Remote Access at Layer2

The document discusses the Secomea Layer2 agent, which enables remote access to devices using MAC addresses instead of IP addresses, overcoming the limitations of Layer2 communication confined to the same physical network. It highlights the importance of Layer2 access in the automation industry and provides examples of applications that benefit from this capability, such as Siemens' TIA portal and Schneider Electric's SoMachine. Additionally, the document addresses security and performance aspects of using the Layer2 agent, emphasizing its role in enhancing remote device management capabilities.

Uploaded by

lucas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views6 pages

Remote Access at Layer2

The document discusses the Secomea Layer2 agent, which enables remote access to devices using MAC addresses instead of IP addresses, overcoming the limitations of Layer2 communication confined to the same physical network. It highlights the importance of Layer2 access in the automation industry and provides examples of applications that benefit from this capability, such as Siemens' TIA portal and Schneider Electric's SoMachine. Additionally, the document addresses security and performance aspects of using the Layer2 agent, emphasizing its role in enhancing remote device management capabilities.

Uploaded by

lucas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

Remote access at Layer2


Using the Secomea Layer2 agent
Layer2 versus Layer3
An Ethernet connected device typically has two distinct addresses: an IP address such as 192.168.0.1, and a
MAC address such as 11:22:33:44:55:66. Normally, you can configure the device's IP address to your liking,
while the MAC address is a globally unique fixed address assigned to the device's Ethernet port by the
manufacturer.

In network terms, the IP address is a so-called Layer3 (logical) address, and the MAC address is a so-called
Layer2 (physical) address.

The layer numbers are defined in the OSI model, but we will not go further into that here, as you can easily
find more information about that on e.g. Wikipedia.

Let us instead focus on the differences between MAC/Layer2 and IP/Layer3 in the context of the
automation industry and remote device management.

Typically, a program (running on your PC) only needs to know the IP address of a device to connect to it.

However (as we will see later), many automation programs have a feature which enables them to discover -

Copyright Secomea A/S Page 1 of 6


Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

and communicate with - devices connected to the same Ethernet as the PC without knowing their IP
address. To do this, the PC and the devices communicate using their MAC addresses and using so-called
Layer2 broadcasts.

Using MAC addresses for communicating between the PC and the devices on Layer2 is by design confined
to the physical Ethernet where the devices are interconnected (typically through an Ethernet switch). This
is fine as long as the technician operating the PC is onsite with the device, but it becomes highly challenging
when you want to do utilize remote device management, since it conflicts with the very nature of Layer2
communication being "physically confined to the same Ethernet".

This is where Secomea's Layer2 agent comes into the picture; it seamlessly removes the barrier between
your PC and the remote physical Ethernet, and virtually plugs the PC into a switch port on the remote
Ethernet.

Layer2 agent configuration in the SiteManager:

Connection established to the Layer2 agent via LinkManager:

Copyright Secomea A/S Page 2 of 6


Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

Examples of Layer2 dependant application features


An example of a well known Secomea utility depending on Layer2 is the Secomea Appliance Launcher. This
utility is designed specifically for applying network and GateManager settings to Secomea appliances, such
as SiteManagers and TrustGates. Since such an appliance may not have IP address, or its IP address may not
match the IP network your PC is connected to, the only option is to reach it on the physical address (MAC).

If you connected with a LinkManager via a Connecting remotely to the same network using
traditional agent working at Layer3 to a remote the Layer2 agent would discover all devices in the
Device network with a number of Secomea remote network, and have them all becoming
appliances, and you started the Appliance fully accessible by the Appliance Launcher:
Launcher on your PC, you would get this result:

In reality no one would have a need for this specific scenario, as the Appliance Launcher utility is designed
for first time setup, which typically also means it is done by the same person that physically installs and
connects power to the appliance, and that person would therefore be on site and connected to the same
network.

Especially within the automation industry it is often seen that applications relies on Layer2 access to the
devices. This is not necessarily sign of bad protocol design, but could be because the design assumed that
the application user, such as the PLC programmer, would always be at the physical location in order to
verify that the machine is operating according to changes applied. In recent years, however, the abilities for
trouble shooting and debugging from within the application without needing physical access to the
automation devices has improved; concurrently with remote access becoming an standard part of an OEMs
maintenance offering.

Siemens for example, has evolved their Step7 PLC program into the Total Integrated Automation (TIA)
portal along with features of their PLCs and HMIs becoming more advanced. The device communication
protocol has, however, not changed as the TIA portal needs to stay backwards compatible, and the
communication protocol itself still does the job.

The Secomea solution has supported both Step7 and the TIA portal for many years. You just have to
specifically state in the Siemens program which IP address you want to access.

Copyright Secomea A/S Page 3 of 6


Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

But attempting to let the TIA portal scan for available devices after connecting with the LinkManager to the
standard Siemens agent, would result in this:

With the new Layer2 agent you will now experience that the TIA portal can scan and detect all Siemens
devices in the DEV network of the SiteManager:

Copyright Secomea A/S Page 4 of 6


Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

Another example is Schneider Electric’s SoMachine, which has similar functionality for discovering devices.
The standard Secomea agents already support remote access to Schneider equipment, but invoking the
discovery feature of SoMachine 4.1 via the standard agent would give this result:

The same action performed via the new Layer2 agent, will give this much richer result:

Bottom line is that with the Layer2 agent, the application and the devices sees each other as if they were
located in the very same physical network, connected to the same physical switch.

Copyright Secomea A/S Page 5 of 6


Whitepaper - Remote access at Layer2 – Using the Secomea Layer2 agent

Security aspects
Traditional IP access via the SiteManager agents typically involves limiting the access to a specific IP
address, and specific ports.

The Layer2 agent will by default provide the LinkManager access to the entire DEV network of the
SiteManager - and to any device in that network at both Layer2 and Layer3 level.

For IT security reasons this may not be desirable, and therefore the agent offers filtering on the IP address,
MAC address and even a combination of both:

If stating both the IP address and the MAC address, the security is in fact increased considerably. If the PLC
was incidentally replaced by another type device but with the same IP address, the SiteManager would
actively prevent access to it.

And if your intention is to have Layer2 access to multiple devices in the network, but want to limit the
access to specific users by the domain structures and account management in the GateManager Portal, you
simply create separate Layer2 agents for each device.

Performance aspects
Layer2 communication would typically represent a bigger overhead than Layer3 traffic, since also less
relevant broadcast messages could risk consuming bandwidth. The Layer2 agent will, however, actively
drop some types of packets that are deemed irrelevant for this purpose, such as STP and IGMP multicast.

From the LinkManager side, it would typically only be the Windows PC’s NetBIOS announcement messages
that would travel to the DEV net end. This is not blocked, as there may be a desire of the remote device to
identify the remote PC based on this, and also the amount of data related to this is limited.

More important is to prevent broadcasts from devices in the DEV network to flood the connection back to
the LinkManager PC. The best way to prevent this is to use the above mentioned filters, so broadcast
messages are limited to those that the device may send, and which may be relevant to the application.

It should also be noted that Layer2 traffic is encapsulated in TCP packets in order to ensure retransmission
and correct packet order of broadcast frames. This also means that Layer2 connections could suffer more
from high latency connections than ordinary IP based agents.

Final notes
It should be noted that the Layer2 agent does not solve all problems, and should only be used if needed.
The general recommendation is to use the standard vendor agents based on IP addresses.

The Layer2 feature is, however, an extremely important step to not only make the Secomea solution 100%
complete in aspect of supporting secure and complete access to any type of network device, but also to
effectively differentiate the Secomea solution from other remote access solutions.