T500 RTU Controller
T500 RTU Controller
PowerLogic T500
Catalog 2024
Substation Controller
se.com/powerlogict500
Notes
2 | PowerLogic™ T500
General Contents
PB125558
General Presentation 10
Commercial References 50
PowerLogic™ T500 | 3
We Have an Opportunity to Co-Create the
Future
More More
Electric Digitized
2X faster growth of electricity demand 20X more incremental connected devices
compared to energy demand by 2040 than connected people since 2020
More More
Decarbonized Decentralized
82% of the economic potential of energy 70% of new capacity additions will be in
efficency in buildings and more than half in renewables by 2040
industry, remains untapped
4 | PowerLogic™ T500
Power Industry is Facing Unprecedented
Changes
Increasing Complexity and Challenges Ahead
PowerLogic™ T500 | 5
Digitization Presents Tremendous
Opportunities to Enhance Grid Efficiency
Manage increasing complexity: integrate with specialized IEDs and systems
• Integrate devices from multiple vendors and protocols.
• Communicate simultaneously with several upstream systems.
• Advanced remote monitoring of system performance.
Improve cybersecurity: help defend against malicious software and unauthorized access
• Secure boot hardware and firmware signatures.
• Leverage embedded firewall.
• Apply RBAC policies as recommended by IEC 62351, IEC 62443, and IEEE 1686.
• Conduct telecontrol communications using TLS encrypted channels.
PB125559
PowerLogic™ T500
6 | PowerLogic™ T500
Next Generation Substation Controller
One single platform with a modular and flexible hardware, firmware, and
software for all your demands!
Highly scalable solution for demanding substation control applications
PB125560
• FW signatures, secure boot, and TLS encryption
Powerful
• Redundant and hot-swappable hardware
• Client/server for IEC 61850 and OPC-UA (2025)
• SCADA protocols: DNP3 and IEC101/4
• Legacy IED protocols: DNP3, IEC101/3/4 and Modbus
• Embedded logic engines: formulae and IEC61131
• Fully integrated with ESM and EPAS-E
Scalable
• Up to 100k datapoints
• 512 concurrent TCP connections
Easergy Builder
• Configuration/Engineering
• Multi-user environment
PB125561
PowerLogic™ T500 | 7
Next Generation Substation Controller
Predictive Maintenance
Connected to APM cloud services
Maintenance Tools
Cyber secure
Highly Reliable
Hot-swappable HW, enhanced mission profile
Sustainable
SE Eco design, RoHS, REACh, recyclable packaging
8 | PowerLogic™ T500
Integration of PowerLogic™ T500 with
EcoStruxureTM
24/7 connectivity
Real-time data everywhere Connect Collect Analyze Take action
anytime to make better-
informed decisions.
Apps,
Analytics &
Services
EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure
ADMS ArcFM Asset Advisor Microgrid Advisor Smart Metering Advisor Resource Advisor
Edge
Control
EcoStruxure EcoStruxure EcoStruxure
Substation Operation Microgrid Operation Advanced Metering Operation
PowerLogic T500
Connected RTU/Gateway
Products
RM6 & Easergy TH11 PowerLogic P5 PowerLogic
PowerLogic P7P7 IONION Power
Power Meter
Meter Minera SGrid Conext
Coneext SmartGen
Conext
Conex
onex
on
ne
nex
ext ttGe
G
SmartGen
Sma
Sm
SmartGe
ma e
rtGen
rtGGe
Ge PowerLogic T300
Transformer Remote Terminal Unit
PowerLogic™ T500 | 9
General Presentation
10 | PowerLogic™ T500
General Presentation
Applications 12
Applications 12
Product Overview 14
Modular Architecture 14
The Modules 15
Dimensions 21
Lifecycle Tools 25
PowerLogic™ T500 | 11
General Applications
Presentation
PowerLogic™ T500
DB446450
• Few bays
• Protection via IEDs HMI
• Optional HMI
I/O
• Flexible automation
Serial
• Centralized control Station T500 IEDs
Bus
Engineering
• Focused on data acquisition and integration I/O
• Requires general knowledge on substation automation IEDs
SCADA/DCS
• Many bays/stations
• Protection cord HMI
• Advanced HMI
• Fast automation T500
• IED local HMIs
Engineering
• Focused on tailored protection schemes
• Requires expert knowledge on specific technologies IEDs
Manned substations: Transmission, Large O&G
BCU BCU
I/O
12 | PowerLogic™ T500
General Applications
Presentation
PowerLogic™ T500
DB446452
Core Applications:
SCADA
• High range RTU’s high capacity + multifunctional gateway
• HV and MV network – IEC 61850 or legacy protocols (up to 200
protection relay devices)
LOCAL
• Legacy serial devices (brownfield market) SCADA
Upstream Interfaces:
• Local SCADA: IEC61850 or DNP3/IEC10x
• Regional SCADA: DNP3 or IEC101/4 (up to four redundant clients) HV Network
Advanced Features:
• Hot-swappable
Substation
• Redundancy CPU (HOT-STANDBY), PS, and Eth (HSR/PRP)
Time Synchronization:
• IEEE1588
MV Network Serial
Actual Market Trend
IEDs
• Cybersecurity IEC 62443-4-2 (target SL2)
• Align with engineering management and device management
• Web HMI integrated
IEDs
IEDs
PowerLogic™ T500 | 13
General Product Overview
Presentation
Modular Architecture
T500 configuration can have up to 96 I/O modules - regardless of backplane number. Backplanes can be expanded via
the dedicated connectors.
XS280 expansions can only be managed by an HU280 it they are installed in the same backplane.
I/O modules can be managed by an HU280 as long as they are available in the same bus - same backplane as HU280 or a
remote backplane connected via expansion ports.
14 | PowerLogic™ T500
General Product Overview
Presentation
The Modules
The PowerLogic™ PS280 module converts the input power into a regulated 5.4
Vdc output to power the electronic control components of the modules within the
backplane. Additionally, depending on ordering option, this module can provide an
auxiliary voltage for the polarization of the I/O interfaces of the acquisition modules.
The functional features of this block are:
PowerLogic™ T500 | 15
General Product Overview
Presentation
The Modules (cont.)
The PowerLogic™ XS280 communicates with the CPU module through the internal
bus, at a transmission rate of up to 1.5 Mbps. The multiplexing operation allows
transfers the message streams bidirectional from input channels and its signals.
The communication protocol between the PowerLogic™ XS280 and CPU module
follows a client-server (poll-response) structure, in which the client is the CPU
module, and the server are the different PowerLogic™ XS280 modules which are
installed.
Characteristics:
that can be configured as single, double or slow counter. These signals can be
associated to simple or double points in coreDb.
The main features of this module are:
• 32 configurable and high-precision digital input and distributed in two 16-signal
blocks.
• Each digital input can be configured as: Single/Double/Slow counter.
• Filtering the information before transmitting it to the CPU.
• Advanced processing of digital inputs, including the management of simple or
processed inputs with chronological register and time stamping.
• The parameter change memory time can be set for each signal.
• The module is synchronized via a message received from the CPU.
• 36 light indicators are available on the front side.
Characteristics:
• Number of inputs: 32
• Polarization voltage (PV): 12...125 Vdc (autodetect)
• Polarization range: From 80% PV to 120% PV
• Polarization blocks isolation (optocouplers): 2.5 kVrms
• Time-stamping resolution: 1 ms
• Connection to field: flat ribbon or terminals
• Typical consumption: 1 W (idle)
16 | PowerLogic™ T500
General Product Overview
Presentation
The Modules (cont.)
This module implements hot-swapping function, that is, it can remove and install on
the backplane while the RTU is working without affecting the proper functioning of
the system.
Characteristics:
• Number of outputs: 16
• Switching mechanism power voltage (PV): 24 Vdc
• Polarization range: 20% PV
• Isolation (optocouplers):
– Switching mechanism power block: 2.2 kVrms
– Between outputs and power: 2.2 kVrms
• Maximum nominal current per block: 8 A (4 latched outputs per block)
• Output switching capacity:
– 50 W, 250 Vrms; L/R ≤1 ms
• Typical consumption:
– Idle: 1.1 W
– Polarization: 16 mA/relay for 24 Vdc (regular)
PowerLogic™ T500 | 17
General Product Overview
Presentation
The Modules (cont.)
Characteristics:
• Number of outputs: 32
• Switching mechanism power voltage (PV): 24/48 Vdc - auto-range
• Polarization range: 20% PV
• Isolation (optocouplers):
– Switching mechanism power block: 2.5 kVrms
– Between outputs and power: 2.5 kVrms
• Max. current/output: 500 mA (non-simultaneous)
• Typical consumption:
– Idle: 1.1 W
– Switching mechanism (using TO180/Px): 0.8 W per active relay
– Switching mechanism (using TO180/H): 1.2 W per active relay
Characteristics:
18 | PowerLogic™ T500
General Product Overview
Presentation
The Modules (cont.)
Characteristics:
• Available slots:
– Four modules (EMS70140)
– Nine modules (EMS70190)
• Bus Expansion:
– High-speed RS-485 – 2x DB9
• Indications:
– Internal bus activity (TX & RX)
– Voltage supervision
PowerLogic™ T500 | 19
General Product Overview
Presentation
The Modules (cont.)
• Available Slots:
– Eight modules (EMS70280) – twin 4-slot buses
– Nine modules (EMS70290)
• Bus Expansion:
– High-speed RS-485 – 2x DB9
• Indications:
– Internal bus activity (TX and RX)
– Voltage supervision
PB125572
20 | PowerLogic™ T500
General Product Overview
Presentation
Dimensions
[in]
7.9
[0.31]
DB446455
270
[10.62]
203.8 26
[8.02] [1.02]
[in]
7.9
[0.31]
DB446456
270
[10.62]
430 26
[16.92] [1.02]
PowerLogic™ T500 | 21
General Product Overview
Presentation
Dimensions
mm
[in]
225.7 225.3
[8.88] [8.87]
DB446457
31.6
[1.24]
265.9
[10.46]
482.6 237
[19.15] [9.33]
mm
[in]
DB446458
265.9
[10.46]
482.6 237
[19] [9.33]
22 | PowerLogic™ T500
General Product Overview
Presentation
Dimensions
mm
[in]
45.6 186.34
[1.79] [7.33]
DB446459
244.98
[9.64]
mm
[in]
187.65
[7.38]
45
[1.77]
DB446460
244.9
[9.64]
PowerLogic™ T500 | 23
General Product Overview
Presentation
Installation and Update
Modules
Hot-swappable modules inserted in backplane slots
DB446461
Backplane
T500 internal bus
• Activity LEDs
Bus termination
4 types available:
• BP260/N4: 4-slot (wall-mount)
• BP260/N9: 9-slot (wall-mount
• BP270/N8: dual 4-slot (rack-mount)
• BP270/N9: 9-slot (rack-mount) HU280
T500 head unit
PS280
T500 power supply
3 options available:
• PS280/V2: 24 Vdc input
• PS280/V3: 48 Vdc input
• PS280/V4: 110...125 Vdc input
AI160
16x analog inputs
DO280
32x transistor outputs
AX160 DO180
8x AI + 4x AO 16x relay outputs
XS280 DI180
8x serial ports 32x digital inputs
24 | PowerLogic™ T500
General Product Overview
Presentation
Lifecycle Tools
PowerLogic™ T500 | 25
Functions and
Description
26 | PowerLogic™ T500
Functions and Description
General Description 29
Protocols and Communication Architecture 32
Cybersecurity 35
Characteristics 37
Standard Compliance 39
Configuration Tool 41
PowerLogic™ T500 | 27
PowerLogic™ HU280
Head Unit Communication
28 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
General Description
Easergy Builder
Local webserver
Substation IEDs
PowerLogic™ T500 | 29
Functions PowerLogic™ HU280
and Description
Head Unit Communication
General Description (cont.)
Physical Interface
PB125576
Reset button
PowerLogic Ring
Visual indication of device status
Watchdog
Watchdog output (health monitoring)
IRIG-B
IRIG-B synchronization input
2x RS-232/485 (RJ45)
Communication with serial comms.
MNT (ETH-RJ45)
Engineering, configuration and maintenance.
2x LAN/WAN (ETH-RJ45)
Communication with
upstream SCADA/DCS
PB125577
SD-card slot
Expand internal file storage
30 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
General Description (cont.)
2x RS-232/485 (RJ45)
Communication with serial comms.
All serial protocol client/servers can MNT (ETH-RJ45)
be associated to these ports.
Access embedded webserver.
Available to connect with
engineering tools.
2x LAN/WAN (ETH-RJ45)
Communication with upstream
SCADA/DCS.
4x LAN ports (Gbit-SF) All supported protocol servers can
LAN1 to LAN4 - these require insertion of be mapped to make use of these
SFP transceivers. ports.
To communicate using copper (RJ45) or
fiberoptic links. Configurable as standalone
links or redundant pairs (IEC 62439 PRP &
HSR supported). All supported protocols
can be associated to any of these. Also
supporting client and server for time
synchronization over NTP & IEEE 1588.
PowerLogic™ T500 | 31
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Protocols and Communication Architecture
• Communication channels can be PowerLogic HU280 can manage several communication channels and protocols
configured individually to fit application concurrently.
needs (DMS, local automation, etc.)
• Channels can be created and setup IEC 60870-5-101 controlling station and controlled station
using Easergy builder.
• UDP and Serial (RS232/485)
• Configuration settings – e.g., IP
addresses – can be modified using the • Supports secure authentication as per IEC 62351-5
embedded webApp. • Redundant connections with several controlling stations
• Embedded firewall can be configured
IEC 60870-5-103 client – manage legacy serial IEDs
to improve overall security.
• T500 is delivered with no default IEC 60870-5-104 controlling station and controlled station
protocols or channels preconfigured.
• TCP only
• Supports secure authentication as per IEC 62351-5
• Redundant connections with several controlling station IPs
Other protocols
32 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Protocols and Communication Architecture
Channels
PB125579
• AutoSwitch: used with secondary protocols. When the active channel stops
PB125580
Event
IED_Server
PB125582
Association of channels
PowerLogic™ T500 | 33
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Time Synchro and Sequence of Events
Time Synchronization
PB125583
Proper timestamping of events and alarms requires that correct time information is
provided to the PowerLogic™ T500. The PowerLogic™ T500 time synchronization
is managed by PowerLogic™ HU280. Time synchronization can be achieved in
numerous ways, depending on the overall system architecture and the required
precision.
• Time resolution: 1 ms
• Discrimination between two events: 1 ms
• Event storage capacity
– Up to 3000 events can be stored by PowerLogic™ T500
– The size of logs files is configurable
For all logs, when the storage capacity is reached, the most recent event clears the
oldest from the list.
34 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Cybersecurity
Port Hardening
All HU280 physical ports (LAN and WAN) not
used by the application are disabled on startup. Right
Additional firewall rules can be defined for each
WEB Services
configured port.
DATA BASE
FIRMWARE
SECURITY
BUILDER
TOOLS
RESET
At least one of the Ethernet ports of HU280 Role DATA
module must be enabled to give the possibility to
connect the unit.
VIEWER
OPERATOR
ENGINEER
INSTALLER
SECADM
Firewall
For each network interface (LAN and WAN), the User Assignment Permission Assignment
firewall can be configured :
DB446463
PowerLogic™ T500 | 35
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Cybersecurity
CAE tool
(CAE)
The EcoStruxure Cybersecurity CAE is a windows-based tool that allows a central
management of Security configuration and access to security logs of each
Security logs Security configuration PowerLogic™ T500.
Security configuration includes:
Security
logs • Security policy, including for example: password complexity or password
request strategy.
• Define rules for security logs, choose between various standards.
• Roles and permissions: Role Base Access Control (RBAC).
• Users with associated roles.
RADIUS server
Authentication
Radius and LDAP Server
result + role
RADIUS protocol This allows to use Unified Account management system shared across
Authentication Secured heterogenous solutions. The same credentials are used for each PowerLogic™
+ role request communication T500, at tools and at third party devices.
36 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Characteristics
Characteristics
Main
Range PowerLogic™
Product name PowerLogic HU280
Device short name HU280
Product or component type Communication gateway
Installation
PowerLogic™ T500 | 37
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Characteristics (cont.)
Characteristics (cont.)
Memory capacity 32 GB eMMC
4 GB RAM DDR4
Up to 64 GB slog for Secure Digital (SD) card
Validated SD cards Kingston Canvas Select Plus SD - SDS2/32 GB Class 10 UHS-I
Kingston Canvas Select Plus SD - SDS2/64 GB Class 10 UHS-I
IP Degree of protection IP20 conforming to IEC 60529
IK Degree of protection IK07 conforming to IEC 62235
Software
Communication port protocol IEC/BS 61850 client/server
DNP3 serial and TCP client/server
IEC/BS 60870-5-101 client/server
IEC/BS 60870-5-104 client/server
IEC/BS 60870-5-103 client
Modbus serial and TCP client/server
Cybersecurity Role-Based Access Control
TPM secure storage
Certificate management
Secure boot
Encryption engine
Firmware signature
Security log
Encryption algorithms AES (Advanced Encryption Standard)
3DES
MD5/SHA
RSA/ECC
Single-pass authentication encryption
Communication service TLS
DHCP client
Syslog Protocol
RADIUS client
LDAP client
Web server (HTTPS)
Data recording Event logs
Sequence of Events
Alarms
Time Synchronization protocols IRIG-B
GPS
PTP IEEE1588
SNTP
Functionality provided by web Device identification
applications Device status
Data monitoring and control
Events log
TCP/Serial traces
System log
Clock management
Firmware management
Configuration management
User management
Certificate management
Cybersecurity log
Customizable HMI screens including Single Line Diagram
38 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Characteristics and Standard Compliance
Characteristics (cont.)
Programming language ST (Structured text)
IL (Instruction list)
LD (Ladder)
FBD (Function block diagram)
SFC (Sequential function chart)
Calculation Formula
Packaging
Unit Type of Package PCE
Number of Units in Package 1 1
Package 1 Height 8.5 cm
Package 1 Width 23 cm
Package 1 Length 31 cm
Package 1 Weight 1.366 kg
Standard Compliance
Directive / Test Identification Details
CE Mark and UKCA Mark
2014/35/EU CE Mark Directive
Low Voltage Directive (LVD)
SI 2016 Nº 1101 UKCA Mark Directive
2014/30/EU CE Mark Directive
Electromagnetic Compatibility (EMC)
SI 2016 Nº 1091 UKCA Mark Directive
2011/65/EU CE Mark Directive
RoHS Regulations 2012 and SI 2012 UKCA Mark Directive
Nº 3032
WEEE 2012/19/UE CE and UKCA Mark Directive
EMC - Emission tests (Aligned with IEC/BS 61850-3 and IEC/BS 60255-26
PowerLogic™ T500 | 39
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Standard Compliance (cont.)
40 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Configuration Tool
DB446466
With the use of this Easergy Builder, the user is able to:
• Modify the configuration downloaded to Easergy Builder, in order to adapt/
add/modify new advanced functions or unit settings.
• Transfer the configuration file to the T500 unit once modified.
• Change functional settings directly on the unit from a PC connected to the
web server.
This tool is interactive and can be used to transfer the configuration file
from one to another.
Maintenance Tool
Easergy Builder
EcoStruxure™ Power Automation System Maintenance tool allows to track the
evolution of all the configuration and software artifacts throughout the lifecycle.
Device Management
• FW version
• HW version
• Serial number
Baseline Management
ESM • Backup configuration.
• Track evolution of changes with Time.
• Track versions of Baseline Vs Real.
Mass Firmware and Configuration Update
• Mass firmware upgrades.
• Mass configuration downloads.
• Mass incremental configuration updates.
Central Cyber Security Configuration (CAE embedded)
• Manage RBAC configurations.
• Backup all RBAC configurations and trace evolution.
Access to T500 Web Interface
• Identify devices and connect without needing to remember URLs.
PowerLogic™ T500 | 41
Functions PowerLogic™ HU280
and Description
Head Unit Communication
Configuration Tool (cont.)
Easergy Builder
DB446467
PC
SCADA Management Acquisition Module
Controller & Maintenance Profibus-DP
Easergy Builder is the advanced configuration tool of the PowerLogic™ T500 RTU,
Web Server reserved for the expert engineering team.
IEC 104 Controller
Controller Profibus DP The basic use of PowerLogic™ T500 does not require advanced modifications of
the PowerLogic™ T500 configuration.
The web server is sufficient for the user to personalize the system and change
SNTP,
GPS
Synchro-
nisation CoreDb IEC 101 / IEC 104
Controller
IEDs
basic settings.
DNP 3.0
Supervision
Controller
ISaGRAF
T500 PLC
IEDs
Interface
Easergy Builder: Relationship between coreDb and Easergy Builder permits the modification of an existing PowerLogic™ T500
other applications configuration from the main page WorkSpace.
This page includes the following general settings:
coreDb • IP parameters for LAN and WAN (IP address, delays, etc.)
DB446468
Configuration
Other files
BinControllers
The Workspace can manage several PowerLogic™ T500 RTU configurations. The
IEC 104
i4e Workspace page displays as a diagram the architecture of each PowerLogic™
T500 application (architecture of the different devices included in the
ModBus
BinControllers
Configuration Files
mdbe
Real Time Database
coreDb
Web Server
T500
configuration).
ISaGRAF
isg
Synchronization
Supervision
thm
Each of the following elements (named devices) can be associated with a
sup
setpoint
• Synchronization setting
To personalize the RTU application, Easergy Builder uses four main groups of
settings pages:
• Devices: one device for each function (protocol, modem port, SOE, ISaGRAF,
input/output)
• Channels: one channel for each internal or external communication link
• CoreDb: database including variables, labels and mapping of the application
• Synchronization: setting to synchronize the unit by SNTP server, GPS, or by the
protocol
42 | PowerLogic™ T500
Functions PowerLogic™ HU280
and Description
Head Unit Communication
User Interface
– Monitoring and control page: physical view of the system, data view
including display of status and analogs, control of commands and set
points.
– Diagnostic page: to consult and export.csv file (events log, cybersecurity
log, system log, protocol traces and disturbance records).
– Maintenance page: user settings, clock synchronization, IP configuration
settings, device status, firmware version update, configuration download.
– Settings page: These settings include the configuration of functional
parameters for communication, protocol, and detection, etc.
Diagnostic/Events
PowerLogic™ T500 | 43
Functions PowerLogic™ HU280
and Description
Head Unit Communication
User Interface (Cont.)
PowerLogic webApp
PowerLogic webApp is embedded web interface to the device enabling authorized users to:
• Monitor device configuration.
• View current state of all the processed.
• Check firmware versions.
Dedicated to the end user for the operation, commissioning, and maintenance, this tool allows (according to the cybersecurity access and
roles):
– Data consultation
– Events consultation
– Firmware updating
– Configuration saving/uploading
– Functional setting of T500
PB125592
PowerLogic webUI
The PowerLogic webUI is a lightweight web-based HMI built on webApp services, placing minimal load on CPU hardware. It offers 'just-
enough' features, including configuration in Easergy Builder, system view, single line diagram, alarm, and event management, and utilizes the
same RBAC model defined for controller CPU.
PB125593
44 | PowerLogic™ T500
Notes
PowerLogic™ T500 | 45
Schneider-Electric Service
46 | PowerLogic™ T500
Schneider Electric Service
Peace of Mind
Throughout your Installation Life Cycle 48
PowerLogic™ T500 | 47
Schneider Electric Service Peace of Mind Throughout
your Installation Life Cycle
Install
Life Cycle Services
Life Cycle Services Schneider Electric will help you to install efficient, reliable and secured solutions
based on your plans.
DB446469
Plan • Project management: Complete your projects on time and within budget
What are my options? • Commissioning: Ensure your actual performance matches the design, through
on-site testing and commissioning, and tools and procedures
Install
How do I install and commission? Operate
Schneider Electric helps you maximize your installation uptime and control your
capital expenditure through its service offer.
Operate
How do I operate and maintain? • Asset operation solutions: Provide the information you need to enhance
installation performance, and optimize asset maintenance and investment
• Advantage service plans: Customize service plans that cover preventive,
Optimize predictive and corrective maintenance
How do I optimize? • On-site maintenance services: Deliver extensive knowledge and experience
in electrical distribution maintenance
• Spare parts management: Ensure spare parts availability and an optimized
Renew maintenance budget of your spare parts
How do I renew my solution? • Technical training: Build the necessary skills and competencies to properly
and efficiently operate your installations
We offer to take full responsibility for the end of life processing of old electrical
CONTACT US! equipment.
https://www.se.com/ww/en/work/ • ECOFIT™: Keep up to date and improve the performance of your electrical
services/ installations (LV, MV, protection relays, etc.)
• MV product end of life: Recycle and recover outdated equipment with end of
life services
48 |
Notes
PowerLogic™ T500 | 49
Commercial References
50 | PowerLogic™ T500
Commercial References
Digital Configuration and Ordering Tools 52
PowerLogic™ T500 53
PowerLogic™ BP260 - Wall - Mount Backplane 53
Accessories 55
TOOLS 56
PowerLogic™ T500 | 51
Commercial references Digital Configuration and
Ordering Tools
https://www.se.com/ww/en/product-range/203452520-
PowerLogic™-t500
PB125595
52 | PowerLogic™ T500
Commercial references PowerLogic™ T500
EMS72000 PowerLogic T500 - HU280 T500 Hot-swappable Head Unit, 7xETH + 2xSerial
EMS71120 PowerLogic T500 - PS280/V2 T500 backplane power supply (In=24 Vdc. Aux.Out=24 Vdc)
EMS71130 PowerLogic T500 - PS280/V3 T500 backplane power supply (In=48 Vdc. Aux.Out=24 Vdc)
EMS71140 PowerLogic T500 - PS280/V4 T500 backplane power supply (In=110/125 Vdc. Aux.Out=24 Vdc)
EMS73100 PowerLogic T500 - XS280 T500 serial port expansion (8x RS232/485) RJ45
EMS74110 PowerLogic T500 - DI180/C1 T500 32x Digital inputs (12 - 125 Vdc autorange) (Terminals)
EMS74120 PowerLogic T500 - DI180/C2 T500 32x Digital inputs (12 - 125 Vdc autorange)
EMS74210 PowerLogic T500 - DO180/C1 T500 16x Relay outputs (powered with 24Vdc)(Terminals)
EMS74220 PowerLogic T500 - DO180/C2 T500 16x Relay outputs (powered with 24Vdc)
PowerLogic™ T500 | 53
Commercial references PowerLogic™ T500
EMS74310 PowerLogic T500 - DO280/C1 T500 32x Transistor outputs (24/48Vdc powered) (Terminals)
EMS74320 PowerLogic T500 - DO280/C2 T500 32x Transistor outputs (24/48Vdc powered)
EMS75410 PowerLogic T500 - AI160/C1 T500 16x Analog input module (Terminals)
EMS75420 PowerLogic T500 - AI160/C2 T500 16x Analog input module
EMS75510 PowerLogic T500 - AX160/C1 T500 combined analog module (8 inputs + 4 outputs) (Terms)
EMS75520 PowerLogic T500 - AX160/C2 T500 combined analog module (8 inputs + 4 outputs)
54 | PowerLogic™ T500
Ordering Accessories
REL70062 SFP ETH module RJ45 RJ45 SFP for LAN ports
REL70063 SFP ETH module multimode Multimode 100Mbps fibre SFP for LAN ports
REL70064 SFP ETH module single mode Single mode 100Mbps fibre SFP for LAN ports
EMS78100 PowerLogic T500 - TI180 T500 terminal block for DI180 (32x DI)
EMS78200 PowerLogic T500 - TO180/P0 T500 terminal block for DO180 (16x DO without relay)
EMS78320 PowerLogic T500 - TO180/P2 T500 terminal block for DO280 (with 16x relays at 24 Vdc)
EMS78330 PowerLogic T500 - TO180/P3 T500 terminal block for DO280 (with 16x relays at 48 Vdc)
EMS78340 PowerLogic T500 - TO180/H T500 heavy duty terminal block for DO280 (16x relays at 24 Vdc)
EMS78400 PowerLogic T500 - TA160 T500 terminal block for AI160 or AX160 (8x AI)
EMS78500 PowerLogic T500 - TS160 T500 terminal block for AX160 (4x AO)
EMS78600 PowerLogic T500 - CX160 T500 terminal block cable (unshielded) (2.5 m)
EMS78610 PowerLogic T500 - CX160/S T500 terminal block cable (shielded) (2.5 m)
EMS78910 PowerLogic T500 - CP020/C1 Unused T500 backplane connector dust cover (x2)
EMS78920 PowerLogic T500 - CP020/C2 Dust cover for unused DB9 connectors (2X)
EMS78930 PowerLogic T500 - CP020/C3 Dust cover for unused RJ45 connectors (2X)
EMS78940 PowerLogic T500 - CP020/C4 Dust cover for unused SFP connectors (2X)
| 55
TOOLS
www.se.com
This international web site allows you to access all the
Schneider Electric solutions and product information via:
• Comprehensive descriptions
• Range datasheets
• A download area
• Product selectors
56 | PowerLogic™ T500
TOOLS
Web Selector
Training
PowerLogic™ T500 | 57
www.se.com
November 2024 As standards, specifications and designs develop from time to time, please
PowerLogic™ T500 ask for confirmation of the information given in this document.
NRJED324204EN