Control Plan
Control Plan
B414-300-81-46-1-3831
B414-300-81-46-13832 TERRACE PLAN
B414-300-81-46-13833 ELEVATIONS
B414-300-81-46-13834 SECTIONS
N
izLrqr vkjs[k ,oa blesa fufgr fMt+kbu bathfu;LkZ bafM;k fyfeVsM dh LkaifRr gSA ;s ek= m/kkj fn, x, gSa vkSj m/kkjdrkZ us ;g Li"V Lke>kSrk fd;k gS fd u rks mUgsa iqu% eqfnzr fd;kk tk,xk] u udy dh tk,xh]
u m/kkj fn, tk,axs] u iznf'kZr fd, tk,axs vkSj u gh Lkhfer vkSj futh iz;ksx ds vykok budk dksbZ vU; iz;ksx gksxk vkSj ;g iz;ksx m/kkj nsus okys }kjk m/kkjdrkZ dks fyf[kr :i esa nh xbZ Lkgefr Lks gksxk A
NOTES -:
LINTEL
TYPE OPENING SIZE FRAME SIZE DESCRIPTION NOS.
LEVEL
230 BRICK A POWDER COATED ALUMINUM GLAZED PART. WITH
WORK (TYP)
E-3 ALP1 4000 x 2700 3980 x 2690 2700 SHUTTER & FAN LIGHT WITH 6.0mm THK.
TOUGHENED GLASS AS/ EIL STD. NO. 7-75-0015
01
750
W1 W1 W1 W1 FW FW W1 W1 W1 W1 A.R.L.
they will not be reproduced, copied, exhibited or used, except in the limited way permitted by a written consent given by the lender to the borrower for the intended use.
D 1225 775 775 775 375 375 775 775 775 1225 AL1 2000 x 2700 1980 x 2690 2700
POWDER COATED ALUMINUM GLAZED DOOR DOUBLE
SHUTTER WITH FAN LIGHT WITH 6.0mm THK. 05
1500
TOUGHENED GLASS AS/ EIL STD. NO. 7-75-0015
UPS ROOM (RETAIL) (RETAIL) (PIPELINE) (PIPELINE) (HEAVY DUTY FLOORING) AS/STRC.
AL3 1000 x 2100 0980 x 2090 2100
POWDER COATED ALUMINUM GLAZED DOOR SINGLE
SHUTTER WITHOUT FAN LIGHT WITH 6.0mm THK. 01
6025
VITRIFIED TILE FLOORING
RACK ROOM CONTROL ROOM CONTROL ROOM RACK ROOM
RAMP (1:7)
500
FF UD AC FC AC FC FF UD
AC FC
10000
- UD - UD FD1 2500 x 2700 2480 x 2690 2700 2 HRS FIRE RATED GLAZED FIRE DOOR DOUBLE 01
UD SHUTTER WITHOUT FANLIGHT
SD1
2 HRS FIRE RATED GLAZED FIRE DOOR DOUBLE
FD2 2000 x 2700 1980 x 2690 2700 SHUTTER WITHOUT FANLIGHT 05
EQ.
FP1 FP1 2700 2 HRS FIRE RATED STEEL DOOR DOUBLE SHUTTER
FD3 2400 x 2700 1980 x 2690 02
WITH VISION PANEL WITHOUT FANLIGHT
STORE
1700
V2 35 THK. COMMERCIAL FLUSH DOOR SINGLE SHUTTER
(HEAVY DUTY FLOORING) D1 1000 x 2100 980 x 2090 2100 FACED WITH 1mm THK. LAMINATION ON BOTH SIDE 03
1500
ALP1
19000
EQ.
FD2 FD2 FD2 FD2 FD2 35 THK. COMMERCIAL FLUSH DOOR SINGLE SHUTTER
SD1 D2 750 x 2100 730 x 2090 2100 FACED WITH 1mm THK. LAMINATION ON BOTH SIDE 03
C 1000 SUNSHADE
WITH PRESSED STEEL FRAME
PROJECTION
FD3 FD3 V 2000 x 750 1980 x 0730 2700 *DESIGN AS PER CLIENT ARCHITECT 01
CORRIDOR
2400
3000
E-4 1000 SUNSHADE AIR LOCK AL2 AL2 AIR LOCK LOBBY FC
PROJECTION (VITRIFIED TILE FLOORING)
LOBBY AC FC
UD E-2 POWDER COATED ALUMINUM GLAZED VENTILATOR
FIXED TYPE WITH 6.0 MM THK. TOUGHENED
V1 1000 x 0600 980 x 0730 2700 03
GLASS & 300 Ø EXHAUST FAN AS/EIL STD. NO.
AL3
B 1000 HIGH
100.950 JANITOR
7-75-0015
REMOVABLE
100.950 F.F.L. HANDICAPPED 100.950 01
2000
2325
AL1 AL1 AL1 AL1 ROOM V2 1500 x 0600 1480 x 0580 2700 SAME AS V1 WITHOUT EXHAUST FAN & LOUVERS
2200
TYPE RAILING AL1 1000 HIGH
SD1 TOILET F.F.L.
F.F.L. STORE/ D1 2600
REMOVABLE
TYPE RAILING
D1 01
DOCUMENT FC
V1 V4 2000 x 0750 2480 x 0730 2700 SAME AS V1 WITHOUT EXHAUST FAN & LOUVERS
1000
2430
TREAD-300 BATTERY ROOM ROOM LOBBY 1550 V1
LADIES STEPS :-
6000
RISER-6 EQ
(EPOXY COATING FL. WITH 2500 meeting room IN CHARGE ROOM OFFICE AREA D2
1390
FC PANTRY/ TREAD-300
13
(VITRIFIED TILE TOILET RISER-6 EQ W1 2000 x 1800 1980 x 1780 2700 *DESIGN AS PER CLIENT ARCHITECT
HIGH EPOXY COATING DADO)
UP FLOORING) (VITRIFIED TILE FLOORING) (VITRIFIED TILE FLOORING) (VITRIFIED TILE FLOORING) REST ROOM
2000 SINK WITH AC FC D1 1650
UP
AC FC AC FC
(VIT. TILE FLG.) 4800 x 3200 4780 x 3180 3500 2
EQ.
- FC UD FW
100.000
DRAIN BELOW UD UD
AC FC GENTS D2 100.000 *DESIGN AS PER CLIENT ARCHITECT
1200
-
4770
TOILET V1
A.R.L.
1000
UD 1800
A.R.L. EQ. EQ. EQ. EQ. EQ. EQ.
D2
EQ.
EQ. EQ. EQ. EQ.
300
600
W1 W1 W1 W1 W1
A N
300
FD1
450
300
EXHAUST 450 Ø FAN AT
750
V4 V
2500 HT. FROM FFL. 2200
2000
(TYP) 2300 4000 1200
1200
(TYP CHAJJA (TYP. CHAJJA
750 WIDE RCC GUTTER
MATERIAL AS/CLIENT OVER WINDOW) OVER VENTILATOR) MATERIAL AS/CLIENT
PROJECTION ABOVE
450 WIDE PROJECTION (BOTH SIDE)
RAMP
UP 1200 AT LINTEL LEVEL/CHAJJA
300 WIDE PROJECTION
6500
750
LEGEND :- AC = AIR CONDITIONED
8000 4000 6000 6000 6000 6000 4000 8000 ARL = TOP OF APPROACH AC FC FC = FALSE CEILING
48000 ROAD LEVEL UD FF UD = UNDER DECK
FFL = FINISHED FLOOR LEVEL FF = FALSE FLOORING
1' 1 2 3 4 5 6 7 8
A 5 24.10.24 REVISED AS/CLIENT'S COMMENTS & REISSUED FOR CONSTRUCTION
KG NB MKV
GROUND FLOOR PLAN 4 10.10.24 REVISED AS/CLIENT'S COMMENTS & REISSUED FOR CONSTRUCTION
KG MKV AK
3 17.09.24 REVISED AS/CLIENT'S COMMENTS & REISSUED FOR CONSTRUCTION
KG MKV AK
2 02.05.24 REISSUED FOR CONSTRUCTION KW NB MKV
02.05.24 REISSUED FOR CONSTRUCTION
E-1 1
0 01.05.24 ISSUED FOR CONSTRUCTION
KW
KW
MKV
MKV
AK
AK
B 13.07.23 ISSUED FOR ENGINEERING AS MKV RG
A 02.05.23 ISSUED FOR TENDER AS MKV RG