection option is activated, you can select: The time of day when data is transmitted (1) Whether data is transmitted each day (2) Whether data is transmitted only on specific days (3)
If the hourly selection option is activated, you can select: The times of day when data is transmitted (4) Whether data is transmitted each day on the hour every hour (5)
47
Service messages
General Service messages as well as errors from inverters, the 'Fronius String Control,' etc. are sent to the Datalogger and saved. The 'Service messages' selection option is used to define how service messages are communicated. Communication can take place via: E-mail Fax SMS Relay contact Buzzer Service messages can be analyzed further using 'Fronius Solar.web' or 'Fronius Solar.access.'
Service messages
(1) (2) (3) (8) (15) (9) (4) (10) (11) (18) (5) (12) (19) (23) (6) (13) (20) (7) (14) (21)
(1)
PV system name Included in the service message text IMPORTANT The system name is used to identify the PV system that sent the message. Always enter a system name.
(2) (3)
Selection field for the language in which the service message should be sent Message to e-mail recipient Activate to send service messages to one or more e-mail addresses Field for up to a max. of 10 e-mail addresses Separate e-mail addresses with ';' Selection field to determine whether the service message will be sent immediately via e-mail or at a specific time Selection field for the time when a service message will be sent via e-mail
(4)
(5)
(6)
48
(7) (8)
'Send test e-mail' button Message to fax recipient Activate to send service messages to a fax number Field to enter country code Example: +43 = country code for Austria Field to enter the fax area code Field to enter the fax number Field for sending daily Selection field for the time when a service message will be sent via fax 'Send test fax' button Message to SMS recipient Activate to send service messages as an SMS to a telephone number Field to enter country code Example: +43 = country code for Austria Field to enter area code Field to enter the telephone number Field for sending daily Selection field for the time when a service message will be sent via SMS 'Send test SMS' button IMPORTANT Check your settings by sending a test message.
(9)
(16)
Save button 'Cancel' button Field to enter country code For a direct warning onsite. Along with the acoustical signal of the buzzer, additional warnings can also be triggered via the relay output (e.g., signal horn, warning light). The relay contact is an NCC (normally closed contact) and NOC (normally open contact) and is designed for the following max. voltage/current values: 42 V AC / 6 A 60 V DC / 400 mA 40 V DC / 1 A 30 V DC / 6 A The buzzer and relay are activated or deactivated using the Alarm switch on the Datalogger. An alarm is acknowledged by switching it briefly to 'Alarm off.' When 'Alarm on' is selected, the buzzer and relay are briefly activated as a test function.
49
(25)
'Run test' button Switches the relay and buzzer on for 1 second when the Alarm switch is set to 'Alarm on' Reset alarm button Resets a triggered alarm, switches off the relay and buzzer
(26)
50
System information
General The following system information for 'Fronius Datalogger Web' can be viewed in the 'System information' selection option: - Datalogger ID - PC board version - Software version - System time - Uptime - User agent - Gateway - DNS server - LED states - IP addresses - Subnet masks - MAC address
System information
192.168.1.1 192.168.1.1
192.168.1.180
(1)
(2)
(1) (2)
Datalogger restart button Used to restart Datalogger Web Reset to factory settings button with the following selection options: All settings except for the network Used to reset Datalogger Web to factory settings. Network settings remain unchanged. All settings Used to reset Datalogger Web and network settings to factory settings
IMPORTANT Using the Reset to factory settings button does not affect the time and date settings. When Datalogger Web is reset to factory settings, the time and date settings must be checked.
51
Firmware update
General You can update the Fronius Datalogger Web firmware from the Firmware update selection option. A firmware update can be carried out via LAN or web.
When the Automatic update search option (1) is activated, Datalogger Web will automatically search once a day for updates. If new updates are available, they will be shown in the grey display bar (2).
(1)
192
168
50
(2)
When the Automatic update search function is deactivated, there will be no automatic update search.
To search manually for updates, use the Check now button (3)
(3)
192
168
50
52
192
168
50
Procedure:
1 2 3
Use your Internet browser to open the 'Fronius Datalogger Web' website Open Settings / Firmware update Click on the 'Run update' button NOTE! The update process can take several minutes. The power supply to the Fronius Datalogger Web and the Internet connection should not be interrupted during this time. The web interface and the connection to 'Fronius Solar.access' or 'Fronius Solar.web' will not be available during the update process. The update is complete when the 'Supply LED' lights up green.
If the connection to the server should fail: deactivate the firewall for the duration of the update retry the update IMPORTANT If a proxy server is used to connect to the Internet: The Use proxy server for Web update selection option must be activated The required data must be entered
53
192
168
50
Procedure:
1 2
Download the current firmware from the Fronius homepage Run the downloaded update file on the PC/laptop This will start a web server from which 'Fronius Datalogger Web' will download the required files.
3 4 5 6
Use your Internet browser to open the 'Fronius Datalogger Web' website Open Settings / Firmware update Enter the IP address of the PC/laptop Click on the 'Run update' button NOTE! The update process can take several minutes. The power supply to the Fronius Datalogger Web and the Internet connection should not be interrupted during this time. The web interface and the connection to 'Fronius Solar.access' or 'Fronius Solar.web' will not be available during the update process.
The update is complete when the 'Supply LED' lights up green. If the connection to the server should fail: deactivate the firewall for the duration of the update retry the update
54
Technical data
Technical data Memory capacity Supply voltage Power consumption Degree of protection Dimensions Relay output* 16 MB 12 V DC typ. 1.43 W IP 20 190 x 114 x 53 mm 4.69 x 4.49 x 2.09 in. 42 V AC / 6 A 60 V DC / 400 mA, 40 V DC / 1 A, 30 V DC / 6 A 0.08 - 1.5 mm AWG 14 - 28 (USA/Canada) RJ 45, 100 Mbit via USB WLAN stick** RJ 45 12 V DC, max. 1 A, Class 2 0.13 - 1.5 mm AWG 16 - 24 (USA/Canada) 0 - 50 C 32 - 122 F
Maximum cable cross section for the relay output Ethernet (LAN) (WLAN) RS 485 (Solar Net) External power supply connection Cable cross section for external power supply connection Ambient temperature
* **
Values are only valid for pure ohmic load Available option
55
56
57
Fronius International GmbH 4600 Wels, Froniusplatz 1, Austria E-Mail: [email protected] http://www.fronius.com
Fronius USA LLC Solar Electronics Division 10421 Citation Drive, Suite 1100, Brighton, MI 48116 E-Mail: [email protected] http://www.fronius-usa.com
Under http://www.fronius.com/addresses you will find all addresses of our sales branches and partner firms!