I2740 2.1en eDAQ Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 258

User Manual

English Deutsch Espanol


I
2
7
4
0
-
2
.
1

e
n
S
o
M
a
t

P
/
N

D
O
C

0
0
0
4
-
0
3
SoMat eDAQ
with TCE Software
SoMat eDAQ
2 I2740-2.1 en
I2740-2.1 en 3
SoMat eDAQ
Contents Page
Safety Information 15
1 Getting Started 19
1.1 Overview 19
1.1.1 eDAQ Layers 19
1.2 Equipment 19
1.2.1 Provided Equipment 20
1.2.2 Support Equipment 20
1.3 Setting Up the System 21
1.3.1 Installing SoMat Test Control Environment (TCE) 21
1.3.2 Getting Familiar with the eDAQ System 21
1.3.3 Setting Up the eDAQ 23
1.4 Test Process 23
2 Using the eDAQ 25
2.1 eDAQ Base System 25
2.1.1 Status LEDs 25
2.1.2 eDAQ Layers 26
2.1.3 Updating Firmware 29
2.2 Communications 30
2.2.1 Communications Methods 30
2.2.2 Changing the eDAQ IP Address and Host Name 31
2.3 Power Considerations 32
2.3.1 Input Power Voltage 32
2.3.2 Battery Power 33
2.3.3 Remote Power 34
2.3.4 Powering an eDAQ from a Vehicle 34
2.4 Data Storage 37
SoMat eDAQ
4 I2740-2.1 en
2.4.1 Data Formats 37
2.4.2 Data Storage Options 37
2.4.3 External PC Card 39
2.5 Networking eDAQ Systems 41
2.5.1 Hardwired Network 41
2.5.2 Wireless Network 42
3 Test Control Environment (TCE) 43
3.1 TCE User Interface 43
3.1.1 Setup Windows 43
3.1.2 Pull Down Menus 46
3.1.3 Toolbar 50
3.1.4 Status Bar 51
3.2 TCE Preferences 51
3.2.1 Communications 52
3.2.2 General 52
3.2.3 FCS Specific 54
3.2.4 Remote Test Run Control 57
3.2.5 Scope and Spectrum Display 58
3.2.6 Run-Time Display 59
3.2.7 Group DVM Display 59
3.2.8 Auto Range Options 60
4 Using TCE 63
4.1 Defining a Test 63
4.1.1 Adding a Network Node 63
4.1.2 Configuring the Hardware 64
4.1.3 Creating Channels and DataModes 65
4.1.4 Using Existing Setup Definitions 66
I2740-2.1 en 5
SoMat eDAQ
4.2 Calibrating Input Channels 67
4.2.1 Calibration Modes 67
4.2.2 Calibration Control 71
4.2.3 Calibration Specifications 72
4.2.4 AOM Calibration File 73
4.3 Running a Test 74
4.3.1 Initializing a Test 75
4.3.2 Prerun Options 75
4.3.3 Previewing a Test Run 76
4.3.4 Starting a Test Run 77
4.3.5 Using Interactive Triggers 77
4.3.6 Stopping a Test Run 77
4.3.7 Ending a Test 78
4.4 Monitoring Test Status 78
4.5 Viewing Channel Displays 79
4.5.1 Displays Overview 79
4.5.2 Common Display Options 81
4.5.3 DVM 82
4.5.4 Scope Plot 83
4.5.5 Spectrum Plot 84
4.5.6 Digital Readout 85
4.5.7 Bar Chart 86
4.5.8 Strip Chart 87
4.6 Uploading Test Data 88
4.6.1 Uploading SIE Data Files 88
4.6.2 Uploading SIF Data Files 88
4.6.3 Extracting Data from SIE or SIF Files 89
SoMat eDAQ
6 I2740-2.1 en
4.7 Using Remote Control Operation 91
4.8 Networking eDAQ Systems 92
4.8.1 Using Remote Control with a Network 93
5 eDAQ Hardware 95
5.1 ECPU (Base Processor) 95
5.1.1 ECPU Available Inputs and Outputs 95
5.1.2 ECPU Configuration Options 96
5.2 ECOM (Vehicle Network Communications Layer) 97
5.2.1 ECOM Available Inputs 98
5.2.2 ECOM Configuration Options 98
5.3 EDIO (Digital Input/Output Layer) 98
5.3.1 EDIO Available Inputs and Outputs 98
5.3.2 EDIO Configuration Options 100
5.4 EBRG (Bridge Layer) 102
5.5 EHLS (High Level Analog Layer) 103
5.6 ENTB (Non-Isolated Thermocouple Layer) 104
5.7 EITB (Isolated Thermocouple Layer) 106
5.8 EHLB (High Level Layer) 106
5.9 ELLB (Low Level Layer) 107
5.10 EGPS-5HZ (SoMat GPS Receiver) 108
5.10.1 Available Inputs 109
5.10.2 Configuration Options 109
5.11 EGPS-200 (Precision GPS Module) 109
5.11.1 Available Inputs 110
5.11.2 Configuration Options 110
5.12 Vehicle Bus Module 110
5.12.1 VBM Available Inputs 111
I2740-2.1 en 7
SoMat eDAQ
5.12.2 VBM Configuration Options 111
5.13 SMART Modules 112
5.14 Axis Network Camera Devices 113
5.14.1 Network Camera Available Inputs 113
5.14.2 Network Camera Configuration 113
5.14.3 Network Camera Troubleshooting 115
6 Input Channels 117
6.1 Common Input Channel Parameters 117
6.1.1 Desired Measurement 117
6.1.2 Output Sample Rate 118
6.1.3 Full-Scale Values 118
6.1.4 Output Data Type 118
6.1.5 Calibration Table 118
6.1.6 Prerun Rezero 119
6.1.7 Display Control 120
6.2 Digital Input Channels 120
6.2.1 Digital Input 120
6.2.2 Pulse Counter 121
6.3 Analog Input Channels 123
6.3.1 Bridge 123
6.3.2 Simultaneous High Level 126
6.3.3 High Level 128
6.3.4 Low Level 128
6.4 SMART Module Input Channels 131
6.4.1 SMSTRB4 (Strain SMART Module) 132
6.4.2 SMITC (Thermocouple SMART Module) 134
6.5 Temperature Input Channels 134
SoMat eDAQ
8 I2740-2.1 en
6.5.1 Thermocouple 134
6.5.2 Isolated Thermocouple 135
6.6 Bus-Oriented Input Channels 135
6.6.1 Common Bus Channel Parameters 136
6.6.2 Vehicle Bus Message Channel 137
6.7 Network Camera Input Channel 138
6.8 Simulation Input Channels 139
6.8.1 Simulation File 139
6.8.2 Simulation Function Generator 140
6.8.3 Simulation Message 141
7 Computed Channels 143
7.1 Common Computed Channel Parameters 143
7.2 Arithmetic Computed Channels 144
7.2.1 Desk Calculator 144
7.2.2 Engineering Scaler 147
7.2.3 Integer Scaler 147
7.2.4 Integrator 148
7.2.5 Pulse Counter 150
7.2.6 Directional Velocity 151
7.2.7 State Mapper 152
7.2.8 Statistical Analysis 153
7.2.9 Damage Equivalent Load 155
7.2.10 Fatigue Damage 156
7.3 Triggering Computed Channels 159
7.3.1 Interactive Trigger 160
7.3.2 Trigger Generator 160
7.3.3 Timed Trigger 161
I2740-2.1 en 9
SoMat eDAQ
7.3.4 Triggered Zero Suppression 162
7.3.5 Bitmap Trigger 163
7.3.6 Test Run Stopper 163
7.4 Time, Sample Rate and Filter Computed Channels 164
7.4.1 Time Channel 164
7.4.2 Time Base Shifter 165
7.4.3 Down Sampler 165
7.4.4 Up Sampler 166
7.4.5 Smoothing Filter 166
7.4.6 Digital Filter 167
7.5 Tracking Computed Channels 168
7.5.1 Max Track 168
7.5.2 Min Track 169
7.5.3 Range Track 169
7.5.4 Anomaly Detect 170
7.5.5 Valid Data Gate 171
8 DataModes 173
8.1 DataMode Memory Consumption 173
8.2 Common DataMode Parameters 173
8.3 Sequential DataModes 175
8.3.1 Time History 175
8.3.2 Burst History 176
8.3.3 Event Slice 179
8.3.4 Message Logger 180
8.3.5 Peak Valley 180
8.3.6 Peak Valley Slice 181
8.4 Histogram DataModes 182
SoMat eDAQ
10 I2740-2.1 en
8.4.1 Common Histogram Parameters 182
8.4.2 Peak Valley Matrix 183
8.4.3 Rainflow 183
8.4.4 Time at Level (One Dimensional) 184
8.4.5 Time at Level (Multidimensional) 184
8.5 Digital Output 185
9 eDAQ Web Interface 187
9.1 Main Page 187
9.2 System Tab 187
9.2.1 System Setup 188
9.2.2 System Status 189
9.2.3 System Maintenance 189
9.3 Hardware Tab 189
9.3.1 Hardware Table 190
9.3.2 Manage Network Cameras 191
9.3.3 Select Storage Device 192
9.4 Channels Tab 192
9.5 Test Tab 192
9.6 Data Tab 192
9.6.1 SIE Test Data 193
9.6.2 SIF Test Data 193
9.7 Custom Tab 193
9.8 Help Tab 194
10 Troubleshooting 195
10.1 Troubleshooting Procedure 195
10.2 Known Problems 196
10.3 eDAQ Flags 196
I2740-2.1 en 11
SoMat eDAQ
10.3.1 Status Flags 196
10.3.2 Error Flags 198
10.4 Corrupt SIF File Data Recovery 199
10.5 Tips on Eliminating eDAQ OverFlow Errors 200
11 Data Types 203
12 Cable Pinouts 207
12.1 ECPU (Main Processor) 207
12.1.1 Communications Cable 207
12.1.2 Power Cable 208
12.1.3 Digital I/O and Pulse Counter Cable 209
12.2 ECOM (Vehicle Communications Layer) 211
12.3 EHLS (High Level Analog Layer) 212
12.3.1 EHLS Transducer Cable 212
12.3.2 EHLS Analog Output Cable 212
12.4 EBRG (Bridge Layer) 213
12.4.1 EBRG Transducer Cable 213
12.4.2 EBRG Analog Output Cable 213
12.5 EDIO (Digital I/O Layer) 214
12.6 EHLB (High Level Layer) 215
12.6.1 EHLB Transducer Cable 215
12.6.2 EHLB Transducer Cable with Vehicle Bus 216
12.7 ELLB (Low Level Layer) 217
12.7.1 ELLB Transducer Cable 217
12.7.2 ELLB M8 Connector Option 218
12.8 Vehicle Bus Modules (VBM) 219
12.8.1 Transducer Cable for VPW Interface 219
12.8.2 Transducer Cable for J1708/LIN BUS Interface 220
SoMat eDAQ
12 I2740-2.1 en
12.8.3 Transducer Cable for CAN/SWC Interface 220
12.8.4 Transducer Cable for ISO9141/KW2000 Interface 221
13 Device Wiring 223
13.1 ECPU (Base Processor) 223
13.1.1 ECPU Digital Input 223
13.1.2 ECPU Digital Output 223
13.2 EDIO (Digital I/O Layer) 224
13.2.1 EDIO Digital Input 224
13.2.2 EDIO Digital Output 225
13.3 EHLS (High Level Analog Layer) 226
13.3.1 EHLS Analog Input 226
13.3.2 SMSTRB4 (Strain SMART Module) 227
13.4 EBRG (Bridge Layer) 228
13.4.1 EBRG Bridge Transducers 228
13.4.2 EBRG Analog Input 229
13.5 EHLB (High Level Layer) 230
13.6 ELLB (Low Level Layer) 231
13.6.1 ELLB Bridge Four-Wire Option 231
13.6.2 ELLB Bridge Six-Wire Option 232
13.6.3 ELLB Analog Input 236
14 Data Synchronization 237
14.1 Data Synchronization Characterization Method 237
14.2 Analog Channel Synchronization 237
14.2.1 EHLS and EBRG Channel Synchronization 238
14.2.2 ELLB Channel Synchronization 239
14.2.3 EHLB Channel Synchronization 239
14.3 Digital Channel Synchronization 240
I2740-2.1 en 13
SoMat eDAQ
14.4 Resampled Channel Synchronization 240
14.4.1 Bus-Oriented Channel Synchronization 240
14.4.2 Thermocouple Channel Synchronization 241
14.5 Analog Output Synchronization 241
14.6 Networked eDAQ System Synchronization 242
14.6.1 Hardwired Network Synchronization 242
14.6.2 Wireless Network Synchronization 242
15 Digital Filtering 243
15.1 Signal Aliasing 243
15.2 Digital Filter Characteristics 243
15.2.1 EHLS and EBRG Digital Filters 244
15.2.2 ELLB Digital Filters 248
16 Xth-Percentile Benchmark Tests 251
17 Data Processing Algorithms 253
17.1 Peak Valley Processing Algorithm 253
17.2 Rainflow Cycle Counting Algorithm 253
18 Cable Resistances 255
19 CE Compliance 257
19.1 eDAQ Hardware 257
19.2 Cables 257
SoMat eDAQ
14 I2740-2.1 en
I2740-2.1 en 15
SoMat eDAQ
Safety Information
Safety Rules
The supply connection, as well as the signal and sense leads, must be installed in
such a way that electromagnetic interference does not adversely affect device
functionality.
Automation equipment and devices must be covered over in such a way that adequate
protection or locking against unintentional actuation is provided (such as access
checks, password protection, etc.).
When devices are working in a network, these networks must be designed in such a
way that malfunctions in individual nodes can be detected and shut down.
Safety precautions must be taken both in terms of hardware and software, so that a
line break or other interruptions to signal transmission, such as via the bus interfaces,
do not cause undefined states or loss of data in the automation device.
Before connecting the device, make sure that the mains voltage and current type
specified on the type plate correspond to the mains voltage and current type at the site
of installation and that the current circuit used is sufficiently safe.
The maximum permissible supply voltage for the eDAQ is 55 V DC.
Appropriate use
The eDAQ and its connected transducers may be used for measurement tasks only
and directly related control tasks. To ensure safe operation, the transducer may only
be used as specified in the operating manual. It is also essential to follow the
respective legal and safety regulations for the application concerned during use. The
same applies to the use of accessories.
Each time, before starting up the equipment, you must first run a project planning and
risk analysis that takes into account all the safety aspects of automation technology.
This particularly concerns personal and machine protection.
Additional safety precautions must be taken in plants where malfunctions could cause
major damage, loss of data or even personal injury. In the event of a fault, these
precautions establish safe operating conditions.
This can be done, for example, by mechanical interlocking, error signaling, limit value
switches, etc.
General dangers of failing to follow the safety instructions
The eDAQ complies with the state of the art and is safe to operate. Inappropriate use
and operation by untrained personnel can give rise to remaining dangers.
Anyone responsible for installing, starting up, maintaining or repairing the equipment
needs to have read and understood the operating manual and in particular the safety
instructions.
Maintenance and cleaning
The eDAQ is maintenance free. Please note the following when cleaning the housing:
Before cleaning, disconnect the equipment from the power supply.
Clean the housing with a soft, slightly damp (not wet!) cloth. Never use solvents,
since these could damage the labelling on the front panel and the display.
When cleaning, ensure that no liquid gets into the equipment or connections.
SoMat eDAQ
16 I2740-2.1 en
Remaining dangers
The scope of supply and performance of the data acquisition system covers only a
small area of measurement technology. In addition, equipment planners, installers and
operators should plan, implement and respond to the safety engineering
considerations of measurement technology in such a way as to minimize remaining
dangers. Prevailing regulations must be complied with at all times. There must be
reference to the remaining dangers connected with measurement technology. After
making settings and carrying out activities that are password-protected, you must
make sure that any controls that may be connected remain in safe condition until the
switching performance of the amplifier system has been tested.

In this manual, the following symbols are used to point out remaining dangers:

DANGER
Meaning: Maximum danger level
Warns of an imminently dangerous situation in which failure to comply with safety
requirements will result in death or serious bodily injury.
WARNING
Meaning: Dangerous situation
Warns of a potentially dangerous situation in which failure to comply with safety
requirements can result in death or serious bodily injury.
CAUTION
Meaning: Potentially dangerous situation
Warns of a potentially dangerous situation in which failure to comply with safety
requirements could result in death or serious bodily injury.
Meaning: Electrostatic sensitive devices
Devices marked with this symbol can be destroyed by electrostatic discharge. Please
observe the precautions for handling electrostatic sensitive devices.
Symbols pointing out notes on use and waste disposal as well as useful information:

NOTE
Points out that important information about the product or its handling is being given.
Meaning: CE mark
The CE mark enables the manufacture to guarantee that the product complies with the
requirements of the relevant CE directives (the declaration of conformity is available at
http://www.hbm.com/HBMdoc).

Meaning: Statutory marking requirements for waste disposal
National and local regulations regarding the protection of the environment and
recycling of raw materials require old equipment to be separated from regular
domestic waste for disposal.
I2740-2.1 en 17
SoMat eDAQ
For more detailed information on disposal, please contact local authorities or the
dealer from whom you purchased the product.
Working safely
Error messages may only be acknowledged if the cause for the error has been
removed and no further danger exists.
Conversions and modifications
HBMs express consent is required for modifications affecting the SoMat eDAQ design
and safety. HBM does not take responsibility for damage resulting from unauthorized
modifications.
In particular, any repair or soldering work on motherboards is prohibited. When
exchanging complete assemblies, it is essential to use original HBM parts only.
The product is delivered from the factory with a fixed hardware and software
configuration. Changes can only be made within the possibilities documented in the
manuals.
Qualified personnel
The equipment may be used by qualified personnel only; the specifications and the
special safety regulations need to be followed in all cases.
This means people who meet at least one of the three following requirements:
Knowledge of the safety concepts of automation technology is a requirement
and as project personnel, you must be familiar with these concepts.
As automation plant operating personnel, you have been instructed how to
handle the machinery and are familiar with the operation of the equipment and
technologies described in this documentation.
As commissioning engineers or service engineers, you have successfully
completed the training to qualify you to repair the automation systems. You are
also authorized to activate, to ground and label circuits and equipment in
accordance with safety engineering standards.
It is also essential to comply with the appropriate legal and safety regulations for the
application concerned during use. The same applies to the use of accessories.
The term qualified personnel refers to staff familiar with the installation, fitting,
start-up and operation of the product, and trained according to their job.
SoMat eDAQ
18 I2740-2.1 en
I2740-2.1 en 19
SoMat eDAQ
1 Getting Started
1.1 Overview
The SoMat eDAQ is a sealed, stand-alone, microprocessor-based data acquisition
system designed for portable data collection in the harshest of environments. It has
leading-edge signal conditioning and a capacity to perform a broad range of on-board
data processing. Engineered to be rugged and mobile, the eDAQ is tested to military
standards at 10 gs from 55 to 2000 Hz. Internal back-up batteries protect the eDAQ
from unplanned power losses or low voltage events. Hundreds of synchronous
channels are possible in a single system with virtually limitless channel counts when
networking multiple systems using Ethernet communications.
1.1.1 eDAQ Layers
The eDAQ consists of one base processor layer and a number of optional add-on
layers. The following table lists the available layers, including the base processor.
1.2 Equipment
This section describes the provided equipment and the support equipment necessary
to set up the eDAQ system and run a test.
Name Order Number Description
ECPU 1-ECPU-PLUS-2 eDAQ Base Processor with Extended Voltage
1-ECPU-PLUS-COM-2 eDAQ Base Processor with integrated ECOM
layer
ECOM 1-ECOM-2 eDAQ Vehicle Network Communications Layer
EHLS 1-EHLS-B-2 eDAQ High Level Analog Layer
1-EHLS-AO-2 eDAQ High Level Analog Layer with Analog Out
EBRG 1-EBRG-350-B-2 eDAQ Bridge Layer; 350-Ohm
1-EBRG-350-AO-2 eDAQ Bridge Layer; 350-Ohm with Analog Out
1-EBRG-120-B-2 eDAQ Bridge Layer; 120-Ohm
1-EBRG-120-AO-2 eDAQ Bridge Layer; 120-Ohm with Analog Out
EDIO 1-EDIO-B-2 eDAQ Digital I/O Layer
1-EDIO-5HZGPS-2 eDAQ Digital I/O Layer with SoMat GPS
ENTB 1-ENTB-2 eDAQ Non-Isolated Thermocouple Layer
EITB 1-EITB-K-2 eDAQ Isolated Thermocouple Layer ; K-type
1-EITB-J-2 eDAQ Isolated Thermocouple Layer; J-type
1-EITB-T-2 eDAQ Isolated Thermocouple Layer; T-type
1-EITB-E-2 eDAQ Isolated Thermocouple Layer ; E-type
ELLB N/A eDAQ Low Level Layer (no longer in production)
EHLB N/A eDAQ High Level Layer (no longer in production)
SoMat eDAQ
20 I2740-2.1 en
1.2.1 Provided Equipment
The initial shipment of a basic eDAQ contains the hardware listed below; additional
hardware may be included based on options ordered. The eDAQ also comes with
SoMat Test Control Environment (TCE) software.
NOTE
If any items do not arrive as expected, contact your system supplier, nearest HBM
sales representative or HBM immediately.

1.2.2 Support Equipment
In addition to the eDAQ base processor, add-on layers and included cables, set up of
the eDAQ system requires an adequate power supply, a support PC and any
transducers or sensors needed for testing.
Power Supply
The eDAQ is designed to always be connected to an adequate power supply for the
duration of all test runs. An example of an adequate power supply is a charged
nominal 12-volt vehicle battery system that reliably supplies around 13.5 volts.
Additionally, an optional SoMat AC Power Supply (1-E-AC-2 or 1-E-AC/18-2) is
available.
For more information on eDAQ power, see Power Considerations on page 32.
Support PC
A support PC is necessary to run TCE. The PC must meet these minimum
requirements for TCE to operate correctly.
Microsoft Windows XP/7 (Windows 7 requires TCE 3.15 or later)
40 MB of available hard disk space
CD-ROM drive or Internet access (required for updating and installing software)
16 MB of RAM (32 MB recommended)
Mouse or other pointing device
An Ethernet card
Item (Order No.) Description
SoMat eDAQ SoMat eDAQ base layer and any optional layers.
SoMat Digital I/O Transducer
Cable (1-SAC-EDIGIO-2)
44-pin HDD-Sub male plug with two connector cables ending
in pigtails.
SoMat Communications
Cable
(1-SAC-ESR9/XO-2 or
1-SAC-ESR9/HUB-2)
26-pin HDD-Sub male plug with two connector cables, one
labeled E-ETHERNET which ends in an RJ-45 connector
and the other labeled RS232 which ends in a 9-pin D-Sub
female plug. The XO cable is used for connection directly to
the host computer, while the optional HUB cable is used for
network operation.
SoMat Power Cable
(1-SAC-EPWR15-2)
15-pin D-Sub female plug with two connector cables ending in
pigtails.
SoMat TCE Installation CD CD containing the installation files for TCE.
I2740-2.1 en 21
SoMat eDAQ
Sensors
The eDAQ supports a wide variety of sensors for data acquisition, including several
offered directly by HBM. Contact your sales representative or visit
www.hbm.com/somat for more information.
1.3 Setting Up the System
Setting up the eDAQ data acquisition system involves installing TCE on the support
PC and setting up the eDAQ hardware.
1.3.1 Installing SoMat Test Control Environment (TCE)
To install TCE:
1. Run the TCE installer found on the TCE/eDAQ distribution CD or downloaded from
the www.hbm.com/somat. Follow the instructions on screen.
2. When prompted, enter the desired destination folder for the installation. By default,
the TCE installation program places each new software release in a unique folder.
3. If updating to a new version of TCE, copy or move the file TceMS.ini from the
working directory of the previous TCE installation folder to the working directory of
the new TCE installation folder. This process transfers the current TCE preference
settings into the new version of TCE.
Notes on the Installation and Working Directories
Using a Common Installation Folder: Previous versions of the TCE installer used a common destination folder for all
releases. To continue using a common folder, uninstall the previous TCE version before starting the new installation.
Change the installation program default folder name to the common folder name (previously, C:\Program
Files\SoMat\Tce_eDAQ) during the installation process. To keep TCE preference settings, be sure to save the
TceMS.ini file before uninstalling the previous version of TCE.
Default Working Directory: Effective starting with TCE 3.15, the TCE working directory defaults to a subfolder under the
My Documents directory in SoMat\TCEvX.XX.XX build XXX. This working directory includes all database files and
the TCE preferences files. New user database files must be add to this working directory.
Modifying the Working Directory: To change the working directory, open the TCE application shortcut properties by right
clicking the application shurtcut or the entry in the Windows Start menu and select Properties. In the Target field, delete
the second string, which starts with -d, leaving only C:\Program Files\SoMat\TCE vX.XX.X build
XXX\TceMs.exe. Then type the desired working directory in the Start In field. Note that the folder must already exist.
For Windows XP or earlier, the Start In folder can reside in Program Files. Select Apply to save the new settings.

1.3.2 Getting Familiar with the eDAQ System
eDAQ Front Panel
The ECPU front panel contains the power switch and status LEDs needed for eDAQ
operation as well as the access door to the PC Card slot. The configuration of the front
panel is shown in the following diagram.
SoMat eDAQ
22 I2740-2.1 en
Figure 1-1: Diagram of the eDAQ front panel.
eDAQ Back Panel
The power and communications connectors needed to set up the eDAQ are on the
ECPU back panel. The configuration of the back panel is shown in the following
diagrams.
Figure 1-2: Diagram of the eDAQ back panel.
SoMat Communications Cables
The eDAQ is compatible with several different communications cables. Each cable has
a 26-pin D-Sub for connection to the eDAQ Comm port. The cables may also have an
Ethernet X/O connector for direct communication from the eDAQ to the PC, an
Ethernet HUB connector for communication through an Ethernet hub, a 9-pin serial
connector for communications through a PC serial port or a set of two LEMO sync
connectors for networking eDAQ/eDAQlite systems. A summary of the available
communication cables is below.
Power Switch Status LEDs PC Card Slot Door
Comm. 1 Power Digital /O
26-Pin D-Sub
Communications
Connector
15-Pin D-Sub
Power Connector
HSS Connector
for eDSPLAY
Communications Cable
Ethernet
(X/O)
Ethernet
(HUB) Serial Sync
1-E-ETHERNET X/O-2 X
1-E-ETHERNET HUB-2 X
1-SAC-ESR9/XO-2 X X
1-SAC-ESR9/HUB-2 X X
1-SAC-ESYNCADAPT-2 X X
1-SAC-ESYNCADAPT-SC-2 X X X
I2740-2.1 en 23
SoMat eDAQ
1.3.3 Setting Up the eDAQ
To power the eDAQ and establish communications with its support PC:
1. Connect the 26-pin D-Sub connector of a SoMat Communications Cable to the
Comm connector on the eDAQ. For Ethernet communication, connect the RJ-45
connector either directly to the PC or to an Ethernet hub, depending on the
communications table. For serial communication, connect the 9-pin D-Sub
connector directly to the PC. The serial connection may be removed once the setup
process is complete, but it may be helpful in network setup should difficulties arise
with Ethernet communication.
2. Connect the appropriate cable(s) to the eDAQ for the desired type of transducers
or sensors.
3. Make sure the power supply for the eDAQ is turned off and connect the SoMat
Power Cable (1-SAC-EPWR15-2) between the eDAQ Power connector and the
power supply. Use the red and black pigtails on the cable labeled POWER for the
main power connection: black to the negative or ground terminal and red to the
positive terminal. The remote cable, labeled REMOTE POWER, is for remote
control of the eDAQ. To use remote power, connect a single-pole, single-throw
switch to the pigtails. If not using remote power, make sure the pigtail wires are well
insulated as shorting the two wires together turns the eDAQ off. For more
information on remote power usage see Remote Power on page 34.
4. Turn on the power supply. If the status LEDs do not light, press the power switch on
the front panel to apply power to the eDAQ.
1.4 Test Process
There are several phases to conducting a test using the eDAQ as outlined below. For
more information on using TCE to complete these phases, see Using TCE on
page 63.
Plan Test
Before any test setup, first develop a test plan including the test objective, the physical
quantities to be measured, any signal manipulation or computations to perform during
the test, the desired data collection method and when and how often data should be
recorded.
Prepare Hardware
After planning the test, install the various gages, sensors and cables required for the
test. This includes attaching the transducers to the components being measured,
connecting the transducer cables to the transducer and connecting the transducer
cables to the appropriate eDAQ connectors.
Define Test
The eDAQ collects data from transducers and other input sources, manipulates the
signals using computed channels and stores the data in a variety of DataModes.
Use the TCE software that comes with the eDAQ to fully define the desired test. Also
during this phase, verify that the transducers and data channels are operating as
expected using TCE channel display options.
SoMat eDAQ
24 I2740-2.1 en
Run Test
Running the test consists of several necessary steps including initializing the eDAQ,
starting the test run, collecting the data, stopping the test run and ending the test
session. After a test is initialized, the eDAQ allows for multiple test runs during a single
test session. Use TCE or the integrated web interface to perform these tasks as well
as more advanced test run options.
Upload, Display and Analyze Test Data
Use TCE or the web interface to upload the acquired test data. The web interface also
offers simple data displays. For more advanced data display and analysis, use SoMat
InField. For more information on InField, refer to the InField Users Manual.
I2740-2.1 en 25
SoMat eDAQ
2 Using the eDAQ
The following chapter describes the setup and operation of the eDAQ including the
LED status indicators, updating firmware, eDAQ communications, power
considerations, data storage and eDAQ networking.
2.1 eDAQ Base System
2.1.1 Status LEDs
There are three LEDs (green, yellow and red) located on the eDAQ front panel that are
important indicators of eDAQ status.
Initial State
When powering on, all three LEDs turn on indicating that the main processor is starting
the boot up process. However, the eDAQ displays different LED states than this on
abnormal conditions as defined by the following table.
NOTE
If all three LEDs stay on for more than about 10 seconds, the boot has failed at a very
early stage or the boot was interrupted in the serial loader (which should not happen
accidentally).

Possible States
After all three LEDs are on, the main processor boot up begins. The LED states that
can exist after the boot up starts are defined as follows.
3
Status LEDs
Red Yellow Green Description
4 Hz Off Off Bus pins misaligned.
4 Hz 4 Hz Off Blown fuse.
On On Off Power supply failure or voltages not stabilized.
On On On No problems detected, boot up starting.
Red Yellow Green Description
On On On Normal for early in boot up process.
Off On On Normal for later in boot up process.
Off Off On Ready, no test initialized, no error/status flag.
On Off On Ready, no test initialized, error/status flag.
Off 0.5 Hz On Ready, test initialized, no error/status flag.
On 0.5 Hz On Ready, test initialized, error/status flag.
Off 1 Hz 1 Hz Ready, waiting for sync, no error/status flag.
On 1 Hz 1 Hz Ready, waiting for sync, error/status flag.
Off 8 Hz On Ready, test running, no error/status flag.
On 8 Hz On Ready, test running, error/status flag.
SoMat eDAQ
26 I2740-2.1 en
For more information on error and status flags, see eDAQ Flags on page 196.
2.1.2 eDAQ Layers
Adding a Layer
CAUTION
Read through this section in its entirety prior to performing any steps. If any portion of
the installation process is not clear or is not comfortable to perform, ship the eDAQ to
HBM customer service for the installation. If done improperly, the addition of new
layers can cause damage to the eDAQ stack and any damage is the sole responsibility
of the customer.

Adding a layer requires an eDAQ stack, the desired new layer, a #1 Phillips head
screwdriver and a 2.5-mm hex driver.
To add a layer to an eDAQ stack:
1. Power down the eDAQ and disconnect the power supply.
2. Remove the eDAQ top plate by removing the eight screws securing it to the stack.
3. To remove layer to reach a specific location within the stack, remove the six hex
screws on the side rails of the layer and then remove the layer. Repeat as
necessary to access the desired position within the stack.
4. Install the J2 and J3 connectors onto the bus pins of the previous layer. Use the
third row of the J3 connector as a spacer between the rows of bus pins
5. Set the layer address using the jumpers. For more information on eDAQ layer
addresses, see Layer Addressing on page 27.
6. Remove the four Phillips-head screws from the back panel of the new layer.
Remove the back panel to provide a clear view for aligning the bus pins. Be careful
not to damage or tear the gasket.
7. Loosen the seven screws securing the inner board to the outer ring to allow the
inner board to shift within its frame during installation.
8. Align the bus pins of the new layer with the pins of the layer below. The pins must
be aligned correctly. Improper alignment damages the layer on power-up.
9. Press the layer onto the eDAQ stack. Use care not to put undue strain on the layer.
Repeat for each layer as necessary until all layers are attached.
10.Replace the back panel and start the four securing Phillips-head screws.
11.Start the six hex screws along the top of the ring. Make sure to start all the screws
and then tighten the four back panel screws and the six ring screws. The gasket
should compress and the metal enclosures should be very close if not touching.
12.Tighten the seven screws to secure the inner board to the outer ring.
13.Repeat steps 6-12 for each additional layer until the complete stack is assembled.
2 Hz On On Updating firmware - do not power down.
4 Hz 4 Hz 4 Hz Power microprocessor not communicating with main
processor.
On On 2 Hz Powering down.
Off Off Off Powered down.
Red Yellow Green Description
I2740-2.1 en 27
SoMat eDAQ
14.Place the top plate on the stack and secure it using the eight securing screws. Be
careful not to scratch the top.
15.Reconnect the eDAQ to the power supply.
Layer Addressing
The eDAQ stack is configured at the factory with the layer address jumpers properly
set. Follow the guidelines below to reconfigure an eDAQ stack.
On all eDAQ layers except the ECPU, there is a set of three jumper locations used to
assign a physical layer address. Each jumper location consists of two associated pins
labeled 1-2, 3-4 or 5-6 where pins 1-2 represent the least significant digit and pins 5-6
represent the most significant in a three-digit binary number. A jumpered pair results
in a logical 0. An illustration of all possible logical addresses follows.
Figure 2-1: Possible jumper configurations for addressing eDAQ layers.
All layer address jumper sets are on the side of the bus connector receptacle (i.e.,
opposite the side with the bus connector bare pins). The jumper is labeled JP1 on all
layers except the EHLB where the jumper is labeled JP2.
6
5 1
2
3
4
6
5 1
2
3
4 6
5 1 3
4
6
5 1 3
4
6
5 1
2
3
4
6
5 1
2
3
4 6
5
2
3
4
6
5
2
3
4
0 - 1 -
4 - 5 - 7 -
3 -
6 -
2 -
1
1
2
2
SoMat eDAQ
28 I2740-2.1 en
Checking Current Layer Addresses
To check the current layer addresses, use TCE to upload the eDAQ log. Select Upload FCS Log from the FCS Diagnostics
sub-menu of the FCS Setup menu. Choose to view the file in Microsoft Notepad and then scroll to the end of the log file
where there is a list of the installed hardware and their jumper address. An example list is below.
<** LogBook End **>
Slot Jumpers : ID Version Serial
00 mpb0 : MPB v3.14 MSMPB.13-1632
01 mpb0 : MPBSer MSMPB.13-1632
02 mpb0 : Power v2.2 MSMPB.13-1632
03 exp1 : Brg_1 v1.2 MSBRG.02-0702
04 exp2 : Brg_2 v1.2 MSBRG.02-1235
05 exp4 : DIO_1 v1.7 MSDIO.02-1097
06 exp4 : GPS_1 v1.7 MSDIO.02-1097
07 exp6 : HLSS_1 v1.1 MSHLS.03-2378

Valid Layer Addresses
There are two general types of layers for the eDAQ: type I layers, previously referred
to as legacy boards, and type II layers, previously referred to as expansion boards. The
table below defines the type of all available layers.
From the factory, the ECPU layer is hardwired with the address 0 and is always
positioned at the bottom of the stack. The stack can include any combination of
additional add-on layers stacked on top of the ECPU layer. The following rules apply
when addressing add-on layers in the same eDAQ stack.
A type I and type II layer may share a layer address.
A type I layer address must be unique among other type I layers.
A type II layer address must be unique among other type II layers.
A type I layer cannot have the address of 6 when type II layers are present.
A type I layer cannot have the address of 7 under any configuration.
Type I Layers Type II Layers
ECPU (Base Processor) EDIO (Digital I/O Layer)
EHLB (High Level Layer) ECOM (Vehicle Network Communications Layer)
ELLB (Low Level Layer) EHLS (High Level Analog Layer)
EBRG (Bridge Layer)
ENTB (Thermocouple Layer)
EITB (Isolated Thermocouple Layer)
I2740-2.1 en 29
SoMat eDAQ
Taking these rules into account, an eDAQ stack configuration with all type I layers may
have a maximum of five add-on layers and any other configuration may have a
maximum of four type I layers and eight type II layers not accounting for power and
temperature limitations.
NOTE
For eDAQ stacks with more than one EDIO layer, any EDIO layer with a GPS module
must have a lower layer address than all EDIO layers without a GPS module. This rule
also applies to stacks with more than one ECOM layer.

Stacking Order
There are hardware IDs associated with each layer as displayed in TCE or the web
interface. For all layer types that can appear more than once in an eDAQ stack, the
hardware IDs have numbered suffixes starting with 1 and are assigned starting with
the layer that has the lowest layer address. For example, if there are two EBRG layers
in the stack with layer addresses 3 and 4, the layer with address 3 is referenced as
Brg_1, and the layer with address 4 is referenced as Brg_2.
HBM has adopted the convention of assembling the stack so that the hardware ID
suffix increases as the layer is positioned further away from the ECPU. In the example
above, the EBRG addressed at 3 with hardware ID of Brg_1 is closest to the ECPU. It
is strongly advised to follow this convention.
2.1.3 Updating Firmware
HBM regularly releases updates to the SoMat eDAQ firmware that expand
functionality and fix known bugs. To download compatible firmware and software, visit
www.hbm.com/somat.
NOTE
The eDAQ firmware uses an alpha-numeric version number (e.g., 3.11.A) while TCE
uses a numeric version number (e.g., 3.11.0). For compatibility, the first two numbers
of the eDAQ and TCE version numbers must be identical (e.g., 3.11).

After running the installer on the support PC to copy the files to the SoMat directory,
follow the steps below to upgrade the eDAQ firmware. Always update the ECPU
firmware before updating any layer level firmware.
CAUTION
If updating from an earlier release version, do not attempt to perform the upgrade if the
eDAQ is in need of time-critical testing. An upgrade failure of the eDAQ firmware can
render the eDAQ inoperable until it is upgraded at the factory.

SoMat eDAQ
30 I2740-2.1 en
Updating ECPU Firmware
To update the ECPU (MPB) firmware:
1. Power cycle the eDAQ.
2. Open the eDAQ web interface to the Hardware tab and click on the Code column
for the MPB. For more information on the eDAQ web interface, see eDAQ Web
Interface on page 187.
3. Browse to the correct firmware file on the PC and click Update. Wait for the eDAQ
to return to the ready state.
4. Refresh the web interface as it may change with the new firmware.
Troubleshooting the ECPU Firmware Upgrade
There are a few isolated reports of the web browser opening a window for an add-on layer when performing a firmware update
for the ECPU.
If this problem occurs, do the following:
1. Copy the firmware file and rename it as __e10-update.tar.gz. Note that the first two characters in the new file name
are underscores.
2. In the System tab of the web interface, select the option to transfer a file to the eDAQ.
3. Browse to the new file as the file to copy and enter / as the destination path on the eDAQ.
4. From the System tab, reset the eDAQ. The eDAQ reboots and updates the MPB firmware.

Updating Layer Level Firmware
To update layer level firmware:
1. Open the eDAQ web interface to the hardware table and click on the Code column
for the desired layer. For more information on the eDAQ web interface, see eDAQ
Web Interface on page 187.
2. Browse to the correct firmware file on the PC and click Update. Wait for the
application verified message indicating a successful update.
3. If no other firmware updates are required, cycle the power on the eDAQ to
complete the overall firmware update process.
NOTE
For more detailed procedures for each layer type and a listing of the current layer level
firmware versions see the instructions for installing eDAQ firmware provided with the
firmware installation.

2.2 Communications
2.2.1 Communications Methods
Ethernet Communications
Data transfer rates of up to 4 MB per second are possible using the 100BASE-T
Ethernet connection for communications between the eDAQ and its support PC. A
100BASE-T compatible Ethernet card must be installed in the support PC.
Connect the eDAQ to its support PC directly using the provided crossover cable
(1-E-Ethernet X/O-2) or through a network using the optional hub cable
(1-E-Ethernet HUB-2). Using a network removes proximity restrictions on the eDAQ
and support PC.
I2740-2.1 en 31
SoMat eDAQ
Serial Communications
The eDAQ supports an RS232 communications option. The default baud rate is
115200, configurable to lower baud rates to support serial bus modules. The serial
port can also be configured as a data input port using hardware and transducer
channel interfaces similar to vehicle bus inputs.
2.2.2 Changing the eDAQ IP Address and Host Name
In order to change the IP address or host name of the eDAQ, first establish
communication between the eDAQ and the support PC. The following sections
describe the appropriate steps to follow for each of the methods of communication.
Using an Ethernet Connection
To change the IP address and host name using an Ethernet connection:
1. Open a web browser on the support PC.
2. Enter the IP address of the eDAQ in the address field. The default IP address
programmed into the eDAQ nonvolatile memory during production is noted on a tag
attached to the eDAQ (typically 192.168.100.100).
NOTE
The support PC must be configured to be able to reach 192.168.100.100 from the
Ethernet port on the PC. This typically requires reconfiguration of the network
interface. Refer to your operating system documentation or see your network
administrator for help.

3. Click the System tab to open the eDAQ system setup page.
4. Select Network Setup to open the eDAQ network setup page.
5. Make changes to the hostname, IP address, netmask, and gateway. Check with the
network administrator for the appropriate settings for these fields. Use the dotted
quad format (xxx.xxx.xxx.xxx) for IP address, netmask, and gateway.
6. Click Reconfigure Network to save the changes to the eDAQ.
7. Cycle the power on the eDAQ for changes to take effect. The support PC must be
configured to allow continued eDAQ communications as noted in step 2 above.
For more information on the eDAQ web interface, see eDAQ Web Interface on
page 187.
Using a Serial Connection
To change the IP address and host name using a serial connection:
1. Power down the eDAQ and connect the serial communications cable to a PC COM
port.
2. Open the HyperTerminal application in Windows and follow the setup, entering a
name for the connection and selecting the COM port. In the Connect To property
page, use the Configure button to set up the communications protocols to a 115200
baud rate, 8 data bits, 1 stop bit, no parity and no flow control. In the Settings
property page, select the Auto Detect emulation mode.
3. Cycle the power on the eDAQ.
4. After some initial boot log messages, a string starting with is displayed. Press
ENTER four times to activate the login prompt. Login as setup with no password.
SoMat eDAQ
32 I2740-2.1 en
5. The eDAQ presents four network parameters available for modification: host name,
IP address, subnet mask and gateway. Each has a separate prompt with the
current/default value appearing in brackets after the description. Enter the new
value or press enter to accept the existing value for each of the four parameters.
6. After entering all the parameters, enter y to confirm the settings or n to cancel.
7. Reboot the eDAQ to complete the procedure and allow the modifications to take
effect.
NOTE
For complete access to all system tasks, login as root with no password. The
command line prompt character (#) is displayed. Issue Unix-based command lines to
perform required tasks.

CAUTION
All system firmware files and user data files can be deleted or corrupted by misuse of
commands at the root interface level. Only use the commands provided here or by
customer service to solve or troubleshoot eDAQ problems.

2.3 Power Considerations
The eDAQ requires an adequate power supply for the duration of all test runs. Consult
the following notes for important eDAQ power considerations.
CAUTION
If operating the equipment on a DC supply network, take additional precautions to
discharge excess voltages.

2.3.1 Input Power Voltage
Maximum Input Power Voltage
The maximum input power voltage is 55 volts for the ECPU-PLUS processor.
Exceeding the maximum input voltage for the eDAQ for more than a few milliseconds
results in a blown user-replaceable fuse.
The ECPU-PLUS processor supports nominal 12-, 24- and 42-volt vehicle battery
systems.
NOTE
The eDAQ fuses are 10-amp, 42-volt rated automotive mini-blade fuses. For the
eDAQ, spare fuses are stored in a compartment under the bottom panel fuse access
plate (new units are shipped with six spares in this compartment).

I2740-2.1 en 33
SoMat eDAQ
Minimum Input Voltage
The eDAQ requires a minimum of ten volts for boot up and a minimum of nine volts for
continuous operation once booted. After boot up, the eDAQ continues to operate for a
limited time at an input voltage down to six volts.
When the input power voltage drops below nine volts, which occurs during normal
vehicle engine cranking, the eDAQ switches in the internal backup battery as the
power source. Power continues to source from the internal battery until the input
voltage returns to ten volts or more. If the input voltage drops below six volts or the
eDAQ detects that the internal battery has limited remaining life, the eDAQ performs
an orderly power shut down. When input power voltage is restored to ten volts or more,
the eDAQ reboots and continues operation. A fully charged internal backup battery
contains enough reserve capacity to power an eDAQ stack drawing 50 watts in this
mode of operation for more than one minute.
NOTE
The above voltages are at the eDAQ power connector, which are always less than the
voltages at the power source because of some voltage drop in the wires used to route
the power supply voltage to and through the eDAQ power connector. These voltage
losses are dependent on the length and gauge of the connection wiring assembly.

Power Fail Shutdown
When a power fail shutdown initiates with a test run in progress, the eDAQ immediately
stops the test run and flushes all data in temporary buffers to the PC Card. This can
take several seconds. It is imperative that the backup battery is sufficiently charged to
keep the eDAQ running during this time. If this is not the case, data stored in the SIF
format becomes corrupted.
2.3.2 Battery Power
A fully charged eDAQ backup battery has at least 100 watt-minutes of reserve power.
It takes about four hours to fully recharge a completely discharged backup battery. The
battery charging circuit draws four watts maximum while charging. The backup battery
charger operates on an as needed basis. An intelligent charge controller monitors
current into and out of the backup battery, tracking the current charge state of the
battery. When the battery has discharged to about 92% of rated capacity and the
eDAQ is connected to a power supply at more than ten volts, the charger turns on and
runs until fully charged, normally a process of about 20 to 30 minutes.
An eDAQ that is turned off and connected to a power supply such as a vehicle battery,
runs one of these 20-minute charge cycles about once every two days, or an average
power drain of about 30 milliwatts (i.e., 2.5 milliamps at 12 volts).
When a battery is changed or disconnected and reconnected, the eDAQ detects the
new connection and assumes the battery to be discharged. The eDAQ initiates the
charge cycle upon connection to a power supply and runs until it detects a full charge.
NOTE
The eDAQ web browser interface provides a status indicator that shows the level of
battery charge as either low, medium or high and indicates whether the recharging
circuit is currently on or off.
SoMat eDAQ
34 I2740-2.1 en

2.3.3 Remote Power
The remote power switch cable from the eDAQ power connector acts as a three-way
switch in conjunction with the front panel power push button. Use the remote power
cable with a single pole, single throw contact switch. The two physical switches, the
front panel switch and the user-installed remote power switch, act to invert the
switching logic of the other. Choose to power the eDAQ with either an open or closed
remote power switch by simply toggling the front panel switch.
If not using remote power, ensure that the red and black wires are either fully insulated
from each other or solidly connected to each other to prevent accidentally turning the
power off. If the wires are connected to each other and there is any chance of magnetic
induction, do not coil the cable in a loop.
NOTE
Do not apply any voltage source to the auxiliary power switch cable. It is designed for
use with a single pole, single throw contact switch only.

Application Note: Using Remote Power to Start a New Test
The remote power switch can be used to force a reboot with a test running, effectively starting a new test run. The remote
power switch accomplishes this in a way that does not drain the backup battery since the main power supply is still on during
the duration of the power down operations. It is recommended to avoid other methods that turn off or disconnect the power
supply as this drains the backup battery and can result in SIF data corruption.

2.3.4 Powering an eDAQ from a Vehicle
The following sections illustrate the recommended power connections for using a
vehicle electrical system as the eDAQ power source. The included diagrams are not
intended to be complete, detailed instructions. Please read the entire section on eDAQ
power supply and backup battery considerations for a better understanding on the
limits and implementation of both main and remote power to an eDAQ unit.
CAUTION
Connection to the positive power terminal without proper grounding may result in a
blown fuse and/or other damage to the eDAQ.

NOTE
When using additional cable length to make the connections, select an appropriate
gauge wire to carry sufficient current ( 10 amps) and voltage ( 12 volts).

I2740-2.1 en 35
SoMat eDAQ
Non-Switching Battery Ground
The following diagram illustrates the proper method of powering an eDAQ with a direct
connection to a vehicle battery that has a permanent ground connection to the vehicle
chassis.
Figure 2-2: Vehicle battery connection for non-switching battery to ground.
An alternate method, shown below, uses a vehicle electrical system or harness which
may be a switching supply such as an ignition or a relay-type device. This method,
while feasible, is not recommended and cannot be guaranteed as safe. Results may
include unwanted multiple runs of data, improper reboots, lost data due to multiple
power cycles and improper charging of the internal battery pack.
Figure 2-3: Alternate vehicle battery connection for non-switching battery to ground.
Negative Battery Terminal Switching
For a system with a switched power system that removes the negative battery terminal
from the equipment chassis ground, carefully follow the illustrated recommendation.
Vehicle
Battery
+
-
Vehicle firewall
-V
+V
(black)
(red)
Remote Power
-V
+V
(black)
(red)
Main Power
eDAQ
SAC-EPWR15
Power
Vehicle
Battery
+
-
Vehicle firewall
-V
+V
(black)
(red)
Remote Power
-V
+V
(black)
(red)
Main Power
eDAQ
SAC-EPWR15
Power
SoMat eDAQ
36 I2740-2.1 en
CAUTION
Failure to follow these suggestions may result in blown fuses and/or permanent
damage to the eDAQ. Improper powering of the unit requiring repairs by HBM
technicians may be deemed as non-warranty usage, resulting in service charges.

Figure 2-4: Vehicle battery connection for switching battery to ground.
The figure below shows an example of improper powering that may result in a short
and damage the eDAQ.
Figure 2-5: Improper vehicle battery connection for switching battery to ground.
Vehicle
Battery
+
-
Vehicle firewall
-V
+V
(black)
(red)
Remote Power
-V
+V
(black)
(red)
Main Power
eDAQ
SAC-EPWR15
Power
Vehicle
Battery
+
-
Vehicle firewall
-V
+V
(black)
(red)
Remote Power
-V
+V
(black)
(red)
Main Power
eDAQ
SAC-EPWR15
Power
Vehicle firewall
+V
(black)
)
ower
Ma
SAC-EP
I2740-2.1 en 37
SoMat eDAQ
2.4 Data Storage
2.4.1 Data Formats
The eDAQ offers two formats for storing recorded data: SIE and SIF. Select which data
format to use in the TCE network setup window. A summary of the differences
between the SIE and SIF data formats follow.
For more information on using SIE and SIF in TCE, see Default data option on
page 54.
NOTE
For all storage media options, the eDAQ stores raw SIF test data and related
information in a set of individual component files referred to as SIC files using a fixed
naming convention (i.e., sif00000.sic, sif00001.sic, sif00002.sic, etc.). To view these
files, use the explore eDAQ files option in the web interface to navigate to the hd/eDAQ
directory. This is not recommended except under the advise of HBM support.

2.4.2 Data Storage Options
The ECPU contains several options for data storage including the RAM disk, an
internal CompactFlash card and DRAM memory. In addition, the eDAQ includes an
external PC Card slot.
NOTE
The external PC Card, internal CompactFlash and DRAM memory options are
referred to collectively as PC Card storage. For information on selecting the actual
media using the eDAQ web interface, see Select Storage Device on page 192.

RAM Disk
The RAM disk storage option has quite limited use in most test applications. The
default 3.5-MB size is usually much too small for sequential data storage or histogram
data storage of many test runs.
SIE SIF
Unlimited file size Files limited to slightly less than 4 GB
eDAQ can store multiple data files eDAQ can only store one data file
Data is readable during testing Data is readable only after test completion
No support for RAM disk data storage RAM disk data storage available
No support for max bursts mode for the Burst
History DataMode
Max bursts mode available for the Burst
History DataMode
No support for accumulating histogram data
across test runs
Support for accumulating histogram data
across test runs
SoMat eDAQ
38 I2740-2.1 en
The RAM Disk memory is a section of the volatile DRAM memory. This section of
DRAM memory is copied to the internal CompactFlash card on power downs or error
resets and then copied back to DRAM on boot up.
NOTE
The SIE format does not support data collection to the RAM Disk. Regardless of the
data storage setting, SIE data is saved to the storage device selected in the web
interface. If the PC Card storage device is selected and there is no PC Card in the
eDAQ, tests collecting SIE data cannot be initialized.

DRAM Memory
The amount of DRAM memory available for data storage is dependent on the size of
the socketed DRAM. The DRAM storage media option is applicable for limited testing
scenarios only. While it provides the maximum throughput compared to all other
storage modes, the DRAM memory is volatile. This means that the test data is lost if
the eDAQ powers down or resets for any reason, such as a power failure or error reset.
In these cases when the eDAQ sets the PCMAccessError flag and begins
re-initialization, use the Format RAM Disk menu option to restore normal operation.
CAUTION
DRAM memory is volatile. All test data is lost if the eDAQ powers down or resets for
any reason.

Internal CompactFlash
The eDAQ can use a disk partition on the internal CompactFlash for data storage. The
size of the internal Flash partition available for data storage is dependent on the size
of the internal Flash card. Note that about 32 MB of the internal Flash memory is
reserved for the eDAQ Linux OS.
The internal Flash storage media option provides up to five times better data
throughput than the external PC Card storage media option assuming the Flash card
uses DMA (as is the case for the HBM supplied cards). As such, this is the preferred
storage media for test applications when uploading the data from the support PC.
I2740-2.1 en 39
SoMat eDAQ
External PC Card
The eDAQ has an external PC Card slot compatible with original PCMCIA cards and
CompactFlash cards used with a PC Card extender. To open the door covering the PC
Card slot, loosen the screws holding the door closed. When done working with the PC
Card slot (e.g., swapping out a card), be sure to close the door and fasten the screws
tightly to prevent dust and moisture from entering.
NOTE
Some ECPU layers include dual PC Card slots. The eDAQ can only use one of the two
PC Card slots at any one time.

2.4.3 External PC Card
Usable PC Card Types
The eDAQ PC Card slot accommodates Type II and III cards in a variety of densities
with hard drive or flash-based memory.
NOTE
If the eDAQ will be used where it will be subject to vibration and movement, use a
flash-based memory PC Card instead of a disk drive card.

While many types of PC Cards work with the eDAQ, some do not work at all.
Furthermore, different brands and models of PC cards can have significantly different
data throughput characteristics. For reasons beyond the scope of this manual, older
PC Cards often perform better than newer PC Cards from the same manufacturer. It
is recommended to use the same types of PC Cards that HBM provides for current
production shipments. After thorough testing, HBM selects cards that optimize data
throughput.
Format Options
Use the eDAQ web interface or TCE to format the PC Card. In the Hardware tab, click
the storage link in the MPB row for details on the PC Card media. Then select the
Initialize/Format link to begin formatting.
If using a hard drive card, select either a Windows compatible MSDOS format or a
Linux format. The Linux format provides somewhat higher data throughput
performance and is recommended when uploading the data file from the eDAQ to the
PC. The MSDOS format is required to read the data from a Windows PC after
removing the card from the eDAQ.
NOTE
It is generally recommended to format the PC Cards using the eDAQ. However,
formatting the cards using the support PC in either the FAT or the FAT32 format
options is also acceptable.

SoMat eDAQ
40 I2740-2.1 en
PC Card Removal
After a test run is stopped, remove the external PC Card from the eDAQ only after it
has been logically unmounted. To unmount, power down the eDAQ, wait for all LEDs
to turn off and then manually eject the PC Card.
CAUTION
Ejecting the external PC Card without going through the above procedure can often
corrupt the test data.

Once ejected, do not reinsert the card into the eDAQ for data upload. Instead, insert
the card directly into a Windows or Linux PC Card slot. For SIE files, simply copy the
file to the PC. For SIF files, transfer the SIC files to the PC and then use TCE to
consolidate the SIC files into a standard SIF file.
Swapping PC Cards with a Test Initialized
The eDAQ supports the capability to swap in a new PC Card and re-initialize a test that
was previously initialized, effectively storing a test run across multiple PC Cards. There
is no limit to the number of swapped cards. The data file on each card is a complete
file, allowing analysis independent of any other data files. When swapping cards, the
eDAQ maintains contiguous test run number sequencing, prerun rezeroing offsets for
applicable transducer channels, interactive trigger states and remote test run control
states.
NOTE
This option is not available for a set of eDAQs.

To swap PC Cards with a test initialized, carefully follow this procedure.
1. With a test initialized and a test run either in progress or stopped, power down the
eDAQ and wait for the power sequence to complete.
2. Insert the new, previously formatted PC Card. The new PC Card must be purged
of all SIF data component files.
3. Power on the eDAQ. The existing test is re-initialized and the next test run starts
automatically unless using the remote control mode.
NOTE
If a PC Card is swapped in without purging the SIF component files, the eDAQ does
not attempt to re-initialize the test run. Instead, it sets the PCMAccessError flag, turns
on the red LED and effectively goes into an idle state. In this situation, power down the
eDAQ, insert a purged PC Card or the original PC Card and power on the eDAQ. Test
re-initialization then proceeds normally.

I2740-2.1 en 41
SoMat eDAQ
2.5 Networking eDAQ Systems
Networking allows multiple eDAQ units to acquire data synchronously using a single
master sample rate (MSR) clock source. The networked system can consist of any
combination of eDAQ and eDAQlite systems. For more information on data
synchronization in a network of systems, see Networked eDAQ System
Synchronization on page 242.
2.5.1 Hardwired Network
This section describes how to set up the eDAQ hardware for networking. For
information on using TCE to manage an eDAQ network, see Networking eDAQ
Systems on page 92.
Required Hardware
For (n ) eDAQ systems, the following hardware is required and assumes Ethernet
communications mode. A hardwired network consists of one master eDAQ and (n -1)
slave units.
(n ) Networking Adapter Cables (1-SAC-ESYNCADAPT-2)
(n -1) Networking Sync Cables (1-SAC-ESYNC-2)
(2) Networking Termination Connectors (1-SAC-ESYNCTERM-2)
1 - 100BASE-T Ethernet hub with n +1 ports
Hardware Connections
Referring to the diagram below, the SoMat SAC-ESYNCADAPT Networking Adapter
Cable (1-SAC-ESYNCADAPT-2) is a communications cable that includes two cable
stubs with LEMO connectors which provide a tee connection to the data
synchronization clock. The master eDAQ supplies the clock and distributes it to each
slave through the SoMat SAC-ESYNC Networking Sync Cables (1-SAC-ESYNC-2).
For the each of the end units, connect one side of this tee to a SoMat
SAC-ESYNCTERM Networking Termination Connector (1-SAC-ESYNCTERM-2).
Figure 2-6: Cable connections for networking multiple eDAQs.
eDAQ1
Comm
eDAQn
Comm
eDAQ2
Comm
.....
TERM
Ethernet hub
SAC-ESYNC
SAC-ESYNCADAPT
SAC-ESYNCADAPT
1 2 n ...
SAC-ESYNC
TERM
SoMat eDAQ
42 I2740-2.1 en
2.5.2 Wireless Network
With a GPS module in either an EDIO or ECOM layer, it is possible to configure the
eDAQ to generate the MSR clock synchronized with the GPS timing signal. This mode
of operation allows multiple eDAQ systems to wirelessly synchronize data. Use this
option only when the GPS module can maintain consistent GPS lock.
To set up GPS MSR clock generation, select the network mode as GPS Stand Alone
(see Adding a Network Node on page 63), configure the EDIO or ECOM hardware
to enable GPS clock generation (see EDIO Configuration Options on page 100) and
define at least one GPS channel in the test setup (see Bus-Oriented Input Channels
on page 135).
The test run start time is required to align the data acquired from different eDAQ units.
The eDAQ logs the start time in terms of GPS time in the data file under the global
keyword DF_GPSStartRunTime_#, where # is the run number. The format for the
date and time follows the ISO 9161 standard in the format
YYYY-MM-DDThh:mm:ss.sssshhmm.
NOTE
Because the eDAQ writes the start time based on UTC (Universal Time Coordinates),
the final hhmm of the start time, which is the signed offset from UTC, is always +0000.

Use the GPS Master network mode for the ECOM layer to generate the GPS clock for
itself and one or more hardwired slave eDAQ systems. Connect the slave eDAQs as
described for normal hardwired networking.

I2740-2.1 en 43
SoMat eDAQ
3 Test Control Environment (TCE)
The SoMat Test Control Environment (TCE) software, provided with the eDAQ, is an
interface between the eDAQ and the support PC. Use TCE to:
Create test setup files that define transducer channels, computed channels and
DataModes for online data analysis
Perform and manage calibrations for input transducers
Initialize, run and end tests on a single eDAQ or a network of eDAQs
View real time test data with integrated run-time displays
Monitor eDAQ memory status during data acquisition
Transfer test data from the eDAQ to the support PC for analysis
Configure the option to remotely control test runs
This chapter describes the TCE user interface and preferences. For details on using
TCE to perform the listed tasks and more, see Using TCE on page 63.
3.1 TCE User Interface
The following sections describe the TCE user interface including the setup windows,
pull-down menus, toolbar and status bar.
3.1.1 Setup Windows
Create and modify TCE files using the five setup windows. Access any of the button
options in the windows using the mouse or the keyboard entry indicated by the
underlined character. For example, select the Add button by either clicking on it or
pressing A on the keyboard. Select multiple entries using the standard CTRL and
SHIFT keystrokes.
Figure 3-1: TCE setup windows for a new test setup file.
Test ID/Network Setup
The upper test identification section of the window shows the descriptive name of the
test, the name of the operator, the test date and any notes or comments regarding the
test or special instructions. The lower network setup portion of the window contains
the eDAQ or the list of eDAQs for the test setup and their network node parameters.
SoMat eDAQ
44 I2740-2.1 en
For more information on setting up a network node, see Adding a Network Node on
page 63.
Hardware Setup
The hardware setup window lists the hardware layers installed on the systems
specified in the network setup. Each layer entry includes the front panel connector ID
names, the layer serial number, the firmware (code) version number, an indication of
applicable ECNs and select configuration details. Use the Query button to populate
the list.
For more information on using TCE to configure hardware, see Configuring the
Hardware on page 64. For more information on the configuration options for specific
hardware, see eDAQ Hardware on page 95.
Transducer Channel Setup
Use the transducer channel window to define and modify the transducer configuration
required for the test. This includes defining transducer identification information,
user-programmable settings and calibration methods and parameters. Each
transducer entry includes the transducer ID name, the connector, the transducer
sample rate, the calibration date, the output data type and select configuration details.
Option Description
Edit ID Modify the test identification information shown in the upper window.
Import Import a network node definition from an existing TCE setup file. TCE
also imports all hardware modules, transducer and computed
channels and DataModes associated with the network node.
Add Add a network node to the existing TCE setup file. Specify an IP
address or host name and communication parameters.
Del Delete an existing network node from the TCE setup file. TCE also
deletes all hardware modules, transducer and computed channels and
DataModes associated with the network node.
Edit Modify an existing network node definition.
Data Option Select the desired data file format. For more information on data
format options, see Default data option.
Manage SIE Files Launch the eDAQ web interface to manage the SIE data files on the
eDAQ. For more information on managing SIE files, see SIE Test
Data on page 193.
Option Description
Query Load the hardware setup from the systems specified as network
nodes. TCE issues a prompt if the queried hardware configuration
differs from the current setup.
Config Display and/or edit the configuration details for the selected hardware
layer. Configuration options are not available for all layers.
I2740-2.1 en 45
SoMat eDAQ
For more information on setting up an input channel, see Creating Channels and
DataModes on page 65. For information on specific input channel types, see Input
Channels on page 117.
Computed Channel Setup
Use the computed channel window to define any computed channels required for the
test. A computed channel is derived from one or more transducer or previously defined
computed channels. Defining computed channels in a test setup is optional.
NOTE
A computed channel referencing a previously defined computed channel must be
listed below the referenced channel in the setup window.

Option Description
Add Add a new transducer definition to the setup. TCE adds the new
transducer above the selected entry.
Del Delete the selected transducer channels.
Edit Modify the selected transducer channel definitions. Edit a single
transducer definition or a group of transducers of the same channel
type.
Copy Copy the selected transducer definition into one or more new
transducer definitions. TCE adds the new transducers below the
selected entry.
Sort Sort the transducer channels list alphabetically by connector ID.
DVM Run a DVM display for the selected transducer channels. This option
is not available when a test is initialized. For more information on the
DVM display, see DVM on page 82.
Scope Run the scope display for the selected transducer channel. The scope
display is limited to a single channel. This option is not available when
a test is initialized. For more information on the scope display, see
Scope Plot on page 83.
Freq Run the spectrum analyzer display for the selected transducer
channel. The spectrum display is limited to a single channel. This
option is not available when a test is initialized. For more information
on the spectrum display, see Spectrum Plot on page 84.
Cal Perform various calibration tasks on the selected transducer channels.
This option is not available when a test is initialized. For more
information on calibrating channels, see Calibrating Input Channels
on page 67.
Ampl Report the selected signal conditioner amplifier settings. This option is
provided primarily for HBM development.
SMART Utils Open the SMART module utilities window. This option is applicable for
a SMART module transducer channel. For more information on
SMART utilities, see Using SMART Utilities on page 131.
SoMat eDAQ
46 I2740-2.1 en
For more information on setting up a computed channel, see Creating Channels and
DataModes on page 65. For information on specific computed channel types, see
Computed Channels on page 143.
DataMode Setup
Use the DataMode window to define the DataMode configuration required for the test.
A DataMode definition consists of a list of input channels, a data sampling rate,
triggering mode and conditions and other DataMode specific parameters.
For more information on setting up a DataMode, see Creating Channels and
DataModes on page 65. For information on specific DataMode types, see
DataModes on page 173.
3.1.2 Pull Down Menus
The following table describes the menu options available in TCE. Where applicable,
the last column provides a section number in this document for more information on
the menu command.
NOTE
To perform any tasks in the FCS Setup menu, the PC must be connected to the eDAQ
specified in the TCE communications preferences.

Option Description
Add Add a new computed channel definition to the setup. TCE adds the
new computed channel above the selected entry.
Del Delete the selected computed channels.
Edit Modify the selected computed channel definition.
Copy Copy the selected computed channel definition into a new computed
channel. TCE adds the new channel below the selected entry.
Option Description
Add Add a new DataMode definition to the setup. TCE adds the new
DataMode above the selected entry.
Del Delete the selected DataModes definitions.
Edit Modify the selected DataMode definition.
Copy Copy the selected DataMode definition into a new DataMode
definition. TCE adds the new channel below the selected entry.
Mem Display the SIF data raw memory allocated for the selected DataMode
definition.
I2740-2.1 en 47
SoMat eDAQ
Menu Menu Option Description Section
File New Setup [CTRL+N] Create a new setup file. 4.1
Open Setup [CTRL+O] Open an existing setup file. 4.1.4
Save Setup [CTRL+S] Save the currently open setup file.
Save Setup As Save the current setup file with a new name and/or location.
Save Setup Listing Generate a readable listing file containing current setup information.
Save Setup Tab Delimited Generate a tab-delimited text file of current hardware setup. Provided
primarily for HBM internal use.
Open SIE or SIF File Extract keyword and message channel data from an existing SIE or
SIF file.
4.6.3
Consolidate SIC Files Generate a complete SIF file from a set of SIF component files (SIC
files).
Call Infield/EASE/DataXplorer
[CTRL+D]
Start InField, EASE or DataXplorer for displaying and/or analyzing
test data.
Exit Quit TCE.
Recent Files View a list of the five most recently opened TCE files.
SoMat eDAQ
48 I2740-2.1 en
Test Control Control Panel [CTRL+0] Open the TCE control panel. 4.3
Get Test Status [CTRL+1] Check the current test status of the eDAQ. 4.4
Initialize Test [CTRL+2] Initialize the eDAQ in preparation for the test run. 4.3.1
Remote Control [CTRL+R] Suspend or resume remote control operation. 4.7
Preview Run Start a test run with all DataModes storage suppressed. 4.3.3
Start Run [CTRL+3] Start a test run. 4.3.4
Prerun Options... Access a variety of tasks after initialization. 4.3.2
Transducer Checks Perform a variety of checks on transducer channels.
Rezero Display [CTRL+Z] Display and re-zero transducer channels for an initialized test.
Reference Shunt Checks Check the repeatability of shunt calibrations.
Install Shunts Install shunt calibration resistors during a test run.
Interactive Triggering [CTRL+4] Open a dialog to control the values of the eight available interactive
triggers.
4.3.5
Run Time Display [CTRL+5] Open the run-time display window. 4.5
Stop Run [CTRL+6] Stop a test run. 4.3.6
End Test [CTRL+E] End the current test run. 4.3.7
Auto Range Options Configure the option to automatically use the minimum and maximum
values recorded in the last test run as the full-scale values in future
test runs.
3.2.8
Upload Test Data [CTRL+7] Transfer all or selected test runs stored in the eDAQ to a
user-specified PC disk file.
4.6
Upload SIE Only Transfer SIE data files stored in the eDAQ to a user-specified PC disk
file.
4.6.1
Upload SIF Only Transfer the SIF data file stored in the eDAQ to a user-specified PC
disk file.
4.6.2
Upload Test Setup Transfer the test setup file stored in the eDAQ to a user-specified PC
disk file. This option is not available when a test is running.
Save AOM File Generate a file that contains the calibration parameters required to
relate analog outputs to equivalent engineering units values.
4.2.4
Menu Menu Option Description Section
I2740-2.1 en 49
SoMat eDAQ
FCS Setup Set Master Sample Rate Specify the master sample rate (MSR) as either 100000 Hz, the
standard MSR for the eDAQ, or 98304 Hz, provided to support power
of two sample rates. Data sample and data storage rates must be
integer divisors of the MSR. The eDAQ stores the MSR in nonvolatile
memory for access only after an eDAQ reset. Therefore, TCE initiates
a programmed reset of the eDAQ unit when the parameter changes.
Set Reset Options Control options for initiating system resets. The only applicable option
is the no new run on FCS error reset option which prevents the eDAQ
from attempting to start a new test run when a serious error forces a
reset. For normal operation, do not select this option so that the eDAQ
can attempt to salvage as much of the test run as possible. This
option is not available when the test is initialized.
Set Clock Set the real time clock on the eDAQ unit based on the current date
and time setting on the host PC.
Reset Perform a programmed reset of the eDAQ unit. Use this option only if
absolutely necessary, such as when the system is not responding.
Delete RAM Disk Files Delete all resident test and data files from the RAM disk. Only use this
option if there is no test initialized on the eDAQ and all test data has
been safely uploaded from the eDAQ.
Format RAM Disk Format the RAM disk on the eDAQ unit and erase all files, including
some test data files, from the RAM disk. This option is available at all
times even while a test is running. Because the eDAQ formats the
RAM disk in the normal process of test initialization, formatting the
RAM disk is not typically necessary.
10.1
Diagnostics Access commands for troubleshooting purposes. 10.1
Test FTP Perform a diagnostic test on the eDAQ file transfer process (FTP)
functionality. This option is not available when a test is initialized.
Check RAM Disk Check the integrity of the eDAQ RAM disk.
Upload Log Save the eDAQ log, which contains messages, warnings and errors
from TCE and the eDAQ, to a PC disk file.
Preferences Communication Preferences Configure the Ethernet communications with the eDAQ. 3.2.1
General Preferences Configure TCE application preferences. 3.2.2
FCS Specific Preferences Configure TCE preferences specific to the target eDAQ. 3.2.3
Remote Test Run Control Configure the preferences for using remote control. 3.2.4
Scope and Spectrum Configure the settings for scope and spectrum displays. 3.2.5
Run Time Display Configure the settings for run-time displays. 3.2.6
Group DVM Display Configure the settings for group DVM displays. 3.2.7
Menu Menu Option Description Section
SoMat eDAQ
50 I2740-2.1 en
3.1.3 Toolbar
The TCE toolbar provides quick access to commonly used TCE functions. Each button
also provides a guide to commonly used keyboard shortcuts.
View Toolbar Show/hide the TCE toolbar. 3.1.3
Status Bar Show/hide the TCE status bar. 3.1.4
Test ID/Network Setup Show/hide the test ID/network setup window. 3.1.1
Hardware Setup Show/hide the hardware setup window. 3.1.1
Transducer Channels Setup Show/hide the transducer channels setup window. 3.1.1
Computed Channels Setup Show/hide the computed channels setup window. 3.1.1
DataMode Setup Show/hide the DataMode setup window. 3.1.1
Window Cascade Cascade all open windows.
Tile Tile all open windows.
Arrange Icons Arrange all minimized windows at the bottom of TCE.
Close All Close all windows.
Next Window Activate next window.
Previous Window Activate previous window.
Toggle Maximized Maximize or restore active window.
Help Contents [Ctrl+H] Open the table of contents for the contextual help system. This help
can also be accessed from various TCE windows. Note that if using
Windows 7 or Windows Vista, this help requires the WinHlp32.exe
application available from Microsoft.
eDAQ Manual Open the HTML version of the eDAQ and eDAQlite manuals.
Menu Menu Option Description Section
Button Command Button Command
New setup. [CTRL+N] Initialize test. [CTRL+I]
Open setup. [CTRL+O] Start preview run. [CTRL+P]
Save setup. [CTRL+S] Start test run. [CTRL+3]
Open hardware setup window. [F1] View run-time data. [CTRL+5]
Open transducer channel setup
window. [F2]
Stop test run. [CTRL+6]
I2740-2.1 en 51
SoMat eDAQ
3.1.4 Status Bar
The status bar is at the bottom of the TCE window and displays information about the
test setup status. The status bar is divided into three sections.
Communications Mode
The communications mode displays the IP address or host name of the active eDAQ.
When TCE is actively communication with the eDAQ, the background color of the
entire status bar changes. When communicating with the eDAQ specified in the TCE
communications settings, the status bar turns red. When communicating with other
eDAQs for network control or monitoring purposes, the status bar turns either blue,
green, yellow or orange based on the assigned index to the network node.
Test Modified
The test modified section indicates, by displaying the word Modified, that the current
test setup has been modified from its last saved state.
General Information
The general information indicator provides TCE status information with a brief
description of the current action or the action just completed.
3.2 TCE Preferences
The TCE Preferences menu provides a variety of options to modify some aspects of
TCE including dialog window displays, remote test run control configuration and TCE
warning messages. TCE saves the preference settings in a file named TceMS.ini in
the working subdirectory of the installation folder.
Open computed channel setup
window. [F4]
Upload test data. [CTRL+7]
Open DataMode setup window.
[F3]
End test. [CTRL+E]
Open control panel. [CTRL+0] Get eDAQ log. [CTRL+L]
Get test status. [CTRL+1] Call Infield/EASE/DataXplorer.
[CTRL+D]
Open help. [CTRL+H]
Button Command Button Command
SoMat eDAQ
52 I2740-2.1 en
3.2.1 Communications
Connect Timeout Period
Specify the desired timeout period in seconds for initiating communications with the
eDAQ. The default value of five seconds should work well for dedicated ethernet
communications with an eDAQ that is not on a network hub. Longer timeouts may be
required for communications with an eDAQ on a busy or slow network hub or on a
wireless ethernet connection.
NOTE
The communications I/O timeout, used for all PC to eDAQ communications, equals the
connect timeout period for periods greater than ten seconds. Otherwise, TCE sets the
I/O timeout period to the minimum timeout period of ten seconds.

Socket Buffer Size
Specify the buffer size used for PC to eDAQ communications. In general, leave the
default value of 61440 bytes for optimum communications data throughput. For
situations where timeouts on communications occur, increasing the timeout period is
recommended over decreasing the socket buffer size.
IP Address or Host Name
Specify the IP address or host name of the desired eDAQ.
3.2.2 General
Descriptions (not IDs) for data file (plot) labels
Store the TCE channel description fields in the data file for use as labels on plot
windows. When selected, empty or duplicate channel descriptions prompt warnings
from TCE. Modifying this option is not available after test initialization.
NOTE
Although TCE description fields allow 63 characters, data file labels are limited to 31
characters. Because the Rainflow and Peak/Valley Matrix DataModes add prefixes to
the labels, it is recommended to limit the description field to 24 characters when using
these DataModes.

Require user to verify test control selections
Force TCE to issue a verification prompt after every Test Control menu command.
Chain auto range options to stop test run
Require TCE to open the auto range options dialog after each test run stops. For more
information on auto range options, see Auto Range Options on page 60.
Chain SIF frame demultiplex to upload/consolidate (SIF Only)
Force TCE to demultiplex all multiplexed SIF file data records after successful upload
or SIC consolidation. This option significantly improves data analysis performance by
products such as InField. Note that TCE does not perform the demultiplexing if there
are any abnormalities in the upload or consolidation.
I2740-2.1 en 53
SoMat eDAQ
Prompt user for run descriptions on test run starts
Force TCE to issue a prompt for a test run description at the start of every test run. As
this option is the only method of entering test run descriptions, deselecting it ensures
blank test run description fields.
Require user to verify PC card purge during test initializations
Force TCE to issue a verification prompt in order to purge the PC Card during test
initialization. If not selected, TCE purges the PC Card automatically.
NOTE
If multiple SIE files exist on the eDAQ, TCE issues the verification prompt regardless
of the preference setting.

Allow test initializations with channels that are not calibrated
Allow TCE test initializations with non-calibrated transducer channels. This option is
not applicable to strain transducer channel types.
Auto set current communication preference on TCE setup file open
When opening a TCE setup file, automatically set the current communication
preferences. If the existing preference matches any network node defined in the
opened file, the preference remains unchanged. Otherwise, TCE sets the active eDAQ
to the master network node or, if no master exists, the first defined network node.
Warn user if...
Warn user about unused channels
Select one of three options of when TCE should issue a warning about unused
channels.
Warn user if... Description
Ratio of Calibration
Span to Full-Scale
Span <
Issue a warning if the calibration span is less than the specified
percent of the full-scale span for a transducer channel (or vice-versa).
Difference Between
Host PC and FCS
Clocks >
Issue a warning if the difference between the host PC real time clock
and the eDAQ real time clock exceeds the specified number of
minutes.
Deviation of Shunt
Calibration Volts from
Ideal >
Issue a warning if the measured shunt calibration span in volts
deviates from the ideal shunt calibration by at least the specified
percentage.
SoMat eDAQ
54 I2740-2.1 en
Analog output file format options
Select one of three options of which file format to use when generating analog output
calibration files.
For more information on analog output calibration files, see AOM Calibration File on
page 73.
3.2.3 FCS Specific
Default pipe frame rate
Select the default pipe frame rate from the provided list. The first number of each entry
is the rate for an MSR of 100000 Hz and the second number is the rate for an MSR of
98304 Hz. As data samples are collected from the transducer channels, the eDAQ
places them in blocks of data (data frames) and routes (pipes) them into computed
channels and DataModes. In the flow of data from the transducer inputs through the
DataModes, the data frames are referred to as pipe frames.
The lowest pipe frame rate is considerably more efficient from a processing point of
view when there are a large number of channels defined at lower sample rates
( 500 Hz). Using the lowest pipe frame rate also modestly improves throughput
performance for most tests with sample rates below 10000 Hz. At sample rates above
10000 Hz, a higher pipe frame rate generally results in the best throughput
performance. Because TCE run-time displays run at the pipe frame rate, higher pipe
frame rates may be desired.
Default data option
Select the default option for how the eDAQ stores data. For more information on the
SIE and SIF data formats, see Data Formats on page 37.
Option Description
If channel is not used
in a DataMode or
computed channel
Issue a warning when any defined channel is not either used a
computed channel or stored in a DataMode.
If channel is not used
in a DataMode
Issue a warning when any defined channel is not stored in a
DataMode.
Do not issue
warnings
Never issue a warning.
Option Description
Use original file
format.
Generate a Windows INI compatible file.
Use tab-delimited file
format.
Generate a tab-delimited file compatible with Excel.
Ask user for desired
file format on each
usage.
Prompt for a file format decision for each generated file.
I2740-2.1 en 55
SoMat eDAQ
NOTE
The diagnostic data options are provided primarily for HBM internal usage.

Check actual full scales
Force TCE to check the actual full-scale limits for all selected channels defined in the
test. Choose to check ELLB, EHLS or EBRG channels. TCE performs the check
immediately after test initialization and reports if the over range protection meets the
conditions below. For more information on full-scale values, see Full-Scale Values on
page 118.
Enable min-max tracking for Time History DataModes
Track min and max values for each input channel in a Time History DataMode. This
option is not recommended for optimum throughput performance, but it is required to
support TCE auto range functionality. For more information on auto range options, see
Auto Range Options on page 60.
Option Description
SIE (delete old SIE
files on test init)
Collect data in the SIE file format and limit the number of SIE files on
the eDAQ to one, emulating the behavior of SIF files.
SIE Collect data in the SIE file format and allow multiple SIE files on the
eDAQ at the same time.
SIF Collect data in the SIF file format. Only one SIF file is allowed on the
eDAQ at one time.
SIE and SIF
(diagnostic, delete
SIE)
Collect data in both the SIE and SIF file formats and limit the number
of SIE files on the eDAQ to one. This option consumes eDAQ storage
twice as fast and places significantly increased demand on the eDAQ
processor.
SIE and SIF
(diagnostic)
Collect data in both the SIE and SIF file formats. This option consumes
eDAQ storage twice as fast and places significantly increased demand
on the eDAQ processor.
Option Description
Low Level Warn if over range protection on ELLB channels is less than 5% or
greater than 25%.
High Level SS Warn if over range protection on EHLS channels is less than 1% or
greater than 25%.
Bridge Warn if over range protection on EBRG channels is less than 1% or
greater than 25%.
SoMat eDAQ
56 I2740-2.1 en
Use PC Card memory for remote RAM disk storage
Store the static part of the RAM disk file on the PC Card. This effectively limits the size
of the RAM disk file and helps prevent a situation where the RAM disk memory fills up
before the PC Card memory.
NOTE
When this option is selected, the ability to upload individual test runs is disabled.

Use default sample rate/filter for all low level calibrations
Select this option to use the default sample rate and digital filter combination of a
low-pass, 8-pole Butterworth filter with a 15 Hz break frequency for all ELLB channel
calibrations. If unselected, TCE uses the sample rate and digital filter currently defined
in the channel definition.
Shunt calibration mode options
Select the desired mode for performing ELLB channel shunt calibrations. The smart
range mode is the default and the recommended mode. Both the fixed range and auto
range modes are older modes maintained from previous versions of TCE.
Mode Description
Smart Range This is the default mode. TCE makes a coarse voltage measurement
to determine the approximate the bridge output with no shunt resistor
installed (i.e., the bridge imbalance). This measurement is accurate to
about 0.1 millivolts. Based on this value and the computed ideal
voltage offset for an installed shunt resistor, TCE sets up the low level
channel signal conditioner with an over range of either 12.5% of the
ideal range or 1 millivolt, whichever is greatest. Then TCE acquires
both un-shunted and shunted voltages to provide a very high
resolution and fast calibrations. This mode is very general in that it
supports all bridge and shunt resistance and can handle large bridge
imbalances up to 100 millivolts.
Fixed Range This mode provides the fastest shunt calibrations. TCE sets up the low
level channel signal conditioner for a fixed range of 40 millivolts. Then
TCE acquires both un-shunted and shunted voltages. This modes
supports most 120-, 350- and 1000-ohm bridges using shunt resistors
that provide equivalent strains in the 1000- to 4000-microstrain range.
However, it does not provide optimal resolution and cannot handle
bridges with large imbalances.
Auto Range This mode provides maximum resolution for both un-shunted and
shunted voltage measurements, but is also the slowest mode. TCE
makes a coarse voltage measurement to determine the approximate
voltage with the shunt resistor installed. TCE sets up the low level
channel signal conditioner with the offset D/A converter configured to
compensate for this voltage and the gains set to the maximum. TCE
then acquires a highest resolution precision voltage measurement to
set the shunted voltage value. TCE repeats the process with the shunt
resistor removed to set the un-shunted voltage value. This mode can
handle very large bridge imbalances up to 500 millivolts.
I2740-2.1 en 57
SoMat eDAQ
Following are some timing benchmarks for the three modes as a function of the
sample rate and digital filter used. In all cases, the values are the time in seconds
required to shunt calibrate 16 channels (i.e., all eight channels on two ELLBs). Note
that the time required to shunt calibrate eight channels on one ELLB or 32 channels
on four ELLBs is:
Enable Backup Battery Interlocks on Test Runs
Select this option to enable the backup battery option in the ECPU configuration
options by default. For more information battery interlocks, see Battery Power on
page 33.
3.2.4 Remote Test Run Control
The remote control setup preferences configure the eDAQ for remote control of test
runs using digital input and output lines. The eDAQ uses the digital input and output
lines on the ECPU for remote control operation.
After selecting Remote Test Run Control from the Preferences menu, choosethe
eDAQ-Plus option to modify the following preferences. For more information remote
test control, see Using Remote Control Operation on page 91.
NOTE
Changing these preferences after a test is initialized does not affect the remote control
operation for the test currently in progress.

Modify current test setup settings only
Change the remote control parameters in the current test setup only. When this option
is disabled, all parameters are saved as TCE defaults. TCE applies the default settings
to all new setup files and files without defined remote control parameters. Previously
defined parameters retain their values taking precedence over the application defaults.
Control mode
Select the desired remote control mode.
Sample Rate / Digital Filter Smart Range Fixed Range Auto Range
100 Hz / Butterworth 15 Hz 30 seconds 23 seconds 41 seconds
100 Hz / Linear Phase 33 Hz 27 seconds 21 seconds 38 seconds
200 Hz / Linear Phase 67 Hz 21 seconds 16 seconds 28 seconds
500 Hz / Linear Phase 167 Hz 17 seconds 13 seconds 21 seconds
1000 Hz / Linear Phase 333 Hz 14 seconds 11 seconds 17 seconds
2500 Hz / Linear Phase 1000 Hz 12 seconds 10 seconds 17 seconds
Option Description
Disable Do not use remote control.
Enable Use remote control for all subsequent tests.
Query Choose whether to use remote control at each test initialization.
SoMat eDAQ
58 I2740-2.1 en
Input bit assignment
Select the desired run/stop control bit. If the line for this bit is high (logical 1), a test run
starts; when the line goes low (logical 0), the test run stops.
NOTE
With the remote control mode in use, all digital input lines for the ECPU can function
as normal digital inputs.

Optional output bit assignments
There are four status outputs available; all are optional.
NOTE
To support remotely powered LED indicators, the eDAQ switches output lines to
ground for the on state and to open circuit for the off state.

NOTE
When using any of the optional output bits for eDAQ remote control operation, the
digital outputs on the ECPU are not available.

3.2.5 Scope and Spectrum Display
The scope and spectrum display options allow changes in the color schemes and
other presentation parameters for both run-time displays and the original displays
used when a test is not running. For more information on scope and spectrum
displays, see Viewing Channel Displays on page 79.
Trace color
Select the desired color for drawing signal trace vectors.
Output Description
Running Indicates the test running state. Flashing indicates running, steady on
indicates starting or stopping a run and steady off indicates no test run
in progress.
Alarm Indicates a serious error or user alarm. TCE always reports the
specific error or warning condition on the next interaction with the
eDAQ. Note that running out of either RAM or PC Card memory sets
this alarm.
RAM Low % Indicates when the available RAM disk memory falls below the
user-specified limit.
PCM Low % Indicates when the available PC Card memory falls below the
user-specified limit.
I2740-2.1 en 59
SoMat eDAQ
Screen color
Select either black or white as the background screen color.
Auto scale mode
Automatically scale the y-axis. As spectrum displays always use auto scale, this option
is only applicable to scope displays.
Show grid lines
Activate visible grid lines on the plot.
Show prerun value
Start the display showing the prerun value when present. This option is only applicable
to the scope displays.
3.2.6 Run-Time Display
Use the run-time display preferences to set a default run-time display type and
configure display options for the bar and strip chart display. For more information on
run-time displays, see Viewing Channel Displays on page 79.
Display mode
Select the preferred display mode to use as the default when opening a run-time
display.
NOTE
To modify the display parameters for scope and spectrum plots, use the scope and
spectrum display preferences. The digital readout display has no display options.

Trace/bar color
Select the desired color for drawing the signal traces or bars.
Screen color
Select either black or white as the background screen color.
Strip chart plot mode
Select the desired behavior when the signal trace reaches the right edge of the plot.
Show strip chart grid lines
Activate visible grid lines on the strip chart plot.
3.2.7 Group DVM Display
Select one of three display modes for group DVM displays.
Option Description
Normal The signal trace begins again at the left side of the plot.
Scroll The signal trace scrolls continuously to the left at the rate at which data
is received and with the current value at the right edge.
Mixed The right half of the signal trace moves to the left half of the plot and
the signal trace continues from the middle of the plot.
SoMat eDAQ
60 I2740-2.1 en
3.2.8 Auto Range Options
NOTE
Access the auto range options from the Test Control menu.

NOTE
Automatically chain this task to the stop run task using TCE General Preferences.

Use the auto range options to acquire the minimum and maximum values for all
channels stored in Time History DataMode in the eDAQ resident SIE or SIF file. This
includes all transducer channels and all computed channels that have the full-scale
values defined. The information is displayed on a run-by-run basis. The initial dialog
window presents the results from the last run. Select to display other runs as desired.
The channels are sorted in the order of full-scale saturation percent (i.e., how close
the channel is to either of the user-defined full-scale limits). This option is available
whenever the SIE or SIF data file is resident in the eDAQ.
There are also options provided to auto range the full-scale definitions based on the
minimum and maximum values reported for each channel for any given run. To use
this functionality, highlight the desired channels in the list box complete the following
control fields.
Range Multiplier %
Use the range multiplier to set some range padding on the auto range assignments. If
this parameter is set to 100%, the full-scale limits are set to the minimum and
maximum values acquired for the test run. The default value of 200% sets the full-scale
values so that the resulting full-scale range is double the range of the acquired data.
The minimum value is 10% which might be used if the acquired data exceeds the
original full-scale limits. If ensuing test runs are expected to be very consistent with the
trial test run used for auto ranging, it may be desirable to use a smaller padding value
(e.g., 125%).
Option Description
Original Static Use static control fields and limit to a maximum of 16 channels.
Scroll List Use a scrollable list control with sizable fields: channel ID, current
value and units. Limit to a maximum of 256 channels.
Scroll List Extended Use a scrollable list control with sizable fields: network, connector ID,
channel ID, current value, saturation bounds and units. Limit to a
maximum of 256 channels.
I2740-2.1 en 61
SoMat eDAQ
Keep Original FS Means (kom)
Check this option to maintain the original full-scale mean values. This typically results
in a loss of dynamic range, but may be required for certain applications. The range
multiplier parameter is used as described above to ensure that sufficient padding is
provided on both ends of the full-scale definition.
Auto Set
Select the auto set option to apply the defined auto range parameters to the selected
set of channels. TCE updates the list box. This option can be used as often as
necessary to assign different subsets of channels different auto range parameters.
Save TCE Setup
Select this option to compute the new full-scale settings and save them in a new TCE
setup file. TCE asks for the save file name and issues a report after saving the file. The
report lists the new full-scale settings for each channel that has been auto ranged.
There are two situations where TCE overrides the user-defined auto range settings.
4. The hardware imposes limitations on most full-scale settings. For example, signal
conditioners that have voltage inputs are limited by the A/D converter range. TCE
automatically imposes these restrictions on any auto-ranged transducer channel.
5. TCE limits auto range changes that magnify the original full-scale range to be no
more than a factor of 1000. This is required to avoid numerical problems with data
channels where the minimum and maximum values acquired are the same or very
nearly the same.
NOTE
In some special situations, the same transducer or computed channel may be stored
in more than one Time History DataMode. In this case, TCE uses the first occurrence
(in relation to the definition order in the TCE setup file) of the duplicated channel for
display and auto range operations.

SoMat eDAQ
62 I2740-2.1 en
I2740-2.1 en 63
SoMat eDAQ
4 Using TCE
The following chapter provides detailed information on performing the various tasks
available using TCE. These include defining a test setup, calibrating transducer inputs,
running a full test, monitoring eDAQ status and transducer inputs before, during and
after test runs, uploading test data for analysis, configuring remote control operation
and setting up a network of eDAQ systems.
4.1 Defining a Test
Use the TCE setup windows to define a new test or modify an existing test. The steps
involve in defining a test include: specifying one or several eDAQ systems used in the
test by creating a network node or a set of network nodes; configuring the hardware
layers and modules installed on the defined nodes; and adding transducer channels,
computed channels and DataModes to acquire, manipulate and store test data.
4.1.1 Adding a Network Node
To add an eDAQ network node and define its communications and network
configuration, select Add in the test ID/network node window. For a single eDAQ test,
add one network node. For a set of networked eDAQ systems add a network node for
each eDAQ in the test.
NOTE
If using only a single eDAQ, this step is optional. A hardware query updates all
required fields in the network node setup according to the current communications
preferences.

IP Address or Host Name
Specify the IP address or host name of the desired eDAQ.
Connect Timeout Period
Specify the desired timeout period in seconds for initiating communications with the
eDAQ. The default value of five seconds should work well for dedicated ethernet
communications with an eDAQ that is not on a network hub. Longer timeouts may be
required for communications with an eDAQ on a busy or slow network hub or on a
wireless ethernet connection.
NOTE
The communications I/O timeout, used for all PC to eDAQ communications, equals the
connect timeout period for periods greater than ten seconds. Otherwise, TCE sets the
I/O timeout period to the minimum timeout period of ten seconds.

Socket Buffer Size
Specify the buffer size used for PC to eDAQ communications. In general, leave the
default value of 61440 bytes for optimum communications data throughput. For
situations where timeouts on communications occur, increasing the timeout period is
recommended over decreasing the socket buffer size.
SoMat eDAQ
64 I2740-2.1 en
Network Mode
Select one of the available network mode options detailed in the table below. There
can only be one master (Master, GPS Master, or Megadac Master) in the test setup
file. There can be any number of slaves. For more information on networking using
TCE, see Networking eDAQ Systems on page 92.
For more information on the EDIO configuration options used for the GPS and
Megadac modes, see EDIO Configuration Options on page 100. For more
information on the ECOM configuration options used for the GPS modes, see ECOM
Configuration Options on page 98.
4.1.2 Configuring the Hardware
Use the hardware setup window to add, view and configure all hardware layers and
modules installed on the defined network nodes.
Adding eDAQ Hardware
Add eDAQ hardware automatically, using the Query option, or manually, using the Add
option.
Select Query in the hardware setup window to obtain entries for the installed
hardware. If the queried configuration differs from the current hardware setup, choose
to update the list or abort the query when prompted. TCE also issues an alert for any
flags set by the eDAQ since the last query. The Query option is only available when an
eDAQ is connected to the support PC.
To manually add eDAQ hardware, click Add in the hardware setup window. Use this
method to define a complete eDAQ system from scratch.
Deleting eDAQ Hardware
Use the Del option in the hardware setup window to delete the selected hardware
layers and modules from the existing hardware list. TCE also deletes any transducer
channels, computed channels or DataModes associated with the selected layer or
module.
Network Mode Description
Master The eDAQ ECPU generates the MSR clock for itself and all other
connected slaves defined in the test setup.
Slave The eDAQ does not generate the MSR clock. A master eDAQ (or other
clock source) must route the MSR clock to the eDAQ.
Stand Alone The eDAQ ECPU generates the MSR clock for itself only.
GPS Stand Alone The GPS on the eDAQ EDIO or ECOM layer generates the MSR clock
for itself only. The EDIO or ECOM layer must be configured to generate
the MSR clock.
Megadac Master The eDAQ ECPU or EDIO layer generates the MSR clock for itself and
all other slaves defined in the test setup and supplies a derived clock
to drive the Megadac. The EDIO layer must be configured to generate
the MSR clock.
GPS Master The GPS on the eDAQ EDIO or ECOM layer generates the MSR clock
for itself and all other slaves defined in the test setup. The EDIO or
ECOM layer must be configured to generate the MSR clock.
I2740-2.1 en 65
SoMat eDAQ
Configuring eDAQ Hardware
Double click an entry or select Config to open the hardware configuration options.
Several of the hardware layers and modules offer user-configurable settings while
others only show characterization details. For information on specific configuration
settings available for each layer or module, see eDAQ Hardware on page 95.
NOTE
The thermocouple layers (EITB and ENTB) and the power controller do not offer any
configuration options.

Hardware with user-configurable settings:
ECPU
Serial Bus (ECPU)
EDIO
ECOM
Vehicle Bus (EHLB, EDIO and ECOM)
GPS (EDIO and ECOM)
NOTE
Serial bus configuration settings are only available when a custom module is installed
using the web interface. For detailed instructions on installing several different custom
modules, see the installation instructions provided with the firmware installation.

Hardware with viewable characterization details only:
EBRG
EHLS
EHLB
ELLB
Network camera
4.1.3 Creating Channels and DataModes
Adding Channels and DataModes
Transducer channels, computed channels and DataModes are all added and modified
in much the same way. In the appropriate window, click Add to add a new channel or
DataMode. TCE first presents a list of the types of channels or DataModes. Selecting
the desired type opens the configuration window for that type of channel or DataMode.
When adding a transducer, TCE presents a list of common channel configurations.
Select a pre-defined or blank configuration from the list. Either option allows
modification. For more information on specific parameters for each channel and
DataMode see chapters Input Channels on page 117, Computed Channels on
page 143, and DataModes on page 173.
Copying Channels and DataModes
When creating many channels or DataModes with similar properties, use the Copy
option available in each window. For computed channels and DataModes, TCE only
allows the creation of one copy at a time.
SoMat eDAQ
66 I2740-2.1 en
For transducers, TCE allows the creation of multiple copies. The number of copies
defaults to the maximum allowed. TCE automatically assigns a connector to each a
new channel. Choose the default IDs mode as detailed below.
Modifying Channels and DataModes
To modify the parameters of an existing channel or DataMode, highlight the desired
definitions and select Edit or double click the definition entry. For computed channels
and DataModes, TCE limits the edit operation to one definition at a time.
For transducers, TCE allows group edits for a set of channels of the same type. After
selecting edit, choose which set of parameters to modify. The available parameters
vary depending on the type of channel.
Deleting Channels and DataModes
Delete a single definition or a set of definitions by simply highlighting the desired
channels or DataModes and selecting Del. Note that any computed channel or
DataMode that uses a deleted channel as an input remains listed but is no longer a
valid definition.
4.1.4 Using Existing Setup Definitions
TCE provides several methods for using the setup information from existing setup and
data files. These include simply opening and modifying a previously saved test setup,
extracting setup and supporting files from a SIE or SIF data file and importing defined
network nodes.
Modifying an Existing Test
Opening and modifying an existing test setup file is probably the most common mode
of defining test after creating an initial test from scratch. To open a previously saved
file, select Open Setup from the File menu or toolbar. Modify the setup as desired
using the same methods described for creating a file. To save the setup to a different
file, select Save Setup As from the File menu.
To support setup files generated outside of the TCE software, TCE validates the setup
file fields on every open setup command. Specifically, TCE validates all fields
associated with the DataMode, computed channel, transducer channel and test ID
modules. The hardware modules are not validated under the assumption that they will
be updated using a hardware query. TCE generates a log file in the TCE working
directory that contains a list of warnings and errors found during validation.
Default IDs Mode Description
All Fields Blanked Create the copies with blank ID names. Manually enter the ID names
in the next window.
All Fields Same as
Original
Create the copies with ID names identical to the original channel. Edit
the ID names in the next window such that there are no duplicates.
Numeric Increment
(Suffix)
Create the copies with an increasing numeric suffix in the ID name. If
desired, edit the ID names in the next window.
I2740-2.1 en 67
SoMat eDAQ
Notes on Using Setup Files from Previous TCE Versions
Consider the following when using setup files from previous versions of TCE.
Serial bus channels defined in TCE setup files prior to V3.8.2 are invalid. Delete these channels from the setup file and
add them from the new serial bus databases provided with later releases.
TCE automatically updates J1708 channels created using the original J1587 version of the database. Note that TCE
removes all vehicle speed, latitude, longitude and altitude channels if they exist in the TCE setup file.

Importing a Network Node
The network setup window provides an option to import previously defined network
node from a saved TCE setup file into the existing setup. Select Import in the network
setup window to begin the import process. Importing a network node extracts all the
information associated with the node including hardware, transducer and computed
channels and DataModes.
TCE does not import any channels or DataModes with ID names identical to existing
channels or DataModes in the defined test. If this situation occurs, delete the newly
imported node, rename the duplicate IDs in the existing setup or in the setup
containing the network node and import the node again.
Extracting a Setup from a Data File
To extract a TCE setup file from a SIE or SIF data file, select Open SIE or SIF File from
the File menu. After choosing the desired data file, select Keyword Extraction Options
and then TCE Setup File to PC File. Save the file and open it in TCE as any other
previously saved setup file.
4.2 Calibrating Input Channels
Transducer calibration for the eDAQ system is independent of a specific signal
conditioner or hardware layer. The transducer calibration definition is solely in terms of
the relationship between the transducer output signal (i.e., voltage for most transducer
types) and the selected engineering units. Note that this relationship is dependent on
the excitation settings, the use of an excitation signal and the bridge settings for
applicable types of transducer channels.
For a transducer that has not been calibrated, indicated by a No as its calibration
date, select Cal in the transducer channel setup window to begin calibration. For
calibrated transducers, select Cal to perform one of several calibration control options.
NOTE
For some channel types, TCE completes the calibration date parameter when the
channel is created. To calibrate these channels, first delete the calibration by selecting
Cal and choosing the Delete Calibration option.

4.2.1 Calibration Modes
Modify the calibration mode on the second page of the channel definition window,
accessible with the Edit option or by double clicking the channel. The two mode
parameters define the two steps required to uniquely determine the calibration line
SoMat eDAQ
68 I2740-2.1 en
which represents the linear relationship of engineering units to the input signal. Define
either two calibration points (values) or one calibration point (value) and a calibration
slope (span).
With the two calibration steps properly defined, select Calibrate to perform the actual
calibration. Upon completion, TCE sets the calibration date to the current date and
disables the parameters related to calibration.
General Calibration Modes
Select one of four available calibration modes for generic transducers.
NOTE
For EHLS, EBRG, ELLB and EHLB input channel types, TCE supports the option to
perform parallel calibrations if the calibration is defined with either two external values
or one external value and one defined span. If multiple channels have this calibration
definition, TCE asks if the calibrations should be performed in parallel or serially.

Example Calibration
Suppose an inductive pickup is used on a flywheel with 180 pickups. To output RPM, calibrate the channel with the following
definitions:
Defined Value : Eng Units [0 RPM] == Sig Units [0 Hz].
Defined Span : Eng Units [60 RPM] == Sig Units [180 Hz].

Shunt Span Modes
Low level signal conditioner transducers (EBRG, Strain SMART Module and ELLB)
offer additional mode options. These modes are all based on an internally applied
shunt resistor to simulate strain or load.
Cal Mode Description
External Value Define a single point on the calibration line. When prompted during the
actual calibration run, apply the transducer signal value equivalent to
the specified engineering units value. The eDAQ measures the signal
value.
External Span Define the slope of the calibration line. When prompted during the
actual calibration run, apply two transducer signals that differ by the
specified engineering units value. The eDAQ measures the two signal
values and computes the slope of the calibration line in engineering
units per signal units.
Defined Value Define a single point on the calibration line. Enter both the transducer
signal value and the engineering units equivalent.
Defined Span Define the slope of the calibration line. Enter both the transducer signal
value span and the engineering units equivalent of the span.
I2740-2.1 en 69
SoMat eDAQ
These options define the slope of the calibration line. Enter the engineering units
equivalent for the span. The eDAQ internally applies the selected shunt resistor across
one arm of the bridge and measures the preshunt and postshunt signal voltages.
Notes on Shunt Span Modes
The eDAQ stores the precise values for each of the shunt resistors in nonvolatile memory on the hardware layer. The
eDAQ performs the necessary computations to compensate for each shunt resistor's deviation from the exact values
presented in the above list.
For EBRG or Strain SMART Module channels, use the Install Shunts option in the Test Control menu to install the shunt
calibration resistors during a test run or preview. Use the test run data to quickly verify that all applicable channels are
nominally calibrated. While this data can also be used to verify calibration accuracy in a strict sense, this is a more
complicated process that requires knowledge of actual excitation voltage and actual shunt resistor value. There is no
option to remove the shunt resistors, but the eDAQ always removes shunt resistors when preparing for a new run, a
channel display or any calibration task. For networked eDAQ systems, the shunt resistors are installed sequentially
from one network node to the next.
NOTE
Although this task requires a fairly small amount of eDAQ processing, it can result in
a DeviceOverFlow error reset for tests running at the edge of the eDAQ processing
limit.

An internal shunt resistor applied across the +Ex to -Sig leg of the bridge results in a downscale shunt. In other words,
the voltage output from the bridge swings in the negative direction when the shunt is applied. Take this into
consideration when setting the sign of the associated engineering value.
If the measured voltage span and the theoretical ideal voltage span do not agree within the specified percentage found
in the TCE General Preferences, TCE issues a warning message.

Preshunt Value
Specify a preshunt value to define a single point on the calibration line in conjunction
with one of the shunt span modes (e.g., 40-kilohm span). Enter the engineering units
equivalent. The voltage used is the preshunted voltage measured in the shunt span
step. This mode is recommended to reduce the entire calibration to one step.
Channel Additional Modes
ELLB 10-kilohm span, 20-kilohm span, 40-kilohm span,
80-kilohm span, 160-kilohm span, 320-kilohm span,
640-kilohm span, 1.28-megohm span
EBRG 50-kilohm span, 100-kilohm span, 200-kilohm span,
500-kilohm span
Strain SMART
Module
50-kilohm span, 100-kilohm span
SoMat eDAQ
70 I2740-2.1 en
Shunt Tools
For a bridge channel, use the shunt tools option as a guide to indirectly select a shunt
span mode (e.g., 40-kilohm span) with an associated engineering equivalent value.
The two options for shunt calibration are based on a known shunt calibration or gage
and bridge factors.
For a shunt calibration based on a known shunt, enter the shunt resistor and
corresponding engineering value (e.g., a 33.2-kilohm shunt that produces a
2200-pound output). TCE initially highlights the shunt resistor that results in the closest
engineering value. Select the desired calibration step definition based on the strain
values expected in the field.
The equivalent engineering values for the shunt resistors use the following equation.
where, V
e
is the equivalent engineering units value, V
k
is the known engineering units
value, R
g
is the nominal gage resistance, R
sk
is the known shunt resistance and R
se

is the equivalent shunt resistance.
NOTE
Be careful to ensure that the known shunt calibration applies to the same leg of the
bridge circuit that used in the shunt calibration; otherwise, the polarity of the computed
shunt span may be inverted.

A shunt calibration based on the gage and bridge factors calculates a shunt resister
using the gage factor of the active strain gage and bridge factor for the bridge
configuration defined with the channel parameters. Select the desired calibration step
definition based on the strain values expected in the field. The shunt tool assumes that
the engineering units are microstrain. If using dimensionless strain units, divide the
equivalent strain value by 1000000.
The equivalent strain uses the following equation.
where, E
s
is the equivalent strain in microstrain units, R
g
is the nominal gage
resistance, G is the gage factor and B is the bridge factor.
NOTE
If the shunt target results in a downscale shunt, E
s
is multiplied by -1.

NOTE
Changing the bridge type, bridge resistance, shunt target, gage factor or bridge factor
invalidates the computed equivalent strain. Run the shunt tool again after changing
these parameters.

I2740-2.1 en 71
SoMat eDAQ
Multi-Point Cal
The multi-point calibration mode is available for EBRG and EHLS channels only. When
beginning a calibration with the multi-point cal mode selected, follow the instructions
on the series of configuration windows to fully define the calibration. Define anywhere
from 3 to 16 calibration points for TCE to acquire and least squares fit to determine the
best linear fit calibration slope and offset. Once the calibration is completed, TCE
creates two defined values based on the user-defined full-scale min and max.
Defined mV/V
The defined mV/V calibration mode is available only for low level signal conditioner
transducers (EBRG, Strain SMART Module and ELLB). Use the defined mV/V mode
to normalize the slope of the calibration line to the excitation range. The actual slope
of the calibration line, typically referred to as a sensitivity factor, is the ratio of the
engineering units value divided by the product of the excitation range and the signal
units value.
4.2.2 Calibration Control
Access the calibration control options by selecting to calibrate an already calibrated
channel. Use calibration control to perform various transducer calibration tasks
including check calibration, zero adjust calibration, or delete calibration.
Check Calibration
The check calibration option performs a calibration run and displays a graph and
numeric data comparing the original calibration with the one just performed. For one
channel, the calibration check window shows the maximum deviation and the defined
and measured calibration values. For two or more channels, the summary window
shows each channels maximum deviation in both engineering units and percentage
of full-scale range. Click the More Info button to show the calibration check window for
the highlighted channel.
NOTE
The calibration check does not account for zero adjustments done after the original
calibrations.

Zero Adjust Calibration
The zero adjust calibration allows adjustments for small differences between the
original zero setting used in calibration and the zero setting required for actual
measurement. This is useful to compensate for zero drift common with many input
channels.
SoMat eDAQ
72 I2740-2.1 en
First, enter the engineering value equivalent to the current input channel states. Next,
the eDAQ measures the current input channel outputs and offsets the calibration lines
as required to yield the specified engineering value. Performing a zero adjust
calibration adds a tilde (~) to the end of the transducers calibration date.
NOTE
Use the zero adjust option only when necessary and then only for very small
adjustments. Because the zero setting is permanently modified, consider recalibrating
the channel instead of using this option.

NOTE
For quadrature decoder channels, the eDAQ resets the internal counter value to zero
before performing a zero adjust.

Delete Calibration
Delete the calibration to clear the calibration date field and modify calibration-related
parameters before recalibrating the channel.
Shunt Calibration Loop
The shunt calibration option, primarily for HBM development purposes, verifies the
reliability and accuracy of ELLB shunt calibrations. It is available only for ELLB
channels that use shunt calibrations. This task has no affect on existing calibrations.
4.2.3 Calibration Specifications
EHLS and EBRG Channels
To measure calibration signal voltages for EHLS and EBRG channels, the eDAQ down
samples the A/D converter subsystem by a factor of 1000 or 960 (depending on the
MSR) to 100 or 102.4, respectively, using a Butterworth 8-pole digital filter with a 15-Hz
break frequency. The eDAQ manipulates the signal conditioner gains and offsets in an
auto ranging mode to yield near maximum resolution of the input signal (i.e., the eDAQ
sets the gains as high as possible). The eDAQ acquires one A/D sample to determine
the signal voltage of the input channel.
High Level Channels
For most high-level input channels (i.e., high level, pulse counter, vehicle bus, serial
bus and GPS input channels), the eDAQ acquires a set of data samples at the
user-specified sample rate and averages these to provide a single signal value for
calibration purposes. If the sample rate is 50 Hz or more, the eDAQ uses 100 data
samples. Otherwise, the uses a number of data samples equal to twice the sample
rate (down to the minimum of one data sample).
Thermocouple Channels
For standard and isolated thermocouple input channels, the eDAQ uses only one data
sample to provide a single signal value for calibration purposes.
I2740-2.1 en 73
SoMat eDAQ
ELLB Channels
To measure calibration signal voltages for ELLB input channels, the eDAQ down
samples the A/D converter subsystem by a factor of 1000 or 960 (depending on the
MSR) to 100 or 102.4, respectively, using a Butterworth 8-pole digital filter with a 15-Hz
break frequency. The eDAQ manipulates the signal conditioner gains and offsets in an
auto ranging mode to yield near maximum resolution of the input signal (i.e., the eDAQ
sets the gains as high as possible). The eDAQ averages ten A/D samples to determine
the signal voltage of the input channel.
NOTE
Override the defaults described above using the low level calibration options in the
TCE FCS Specific Preferences.

4.2.4 AOM Calibration File
HBM offers the EHLS, EBRG and ELLB layers with an optional analog out function to
provide high level analog output signals for each channel. Select Save AOM File from
the Test Control menu to generate a PC file that contains the calibration parameters
required to relate the high level analog outputs of the EHLS, EBRG and ELLB signal
conditioners to equivalent engineering units values.
This option is available only after a test run has been started because the eDAQ does
not maintain the analog signal conditioner circuitry in a fixed state after a test is
initialized. For example, when a new test run starts, the eDAQ temporarily disconnects
the signal input lines from the front panel connector leads and shorts them to ground
to account for amplifier offsets and other sources of offset. Furthermore, if calibration
checks are performed after the test is initialized, the analog circuitry for those
transducers are in a significantly different state after the checks and remain in this
state until there is a requirement to change the analog circuitry setup (such as starting
a test run, running the rezero display, etc.). Although the analog outputs calibration
parameters are often quite consistent from test run to test run, this may not always be
the case and should definitely not be presumed.
There are two file format options available to store the analog output calibration file
parameters. The original file format is discussed in detail below. The second file format
is a tab delimited file format that is Excel compatible. It contains the same information
as the original file format, but is organized differently. It also has the ELLB channels
sorted alphabetically by connector ID.
The original analog output calibration file is written in a standard Windows initialization
file format (i.e., it can be read using the GetPrivateProfileString() function provided in
Windows). Following is a fragment of a typical original AOM file with added comments.
The numbers in brackets are the maximum string lengths - this includes the null
terminator. All numeric fields are floating point.
SoMat eDAQ
74 I2740-2.1 en
[Main]
SetupFile=c:\tce\test.tce TCE setup file path [256]
RunNumber=1 Test run number
NumXdcrChs=4 Number of transducers
[XdcrCh_1] For the 1st transducer...
ID=RF_Wheel_Fz Transducer channel ID [13]
NodeName=eDAQ05 Network Node Name [256]
Connector=LoLev_1.c01 Hardware connector ID [13]
Units=lbs Engineering units string [16]
Scale=984.571 Cal slope (eng units / volts)
Offset=-0.00179932 Cal intercept (eng units @ 0
volts)
Eng_FSMin=-10000 Engineering units Full-Scale
Min
Eng_FSMax=10000 Engineering units Full-Scale
Max
Volts_FSMin=-10.1567 AO voltage @ Full-Scale Min
Volts_FSMax=10.1567 AO voltage @ Full-Scale Max
[XdcrCh_2] For the 2nd transducer...
ID=RF_Wheel_Fy Transducer channel ID [13]
(and so on...)
4.3 Running a Test
Use the controls in the Test Control menu or in the toolbar to perform test run tasks.
Alternatively, use the Control Panel, opened from the Test Control menu, for quick
access to common test run tasks. The Control Panel also shows a continuously
updating display of the amount of RAM and PC Card memory available for data
storage.
Figure 4-1: TCE Control Panel for quick access to test run tasks.
I2740-2.1 en 75
SoMat eDAQ
Running a test using the existing test setup definition consists of the following steps.
4.3.1 Initializing a Test
The initialization process prepares the eDAQ for a test run. Select Initialize from the
Test Control menu or toolbar to begin initialization which consists of the following
steps.
Verify that the current test setup is saved to a disk file and there are no internal
inconsistencies in the test setup such as uncalibrated channels or unresolved
ID references.
Check that the eDAQ real-time clock agrees with the real-time clock in the
support PC within the user-specified tolerance.
Purge the eDAQ RAM disk and PC Card, removing previous test setup and SIF
data files.
Transfer the required test setup files to the eDAQ.
Set up the eDAQ signal conditioner excitation circuits, allowing the maximum
time for the excitation circuits to stabilize before the test run starts.
Create the data file and write some of the header fields.
For transducer channels with programmable gains and offsets, check the actual
full-scale limits to verify that the over range protection is sufficient. TCE issues
a warning for any unusual situations as specified in the TCE General
Preferences.
4.3.2 Prerun Options
After initialization and before starting a test run or between test runs, there are a
number of prerun options available through the Prerun Options sub-menu of the Test
Control menu.
Transducer Checks
The transducer checks option provides the ability to run the DVM, scope or spectrum
displays or perform calibration checks. Select the desired channel or channels from
the list and the preferred option using the radio buttons and then click Run to execute
the option for the selected transducer or transducers.
Option Description
Calibration Check Run a calibration check. Note that the calibrations are the current
transducer calibrations which may differ from the calibrations defined
at test initialization if the transducer has been rezeroed. Check for this
difference using the rezero offset option.
DVM Display Run the DVM display.
Scope Display Run the scope display.
Spectrum Display Run the spectrum display.
Rezero Offset View the differences between the current transducer calibration
intercepts and those defined at test initialization. For each transducer
channel, this difference is the cumulative sum of all rezero offsets in
engineering units since test initialization.
SoMat eDAQ
76 I2740-2.1 en
Rezero Display
Use the rezero display to view and rezero the defined transducer channels. Select the
desired channel or channels and click OK. TCE continuously reads and displays the
current transducer signals in engineering units. Select the hold option to pause display
updates or use the scroll bar at the right of the window to adjust the display update
rate. The rezero display also shows the prerun rezero value defined for the transducer
in the test setup and indicates in the (A) column if the transducer is to be rezeroed just
prior to the next test run. To manually rezero a channel, select the transducer in the
(B) column and click the rezero button or press ALT+R.
Reference Shunt Checks
Use the reference shunt checks option to perform shunt resistor checks on ELLB
transducer channels that are defined with the reference shunt option enabled. The
shunt check information includes the transducer channel ID, the last check span in
engineering units stored in the data file and the difference between the minimum and
maximum shunt check spans in engineering units. Select more info to view a more
detailed report of the shunt checks on the highlighted channel. To run another shunt
check, select run shunt check.
NOTE
The eDAQ stores the shunt check information file in a global keyword accessible area
of the SIE or SIF data file. For more information on extracting this file, see Extracting
Data from SIE or SIF Files on page 89.

NOTE
The shunt span calculations do not correct for leadwire resistance effects or the slight
deviations of the actual shunt resistances from the nominal resistances. Therefore, the
stored shunt spans are not as accurate as the calibration shunt spans are more than
sufficient for documenting changes in transducer response from run to run.

NOTE
If the voltage readings for any shunt check span exceeds the limit for the type of signal
conditioner, TCE tags the reported span as invalid by marking it with a -? string.

4.3.3 Previewing a Test Run
A preview run effectively starts a test run with all DataMode storage suppressed. All of
the transducer channels and computed channels run in preview mode just as they
would during a data collection run. To start a preview run, select Preview Run from the
Test Control menu or toolbar.
I2740-2.1 en 77
SoMat eDAQ
4.3.4 Starting a Test Run
To start a test run, select Start Run from the Test Control menu or toolbar. The SoMat
eDAQ supports multiple test runs for an initialized test. Start a new test run anytime
after a previous run stops or during a preview run. When starting a test run, TCE
presents a start test run dialog window displaying the next run number and allowing
the input of a short run description (up to 63 characters per run).
NOTE
Use TCE General Preferences to suppress the start test run dialog window.

The data acquired on multiple runs is stored in a single SIF data file. Each channel of
acquired data is tagged with the designated run number.
Run descriptions are stored in a fixed 2048 character record of the SIF data file
allocated when the test is initialized. The run descriptions can be extracted from the
SIF data file using an EASE procedure file that is resident in the TCE installation
directory.
4.3.5 Using Interactive Triggers
TCE interactive triggers allow user input from the software to control a computed
channel or DataMode through the use of an Interactive Trigger computed channel.
There are eight Boolean logic controls available which must be assigned to an
Interactive Trigger computed channel. When the test is initialized, TCE sets all the
triggers to FALSE. Select Interactive Triggering from the Test Control menu to control
the trigger states before or during a test run. Use the check box by each trigger index
and clack Apply Triggers Now to change the trigger state. A check indicates a TRUE
state. TCE grays out the triggers not defined in the test setup. To invert the trigger logic
(i.e., a check for a FALSE state), use the invert trigger parameter in the Interactive
Trigger computed channel. For more information on the Interactive Trigger computed
channel, see Interactive Trigger on page 160.
NOTE
The eDAQ maintains the trigger states through power fail or error reset test run
restarts.

4.3.6 Stopping a Test Run
Manually stop the current test run by selecting Stop Run from the Test Control menu
or toolbar or use the Test Run Stopper computed channel to automatically stop a test
run based on triggering conditions. For SIF files, certain post run tasks may be
required before the test is actually stopped. If the PCM storage option is in use, the
SIF post run tasks consist of ensuring that the SIF component files on the PC Card are
completely flushed and closed. There are no post run tasks for SIE data files.
SoMat eDAQ
78 I2740-2.1 en
4.3.7 Ending a Test
To end a test run, select End Test from the Test Control menu or toolbar. Ending a test
prevents starting a new test run until after re-initializing the eDAQ. This option is
available when a test is initialized and no test run is in progress. Data files are still
available for upload after ending a test.
4.4 Monitoring Test Status
Select Get Test Status from the Test Control menu or toolbar to display the state of the
current test and eDAQ data storage. The provided indicators are described below.
Category Indicator Description
Test Run Status Test Initialized Indicates that a test is initialized on the eDAQ.
Remote Control If a test is initialized, indicates the status of the remote control mode as
either disabled, enabled or suspended.
Run # If a test is initialized, indicates the current run number or the next run
number if no test is running.
Run or Preview Started Indicates that a test run or preview is in progress.
Run Time If a test run or preview is in progress, indicates the elapsed time since the
start of the run. The elapsed time display rolls over after 1000 hours.
Post Run Tasks Indicates that a test run is stopped, but the required post run tasks are not
completed.
RAM Disk Files Origin Indicates the original TCE name of the current test setup file.
Setup Indicates the eDAQ reference name of the current test setup file.
Data Indicates the name of the current SIF data file. Note that even when using
only SIE data, the eDAQ retains a very small RAM disk-based SIF file for
internal purposes.
RAM Disk Memory
(in bytes and percent total of
RAM disk memory)
Total Indicates the total RAM disk memory on the eDAQ.
SIF File Indicates the current size of the resident SIF data file.
Unused Indicates the unused memory available for data file storage.
PC Card Disk Memory
(in bytes and percent of total
PC Card memory)
Total Indicates the total memory on the PC Card.
SIE File Indicates the cumulative size of the SIE data files currently on the PC Card.
SIF File Indicates the cumulative size of the SIF component data files current on
the PC Card.
Unused Indicates the unused memory on the PC Card available for data file
storage.
SIF File limited to Indicates the maximum allowable size for the SIF file.
SIF File Built on PC Card If PC Card data storage is in use, indicates that the SIF file has been
consolidated and the PC Card can be removed from the eDAQ after
powering down.
I2740-2.1 en 79
SoMat eDAQ
4.5 Viewing Channel Displays
TCE includes a variety of integrated run-time displays to view real-time data from input
channels and computed channels during a test run. TCE also offers a several signal
display types to view transducer input signals when a test run is not in progress.
4.5.1 Displays Overview
Channel displays are available before initialization, as a prerun option and as run-time
displays during a test run.
NOTE
When applicable, always define the excitation circuitry before displaying the
transducer signal.

Pre-Initialization Before initialization, TCE can display transducer channels
before or after calibration. The eDAQ uses the user-defined sample rate and
digital filtering. The display types available before initialization are DVM, scope
plot and spectrum plot (i.e., Freq). Access all three types in the transducer setup
window. The DVM and scope plot displays are also accessible in the display
control section on page two of the transducer channel definition dialog box.
PrerunThe DVM, scope plot and spectrum plot display modes are available
as prerun options after initialization and before the first test run or between test
runs. To access the displays, select Transducer Checks from the Prerun Options
sub-menu of the Test Control menu.
Run TimeRun-time displays show the raw signals from input and computed
channels on a real-time basis providing verification that input and computed
channels are functioning properly. Run-time displays are only available while a
test is running. The available run-time display types are bar chart, strip chart,
digital readout, scope plot and spectrum plot. Access the display modes from
the Run-Time Displays option in the Test Control menu or toolbar.
NOTE
TCE stores the run-time display channel set and display mode in a RAM disk file.
When restarting a run-time display during a test, TCE starts the display in the last used
configuration.

The following table presents a summary of the displays in TCE, when they are
available and the maximum number of channels each supports.
SoMat eDAQ
80 I2740-2.1 en
NOTE
The maximum number of channels allowed for a group DVM display depends on the
display mode selected in the Group DVM Display Preferences. For more information
on these preferences, see Group DVM Display on page 59.

Notes on Run-Time Displays
Run-time data is acquired using two different methods depending on the display mode. The digital readout, bar chart and strip
chart displays use the min-max data acquisition method while the scope and spectrum plots use the contiguous block data
acquisition method.
Min-Max Method:
When the run-time display starts, the eDAQ continuously monitors each channel, tracks the minimum and maximum
signal values and holds those values in a buffer. Periodically, TCE polls the eDAQ to get the minimum and maximum
values. After the eDAQ sends the values to TCE, it resets the min-max search so that the next read gives the minimum
and maximum values since the last read.
A min-max display runs continuously on the eDAQ while the display is opened and examines all data samples in the
min-max search. Though the display was designed to minimize the overhead on the eDAQ, it does add to the eDAQ
processing load and can result in a DeviceOverFlow error reset for tests running at the edge of the eDAQ processing
limit.
Minimum and maximum values are not time-stamped and the TCE polling loop results in reads that are only
approximately equally spaced in time. When using PC Card data storage, the time interval between TCE polls is
typically more erratic.
The min-max display mode can only be used with one application at a given time. If a second application (e.g., InField)
attempts to run a min-max display mode at the same time, the data presented in TCE becomes invalid.
Contiguous Block Method:
When the run-time display starts, TCE requests a contiguous block of data samples from the eDAQ for the selected
channel. The eDAQ responds to the request by returning the block of data samples. TCE displays the data in the
specified format and then requests a new block of data samples.
A contiguous block display adds to the eDAQ processing load and can lead to a DeviceOverFlow error reset for tests
running at the edge of the eDAQ processing limit.

Display Pre-Init Prerun Run-time Max Chs.
DVM yes yes no 16 or 256
Scope Plot yes yes yes 1
Spectrum Plot yes yes yes 1
Digital Readout no no yes 16
Bar Chart no no yes 16
Strip Chart no no yes 4
I2740-2.1 en 81
SoMat eDAQ
4.5.2 Common Display Options
Start Run (run-time only)
For run-time displays during a preview run, select Start Run to start a test run.
View
Select one of the two view modes available for each display.
Setup (run-time only)
Select setup to exit the current display and return to the run-time display setup window.
Units (pre-init and prerun only)
Select one of two units options available.
Quit / Off
Select Quit (run-time) or Off (pre-init and prerun) to exit the display.
View Mode Description
Scan Update data in the display as it is received.
Hold Do not update the display. For some displays, the Hold mode allows
access to certain display options.
Units Description
Signal / Volts Display the transducer in signal units (e.g., volts). This is the only
option available for uncalibrated transducers.
Engineering Display the transducer in engineering units (e.g., microstrain). This is
the default option for calibrated transducers.
SoMat eDAQ
82 I2740-2.1 en
4.5.3 DVM
The DVM (digital voltmeter) display samples and displays up to 16 or 256 transducer
signals in a digital format. The DVM is available pre-initialization and as a prerun
option. TCE presents the DVM display window differently for a single channel and a
group of channels.
Figure 4-2: A TCE DVM signal display for a single channel.
Figure 4-3: A TCE DVM signal display for a group of channels.
Rate
Adjust the rate scroll bar to change the rate at which TCE updates the display.
NOTE
A DVM for a single digital input channel offers the option to read bits. When using this
option, the eDAQ reads the current state of the digital input line and TCE displays a
check when the line is high (i.e., logical TRUE) or no check when the line is low (i.e.,
logical FALSE).

I2740-2.1 en 83
SoMat eDAQ
4.5.4 Scope Plot
The scope plot display is similar to that of an analog oscilloscope except that the
display is not updated until the eDAQ acquires all of the data samples and transfers
them to TCE which creates a delay in the data presentation. The scope plot is available
for a single channel at pre-initialization, as a prerun option and as a run-time display.
For more information on scope plot display preferences, see Scope and Spectrum
Display on page 58.
Figure 4-4: A TCE scope plot as a run-time display.
Samples
Select the desired number of samples to display on each scope scan.
Auto Scale
Select the auto scale option to switch to automatic y-axis scaling mode which sets the
y-axis limits to the maximum and minimum values in the data set for each scope scan.
Grid Lines
Select the grid lines option to add grid lines to the scope display. The grid lines divide
each axis into ten equal parts. If using the auto scale option, TCE only displays the
x-axis grid lines.
SoMat eDAQ
84 I2740-2.1 en
4.5.5 Spectrum Plot
The spectrum plot display shows the frequency content of the signal. TCE scales the
x-axis from 0 Hz to the Nyquist frequency (i.e., half the sample rate) and the log y-axis
to cover up to six decades. The data points are the approximate sine amplitude of the
signal components at each frequency. The data point at 0 Hz in the DC level of the
signal. The spectrum plot is available for a single channel at pre-initialization, as a
prerun option and as a run-time display. For more information on spectrum plot display
preferences, see Scope and Spectrum Display on page 58.
Figure 4-5: A TCE spectrum plot as a prerun option display.
Samples
Select the desired number of samples used in the FFT algorithm to generate the
frequency spectrum.
Grid Lines
Select the grid lines option to add grid lines to the spectrum display. The grid lines
divide the x-axis into 10 equal parts and the y-axis on a log scale in decades.
Half Life
Select the desired half life value. The spectrum half life specifies the amount of old data
to combine with the newly acquired data. For example, if the half life is one, the
contribution of the old spectrum data is half of the contribution from the new data. If
the half life is ten, it takes ten new frames of data before the old data is at half its
influence. The default value is zero which results in no data accumulation. For
situations with stable signal content, a larger half life produces a display with fewer
fluctuations and a better representation of signal content.
I2740-2.1 en 85
SoMat eDAQ
4.5.6 Digital Readout
The digital readout display continuously shows two sets of minimum and maximum
readings in a digital format for up to 16 channels. The last reading min and max
columns display the minimum and maximum values from the latest reading. The since
reset min and max columns show the overall minimum and maximum values since the
start of the display or the last reset. The digital readout is available as a run-time
display only.
Figure 4-6: A TCE digital readout run-time display.
Reset
Click the Reset button or use the ALT+R keyboard shortcut to reset the tracking and
display of the overall minimum and maximum values.
SoMat eDAQ
86 I2740-2.1 en
4.5.7 Bar Chart
The bar chart display uses solid horizontal bars to continuously show the most recent
minimum and maximum data values for up to 16 channels. TCE uses an arrow head
to point to the bar when the bar is very thin. The chart also uses cross-hatched
horizontal bars to show the overall minimum and maximum values since the start of
the display or the last reset. The FS min and max columns display the full-scale values
defined for the channel. The bar chart is available as a run-time display only. For more
information on bar chart display preferences, see Run-Time Display on page 59.
Figure 4-7: A TCE bar chart run-time display.
Reset
Click the Reset button or use the ALT+R keyboard shortcut to reset the tracking and
display of the overall minimum and maximum values.
I2740-2.1 en 87
SoMat eDAQ
4.5.8 Strip Chart
The strip chart display shows the minimum and maximum readings for up to four
channels as a sequence of solid vertical bars along the x-axis. The chart displays up
to 400 most recent min-max readings. The strip chart is available as a run-time display
only. For more information on strip chart display preferences, see Run-Time Display
on page 59.
NOTE
The x-axis of the strip chart is not a linear time base. The display update period is
determined by the processing time required plus a built-in delay. Actions such as
changing the plot mode or placing the display on hold significantly affects the update
period. In steady-state operation, the x-axis is usually a good approximation of a linear
time base.

Figure 4-8: A TCE strip chart run-time display.
Plot Mode
Select one of three strip chart plotting modes.
SoMat eDAQ
88 I2740-2.1 en
Show Grids
Select the show grids option to show the grid lines on the display.
4.6 Uploading Test Data
Uploading test data transfers all or selected test runs resident in the data file stored in
the eDAQ to a user-specified PC disk file. Upload complete SIE or SIF files after
stopping a test run. When using SIE data, partial files are available for upload during
a test run.
After transferring the file to the support PC, use InField or other data analysis software
to view and analyze the test data.
4.6.1 Uploading SIE Data Files
From the eDAQ
To upload SIE data from the RAM disk or PC Card storage in the eDAQ, select Upload
Test Data from the Test Control menu or toolbar. Upload SIE test data at any time,
including during a test run when partial test data is available. Use some caution when
uploading during a test run as the upload task consumes some processing time and
can result in a DeviceOverFlow error reset if the eDAQ cannot keep up with the
processing requirements.
From a PC Card
If transferring data from a PC Card inserted in the support PC, simply copy the SIE file
from the PC Card to a PC directory.
4.6.2 Uploading SIF Data Files
From the eDAQ
To upload SIF data from the RAM disk or PC Card storage in the eDAQ, select Upload
Test Data from the Test Control menu or toolbar. If using RAM disk storage, TCE
uploads the SIF file directly to the PC file. If the PC Card data storage option is in use,
the eDAQ first consolidates the SIF data file from the RAM disk resident component
file and the set of PC Card resident component files. A test run cannot be in progress
to upload a SIF data file.
Plot Mode Description
Normal When the plot reaches the end of the x-axis, TCE erases the display
and draws the next vertical bar at the beginning of the x-axis.
Scroll The vertical bars continuously scroll from left to right after the plot
reaches the end of the x-axis for the first time. The latest min and max
values are always at the end of the x-axis.
Mixed When the plot reaches the end of the x-axis, TCE moves the last half
of the display to the first half and resumes plotting from the middle of
the display.
I2740-2.1 en 89
SoMat eDAQ
Upload SIF data after a test run or after ending a test. The upload option becomes
unavailable as soon as a new test is initialized, since the eDAQ deletes the RAM disk
SIF component file upon initialization.
NOTE
If there is a communications failure between the PC and the eDAQ during an upload
of the files on the PC Card, TCE enters a loop of making repeated attempts to
re-establish communications so that the upload process can recover and continue.
This recovery scheme handles most types of communication failures such as power
lost to the eDAQ temporarily or Ethernet connections broken temporarily. If necessary,
abort the communications loop using the Abort option in the upload progress window.

NOTE
To increase data analysis performance, chain frame demultiplexing to the upload
process using TCE General Preferences.

From a PC Card
If transferring SIF component files from a PC Card inserted in the support PC, first
copy the SIC files from the PC Card to a PC directory. Then select Consolidate SIC
Files from the File menu. The consolidate SIC files option generates a complete SIF
file from the component files. TCE performs a number of validity checks on the SIC file
set during the SIF file generation process.
NOTE
To increase data analysis performance, chain frame demultiplexing to the consolidate
process using TCE General Preferences.

4.6.3 Extracting Data from SIE or SIF Files
SIE an SIF files contain more information than what is available when viewing
uploaded data. To access this information, select Open SIE or SIF File from the File
menu.
NOTE
When opening a SIF file, TCE checks the file for any frame multiplexed data records.
If they are present, TCE presents the option to demultiplex all frame multiplexed data
records. Analysis routines that run on a channel by channel basis typically execute
significantly faster using fully demultiplexed data records.

Select one of the following options to access additional test and eDAQ information.
SoMat eDAQ
90 I2740-2.1 en
Keyword Extraction Options
The keyword extraction options provide the opportunity to extract some of the global
keyword data sets that are embedded in the SIE or SIF data file. To access an
available option, select the corresponding radio button and click OK.
Message Channel Extraction Options
The message channel extraction options provide the opportunity to extract message
channel data sets that are resident in the SIE or SIF file to a text file on the support PC.
TCE presents a list box containing all of the message channels in the data file. Select
one or more of the message channels and then save the message channel data sets
to a PC file.
Keyword Data Set Description
TCE Setup File Extract the TCE setup file to a PC file.
FCS Log File Extract the eDAQ log file to a PC file.
Test Run Descriptions Extract the TCE test run descriptions to a PC file.
State Mapper File Extract the specified (by index) State Mapper ASCII definition
file to a PC file. The file index starts from 1. TCE appends the
original source ASCII file name to the extracted file. Delete this
file name from the extracted file to reuse the ASCII file in a
State Mapper computed channel (see State Mapper on
page 152).
Reference Shunt Check Info Extract the TCE reference shunt check information and display
it in the same reference shunt checks TCE dialog window used
during active test control. For more information, see
Reference Shunt Checks on page 76.
Run Rezero File Extract the run number indexed TCE transducer rezero ASCII
file to a PC file. The run number index starts from 1. The first
line of the file specifies the run number. The following lines
contain the transducer channel ID and the zero offset value in
engineering units. There is one line for every transducer
channel that can be rezeroed. The offset value is the amount
the transducer has been rezero offset since the test was first
initialized. For more information, see Rezero Display on
page 76.
Power Micro Run Status Extract all of the power micro parameters to a PC file. The
eDAQ stores the power micro parameters just before each test
run starts and includes information such as battery change
level and battery temperature. TCE also records the date and
time of the start of each test run.
I2740-2.1 en 91
SoMat eDAQ
Example PC Message Channel Files
ASCII Message Channel:
# msg_ascii@simmsg_asc.RN_1 (Sim Msg simmsg_asc)
RX 10.0000000: 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57
58 59 5A 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 (and so on...)
RX 20.0000000: 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57
58 59 5A 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 (and so on...)
Binary Message Channel:
# msg_bin@simmsg_bin.RN_1 (Sim Msg simmsg_bin)
RX 4.0000000: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16
17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B (and so on )
RX 8.0000000: 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16
17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B (and so on )

Generate Quickview Log File (SIF only)
The generate quickview log file option parses the SIF file channel list and generates
an ASCII log file that summarizes the channel list with presentation of some of the
channel header information combined with a small amount of the actual data for each
channel. This option is provided primarily for troubleshooting corrupt SIF data files.
4.7 Using Remote Control Operation
Start and stop test runs remotely using the remote control operational mode. The
remote control mode uses digital I/O lines for control inputs and status outputs. The
eDAQ uses the ECPU layer digital lines. Use one digital input line to control test run
starts and stops and up to four digital output lines for status indications. Configure the
digital input and output line assignments in the TCE Remote Control Preferences
dialog.
The remote control mode is enabled at test initialization and remains in effect until the
test ends, unless manually suspended. When the remote control mode is active, many
of the test control tasks are disabled.
The Remote Control Setup preferences configure the eDAQ for remote control of test
runs using digital input and output lines. For more information or remote control
preferences, see Remote Test Run Control on page 57.
SoMat eDAQ
92 I2740-2.1 en
4.8 Networking eDAQ Systems
Networking allows multiple eDAQ systems to acquire data synchronously using a
single master sample rate (MSR) clock source. TCE supports defining the test setup
configurations for networked systems in a single test setup file and coordinates most
test control tasks for the network. For information on setting up the networked
systems, see Networking eDAQ Systems on page 41.
NOTE
When an eDAQ is configured as either a master or a slave and a power failure or an
error reset occurs, the eDAQ does not attempt to start a new test run.

The first step is to define the set of eDAQ systems used in the test in the network setup
window. The networked nodes can consist of any combination of eDAQ and eDAQlite
systems. Configure one node as the master or the GPS master and the rest of the
nodes as slaves. The choice of which system is the master is largely arbitrary.
NOTE
All nodes in a network configuration must have the same master sample rate value.

Proceed to define the transducer channels, computed channels, and DataModes for
the test in the same manner as for a single eDAQ. Multiple channel interactive setup
tasks such as the group DVM display and parallel transducer calibrations require that
the channel set reside on a individual network node. However, most non-interactive
features (e.g., group edits and group deletions) are supported across network nodes.
With the test setup definition completed and all transducer channels calibrated,
initialize and run the test in the same manner as for a single eDAQ test. TCE
coordinates all interaction between network nodes during initializations and test runs.
NOTE
Run-time displays can only display channels from one eDAQ at a time.

While largely transparent, the details of starting or previewing and stopping test runs
are discussed briefly below. TCE first prepares each slave eDAQ for a test run start or
preview in a serial manner. The slave then waits for the master to assert the MSR clock
source for the test run to actually begin on the slave. During this waiting period, the
green and yellow LEDs on the slave blink in unison at a fairly slow rate. At the start of
the test run or preview, the master asserts the MSR clock source which starts all test
runs or previews synchronously. To stop a test run or preview, TCE stops the test run
or preview on the master eDAQ, which results in the de-assertion of the MSR clock
source. When this occurs, each slave detects the loss of the MSR clock source and
stops the test run or preview synchronously.
I2740-2.1 en 93
SoMat eDAQ
TCE gets SIF file data from the eDAQ nodes in a serial manner. TCE appends a
qualifier string to the default PC file name to distinguish the SIF files. For example, if
the test setup file name is MyTest.tce and there are three networked nodes, the default
SIF data file names are MyTest (1 of 3).sif, MyTest (2 of 3).sif and MyTest (3 of 3).sif.
TCE applies the same default naming convention when transferring files from a PC
Card.
4.8.1 Using Remote Control with a Network
For remote control with an eDAQ network, use the remote control hardware (i.e., the
ECPU interface hardware) only on the master node. This applies to both the test run
control input and the optional test monitoring output digital lines.
NOTE
The preview run option is not supported in remote control mode.

The slave eDAQ systems automatically start a new test run immediately after test
initialization and after each test run stops, as long as the remote control is not
suspended. Because of this, be careful to not start the master until the slaves are all
running and waiting for the master to assert the MSR clock source. The green and
yellow front panel LEDs blink in unison when the slave is in this ready state. Failure to
do this prevents synchronization of the slave and master data.
The automatic test runs prevent normal actions such as removing the PC Card or
ending the test after a test run stops. To perform these actions, first suspend the
remote control and then stop the test. This should be done with the run control switch
on the master set in the off position so each slave increments the test run number and
creates a new set of DataMode channels in the SIF file. Suspend and resume the
remote control mode using the same TCE interface as a stand alone eDAQ.
NOTE
When the master eDAQ reboots after a power failure or an error reset, the system
suspends the remote control mode to prevent starting a new test run on the master. In
this scenario, stop all slave eDAQ systems with test runs still in progress and resume
remote control on the master so that all nodes start the next test run in sync.

It is advised to experiment with using remote control for an eDAQ network and become
thoroughly familiar with the details involved prior to using it in the field.
SoMat eDAQ
94 I2740-2.1 en
I2740-2.1 en 95
SoMat eDAQ
5 eDAQ Hardware
The following chapter provides details on the input and output channels and
configuration options available on each eDAQ layer and module. Access the
configuration options through the TCE hardware setup window by double clicking a
hardware entry or highlighting an entry and selecting Config.
NOTE
For information on data synchronization across channels and hardware, see Data
Synchronization on page 237.

5.1 ECPU (Base Processor)
The ECPU is the foundation of the eDAQ system. For more information on eDAQ
capabilities contained in the ECPU such as battery power, Ethernet communications
and on-board memory, see Using the eDAQ on page 25.
5.1.1 ECPU Available Inputs and Outputs
The ECPU is a multifunctional layer that supports two digital input modes, a digital
output mode and serial bus data. Both of the digital input modes as well as the output
mode can be used concurrently in a test run. An optional integral ECOM layer can be
installed allowing for three dedicated CAN network interfaces, one vehicle bus module
interface and a GPS communications port. For more information on the ECOM layer,
see ECOM (Vehicle Network Communications Layer) on page 97.
Figure 5-1: Diagram of the connectors on the back panel of an ECPU layer including the
44-pin D-Sub Digital I/O connector and the 9-pin D-Sub Comm port used for serial bus inputs.
ECPU Digital Input/Output
There are ten digital input/output lines available on the ECPU. Use TCE to configure
any line as either an input or output. The input lines can be sampled individually to
generate logical (i.e., Boolean) data streams for triggering or other logical operations.
The output lines are updated at a low rate based on the user-defined pipe frame size
and are designed to drive LED indicators, remote switches, etc. The eDAQ uses
standard TTL switching logic to determine the Boolean state of the channels. Connect
digital input and output channels to the eDAQ using the Digital I/O connector on the
rear panel of the ECPU layer.
For more information on setting up digital inputs and outputs, see Digital Input on
page 120 and Digital Output on page 185. For more information on wiring digital
inputs and outputs on the ECPU layer, see ECPU (Base Processor) on page 223.
Comm. 1 Power Digital /O
SoMat eDAQ
96 I2740-2.1 en
ECPU Pulse Counter
There are eight digital pulse counter channels available that can measure pulse width,
count pulses or used in pairs to compute the duty cycle. The eDAQ uses standard TTL
switching logic to determine the Boolean state of the channels. Connect pulse counter
channels to the eDAQ using the digital I/O connector on the rear panel of the ECPU
layer.
For more information on setting up pulse counter inputs, see Pulse Counter on
page 121.
Serial Bus
The RS232 serial port can be configured as a data input port to acquire serial data
streams from various sources. Specialized code must be written to deal with the
specifics of the particular serial data streams. Therefore, serial data sources are
supported on a custom basis for such things as serial GPS or customer specific
vehicle buses. Refer to the installation instructions in the firmware installation directory
for more information on installing custom modules. Connect serial data source to the
eDAQ using the Comm connector on the rear panel of the ECPU layer.
5.1.2 ECPU Configuration Options
The ECPU offers several configuration options through the hardware setup window.
The serial bus port appears as a separate entry in the hardware setup window and
has its own configuration options which are identical to the vehicle bus configuration
options. For more information on these options, see VBM Configuration Options on
page 111.
Pipe Frame Rate
Select the eDAQ test engine pipe frame rate. As data samples are collected from the
transducer channels, the eDAQ places them in blocks of data (i.e., data frames) and
routes (i.e., pipes) them into computed channels and DataModes. In the flow of data
from the transducer inputs through the DataModes, the data frames are referred to as
pipe frames.
The lowest pipe frame rate is considerably more efficient from a processing point of
view when there are a large number of channels defined at lower sample rates
( 500 Hz). Using the lowest pipe frame rate also modestly improves throughput
performance for most tests with sample rates below 10000 Hz. At sample rates above
10000 Hz, a higher pipe frame rate generally results in the best throughput
performance. Because TCE run-time displays run at the pipe frame rate, higher pipe
frame rates may be desired.
NOTE
Select the default preference for the pipe frame rate using the FCS Specific
preferences in TCE.

I2740-2.1 en 97
SoMat eDAQ
Enable Analog Output Inverting
Select the analog output inverting option to automatically invert the polarity of analog
outputs from EHLS, EBRG and ELLB layers with the optional analog out function. Use
this option in situations where the analog output polarity is opposite of the engineering
units scaling polarity which is common of many transducers.
NOTE
The analog output settings are stored in nonvolatile memory and cannot be modified
after test initialization.

Input/Output Configuration
Use the input/output configuration section to view or modify the current settings for
each digital line. Configure a line as an input by checking the corresponding box or as
an output by deselecting the corresponding box.
NOTE
The input/output settings are stored in nonvolatile memory and cannot be modified
after test initialization.

PC Card Options
The PC Card options section contains four button controls for performing various tasks
for the selected PC Card media.
5.2 ECOM (Vehicle Network Communications Layer)
The ECOM is a multifunctional layer that supports three dedicated CAN vehicle bus
sources, one generic vehicle bus module interface and a GPS communications port.
The ECOM layer supports up to 254 vehicle bus channels per input. The layer comes
with many predefined databases such as J1939 and OBDII. The GPS
communications port is designed to work with SoMat GPS devices.
PC Card Option Description
Status Display a short message detailing the eDAQ SIF component file
directory status of the installed PC Card.
Purge Purge the installed PC Card of all files. Note that purged files cannot
be recovered.
Test This function is no longer supported on the eDAQ.
Format Open the eDAQ web interface to format the installed PC Card.
SoMat eDAQ
98 I2740-2.1 en
Figure 5-2: Diagram of the M8 connectors for CAN, VBM and GPS connections on an
ECOM layer.
5.2.1 ECOM Available Inputs
Each vehicle bus and GPS port appears as separate hardware in the TCE hardware
setup window. For more information on vehicle bus inputs and configuration options,
see Vehicle Bus Module on page 110. For more information on the GPS modules,
see EGPS-5HZ (SoMat GPS Receiver) on page 108 or EGPS-200 (Precision GPS
Module) on page 109.
5.2.2 ECOM Configuration Options
Vehicle Bus Module Usage
The vehicle bus module usage parameter displays what type of vehicle bus module, if
any, is defined in the current hardware setup.
GPS Clock Interface
Select the GPS clock interface option to open another dialog window with the enable
GPS clock generation option. Select the GPS clock generation option to enable
GPS-based master sample rate clock generation. Only one GPS-based clock
generation source can be defined in a test setup. Define the network mode in the
network setup window to either GPS master or GPS stand alone.
5.3 EDIO (Digital Input/Output Layer)
The EDIO is an extremely versatile layer that supports digital inputs and outputs, pulse
counters, two vehicle bus module interfaces and optional GPS receiver.
Figure 5-3: Diagram of the M8 connectors on an EDIO layer.
5.3.1 EDIO Available Inputs and Outputs
The digital I/O channels are grouped into three functionally identical banks (A, B and
C). Each bank contains three connectors of four digital I/O channels (i.e., bits). The
eight channels on connectors |1-4| and |4-8| are individually configurable to be either
inputs or outputs. The four channels on connector |9-12| are dedicated wide-range
input channels. Each connector also provides two pulse counter channels for a total of
six pulse counter channels per bank.
One layer also supports up to two independent vehicle bus module interfaces and an
optional GPS receiver, which appear as separate entries in the TCE hardware setup
window. For more information on the GPS modules, see EGPS-5HZ (SoMat GPS
1 CAN
GPS
2
VBM
3
1-4
0-45v
9-12
5-8 1-4
0-45v
9-12
5-8 1-4
0-45v
9-12
5-8
A B C
I2740-2.1 en 99
SoMat eDAQ
Receiver) on page 108 or EGPS-200 (Precision GPS Module) on page 109. For
more information on setting up vehicle bus modules, see Vehicle Bus Module on
page 110.
EDIO Digital Input/Output
There are 12 digital input/output lines available for each bank on the EDIO. Use TCE
to configure the lines on the |1-4| and |5-8| connectors as either inputs or outputs. The
input lines can be sampled individually to generate logical (i.e., Boolean) data streams
for triggering or other logical operations.
Use the EDIO bank configuration options to program the input threshold mode and
limits for determining the Boolean state of the input channels. Connect channels to the
EDIO using the numbered M8 connectors on the front panel of the layer.
The output lines are updated at a low rate based on the user-defined pipe frame size
and are designed to drive LED indicators, remote switches, etc. Use the ELDIO
configuration options to set the power output at either nominal five volts or nominal 12
volts for each bank.
For more information on setting up digital inputs and outputs, see Digital Input on
page 120 and Digital Output on page 185. For more information on wiring digital
inputs and outputs on the EDIO layer, see EDIO (Digital I/O Layer) on page 224.
EDIO Pulse Counter
The pulse counter channels share the same input lines as the digital input/output
channels. Two pulse counter channels are provided on each connector (|1-4|, |5-8| and
|9-12|). Pulse counter channels can measure pulse width, count pulses or used in
pairs as quadrature encoder inputs typically used to track angular or linear position.
Connect pulse counter channels to the EDIO using the numbered M8 connectors on
the front panel.
For more information on setting up pulse counter inputs, see Pulse Counter on
page 121.
NOTE
Input bits (i.e., channels) used for pulse counters can simultaneously be used for
digital input channels.

Limits on EDIO Input Voltages
The four channels on connector |9-12| on each bank of the EDIO are wide range inputs that can accept steady state voltages
in the range of 45 volts. These channels can also tolerate short duration spikes up to +100 volts (as can be encountered
using inductive pickup devices).
The eight channels on connectors |1-4| and |5-8| on each bank of the EDIO are configurable as either inputs or outputs and
can accept steady state voltages in the range of -0.2 to +45 volts. These channels can also tolerate short duration spikes up
to +100 volts. In general, it is advised that these channels be used only with positive voltage input sources.
Exceeding the input ranges described above can result in component damage, requiring factory repair. Layer damage caused
by exceeding input voltage limits is not covered by HBM warranty.

SoMat eDAQ
100 I2740-2.1 en
5.3.2 EDIO Configuration Options
Each bank on the EDIO layer is independently configurable. Click on the desired bank
button in the configuration dialog for the specific parameters (indicated with bank in
parentheses) available for each bank. The EDIO layer also has several configuration
options for the Megadac interface (indicated with Megadac in parentheses).
Vehicle Module Usage (bank)
The vehicle bus module usage parameter displays what type of vehicle bus module, if
any, is defined in the current hardware setup.
Input/Output Configuration (bank)
Configure the eight channels on connectors |1-4| and |5-8| as either inputs or outputs.
Configure a line as an input by checking the corresponding box or as an output by
deselecting the corresponding box. The channels on connector |9-12| are input only.
Input Threshold Mode (bank)
Select the desired mode for defining the input threshold limits. Selecting either the TTL
or zero crossing options results TCE assigning specific upper and lower limits.
Selecting the user defined option allows for a user-configurable upper limit.
Input Threshold Limits (bank)
When using the user-defined threshold mode, specify the upper input threshold limit
to determine when an input channel switches from a logical value of TRUE to a logical
value of FALSE and vice-versa. The difference between the upper and lower limits is
fixed at nominal one volt. The maximum upper limit is 4.8 volts and the minimum upper
limit is one millivolt.
The input threshold value assigned for any given bank applies to all input bits for that
bank. Individual input bits in the same bank cannot have different input threshold
values.
NOTE
If a vehicle bus module is connected, the eDAQ configures bank A with a 2500-millivolt
upper input threshold.

Power Voltage (bank)
Select either the nominal 5-volt or nominal 12-volt option as the power output for digital
outputs. Either voltage option can source up to one amp.
NOTE
If a vehicle bus module is connected, the eDAQ configures bank A with the 12-volt
output power option.
I2740-2.1 en 101
SoMat eDAQ

NOTE
The 12-volt option operates correctly only if the input power to the eDAQ is about
14-15 volts. Otherwise, the output is less than 12 volts.

GPS Clock Interface
Select the GPS clock interface option to open another dialog window with the enable
GPS clock generation option. Select the GPS clock generation option to enable
GPS-based master sample rate clock generation. Only one GPS-based clock
generation source can be defined in a test setup. Define the network mode in the
network setup window to either GPS master or GPS stand alone. For more information
on using GPS clock generation for wireless networking, see Wireless Network on
page 42.
Enable Clock Generation (Megadac)
Select the Megadac clock generation option to enable Megadac clock generation.
Only one Megadac clock generation source can be defined in the test setup.
Sync Delay Counts (Megadac)
The sync delay counts parameter controls the time period that the clock generation is
delayed relative to the time that the eDAQ turns on the source clock that drives data
collection on both the eDAQ and the Megadac.
For a MSR of 100 kHz, the eDAQ data collection start 1.00 seconds after the MSR
clock is turned back on to start a synchronized test run. This 100 kHz clock is down
sampled by ten to generate a 10000 Hz clock source for the Megadac interface
board. Therefore, if the Megadac starts recording on the first clock pulse issued after
switching to record mode, the sync delay counts should be set at the default value of
10000.
For a MSR of 98.304 kHz, the eDAQ data collection starts 1.25 seconds after the MSR
clock is turned back on to start a synchronized test run. This 98.304 kHz clock is down
sampled by 12 to generate a 8192 Hz clock source for the Megadac interface board.
Therefore, if the Megadac starts recording on the first clock pulse issued after
switching to record mode, the sync delay counts should be set at the default value of
8192.
NOTE
In general, the Megadac does not appear to start data collection on the first clock
pulse. For accurate synchronization of eDAQ and Megadac data, it is advised to
experimentally determine the desired sync delay counts for the particular test
configuration of interest.

Down Sample Factor (Megadac)
Specify the factor by which the eDAQ down samples the MSR source clock to
generate the desired Megadac sample rate. The down sample factor can be any
value in the range of 2 to 65535.
SoMat eDAQ
102 I2740-2.1 en
5.4 EBRG (Bridge Layer)
The EBRG offers 16 simultaneously sampled, low-level, differential analog inputs
through independent connectors. The EBRG layer works with both amplified and
unamplified transducers including strain gauges, accelerometers, pressure
transducers, load cells and other general analog signals. Connect transducers to the
EBRG individually using the M8 connectors located on the front panel.
Figure 5-4: Diagram of the M8 connectors on an EBRG layer.
Each independent channel contains programmable excitation, an eight-pole
Butterworth analog guard filter, a 16-bit A/D converter, software selectable digital
filtering and output sample rate options of up to 100 kHz.
The EBRG layer supports full- and half-bridge types with a resistance from 100 to
10000 ohms and quarter-bridges with a resistance of either 120 or 350 ohms. All
bridge configurations are accomplished using programmable switches (i.e., there are
no jumpers), however, the quarter-bridge choice of 120- or 350-ohm completion
resistor is a factory installed option. A set of internal shunt resistors with selectable
shunt direction is available for calibration purposes.
For more information on setting up EBRG input channels, see Bridge on page 123.
For information on wiring EBRG inputs, see EBRG (Bridge Layer) on page 228.
MSBRG.01 Limitations on the Use of Full Bridges
The MSBRG.01 version of the EBRG layer cannot provide sufficient current to drive 16 full 120-ohm bridges with the eDAQ
power source below 15 volts or to drive 16 full 350-ohm bridges with the eDAQ power source below 11 volts. A terse summary
of currently known limitations based on limited testing is below.
16 full 120-ohm bridges OK at 15.0-volt eDAQ power
15 full 120-ohm bridges OK at 13.5-volt eDAQ power
13 full 120-ohm bridges OK at 10.0-volt eDAQ power
15 full 350-ohm bridges OK at 10.0-volt eDAQ power
16 full 350-ohm bridges OK at 11.0-volt eDAQ power

Analog Output
The EBRG is available with an optional analog output function to provide high level
analog output signal for each channel. Outputs are filtered analog output signals that
can be used in the creation of time-domain lab durability tests. Each output channel is
associated with the corresponding (like-numbered) input channel on the EBRG board.
Connect the analog outputs to the EBRG through the Analog Output connector on the
back panel shown in the diagram below.
B
R
G 2
1 3
4
5
6
7
8
9
10
11
12
13
14
15
16
I2740-2.1 en 103
SoMat eDAQ
Figure 5-5: Diagram showing the analog out connector on the back panel of an EBRG layer.
The outputs are generated from a D/A converter implemented as a unity gain follower
to the A/D converter. The eDAQ uses the non-inverting unity gain follower by default.
Select the analog output inverting option in the ECPU hardware configuration to use
the inverting unity gain follower.
NOTE
The EBRG uses a nominal 2-volt A/D converter. However, do not assume that the
user-defined full-scale values are even approximately equivalent to 2 volts for any
particular channel. This is primarily because TCE automatically provides a minimum
overrange protection of 1% and the eDAQ can set gains only at certain discrete values
resulting in actual overrange protection that is sometimes significantly larger than 1%.

TCE provides the option to generate an AOM calibration file which is an ASCII file
containing all of the information required to scale the analog output signal voltages to
equivalent engineering values. The file also includes SIE or SIF file analog output
scale and offset keywords for each channel stored in a Time History DataMode. Select
Save AOM File from the Test Control menu to generate the file. For more information
on the AOM file, see AOM Calibration File on page 73.
5.5 EHLS (High Level Analog Layer)
The EHLS offers 16 simultaneously sampled, high-level, differential analog inputs
through independent connectors. The EHLS layer supports a wide variety of inputs
including thermocouples, strain gages, accelerometers, microphones and amplified
and unamplified transducers. Single channel IEPE (Integral Electronics Piezoelectric)
adapters and a variety of SMART modules are also available. Connect transducers to
the EHLS individually using the M8 connectors located on the front panel.
Figure 5-6: Diagram of the M8 connectors on an EHLS layer.
Each independent channel contains programmable transducer power, an eight-pole
Butterworth analog guard filter, a 16-bit A/D converter, software selectable digital
filtering and output sample rate options of up to 100 kHz. The EHLS also provides 400
milliwatts of transducer power supply with an adjustable supply voltage of 3-28 volts
for every channel. Use the transducer power supplies in parallel for larger loads.
AnaIog Out
H
L
S 2
1 3
4
5
6
7
8
9
10
11
12
13
14
15
16
SoMat eDAQ
104 I2740-2.1 en
For more information on setting up EHLS input channels, see Simultaneous High
Level on page 126. For information on wiring EHLS inputs, see EHLS (High Level
Analog Layer) on page 226.
NOTE
The analog guard filters on the EHLS channels result in some gain amplification for
high frequency inputs. For more information, refer to the EHLS data sheet.

Analog Output
The EHLS is available with an optional analog output function to provide high level
analog output signal for each channel. Outputs are filtered analog output signals that
can be used in the creation of time-domain lab durability tests. Each output channel is
associated with the corresponding (like-numbered) input channel on the EHLS board.
Connect the analog outputs to the EHLS through the Analog Output connector on the
back panel shown in the diagram below.
Figure 5-7: Diagram showing the analog out connector on the back panel of an EHLS layer.
The outputs are generated from a D/A converter implemented as a unity gain follower
to the A/D converter. The eDAQ uses the non-inverting unity gain follower by default.
Select the analog output inverting option in the ECPU hardware configuration to use
the inverting unity gain follower.
NOTE
The EHLS uses a nominal 2-volt A/D converter. However, do not assume that the
user-defined full-scale values are even approximately equivalent to 2 volts for any
particular channel. This is primarily because TCE automatically provides a minimum
overrange protection of 1% and the eDAQ can set gains only at certain discrete values
resulting in actual overrange protection that is sometimes significantly larger than 1%.

TCE provides the option to generate an AOM calibration file which is an ASCII file
containing all of the information required to scale the analog output signal voltages to
equivalent engineering values. The file also includes SIE or SIF file analog output
scale and offset keywords for each channel stored in a Time History DataMode. Select
Save AOM File from the Test Control menu to generate the file. For more information
on the AOM file, see AOM Calibration File on page 73.
5.6 ENTB (Non-Isolated Thermocouple Layer)
The ENTB provides non-isolated thermocouple inputs in two banks (A and B) of 16
channels. The ENTB supports the four most common thermocouple types: J, K, T and
E. The user-specified thermocouple type for each channel is independent of the other
AnaIog Out
I2740-2.1 en 105
SoMat eDAQ
channels. The 16 channels of each bank share a common cold junction resulting in
high channel-to-channel accuracy, which is particularly valuable when measuring
thermal gradients.
Figure 5-8: Diagram of the 37-pin D-Sub connectors on an ENTB layer.
Each channel uses a notched filter processor that generates about seven samples per
second. Since these channels are not isolated from each other, they can only be used
in applications where the individual thermocouples are electrically isolated from each
other. A cold junction box is required for each bank and is connected to the eDAQ with
the cables provided using the connectors labeled A01-A16 or B01-B16 located on
the front panel. Each thermocouple is connected to the miniature barrier strip type
paired inputs in the junction box.
NOTE
Thermocouple leads should not exceed 30 meters in length from connector to tip.

The eDAQ uses the industry standard software compensation algorithm to generate
the temperature data samples. The eDAQ first measures the cold-junction
compensation (CJC) temperature and converts it to the equivalent microvolt value
using a high-resolution lookup table. The eDAQ then subtracts the CJC equivalent
microvolt value from the thermocouples output microvolt value. The temperature is
found using another high-resolution lookup table. The lookups are based on the
ITS-90 Thermocouple Direct and Inverse Polynomials.
For more information on setting up ENTB input channels, see Thermocouple on
page 134.
Application Note on Measuring Differential Temperatures
To measure differential temperatures using the ENTB layer, select two or more adjacent channels on the same bank. Use
matched thermocouples for optimum differential accuracy.
Due to instrumentation noise, it is recommended that the maximum sample rate (e.g., 5 Hz for the 100 KHz MSR option) and
a Smoothing Filter computed channel be used for each input channel. Using a five- or seven-tap Smoothing Filter typically
reduces the instrumentation noise to below 0.2 C peak to peak (for all thermocouple types). Using more taps can further
reduce the noise.
To generate the differential temperature, use a simple Desk Calculator computed channel. Use a Down Sampler computed
channel to achieve the desired data storage rate.

A01-A16 B01-B16
TCB
SoMat eDAQ
106 I2740-2.1 en
5.7 EITB (Isolated Thermocouple Layer)
The EITB provides eight channels of isolated thermocouple signal conditioning. The
EITB is factory-configured for J, T, E or K type thermocouples and is operational over
the full range of the thermocouple. Each channel has individual cold junction
compensation and a notched filter processor that generates about seven samples per
second. Each channel is also isolated from the other channels to 500 volts, which
allows the thermocouples to be attached to structures that have large differences in
ground potential. The thermocouples are connected to the eDAQ using the standard
Omega miniature thermocouple connectors located on the front panel.
NOTE
Thermocouple leads should not exceed 30 meters in length from connector to tip.

Figure 5-9: Diagram of the thermocouple connectors on an EITB layer configured for K-type
thermocouples.
The eDAQ uses the industry standard software compensation algorithm to generate
the temperature data samples. The eDAQ first measures the cold-junction
compensation (CJC) temperature and converts it to the equivalent microvolt value
using a high-resolution lookup table. The eDAQ then subtracts the CJC equivalent
microvolt value from the thermocouples output microvolt value. The temperature is
found using another high-resolution lookup table. The lookups are based on the
ITS-90 Thermocouple Direct and Inverse Polynomials.
For more information on setting up EITB input channels, see Isolated Thermocouple
on page 135.
5.8 EHLB (High Level Layer)
NOTE
The EHLB is no longer in production.

The EHLB provides 16 single-ended analog channels for high level transducer inputs
with full-scale input ranges independently set to either 10 or 20 volts. The 16
channels are multiplexed into a 16-bit A/D converter with a channel to channel skew
of approximately 25 microseconds. Connect transducers to the eDAQ using the
connector labeled HiLev (1-16)/Veh. Bus located on the front panel.
The EHLB layer also supports an optional vehicle bus sub-layer. For more information
on vehicle bus configuration options, see VBM Configuration Options on page 111.
CH 1-4 CH 5-8
K K K K K K K K
I2740-2.1 en 107
SoMat eDAQ
For more information on setting up EHLB input channels, see High Level on
page 128. For information on wiring EHLB inputs, see EHLB (High Level Layer) on
page 230.
5.9 ELLB (Low Level Layer)
NOTE
The ELLB is no longer in production.

The ELLB provides eight analog channels of low level signal conditioning and supports
a differential amplifier mode as well as full, half, and quarter bridge modes (selectable
on a channel by channel basis). Connect transducers to the eDAQ using the
connectors labeled LoLev (1-4) and LoLev (5-8) located on the front panel. A
four-channel ICP accelerometer adapter module is also available for use with a single
bank of low level channels. A maximum of 2 modules can be used with each ELLB.
The ELLB layer conditions each of the eight input signals by means of programmable
excitation circuitry, a five-pole Butterworth analog guard filter, programmable amplifier
gain and offset, 16-bit A/D converter sampling at 10000 Hz (or 8192 Hz) with
simultaneous sampling for all eight channels, programmable digital filters and the
output sample rate achieved by means of multiple stages of combined down sampling
and digital filtering.
The ELLB layer supports full and half bridge types with a resistance from 100 to 10000
ohms and quarter bridges with a resistance of either 120, 350, or 1000 ohms. All
bridge configurations are accomplished using programmable switches (i.e., there are
no jumpers), however, the quarter bridge choice of 120-, 350-, or 1000-ohm
completion resistor is a factory installed option. A set of internal shunt resistors with
selectable shunt direction is available for calibration purposes.
For more information on setting up ELLB input channels, see Low Level on
page 128. For information on wiring ELLB inputs, see ELLB (Low Level Layer) on
page 231.
NOTE
The input impedance of the low level input channels is dependent on the excitation
voltage. Signals with voltages greater than the excitation amplitude can be dragged
down due to very low input impedance (on the order of 100 ohms). For example, if the
excitation is set to the 10-volt range option (i.e., bipolar 5 volt excitation), then any
signal voltages beyond approximately 6.0 volts are dragged down significantly. Since
the excitation is set to 0 range on power up (or reset), then any signal voltages beyond
approximately 1.0 volts are dragged down significantly until the user-specified
excitation is applied.

SoMat eDAQ
108 I2740-2.1 en
Analog Output
The ELLB is available with an optional analog output function to provide high level
analog output signal for each channel. Outputs are filtered analog output signals that
can be used in the creation of time-domain lab durability tests. Each output channel is
associated with the corresponding (like-numbered) input channel on the ELLB board.
The outputs are generated from a D/A converter implemented as a unity gain follower
just before the A/D converter. The eDAQ uses the non-inverting unity gain follower by
default. Select the analog output inverting option in the ECPU hardware configuration
to use the inverting unity gain follower.
NOTE
The ELLB uses a nominal 10-volt A/D converter. However, do not assume that the
user-defined full-scale values are even approximately equivalent to 10 volts for any
particular channel. This is primarily because TCE automatically provides a minimum
overrange protection of 1% and the eDAQ can set gains only at certain discrete values
resulting in actual overrange protection that is sometimes significantly larger than 1%.

TCE provides the option to generate an AOM calibration file which is an ASCII file
containing all of the information required to scale the analog output signal voltages to
equivalent engineering values. The file also includes SIE or SIF file analog output
scale and offset keywords for each channel stored in a Time History DataMode. Select
Save AOM File from the Test Control menu to generate the file. For more information
on the AOM file, see AOM Calibration File on page 73.
5.10 EGPS-5HZ (SoMat GPS Receiver)
The EGPS-5HZ is a commercial WAAS-enabled GPS receiver with a fixed 5 Hz
navigational update rate. The receiver continuously tracks and uses up to 12 satellites
to compute and update position. The receiver has a serial interface connection routed
to the EDIO or ELCOM.
Another feature available with the EGPS-5HZ receiver is GPS-based master sample
rate clock generation. Use the configuration options of the parent layer (EDIO or
ECOM) to enable GPS clock generation.
Notes on the Old GPS Module
The old GPS module has an antenna connection routed to the EDIO rear panel. This GPS module is a low-power
consumption 12-channel GPS receiver that is WAAS-enabled. Navigational updates are fixed at a rate of 1 Hz.
At highway driving speeds, this older GPS module does not always maintain sufficient communications lock on the GPS
satellites to consistently acquire GPS updates at a reasonable rate. This results in the GPS data going stale with invalid data
fills brought into play. This appears to happen more frequently at highway speeds, but has been observed in other test
scenarios. Furthermore, it can sometimes take a very long time for the GPS module to re-acquire satellite communications
lock (several minutes in some cases).

I2740-2.1 en 109
SoMat eDAQ
5.10.1 Available Inputs
GPS
Available GPS channels include latitude, longitude, altitude, speed (m/s, mph or
knots), heading, year, month, day, hour, minute, second, nanosecond and number of
satellites. For more information on setting up GPS inputs, see Bus-Oriented Input
Channels on page 135.
NOTE
Position accuracy varies with several factors including, but not limited to, GPS receiver
configuration, location (geographic latitude, as it influences HDOP, and surrounding
objects possibly blocking reception or causing multi-path reception), satellite
constellation status and ionosphere conditions.

NOTE
There is an anomaly in the acquisition or processing of the GPS time that results in
some small discontinuities in the absolute GPS time data. This occurs when the nsec
channel rolls over and persists for about 20% of the time until the nsec channel rolls
over again (which takes about 4 hours). As such, there is at least one second of
uncertainty in the GPS time data stored in the data file whether or not the nsec
channel is stored.

5.10.2 Configuration Options
Hardware Interface
Select the desired GPS hardware interface.
Databases
Select one or more database files from the presented list. The selected databases
determine the channel types available when adding a GPS channel to the test setup.
5.11 EGPS-200 (Precision GPS Module)
The EGPS-200 module, part of the SoMat Sensors product line, is a GPS receiver
designed for non-contact speed measurements in vehicle testing applications such as
braking and acceleration. The EGPS-200 module includes a 200 Hz combined speed
channel that combines three-axis acceleration and raw GPS speed readings for a
high-accuracy and fast updating output. The module includes an SMA connection for
use with an external GPS antenna and a TNC connection that allows for external
triggering. The receiver has a serial interface connection routed to the EDIO or
ELCOM.
Another feature available with the EGPS-200 receiver is GPS-based master sample
rate clock generation. Use the configuration options of the parent layer (EDIO or
ECOM) to enable GPS clock generation.
SoMat eDAQ
110 I2740-2.1 en
5.11.1 Available Inputs
GPS
The EGPS-200 is available in a base or premium model. The base model provides 18
possible channels including high-accuracy 200 Hz velocity, 20 Hz GPS speed and
absolute position and three-axis instantaneous acceleration. The premium model
provides all the channels of the base model plus IMU (inertial measurement unit) and
RTK (real time kinematic) measurement options. The IMU option allows for extremely
high-accuracy three-axis accelerations and rotational rates. The RTK option uses the
readings from two GPS antennas to output high-accuracy yaw, pitch and slip angle
measurements at 20 Hz. The EGPS-200 directly measures the yaw and pitch at any
time, while the slip angle calculations require the vehicle to be moving. For more
information on setting up GPS inputs, see Bus-Oriented Input Channels on
page 135.
NOTE
Position accuracy varies with several factors including, but not limited to, GPS receiver
configuration, location (geographic latitude, as it influences HDOP, and surrounding
objects possibly blocking reception or causing multi-path reception), satellite
constellation status and ionosphere conditions.

NOTE
There is an anomaly in the acquisition or processing of the GPS time that results in
some small discontinuities in the absolute GPS time data. This occurs when the nsec
channel rolls over and persists for about 20% of the time until the nsec channel rolls
over again (which takes about 4 hours). As such, there is at least one second of
uncertainty in the GPS time data stored in the data file whether or not the nsec
channel is stored.

5.11.2 Configuration Options
Hardware Interface
Select the desired GPS hardware interface.
Databases
Select one or more database files from the presented list. The selected databases
determine the channel types available when adding a GPS channel to the test setup.
5.12 Vehicle Bus Module
The EDIO and ECOM layers support vehicle bus modules (VBM). For the EDIO, only
connectors |1-4| and |5-8| on bank A support a VBM. Use a SAC-EXT-VB Extension
Cable (1-SAC-EXT-VB-2) to connect the VBM and eDAQ. If using an additional
extension cable, make sure the cable connected directly to the eDAQ is the
SAC-EXT-VB cable. Keep cabling less than 30 meters in length to avoid transmission
failures.
I2740-2.1 en 111
SoMat eDAQ
Plug in the VBM with the eDAQ power off. When power is supplied, the eDAQ
recognizes the VBM during boot up. Each VBM supports one type of vehicle bus
hardware interface. The available VBMs are:
CAN
J1850 VPW
J1708
ISO9141/KWP2000
NOTE
To use a VBM on the eDAQ EDIO layer, first install a special version of the layer
firmware. Refer to the firmware installation instructions in the installation directory for
specific details. When the VBM firmware is loaded, pulse counter channels on bank A
are not available.

5.12.1 VBM Available Inputs
Vehicle Bus
Each vehicle bus module supports up to 254 channels. The available channels
depend on the vehicle bus type and the selected databases. When the eDAQ receives
vehicle bus message packets, they are time stamped, processed into individual data
streams and re-sampled as necessary to the user-selected output rate. For more
information on setting up vehicle bus inputs, see Bus-Oriented Input Channels on
page 135.
Vehicle Bus Message
A vehicle bus message channel acquires raw vehicle bus packets. Every packet is time
stamped upon receipt and can subsequently be stored in the specialized Message
Logger DataMode. For more information on setting up vehicle bus message inputs,
see Vehicle Bus Message Channel on page 137.
5.12.2 VBM Configuration Options
NOTE
These configuration options also apply to the dedicated CAN interface on the ECOM
layer, the EHLB vehicle bus sub-layer and the serial bus port.

Hardware Interface
Select the desired vehicle bus hardware interface.
Databases
Select one or more database files from the presented list. The selected databases
determine the channel types available when adding a vehicle bus channel to the test
setup.
Hardware Specifics
Configure parameters that are applicable to specific vehicle bus hardware interfaces.
SoMat eDAQ
112 I2740-2.1 en
Disable Active Querying
Select the disable active querying option to disable active querying for all vehicle bus
input channels.
Max Rate
If the disable active querying option is not selected, specify the maximum active query
rate which overrides any higher query rates defined in the individual vehicle bus input
channel setups.
Override Database Definitions
Select the override database definitions option to modify the default source address
(i.e., vehicle bus node address).
Source Address
If the override option is selected, specify the desired source address byte in
hexidecimal format.
5.13 SMART Modules
SMART module adapters act as an interface between a transducer and an EHLS input
channel which powers the module. Each SMART module provides specialized signal
conditioning as a front end to the EHLS signal conditioning and includes independent
self-identification capabilities and self-calibration parameters. The following table lists
the available SMART modules.
For more information on setting up SMART module input channels, see SMART
Module Input Channels on page 131. For information on wiring SMSTRB4 inputs, see
SMSTRB4 (Strain SMART Module) on page 227.
Option VB Interface(s) Description
Baud Rate CAN, PWM,
ISO9141/KW2000
Specify the desired baud rate.
Transducer Power ECOM dedicated
CAN ports only
Specify the desired transducer power in the
range of 3 to 24 volts (10%)
Internal Termination CAN Select to provide internal vehicle bus
termination.
SMART Module Order Number Description
SMSTRB4 Strain
SMART Module
1-SMSTRB4-120-2 or
1-SMSTRB4-350-2
The SMSTRB4 supports full-, half- and
quarter- bridge transducers and includes 5-
and 10-volt excitation options and internal
shunt calibration using either 50- or
100-kilohm shunt resistors with both upscale
and downscale shunting options.
SMITC
Thermocouple
SMART Module
1-SMITC-2 The SMITC supports fully-isolated
thermocouples of type J, K, T or E over the full
temperature range of the thermocouple.
I2740-2.1 en 113
SoMat eDAQ
Installation
The eDAQ does not sense when a SMART module is installed or removed. After
connecting a module, either cycle the eDAQ power or perform a hardware query to
detect the installed SMART module. In both of these cases, the eDAQ applies power
and sends a query to all EHLS channels that support SMART modules. Note that the
SMART modules remain in a default configuration until an action such as starting a
DVM display, performing a calibration or initializing a test. This also means that a
configured SMART Module that is removed and reinstalled reverts to an unconfigured
state until one of these same actions.
Flash Memory
All SMART modules have three logical segments of flash memory. Two are reserved
for factory use; one to store the microprocessor execution code and the other to store
serial number and factory calibration parameters. The third area is the user data
segment broken into two logical partitions.
1. The first partition holds TCE parameters that can completely configure the TCE
transducer channel setup when the SMART module is installed. If no information
exists in this partition, TCE sets up the transducer channel in a default mode when
the module is added.
2. The second partition is designed for pass-through information not used by TCE.
Add any desired information such as physical locations of transducers or
associated vehicle or system indentifications. All pass-through keywords must start
with the prefix UI_ (UI followed by the underscore character).
5.14 Axis Network Camera Devices
5.14.1 Network Camera Available Inputs
Camera Message Channel
The camera message channel is a sequence of JPEG images from a networked Axis
camera device. The eDAQ timestamps the images as it receives them at a maximum
rate of 30 frames per second. Configure the image size, compression and frame rate
in the transducer setup window of TCE. For more information on the camera message
input channel, see Network Camera Input Channel on page 138.
5.14.2 Network Camera Configuration
NOTE
The discovery and hardware configuration for the Axis network cameras are in the
eDAQ web interface.

Necessary Equipment
TCE supports the following Axis devices:
SoMat eDAQ
114 I2740-2.1 en
NOTE
HBM only supports the devices listed in the above table and assumes no risk if any
other devices are used.

To set up an Axis network camera, the following is required:
a networked eDAQ or eDAQlite with firmware version 3.14 or later
a support PC with a JavaScript-enabled web browser
a TCP/IP network (DHCP recommended)
Setting the Camera to Factory Defaults
To configure a new camera or reconfigure an existing camera, first set it to factory
defaults.
To reset the camera to factory defaults:
1. Remove power from the camera.
2. Press and hold the small black reset button.
3. Apply power to the camera.
4. After the status indicator blinks off and on, release the reset button. Note that, on
the Axis 211, the light to watch is on the front of the camera and not next to the reset
button.
5. Wait for the status indicator to change to green. This may take up to two minutes.
Configuring a Camera
To configure an Axis network camera:
1. Power on the camera and connect it to the network via an Ethernet cable.
2. Open a Javascript-enabled web browser and enter the IP address of the networked
eDAQ to display the eDAQ web interface.
3. Click on the hardware tab and then Manage Network Cameras beneath the
hardware table to navigate to the camera setup page.
4. Click the Find Network Cameras button under Available Networked Cameras to
add the networked camera. The new entry is named Misconfigured Camera.
Figure 5-10: Example entry for an unconfigured camera labeled as Misconfigured Camera.
5. Verify that the serial number for the new entry matches the serial number on the
shell of the camera. If it does not match, follow the troubleshooting steps in the next
section.
6. Click on the correct camera configuration link under the camera entry to open the
camera configuration page. Follow the on screen instructions to assign the camera
an IP address.
Axis Device Compatible TCE Version
Axis 211 Network Camera TCE 3.14 or later
Axis M7001 Video Encoder TCE 3.15 or later
I2740-2.1 en 115
SoMat eDAQ
7. Wait during the configuring camera screen for the camera to be properly configured
and the web interface to return to the manage network cameras page. If the
configuration fails, try power cycling any switches or routers on the network. If
problems persist, refer to the troubleshooting steps in the next section.
Figure 5-11: Example entry for a properly configured camera.
8. Click the select this camera link under the camera entry to add the camera to the
Selected Network Cameras list. (If there is no camera under Available Networked
Cameras click the Find Cameras on Network button.)
Figure 5-12: Selected Networked Cameras table showing the cameras to be added to the
eDAQ hardware list.
9. Click the update eDAQ hardware list to reset the eDAQ and add the camera to the
eDAQ hardware table on the main hardware page.
NOTE
Once configured, a camera my be used by any networked eDAQ or eDAQlite simply
by following steps 8 and 9 for each system. However, the camera cannot provide the
maximum frame rate to more than one eDAQ system at a time. For example, two
eDAQs using the same camera and configured to request 30 frames per second only
receive a maximum of 15 frames per second each.

5.14.3 Network Camera Troubleshooting
Most of the issues that can cause the camera to not function properly are network
related. Try the following to troubleshoot any camera issues.
Troubleshooting During Configuration
To troubleshoot during camera configuration:
Repeat the camera configuration steps outlined in Configuring a Camera on
page 114.
Power cycle any switches or routers on the network.
If camera cannot be found on the network, try entering the camera serial
number in the Configure Networked Camera section of the web interface to
search for the specified camera.
Reset the camera to its factory default as outlined in Setting the Camera to
Factory Defaults on page 114 and repeat the camera configuration.
If the problem persists:
Consult with the local IT department to resolve any network issues.
SoMat eDAQ
116 I2740-2.1 en
Contact HBM SoMat customer service. Please carefully record all
troubleshooting results before contacting HBM SoMat.
Troubleshooting After Configuration
To troubleshoot a previously configured camera:
1. Ping the cameras IP address to confirm that the eDAQ can communicate with the
camera. To ping the camera, navigate to the system tab on the web interface and
click Command Prompt. In the command prompt, type ping xxx.xxx.xxx.xxx,
where the xs are the IP address for the camera.
2. If there is no reply, check all the network connections including Ethernet cables,
routers and switches. Make sure the link LEDs on the bottom of the camera near
the Ethernet port are active.
3. If there is a ping reply but the problem remains, reset the camera to its factory
default as outlined in Setting the Camera to Factory Defaults on page 114 and
repeat the camera configuration.
If the problem persists:
Consult with the local IT department to resolve any network issues.
Contact HBM SoMat customer service. Please carefully record all
troubleshooting results before contacting HBM SoMat.
Configured Axis M7001 Does Not Show Video
When using the Axis M7001, make sure to close all live video feeds before recording
data. Because of resolution restrictions, the M7001 cannot deliver video for recording
or as a thumbnail and as a live, full-resolution feed (opened by clicking the thumbnail
in the hardware specifics column on the web interface).
I2740-2.1 en 117
SoMat eDAQ
6 Input Channels
This chapter details all of the available input channels and their parameters. To acquire
data during a test, define input channels for each input signal in the transducer setup
window. Input channels can be transducer channels, message channels or data
channels derived from various message-oriented data sources. Each channel
definition contains some common information such as the ID tag, the hardware
connector ID, output data type, desired full-scale range and output sample rate. In
addition, each channel type has specific parameters that must be defined.
6.1 Common Input Channel Parameters
6.1.1 Desired Measurement
ID
Specify a unique identifier for the channel. The name must conform to ID naming
conventions. Valid ID names:
are case sensitive
are limited to a maximum of 12 characters
contain only valid characters (i.e., letters (a-z, A-Z), digits (0-9), and the
underscore (_) character)
start with a letter
are not duplicates of system reserved names (sin, cos, log, etc.)
Connector
Hardware connector IDs identify connector assignments for transducers. The default
ID consists of the eDAQ IP address or host name, layer identifier and the
physical/logical channel as specified in the hardware setup. The following examples
illustrate the eDAQ conventions.
ECPU: Connector IDs MPB.c01 through MPB.c08 denote the eight pulse
counter transducer channels and MPB.bwi denotes the set of digital inputs.
EBRG: For an EBRG layer with an ID of Brg_1, connector IDs Brg_1.c01
through Brg_1.c16 denote the set of 16 bridge transducer connections.
EDIO: For an EDIO layer with an ID of DIO_1, connector IDs DIO_1.apc1
through DIO_1.apc6 denote the set of 6 pulse counter connections on Bank A
and DIO_1.bpc1 through DIO_1.bpc6 denote the set of 6 pulse counter
connections on Bank B.
Description
Use up to 63 characters to more fully identify the transducer.
Type
Specify the type of measurement, such as strain, load or acceleration, associated with
the transducer or computed channel. Select a type from the list or directly enter a
user-defined type. Since TCE uses the value of the type field throughout the test setup
process, always complete this field.
Units
Specify the measurement units for the transducer. Since TCE uses the value of the
units field throughout the test setup process, always complete this field.
SoMat eDAQ
118 I2740-2.1 en
6.1.2 Output Sample Rate
Output Sample Rate
Select the sample rate for the input channel. The sample rate options are factors of the
defined master sample rate (100 kHz or 98.04 kHz). The sample rate should be at
least two times the maximum frequency content of the input signal to ensure that the
bandwidth of the signal is completely characterized. When available, using a digital
filter can limit the frequency content of the input signal.
6.1.3 Full-Scale Values
Full-Scale Min and Max
Specify the expected extreme values for the transducer. When storing a 32-bit float in
a DataMode that uses an integer data type, the eDAQ uses the full-scale limits when
converting from the floating point format to the integer format. The eDAQ also uses the
full-scale estimates to set the default bin boundaries for histogram DataModes and to
set the scales for run-time displays.
Input channels on layers that have programmable gain and offset capabilities use the
full-scale values in conjunction with the calibration parameters to determine the gain
and offset values. The eDAQ provides some over range protection of 1% on EHLS and
EBRG channels and 5% on ELLB channels. For example, specifying full-scale values
of 2000 microstrain on an EHLS channel causes the eDAQ to set up the gain and
offset circuitry as close as possible to 2020 microstrain without going under.
6.1.4 Output Data Type
Output Data Type
Depending on the channel type, the eDAQ provides several data type options. When
choosing the data type, consider factors such as data resolution, mass storage
consumption and what computed channels or DataModes use the channel as an
input. For a summary of the compatible data types for all computed channels and
DataModes, see Data Types on page 203.
NOTE
The Engineering Scaler computed channel generates a 32-bit floating point output
data stream from an integer type input channel. This permits storing data in an integer
format to minimize data storage consumption while still using the data in a computed
channel which requires a 32-bit floating point input data type. For more information on
the Engineering Scaler computed channel, see Engineering Scaler on page 147.

6.1.5 Calibration Table
The calibration area of parameters includes the fields necessary to set up a calibration
for an input transducer. Some transducer types have extra options not covered in this
section. For more information on calibrating transducers, see Calibrating Input
Channels on page 67.
Mode
Select the desired calibration mode.
I2740-2.1 en 119
SoMat eDAQ
Engineering Value
Specify the calibration value in engineering units.
Input Signal Value
Specify the corresponding signal value for the defined value and defined span
calibration modes.
Calibrate
Select calibrate to begin calibration for the selected channel. If the transducer is
already calibrated, TCE presents more calibration options.
NOTE
Calibration is only available for defined channels on a connected eDAQ.

Calibration Date
TCE automatically enters the calibration date upon transducer calibration.
6.1.6 Prerun Rezero
Mode
Select the prerun rezero mode for the transducer. Interactive rezeroing is available for
all modes except Not applicable. Prerun rezeroing does not affect the fundamental
transducer calibration definition. Prerun zero offsets are effective for the duration of the
test only.
NOTE
The eDAQ never performs rezeroing on test runs started after a reset caused by an
exception error (e.g., Timeout, Calibration or DeviceOverFlow).

Mode Description
Not applicable No rezeroing required.
Interactive only Rezero interactively only (no automatic rezeroing).
First run only Automatically rezero immediately prior to the start of the first test run
only.
All runs (except
power fails)
Automatically rezero immediately prior to the start of every test run
except test runs initiated by eDAQ power fail resets.
All runs Automatically rezero prior to the start of every test run. This option is
not advised for low level inputs.
SoMat eDAQ
120 I2740-2.1 en
Value
Specify the engineering value associated with the transducer when rezeroed.
NOTE
There is a limitation on rezeroing low level signal conditioners when using high level
input levels. If the rezero results in the situation where the full-scale values exceed the
voltage limits of the signal conditioner, a calibration error occurs before the test run
starts. For example, suppose the full-scale values are 10.0 volts for a signal
conditioner with a range of 10.2 volts. If the rezero offset is 0.5 volts, the eDAQ
attempts to set limits of -9.5 and +10.5 volts causing a calibration error to occur
because the +10.5 volt limit cannot be achieved.

NOTE
For quadrature decoder channels, the eDAQ resets the internal counter value to zero
before rezeroing.

6.1.7 Display Control
Scope
Select the Scope button to open a scope plot display for the input channel. Note that
the Scope Plot is similar to an analog oscilloscope except that the display is not
updated until the eDAQ acquires all of the data samples and transferred them to the
host computer, which creates a delay in the data presentation. For more information
on the scope plot, see Scope Plot on page 83.
DVM
Select the DVM button to open a DVM display of the input channel. In this display
mode, the transducer signals are repetitively sampled and displayed in a digital format.
For more information on the DVM display, see DVM on page 82.
6.2 Digital Input Channels
6.2.1 Digital Input
Add a digital input channel to any bit on an EDIO or ECPU layer. The eDAQ uses
standard switching logic to determine the boolean state of the channels. For more
information on EDIO digital inputs, see EDIO Digital Input/Output on page 99. For
more information on ECPU digital inputs, see ECPU Digital Input/Output on page 95.
NOTE
The last four bits (9-12) on each bank of the EDIO are dedicated to wide range input
channels.

Output Data Type
The output data type for digital inputs is always 8-bit unsigned (logical).
I2740-2.1 en 121
SoMat eDAQ
6.2.2 Pulse Counter
For the EDIO, the eDAQ allows two pulse counter channels on each of the three
connectors (i.e., bits |1-4|, |5-8| and |9-12|) on each EDIO bank (i.e., A, B and C). Note
that the quadrature decoder mode requires two adjacent input bits (i.e., 1-2 or 3-4 for
the first connector) and the odd numbered input connector pin is typically designated
encoder output A, while the even numbered input connector pin is typically designated
encoder output B.
For EDIO pulse counters, the connector selection is different from other input
channels. For each pulse counter, select the EDIO layer from the board drop down list,
bank and connector using the corresponding radio button and input bit from the
provided drop down list.
For the ECPU, add a pulse counter channel to any input bit. Note that the duty cycle
mode requires two adjacent input bits (i.e., 1-2, 3-4, 5-6 or 7-8) for each duty cycle
pulse counter. The input signal must be physically connected to the odd numbered
input connector pin only (i.e., 1, 3, 5 or 7).
For more information on EDIO pulse counters, see EDIO Pulse Counter on page 99.
For more information on ECPU pulse counters, see ECPU Available Inputs and
Outputs on page 95.
NOTE
Because the duty cycle (ECPU) and quadrature decoder (EDIO) modes require two
input bits, it is recommended to define these pulse counter first before other types of
pulse counter channels.

Output Data Type
Select an output data type of 32-bit float, 32-bit unsigned or 32-bit integer. The 32-bit
float data type allows any of the operational modes. The 32-bit unsigned type limits the
available operational modes to time period, on time and pulse rate while the 32-bit
integer type is available only with the quadrature decoder mode. The 32-bit unsigned
and integer data types are considerably more efficient from a processing point of view.
NOTE
If the quadrature decoder input channel is expected to exceed about 16000000 counts
then using the 32-bit integer data type is required since the 32-bit float data type starts
to lose resolution around this count. To put this in some perspective, a 2048 counts per
revolution quadrature encoder on a shaft rotating at 3000 RPM accumulates
16000000 counts in about 2.5 hours; however, it takes about 350 hours to accumulate
2147483647 counts, the maximum value of the 32-bit integer data type.

SoMat eDAQ
122 I2740-2.1 en
Mode
There are several operational modes available for the pulse counter channel.
Mode Description
Pulse Time Period Output the pulse period in microseconds. The unsigned 32-bit counter
can measure pulse widths from 200 nanoseconds to approximately
850 seconds. Because this mode is the most efficient from a
processing point of view, consider using it for measuring the same
types of parameters as the frequency mode when the eDAQ is near its
performance limit or when post test processing can perform the
calculations.
Pulse Frequency Output the instantaneous frequency of the input signal computed as
the reciprocal of the period between the last two falling edges of the
signal. Use this mode for applications including measuring vehicle
speed and engine RPM. The output data type must be 32-bit float. For
important application information, see Pulse Frequency Mode Notes
on page 123.
Pulse Rate Output the number of pulse counts in one sample period in units of
pulses per second (Hz). Use this mode in conjunction with the
Integrator computed channel to measure accumulated pulse counts or
other parameters that are directly proportional to accumulated pulse
counts (such as distance traveled, revolutions, etc.). The eDAQ can
accumulate over 4 billion counts in each sample period; however, the
maximum pulse rate is limited to approximately 1.0 MHz.
Duty Cycle (ECPU
only)
Output the duty cycle as a dimensionless ratio. Use this mode for
specialized transducers that generate output pulse trains where the
duty cycle of the pulses is directly proportional to the desired
measurement. The effective working range for this mode is nominally
0.5 Hz to 50 kHz. However, since there are two inputs with accuracy
limitations, use this mode only for pulse trains running at 20 kHz or less
for the best results.
Pulse On Time Period
(EDIO only)
Output the time period in microseconds that the pulse is at logic 1. The
unsigned 32-bit counter can measure pulse on time widths from 200
nanoseconds to approximately 850 seconds. Use a Desk Calculator
computed channel (see Desk Calculator on page 144) to compute
duty cycle as the pulse on time period divided by the pulse time period.
Quadrature Decoder
(EDIO only)
Output the encoder position in terms of the accumulated encoder
counts. The signed 32 bit counter can accumulate over 2 billion counts
in either direction before the counter rolls over.
I2740-2.1 en 123
SoMat eDAQ
Pulse Frequency Mode Notes
Consider the following when using a pulse counter in frequency mode.
The effective working range for the ECPU in this mode is nominally 0.5 Hz to 50 kHz. Because the EDIO uses a 32-bit
counter instead of a 24-bit counter used by the ECPU, it has an effective working range in this mode of less than 0.002
Hz.
The accuracy of the frequency measurement is inversely proportional to the measured frequency. For example, at a
frequency of 50 kHz, 100 counts are accumulated in the counter resulting in a 1.0% measurement accuracy; at a
frequency of 5 kHz, 1000 counts are accumulated in the counter resulting in a 0.1% measurement accuracy.
When the input signal pulse frequency is greater than the sample rate, the eDAQ latches the first pulse frequency
measured until it reads the value effectively ignoring subsequent pulses that occur in the sample period after the
latched pulse. When the input signal pulse frequency is less than the sample rate, the eDAQ uses the stored pulse
frequency for the previous output sample.
When the input signal pulse train stops for an extended period of time, the following occurs. For the ECPU counters,
the 24-bit register saturates in about 3.3 seconds. When this occurs, the saturation frequency of about 0.3 Hz is latched
and output until the pulse train starts again. The EDIO counters use 32-bit registers, which saturate in about 850
seconds and keep track of the last output pulse period value and the time elapsed since the last pulse was detected.
If sufficient time passes with no new pulse detected, the output is adjusted downward to account for the fact the pulse
period is greater than what was previously latched. This results in the output pulse frequency value continuously
decaying until a new pulse is detected.

High Frequency Inputs in the Pulse Rate Mode
Use the pulse rate mode to cover the high frequency input range that cannot be accurately covered using the frequency or
time modes (i.e., 50 kHz to 1 MHz). The resolution of the average input frequency is equal to the input sample rate. For
example, for an input with a 100 Hz sample rate and 6543 pulses in one sample period, the average input frequency over the
sample period is 654300 Hz (i.e., the resolution is 100 Hz). To make use of the pulse rate mode, the channel must have a
large number of pulses in each sample period.
To cover both low and high frequency inputs, route the input signal into two pulse counter channelsone configured in
frequency mode and the other in rate modeand use the following expression in a Desk Calculator computed channel (see
Desk Calculator on page 144).
(X_r > R_max) * X_r + (X_r <= R_max) * X_f
where, X_r is the rate mode, X_f is the frequency mode and R_max is the crossover point where X_r is used instead of X_f.
Set R_max to minimize accuracy loss. For example, if the sample rates are both 100 Hz, then set R_max to 25000 Hz, where
the accuracy of X_f is 0.5% and the accuracy of X_r is 0.4%.

6.3 Analog Input Channels
6.3.1 Bridge
Add a bridge channel to any EBRG connector. For more information on the EBRG
layer, see EBRG (Bridge Layer) on page 102.
NOTE
Each channel on the EBRG layer can have an independent sample rate and digital
filter selection.
SoMat eDAQ
124 I2740-2.1 en

Output Data Type
Select an output data type of 16-bit signed, 32-bit float or 8-bit signed. The
fundamental data type for bridge channels is 16-bit signed, which consumes the least
amount of data storage while maintaining full 16-bit data resolution. The 32-bit float
data type adds a great deal of computational overhead and is not recommended for
high rate data collection. Use the 32-bit floating point option only if the input channel
is to be used in subsequent computed channels or DataModes that require the input
channels to be 32-bit floating point. The 8-bit signed data type adds some
computational overhead, but may be useful when only a rough picture of the
transducer data is required and/or data storage limitations are a major concern.
Digital Filter Type
Select the desired type of digital filtering for the channel. Digital filters ensure that
aliasing of the input signal does not occur. Always use a digital filter unless absolutely
certain of the frequency content of the input signal. The filter options are an eight-pole
Butterworth filter or a linear phase filter. For more information on digital filtering, see
Digital Filtering on page 243.
Break Frequency
Specify the break frequency in hertz for the selected digital filter. For a Butterworth
filter, this is the approximate frequency at which the signal attenuation is 3 dB or 70.7%
of the unfiltered signal voltage at that frequency. For a linear phase filter, the field is
named the roll off start frequency and is the approximate frequency at which the signal
starts to attenuate.
The eDAQ automatically selects a default break frequency value to ensure that no
aliasing occurs. The selection is based on the A/D converter rate and the choice of
digital filter type.
NOTE
The check box field labeled data is protected from aliasing indicates whether the
current digital filter selection ensures no aliasing. TCE automatically updates the field
when the digital filter configuration changes. For example, the 100-kHz sample rate
option precludes aliasing because it is well over the Nyquist frequency of two times the
25 kHz analog guard filter. However, the 50-kHz sample rate option does not fully
preclude against aliasing because the guard filter only attenuates about 30% of the
25-kHz input signal content.

Excitation Range
The excitation range setting determines the magnitude of the bipolar voltage applied
to the red +EXC and black -EXC wires of the transducer cables. Note that a range of
X volts DC results in +X/2 to -X/2 pin out voltages. Select one of the following discrete
ranges: 10, 5, or 0 volts DC. The maximum current which can be supplied is 51
milliamps at either 5 or 10 volts DC.
I2740-2.1 en 125
SoMat eDAQ
If signal excitation is required for the transducer, which is always the case when using
an actual bridge, consult the transducer manufacturer's specifications and/or
suggestions for excitation settings. If signal excitation is not required for a particular
transducer, leave the excitation in the default initial state and set the excitation
proportional parameter to no.
NOTE
For the BRG.01 models, all channels must have the same excitation voltage for any
given bridge layer. For the BRG.02 models and later, all channels in any given bank of
four channels (1-4, 5-8, 9-12 and 13-16) must have the same excitation voltage.

Bridge Type
Select the bridge type to match the transducer or select the differential amplifier option
if the transducer does not use a bridge. The available types are full bridge, half bridge,
quarter bridge and differential amplifier.
Output Proportional to Excitation
Select the proportional excitation option if the output signal is linearly proportional to
the applied excitation signal as it is for bridge type transducers. When using this option,
the eDAQ makes a minor correction for the fact that the set excitation voltage cannot
be exact.
Bridge Resistance
For quarter bridge configurations, the value defaults to the provided completion
resistor. If necessary, modify the value if the actual strain gage has a slightly different
resistance. For either full or half bridge configurations, select any resistance in the
range of 100 to 10000 ohms.
Gage Factor
Define the gage factor for the specific strain gages used. TCE uses this value only in
the shunt tool calibration option that defines an equivalent strain based on the gage
factor and bridge factor values.
Bridge Factor
Define the bridge factor for the specific configuration of strain gages used. TCE uses
this value only in the shunt tool calibration option that defines an equivalent strain
based on the gage factor and bridge factor values. The bridge factor is defined here
as the arithmetic sum of the active bridge legs for any bridge configuration. For
quarter-bridge applications, the bridge factor is normally one; for half-bridge
applications where both active gages are additive, it is normally two; and for full-bridge
applications where all active gages are additive, it is normally four. Because there are
special applications where the bridge factor can be a fraction and/or a negative value
TCE considers any nonzero value valid.
SoMat eDAQ
126 I2740-2.1 en
Leadwire Resistance Correction
Select the leadwire resistance correction option to compensate for leadwire resistance
effects when using the defined span or external span calibration modes.
NOTE
The eDAQ always performs leadwire resistance correction for shunt calibrations.

Leadwire Resistance
Specify the value of the leadwire resistance when using the leadwire resistance
correction option. The resistance input is the resistance of one lead, ideally measured
from the EBRG layer connector pin to the connection at the active bridge leg. It is
presumed that all lead wires are approximately the same length. Quarter-bridge
applications require the use of all three wires.
To accurately measure the leadwire resistance, use the four-wire resistance
measurement method. Nominal resistance values for transducer cable wires can help
to estimate the leadwire resistance (see Cable Resistances on page 255). However,
since contact resistances at mechanical connections are difficult to estimate, measure
the leadwire resistance for optimum accuracy.
Alternatively, TCE can back calculate the leadwire resistance if the bridge resistances
are equal and known and if the resistances of the three relevant leadwires are equal.
To use this method, the bridge type and bridge resistance fields must be correct.
Ensure the transducer is stable and then click the back calculate resistance option.
Back Calculate Resistance
Select the back calculate resistance option to experimentally measure the leadwire
resistance. Note that the measurements are only valid when the bridge resistances
are equal and all leadwire resistances are equal. If the resulting values show
significant difference between the upscale and downscale resistance values, the three
relevant leadwires are not equal and the back calculate method is invalid.
Resistor to Shunt Across
Select either the upscale (-Sig to -Ex) shunt option or the downscale (-Sig to +Ex)
shunt option. Note that the downscale shunt option results in a negative span signal
value.
6.3.2 Simultaneous High Level
Add a simultaneous high level input to any EHLS connector. For more information on
the EHLS layer, see EHLS (High Level Analog Layer) on page 103.
NOTE
Each channel on the EHLS layer can have an independent sample rate and digital filter
selection.

I2740-2.1 en 127
SoMat eDAQ
Output Data Type
The fundamental data type for EHLS channels is 16-bit signed, which consumes the
least amount of data storage while maintaining full 16-bit data resolution. The 32-bit
float data type adds a great deal of computational overhead and is not recommended
for high rate data collection. Use the 32-bit floating point option only if the input channel
is to be used in subsequent computed channels or DataModes that require the input
channels to be 32-bit floating point. The 8-bit signed data type adds some
computational overhead, but may be useful when only a rough picture of the
transducer data is required and/or data storage limitations are a major concern.
Digital Filter Type
Select the desired type of digital filtering for the channel. Digital filters ensure that
aliasing of the input signal does not occur. Always use a digital filter unless absolutely
certain of the frequency content of the input signal. The filter options are an eight-pole
Butterworth filter or a linear phase filter. For more information on digital filtering, see
Digital Filtering on page 243.
Break Frequency
Specify the break frequency in hertz for the selected digital filter. For a Butterworth
filter, this is the approximate frequency at which the signal attenuation is 3 dB or 70.7%
of the unfiltered signal voltage at that frequency. For a linear phase filter, the field is
named the roll off start frequency and is the approximate frequency at which the signal
starts to attenuate.
The eDAQ automatically selects a default break frequency value to ensure that no
aliasing occurs. The selection is based on the A/D converter rate and the choice of
digital filter type.
NOTE
The check box field labeled data is protected from aliasing indicates whether the
current digital filter selection ensures no aliasing. TCE automatically updates the field
when the digital filter configuration changes. For example, the 100-kHz sample rate
option precludes aliasing because it is well over the Nyquist frequency of two times the
25-kHz analog guard filter. However, the 50-kHz sample rate option does not fully
preclude against aliasing because the guard filter only attenuates about 30% of the
25-kHz input signal content.

SMART Module
Use the SMART module section of the setup to configure a connected SMART
module. For more information on setting up a SMART module channel, see SMART
Module Input Channels on page 131.
Voltage Divider Option
Use the voltage divider option to increase the full-scale input range from 10.0 volts to
74.9 volts. This option uses a resistive voltage divider circuit with an input impedance
of only 100 kilohms compared to 10 megohms without the divider circuit. Ensure that
the transducer output is not dragged down by this relatively low input impedance when
using this option.
SoMat eDAQ
128 I2740-2.1 en
Transducer Power
Set the power supply voltage from 3 to 28 volts in integral steps of one volt. The power
is limited to approximately 400 milliwatts for each channel. If the transducer does not
require power, set the power to 0.
NOTE
For certain types of SMART modules, the transducer power is restricted to the
following: 15 volts for the SMSTRB4 with ten-volt excitation, eight volts for the
SMSTRB4 with five-volt excitation and eight volts for the SMITC.

NOTE
To supply power greater than 400 milliwatts to a single transducer, define multiple
channels and tie their power sources together. All the channels used for a single
transducer must have the same voltage settings.

6.3.3 High Level
NOTE
The same sample rate must be specified for all high level transducers for all high level
layers in any eDAQ stack.

Output Data Type
The fundamental data type for high level channels is 16-bit signed, which consumes
the least amount of data storage while maintaining full 16-bit data resolution. The
32-bit float data type adds a great deal of computational overhead and is not
recommended for high rate data collection. Use the 32-bit floating point option only if
the input channel is to be used in subsequent computed channels or DataModes that
require the input channels to be 32-bit floating point. The 8-bit signed data type adds
some computational overhead, but may be useful when only a rough picture of the
transducer data is required and/or data storage limitations are a major concern.
Voltage Divider Option
Use the voltage divider option to increase the full-scale input range from 10.0 volts to
20.0 volts. This option uses a resistive voltage divider circuit with an input impedance
of only 100 kilohms. Ensure that the transducer output is not dragged down by this
relatively low input impedance when using this option.
6.3.4 Low Level
NOTE
The same sample rate and digital filter must be specified for all low level transducers
for any given low level layer.
I2740-2.1 en 129
SoMat eDAQ

Output Data Type
The fundamental data type for low level channels is 16-bit signed, which consumes the
least amount of data storage while maintaining full 16-bit data resolution. The 32-bit
float data type adds a great deal of computational overhead and is not recommended
for high rate data collection. Use the 32-bit floating point option only if the input channel
is to be used in subsequent computed channels or DataModes that require the input
channels to be 32-bit floating point. The 8-bit signed data type adds some
computational overhead, but may be useful when only a rough picture of the
transducer data is required and/or data storage limitations are a major concern.
Digital Filter Type
Select the desired type of digital filtering for the channel. Digital filters ensure that
aliasing of the input signal does not occur. Always use a digital filter unless absolutely
certain of the frequency content of the input signal. The filter options are an eight-pole
Butterworth filter or a linear phase filter. For more information on digital filtering, see
the Digital Filtering on page 243.
Break Frequency
Specify the break frequency in hertz for the selected digital filter. For a Butterworth
filter, this is the approximate frequency at which the signal attenuation is 3 dB or 70.7%
of the unfiltered signal voltage at that frequency. For a linear phase filter, the field is
named the roll off start frequency and is the approximate frequency at which the signal
starts to attenuate.
The eDAQ automatically selects a default break frequency value to ensure that no
aliasing occurs. The selection is based on the A/D converter rate and the choice of
digital filter type.
NOTE
The check box field labeled data is protected from aliasing indicates whether the
current digital filter selection ensures no aliasing. TCE automatically updates the field
when the digital filter configuration changes.

Excitation Range
The excitation range setting determines the magnitude of the bipolar voltage applied
to the red +EXC and black -EXC wires of the transducer cables. Note that a range of
X volts DC results in +X/2 to -X/2 pin out voltages. Select one of the following discrete
ranges: nominal 22, 20, 10 or 5 volts DC. The maximum current which can be supplied
is 42 milliamps at 5 volts, 29 milliamps at 10 volts or 21 milliamps at 20 volts. The
nominal 22-volt range is an unregulated voltage and, therefore, cannot be used for
bridge transducers or any other type of transducer that has an output proportional to
the excitation voltage.
NOTE
TCE does not allow usage of the provided 0-volt excitation option.
SoMat eDAQ
130 I2740-2.1 en

If signal excitation is required for the transducer, which is always the case when using
an actual bridge, consult the transducer manufacturer's specifications and/or
suggestions for excitation settings. If signal excitation is not required for a particular
transducer, leave the excitation in the default initial state and set the excitation
proportional parameter to no.
NOTE
All channels for any given low level layer must have the same excitation voltage.

Bridge Type
Select the bridge type to match the transducer or select the differential amplifier option
if the transducer does not use a bridge. The available types are full bridge, half bridge,
quarter bridge, and differential amplifier.
Output Proportional to Excitation
Select the proportional excitation option if the output signal is linearly proportional to
the applied excitation signal as it is for bridge type transducers. When using this option,
the eDAQ makes a minor correction for the fact that the set excitation voltage cannot
be exact.
Bridge Resistance
For quarter bridge configurations, TCE defaults this value to exactly match the
completion resistor provided but allows modification in case the actual strain gage has
a slightly different resistance. For either full or half bridge configurations, select any
resistance in the range of 100 to 10000 ohms.
Leadwire Resistance Correction
Select the leadwire resistance correction option to compensate for leadwire resistance
effects when using the defined span or external span calibration modes.
NOTE
TCE always performs leadwire resistance correction for shunt calibrations that do not
use the six-wire shunt option.

NOTE
For bridge transducers configured for the six-wire shunt mode and also have
significant leadwire resistance, TCE reports that the deviation from the ideal shunt
behavior is off by a significant amount when calibrating the transducer channel. As an
example, for a leadwire resistance of 5 ohms in each leg of a 350-ohm bridge, TCE
reports a deviation of about 2.8%.

I2740-2.1 en 131
SoMat eDAQ
Leadwire Resistance
Specify the value of the leadwire resistance when using the leadwire resistance
correction option. The resistance input is the resistance of one lead ideally measured
from the ELLB connector pin to the connection at the active bridge leg. It is presumed
that all lead wires are approximately the same length. Quarter bridge applications
require the use of all three wires.
To accurately measure the leadwire resistance, use the 4-wire resistance
measurement method. Nominal resistance values for transducer cable wires can help
to estimate the leadwire resistance (see Cable Resistances on page 255). However,
since contact resistances at mechanical connections are difficult to estimate, measure
the leadwire resistance for optimum accuracy.
The nominal leadwire resistance value for a 2-meter SAC-EXDUC ELLB Transducer
Cable (1-SAC-EXDUC-2) measured at the pigtails is 0.165 ohms for the 24 AWG
cable and 0.445 ohms for the 28 AWG cable. The nominal leadwire resistance value
measured at the solder pins of the D-Sub cable connector that mates to the eDAQ
front panel D-Sub is 0.025 ohms.
Resistor to Shunt Across
Select either the upscale (-Sig to -Ex) shunt option or the downscale (-Sig to +Ex)
shunt option. Note that the downscale shunt option results in a negative span signal
value.
Six-Wire Shunt
Select the six-wire shunt option to use the six-wire shunt calibration mode for shunt
calibrations. When using this option with the required six-wire SAC-EXDUC-6-V ELLB
Transducer Cable (1-SAC-EXDUC-6-V-2), leadwire resistance corrections are not
permitted, even when using very long lead wires.
6.4 SMART Module Input Channels
Add a SMART module channel to any EHLS connector with an installed SMART
module. Complete the parameters for the EHLS parent channel as well as the SMART
module specific parameters. Configure the SMART module parameters by selecting
the configure option in the SMART module section of the EHLS channel setup window
(on page two). For more information on SMART modules, see SMART Modules on
page 112.
Using SMART Utilities
Access the SMART utilities in the TCE transducer setup window. Highlight a SMART channel or a set of SMART channels
and select SMART Utils. TCE offers the following three options.
ProgramSerially program all selected SMART modules with the transducer channel definition that currently exists
and with any added pass through keyword value entries.
BlankErase the selected SMART modules, restoring the user-data areas to their original blanked states.
LED LocateRepetitively toggle the LEDs of the selected SMART modules indicating the physical location of the
selected SMART modules. This function must be manually aborted.

SoMat eDAQ
132 I2740-2.1 en
6.4.1 SMSTRB4 (Strain SMART Module)
NOTE
The parameters for the SMSTRB4 are integral to the channel calibration. To edit any
of these parameters, first delete the existing calibration.

Excitation Range
The excitation range setting determines the monopolar excitation voltage applied
across the bridge. Select either 5- or 10-volt excitation for nominal bridge resistances
of 350 ohms and greater. For smaller bridge resistances, only the 5-volt excitation
range is available.
The signal input levels for SMSTRB4 transducers are limited by the excitation range
selection and the nominal gain which is determined by the calibration curve and not
directly configurable. For a 5-volt excitation range, the inputs are limited to 180
millivolts for the nominal gain of 10 or 18 millivolts for the nominal gain of 100. For a
10-volt excitation range, the inputs are limited to 360 millivolts for the nominal gain of
10 or 36 millivolts for the nominal gain of 100.
NOTE
The output voltage is always proportional to the excitation voltage. The eDAQ makes
minor corrections required to deal with slight differences in the calibrated excitation
voltage and the nominal excitation of 5 or 10 volts.

Bridge Type
Select the bridge type to match the transducer. The available types are full bridge, half
bridge and quarter bridge.
NOTE
For older SMART bridge modules, the bridge type is fixed at production.

Bridge Resistance
For quarter-bridge configurations, the value defaults to the provided completion
resistor. If necessary, modify the value if the actual strain gage has a slightly different
resistance. For either full- or half-bridge configurations, select any resistance in the
range of 100 to 10000 ohms.
Gage Factor
Define the gage factor for the specific strain gages used. TCE uses this value only in
the shunt tool calibration option that defines an equivalent strain based on the gage
factor and bridge factor values.
I2740-2.1 en 133
SoMat eDAQ
Bridge Factor
Define the bridge factor for the specific configuration of strain gages used. TCE uses
this value only in the shunt tool calibration option that defines an equivalent strain
based on the gage factor and bridge factor values. The bridge factor is defined here
as the arithmetic sum of the active bridge legs for any bridge configuration. For
quarter-bridge applications, the bridge factor is normally one; for half-bridge
applications where both active gages are additive, it is normally two; and for full-bridge
applications where all active gages are additive, it is normally four. Because there are
special applications where the bridge factor can be a fraction and/or a negative value
TCE considers any nonzero value valid.
Leadwire Resistance Correction
Select the leadwire resistance correction option to compensate for leadwire resistance
effects when using the defined span or external span calibration modes.
NOTE
The eDAQ always performs leadwire resistance correction for shunt calibrations and
transducers calibrated using the defined span or external span calibration modes.

Leadwire Resistance
Specify the value of the leadwire resistance when using the leadwire resistance
correction option. The resistance input is the resistance of one lead, ideally measured
from the SMART module connector pin to the connection at the active bridge leg. It is
presumed that all lead wires are approximately the same length. Quarter-bridge
applications require the use of all three wires.
To accurately measure the leadwire resistance, use the four-wire resistance
measurement method. Nominal resistance values for transducer cable wires can help
to estimate the leadwire resistance (see Cable Resistances on page 255). However,
since contact resistances at mechanical connections are difficult to estimate, measure
the leadwire resistance for optimum accuracy.
Alternatively, TCE can back calculate the leadwire resistance if the bridge resistances
are equal and known and if the resistances of the three relevant leadwires are equal.
To use this method, the bridge type and bridge resistance fields must be correct.
Ensure the transducer is stable and then click the back calculate resistance option.
Back Calculate Resistance
Select the back calculate resistance option to experimentally measure the leadwire
resistance. Note that the measurements are only valid when the bridge resistances
are equal and all leadwire resistances are equal. If the resulting values show
significant difference between the upscale and downscale resistance values, the three
relevant leadwires are not equal and the back calculate method is invalid.
SoMat eDAQ
134 I2740-2.1 en
Resistor to Shunt Across
Select either the upscale (-Sig to -Ex) shunt option or the downscale (-Sig to +Ex)
shunt option. Note that the downscale shunt option results in a negative span signal
value.
NOTE
For older SMART bridge modules, the resistor to shunt across is fixed at production.

Hardware Configuration
Click the hardware button to view the SMART module user data parameters as they
are defined in the hardware setup configuration. Note that TCE does not update
reprogrammed SMART modules until a hardware query is performed.
6.4.2 SMITC (Thermocouple SMART Module)
NOTE
The eDAQ uses the full-scale min and max values defined in the EHLS parent channel
to configure the converter that outputs analog voltage as a function of computed
thermocouple temperature. To optimize the temperature measurement accuracy, set
the full-scale values as close as possible to the temperature extremes expected in the
test.

Thermocouple Type
Select the type of thermocouple as T, J, K or E. If the channel is calibrated, delete the
calibration before selecting a different thermocouple type.
Hardware Configuration
Click the hardware button to view the SMART module user data parameters as they
are defined in the hardware setup configuration. Note that TCE does not update
reprogrammed SMART modules until a hardware query is performed.
6.5 Temperature Input Channels
6.5.1 Thermocouple
Add a thermocouple input channel to any ENTB connector. For more information on
the ENTB layer, see ENTB (Non-Isolated Thermocouple Layer) on page 104.
Output Data Type
The output data type is always 32-bit float.
Thermocouple Type
Select the type of thermocouple as T, J, K, E, or thermocouple undefined.
I2740-2.1 en 135
SoMat eDAQ
Replace Lost Data Samples
Set this field to yes to fill the data samples with a fixed value of +1.0e+06 when the
input voltage to an input channel is out of the thermocouples operating range. The
most common cause for this is a broken thermocouple or not having a thermocouple
plugged into the front panel input connector.
NOTE
Both lost data samples and out of range data samples are flagged as invalid in the test
run pipe frames (i.e., the frames of data that are passed to the computed channel and
DataMode modules). This allows the Valid Data Gate computed channel to keep track
of all invalid data samples. For more information on the Valid Data Gate computed
channel, see Valid Data Gate on page 171.

6.5.2 Isolated Thermocouple
Output Data Type
The output data type is always 32-bit float.
Replace Lost Data Samples
Set this field to yes to fill the data samples with a fixed value of +1.0e+06 when the
input voltage to an input channel is out of the thermocouples operating range. The
most common cause for this is a broken thermocouple or not having a thermocouple
plugged into the front panel input connector.
NOTE
Both lost data samples and out of range data samples are flagged as invalid in the test
run pipe frames (i.e., the frames of data that are passed to the computed channel and
DataMode modules). This allows the Valid Data Gate computed channel to keep track
of all invalid data samples. For more information on the Valid Data Gate computed
channel, see Valid Data Gate on page 171.

6.6 Bus-Oriented Input Channels
Each bus interface supports channels created from channel databases. Each channel
in the database has pre-defined parameter values which are automatically transferred
to the created channel. The bus-oriented input channels are:
Serial bus - Add up to 128 serial bus channels to the serial bus connection on
the base processor layer. For more information on the serial bus input, see
Serial Bus on page 96.
GPS - Add up to 128 GPS channels to an ECOM or EDIO GPS receiver. For
more information on the GPS receivers, see EGPS-5HZ (SoMat GPS
Receiver) on page 108 or EGPS-200 (Precision GPS Module) on page 109.
Vehicle bus - Add up to 254 vehicle bus channels to either a vehicle bus module
(VBM) compatible with an ECOM or EDIO layer or an EHLB with vehicle bus
capability. For more information on VBMs, see Vehicle Bus Module on
page 110.
SoMat eDAQ
136 I2740-2.1 en
6.6.1 Common Bus Channel Parameters
NOTE
All bus-oriented input channels for any given connector must have the same sample
rate.

NOTE
The connector parameter has no physical significance, but is a required parameter.

Enable Active Querying (serial and vehicle bus only)
Specify whether or not to use active querying.
Desired Rate (serial and vehicle bus only)
Set the query rate if active querying is in use. The limit on the query rate is a function
of multiple parameters including the type of bus and the amount of broadcast data
making it necessary to investigate this limit on a case-by-case basis.
Most active query requests are for packets that contain more that one bus channel. If
the active query rate is equal for a set of channels with the same request value, the
eDAQ ensures that the request is generated at the specified rate. If different query
rates are specified for the channels in the set, the eDAQ sets the actual query rate as
the maximum of the specified query rates.
NOTE
Use the active querying master control setting in the hardware configuration dialog to
disable or limit active querying.

NOTE
There is a limit to the amount of active querying which is a function of multiple
parameters including the type of bus and the amount of data broadcast on the bus. It
is recommended to investigate this limit on a case-by-case basis.

I2740-2.1 en 137
SoMat eDAQ
Stale Data Expiration
Set the data expiration time period in seconds. If the specified time elapses before the
receipt of a data update on the input channel, the eDAQ flags the data as invalid.
NOTE
If the expiration time period is less than the sample rate period, the eDAQ overrides
the value and sets it such that the data will not expire in one sample period or less.

Invalid Data Output Value
Set the value to substitute for any data flagged as invalid. If the data type is 32-bit float,
the substitution value can be any floating point value; otherwise, the substitution value
must be in the range of the full range min and max values specified for the channel in
the database definitions.
Bus channel inputs can be invalid for a number of reasons. The data may be marked
as invalid when the eDAQ interface receives the data (e.g., the data may not be
available at the source, the data may be marked as out of range at the source, etc.).
NOTE
The invalid value is defined in terms of the raw signal units as specified in the database
definition. Subsequently scaling the output (e.g., by using calibration definitions that
convert units) also scales the invalid value accordingly.

Raw Data Type
The raw data type is typically the data type defined in the database (i.e., 8-bit
unsigned, 16-bit unsigned or 32-bit unsigned). However, for database bit sizes other
than 8, 16 or 32, the eDAQ promotes the raw data type to one of these three bit
lengths. For example, a 1-bit unsigned is promoted to 8-bit unsigned and a 24-bit
unsigned is promoted to 32-bit unsigned.
Convert Raw Data to 32-Bit Float
Select the convert option to set the output data type to 32-bit float. The conversion
adds some computational overhead, but this is relatively insignificant to overall eDAQ
performance at the low sample rates typically used for bus inputs.
6.6.2 Vehicle Bus Message Channel
Use vehicle bus message channels to acquire raw vehicle bus packets. After selecting
the desired channel type, complete the ID, connector and description fields. For more
information on vehicle bus message channels, see Vehicle Bus Message on
page 111.
SoMat eDAQ
138 I2740-2.1 en
6.7 Network Camera Input Channel
Use the network camera message channel to acquire input from an Axis network
camera. The camera must be properly configured as outlined in Network Camera
Configuration on page 113.
NOTE
To find the channel configuration options specific to the network camera, click the
Message Channel Specifics button on the channel configuration window.

NOTE
To view the captured images in InField add the camera input channel to a Time History
DataMode. For more information on viewing the data in InField, refer to the Axis
Network Camera Devices Quick Start Guide.

Output Data Type
The output data type is always 8-bit unsigned message. Use the message logger
DataMode to store message data. For more information on the message logger, see
Message Logger on page 180.
Size
Select the size in pixels of the recorded images as one of six standard image sizes
from 160 by 120 to 640 by 480 pixels. The default size value is 640 by 480 pixels.
Compression
Set the percent compression for the camera JPEG images to between 0 and 100%.
The default compression value is 60%.
Frame Rate
Set the frame rate in hertz to the maximum camera images per second stored by the
eDAQ. The frame rate must be between 1 and 30 Hz. The default frame rate value is
30 Hz.
NOTE
The frame rate as set is the maximum frame rate. The actual frame rate may vary
depending on network efficiency, eDAQ load and the size and compression settings.
Changing the size and compression values may allow the eDAQ to achieve the
maximum frame rate. On an unloaded eDAQ with no network problems, the default
camera message channel settings produce a true 30-Hz frame rate.
I2740-2.1 en 139
SoMat eDAQ

NOTE
When using a Time History DataMode to enable plotting in Infield, ensure that the
Time History sample rate is higher than the camera frame rate. For the maximum
frame rate of 30 Hz, the Time History sample rate must be at least 100 Hz and is
recommended to be 500 Hz or higher.

6.8 Simulation Input Channels
Use a simulation transducer to simulate transducer input into the eDAQ. This type of
transducer is independent of the signal conditioning hardware on the eDAQ.
Simulation transducers are used extensively in the product development cycle at
HBM, primarily to test computed channel and DataMode functionality. There are two
types of simulation transducers available.
NOTE
The full-scale min and max values are required only if the simulation transducer data
is stored in an integer format DataMode (i.e., 16-bit or 8-bit storage modes).

6.8.1 Simulation File
The file-based simulation transducer provides the capability to simulate input based on
an ASCII file definition of the data stream allowing completely arbitrary input data
streams. Because TCE reads the ASCII file using a C fscanf() function in float
format, the data entries must be separated by white space only. There is no limit on
the number of points, however be aware that the data points are stored in the eDAQ
RAM disk consuming data storage memory.
Example Simulation Files
The following examples define the same data stream but use white space differently.
Example 1:
-100.0 500.0 -700.0 300.0
Example 2:
-100.0
500.0
-700.0
300.0

Output Data Type
Select an output data type of 8-bit integer, 16-bit integer or 32-bit float.
SoMat eDAQ
140 I2740-2.1 en
File Name
Specify the full path name of the desired ASCII input file. Use the Browse button to
select the desired file. Use the Check File option to parse the ASCII file and verify that
the format is valid.
NOTE
Because TCE parses the ASCII file at test initialization, any changes to the file prior to
initialization are effective for subsequent test runs.

Cycles
Set the value used to define the number of continuous cycles (i.e., passes through the
file) to output. After the outputting the specified number of cycles, the eDAQ repeatedly
outputs the last data value in the file.
Scale
Set the value used to scale the data values as defined in the file on a point-by-point
basis.
Offset
Set the value used to offset the data values as defined in the file on a point-by-point
basis.
Decay
Set the value used to adjust the scale value on a pass by pass basis. The scale factor
is multiplied by the decay factor on each successive pass, which results in an
exponential decay of the signal if the decay factor is a positive fraction. Note that the
default value of one results in a consistent signal from pass to pass with no decay.
Drift
Set the value used to adjust the offset value on a pass by pass basis. The drift factor
is added to the offset value on each successive pass. Note that the default value of
zero results in a consistent signal from pass to pass with no drift.
6.8.2 Simulation Function Generator
The function generator (FG) based simulation transducer provides capabilities similar
to a conventional analog function generator, i.e., a choice of various waveforms with
frequency, range and mean level control, plus some extended capabilities.
Output Data Type
Select an output data type of 8-bit integer, 16-bit integer or 32-bit float.
Function
Use the pick list to select the basic waveform shape of either sine, triangle or square.
Note that the triangle and square waveforms start at the minimum signal level
(assuming the signal is not inverted) and the sine waveform starts at the mean signal
level. For all waveforms, the peak to peak limits are 1.0 prior to the application of the
user defined scale and offset values.
I2740-2.1 en 141
SoMat eDAQ
Period
Set the waveform period in terms of the number of samples. The waveform frequency
(in Hz) is defined as the sample rate divided by the period. For example, a period of
100 samples at a sample rate of 1000 results in a 10 Hz signal.
Duty Cycle
Set duty cycle in percent for triangle and square waveforms modes only. The default
value of 50% produces symmetric waveform shapes. Assuming the signal has not
been inverted, the duty cycle represents the percentage of time that the square
waveform is in the low state or the percentage of time that the triangle waveform is in
the ramp up state.
Cycles
Set the value used to define the number of continuous cycles (i.e., passes through the
file) to output. After the outputting the specified number of cycles, the eDAQ repeatedly
outputs the last data value in the file.
Scale
Set the value used to scale the data values as defined in the file on a point-by-point
basis.
Offset
Set the value used to offset the data values as defined in the file on a point-by-point
basis.
Decay
Set the value used to adjust the scale value on a pass by pass basis. The scale factor
is multiplied by the decay factor on each successive pass, which results in an
exponential decay of the signal if the decay factor is a positive fraction. Note that the
default value of one results in a consistent signal from pass to pass with no decay.
Drift
Set the value used to adjust the offset value on a pass by pass basis. The drift factor
is added to the offset value on each successive pass. Note that the default value of
zero results in a consistent signal from pass to pass with no drift.
6.8.3 Simulation Message
Output Data Type
The output data type is always 8-bit unsigned message.
Format
Select either an ASCII or binary message format. The ASCII format pouts a repeating
pattern of the 26 letters from A to Z. The binary format outputs a repeating pattern of
byte values from 0 to 255.
Message Size
Specify the message size in bytes.
Message Interval
Specify the period in seconds for repetitive generation of the simulated message.
SoMat eDAQ
142 I2740-2.1 en
I2740-2.1 en 143
SoMat eDAQ
7 Computed Channels
This chapter details the available computed channels and their associated
parameters. A computed channel is a data channel derived from one or more
transducer channels or from previously defined computed channels. For example, a
computed channel can generate a channel having a higher or lower sample rate (using
Up Sampler or Down Sampler), be constructed from data using a mathematical
formula or expression (using the Desk Calculator) or integrate data samples (using the
Integrator). Define computed channels in the computed channel setup window.
NOTE
Defining computed channels in a test setup is optional

7.1 Common Computed Channel Parameters
The following parameters are common to all computed channels.
Network Node
This field displays the IP address or host name of the eDAQ for which the channel has
been defined.
ID
Enter a unique identifier for the channel. The name must conform to ID naming
conventions. Valid ID names:
are case sensitive
are limited to a maximum of 12 characters
contain only valid characters (i.e., letters (a-z, A-Z), digits (0-9), and the
underscore (_) character)
start with a letter
are not duplicates of system reserved names (sin, cos, log, etc.)
Description
Enter a more detailed description of the computed channel. TCE sets the description
field to match the input channel description, but modifications are permitted.
Type
Define the type of measurement associated with the transducer or computed channel.
Typical types include strain, load and acceleration. Select a type from the list or directly
key in a user-defined type. Since TCE uses the type definition in subsequent sections
of the test setup process, completing the field is recommended.
Units
Define the units of measurement for the computed channel. Since TCE uses the units
definition in subsequent sections of the test setup process, completing the field is
recommended.
SoMat eDAQ
144 I2740-2.1 en
Input Channel
Select the desired input channel(s) to the computation. The number of input channels
permitted depends on the computed channel type.
Output Data Type
Depending on the channel type, the eDAQ provides several data type options. When
choosing the data type, consider factors such as data resolution, mass storage
consumption and what computed channels or DataModes use the channel as an
input. For a summary of the compatible data types for all computed channels and
DataModes, see Data Types on page 203.
Full-Scale Min and Max
The min and max full-scale fields define the expected extreme values of the computed
channel expression. When storing a 32-bit float in a DataMode that uses an integer
data type, the eDAQ uses the full-scale limits when converting from the floating point
format to the integer format. The eDAQ also uses the full-scale estimates to set the
default values for any histograms specified in the test setup DataModes.
7.2 Arithmetic Computed Channels
7.2.1 Desk Calculator
Desk Calculator computed channels generate data streams of either arithmetic
(floating point) or logical (Boolean) results.
Input Channel
All input channels to a single Desk Calculator channel must have the same sample
rate, which also determines the computed channel sample rate. The required input
data types for the Desk Calculator operator set are listed in table below.
NOTE
The time functions (e.g., _utc_day()) require an input from a Time Channel computed
channel with a 32-bit float data type (see Time Channel on page 164).

Output Data Type
The output data types for the Desk Calculator operator set are listed in the table above.
Operator Input Type Output Type
sin, cos, tan, asin, acos, atan,
log, log10, abs, exp, sgn,
round, floor, ceil, +,-,*,/,%,^
32-bit float 32-bit float
float 8-bit unsigned 32-bit float
>,>=,<,<=,==,!= 32-bit float 8-bit unsigned
!,&&,|| 8-bit unsigned 8-bit unsigned
time functions 32-bit float Time
Channel
32-bit float
I2740-2.1 en 145
SoMat eDAQ
Desk Calculator Expression
Build the Desk Calculator expression using keyboard entry or by double clicking an
input channel or operation to add it to the expression. Syntax for the Desk Calculator
expression is modeled after the standard C programming language and follows the
same operator precedence rules. All operators and referenced input channels are
case sensitive. Operand data type consistency is strictly enforced in the parsing of the
Desk Calculator expression operators. TCE warns of any syntax errors it detects after
clicking OK.
Floating point exceptions can occur with the misuse of certain Desk Calculator
operators such as taking the square root or logarithm of a negative number. When
detecting these exceptions, the eDAQ sets the MathException status flag. The results
of such operations are usually some form of IEEE NAN (not a number).
Category Operator Syntax Return
Arithmetic abs abs(a ) The absolute value of a .
sqrt sqrt(a ) The square root of a .
log log(a ) The natural logarithm of a .
log10 log10(a ) The base-10 logarithm of a .
exp exp(a ) The exponential function of a .
sgn sgn(a ) -1 for a < 0, 1 for a > 0 and 0 for a = 0.
float float(a ) a in floating point data type.
round round(a ) The nearest integer to a .
floor floor(a ) The largest integer less than a .
ceil ceil(a ) The smallest integer greater than a .
^ a ^b a raised to the power of b .
* a *b The product of a and b .
/ a /b The quotient of a and b .
% a %b The modulus of a and b .
+ a +b The sum of a and b .
- a -b The difference of a and b .
Trigonometric
(all angles in radians)
sin sin(a ) The sine of a .
cos cos(a ) The cosine of a .
tan tan(a ) The tangent of a .
asin asin(a ) The arcsine of a in the range [-PI/2, PI/2].
acos acos(a ) The arccosine of a in the range [0, PI].
atan atan(a ) The arctangent of a in the range [-PI/2, PI/2].
SoMat eDAQ
146 I2740-2.1 en
NOTE
The second time functions can return a value of 60 which indicates the rare case of a
leap second. The resulting time sequence in this case is 23:59:59, 23:59:60,
00:00:00.
Logical > a >b TRUE if a is greater than b ; else FALSE.
>= a >=b TRUE if a is greater than or equal to b ; else FALSE.
< a <b TRUE if a is less than b ; else FALSE.
<= a <=b TRUE if a is less than or equal to b ; else FALSE.
== a ==b TRUE if a is equal to b ; else FALSE.
!= a !=b TRUE if a is not equal to b ; else FALSE.
! !a TRUE if a is FALSE; else FALSE.
&& a &&b TRUE if a and b are TRUE; else FALSE.
|| a ||b TRUE if either a or b are TRUE; else FALSE.
Time
(input must be a Time
Channel)
_utc_subsecond _utc_subsecond(a ) The subsecond (0-1) in UTC.
_utc_second _utc_second(a ) The second (0-60) in UTC.
_utc_minute _utc_minute(a ) The minute (0-59) in UTC.
_utc_hour _utc_hour(a ) The hour (0-23) in UTC.
_utc_day _utc_day(a ) The day (1-31) in UTC.
_utc_month _utc_month(a ) The month (1-12) in UTC.
_utc_year _utc_year(a ) The year in UTC.
_utc_day_week _utc_day_week(a ) The day of the week (1-7) in UTC.
_utc_day_year _utc_day_year(a ) The day of the year (1-366) in UTC.
_local_subsecond _local_subsecond(a ) The subsecond (0-1) in local time.
_local_second _local_second(a ) The second (0-60) in local time.
_local_minute _local_minute(a ) The minute (0-59) in local time.
_local_hour _local_hour(a ) The hour (0-23) in local time.
_local_day _local_day(a ) The day (1-31) in local time.
_local_month _local_month(a ) The month (1-12) in local time.
_local_year _local_year(a ) The year in local time.
_local_day_week _local_day_week(a ) The day of the week (1-7) in local time.
_local_day_year _local_day_year(a ) The day of the year (1-366) in local time.
Category Operator Syntax Return
I2740-2.1 en 147
SoMat eDAQ

NOTE
The subsecond time functions return the fractional part of a second at a resolution
dependent on the sample rate of the Time Channel input. For example, a sample rate
of 100 Hz results in a resolution of 0.01 seconds and a sample rate of 1000 Hz results
in a resolution of 0.001 seconds.

Application Note: Piecewise Linear Relationships
In the following example, the desired output of the Desk Calculator channel (y ) is defined as follows, based on the value of
the input channel (x ).
The first step is to define the required set of logical Desk Calculator channels (s1, s2, s3, s4) as follows:
s1: x>10e0
s2: x>50 && x<=100
s3: x>0 && x<=50
s4: x<=0
The second step is to define the required set of arithmetic Desk Calculator channels (y1, y2, y3, y4) as follows:
y1: 2.1*x+100
y2: 2.2*x+90
y3: 2.3*x+80
y4: 2.4*x+70
The third step is to define the final Desk Calculator channel (y) as follows :
y: y1*float(s1)+ y2*float(s2)+ y3*float(s3)+ y4*float(s4)
Note that it is not necessary to define the intermediate variables and, in fact, it is less efficient from a processing point of view
to use intermediate variables when they are not used more than once in the set of computed channels. However, they have
been used above to clarify the general approach.

7.2.2 Engineering Scaler
The Engineering Scaler channel generates a 32-bit float output channel scaled to
engineering units from an integer data type input channel.
Input Channel
The input channel data type must be 8-bit integer, 8-bit unsigned, 16-bit integer, 16-bit
unsigned, 32-bit integer, or 32-bit unsigned.
Output Data Type
The output channel data type is 32-bit float.
7.2.3 Integer Scaler
The Integer Scaler channel generates an integer data type output channel from any
32-bit float input channel.
SoMat eDAQ
148 I2740-2.1 en
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output data type must be 8-bit integer, 8-bit unsigned, 16-bit integer, 16-bit
unsigned, 32-bit integer, or 32-bit unsigned.
7.2.4 Integrator
The Integrator channel generates an output channel that is the integral of the input
channel. As long as the integrator is not reset or suppressed, each output channel
sample is the cumulative sum of the current and all previous input channel samples
multiplied by a user-defined scale factor and added to a user-defined initial value.
A logical channel set as a trigger can reset the integrator or suppress integration. The
integrator can also reset when exceeding a user-defined summation value.
Input Channel
The input channel data type must be 32-bit float, 32-bit integer or 32-bit unsigned.
Output Data Type
The output data type is the same as the input channel data type.
Integrate Only When TRUE
Select the integrate only when TRUE option to suppress integration when the trigger
channel is FALSE.
Enable Triggered Reset
Select the enable triggered reset option to reset the integrator to the initial value when
the trigger channel satisfies the defined condition.
Trigger Channel
Specify the input channel used for the reset enable or sum on trigger options.
Reset Mode
Select how to use the specified trigger channel for the reset enable option. The
available trigger condition options are below.
NOTE
When using the sum on trigger option, the trigger condition is limited to on a TRUE to
FALSE edge.

Reset Mode Description
When TRUE Reset when the trigger channel is TRUE.
On FALSE-TRUE edge Reset when the trigger transitions from FALSE to TRUE.
On TRUE-FALSE edge Reset on the sample after the trigger channel transitions from
TRUE to FALSE. If the sum on trigger option is not selected, then
the output sample after the TRUE to FALSE edge is the sum of
the initial value and the scaled input sample.
I2740-2.1 en 149
SoMat eDAQ
Reset on Sum Exceed
Select the reset on sum exceed option to reset the integrator to the initial value when
the absolute value of the integrator sum exceeds the value specified in the sum exceed
value field.
NOTE
If using the reset on sum exceed option, the eDAQ does not allow any other trigger or
reset options.

Initial Value
Specify the value for the integration sum at the start of each run and on a reset if using
the reset enable option.
NOTE
For an input data type of 32-bit unsigned or 32-bit signed, the initial value is fixed at
zero.

Scale Factor
Specify the value to scale each input sample before adding it to the previous
integration sum. Setting the scale factor to the sample period results in the time
integral of the input channel.
NOTE
For an input data type of 32-bit unsigned or 32-bit signed, the scale factor is fixed at
one.

Use 64-bit Float for Sum
Select the 64-bit float for sum option to ensure that the integration is not subject to the
inherent limitations of using a 32-bit float to accumulate the integration sum. This is
particularly critical for long term or high sample rate testing where relatively small
values are added to an ever increasing sum. It is strongly recommended to use the
64-bit float for sum option whenever possible.
SoMat eDAQ
150 I2740-2.1 en
Using the Integrator to Measure Accumulated Pulse Counts
The use of the Integrator computed channel to yield accumulated counts varies based on the selected output data type.
32-Bit Unsigned: The most efficient way to use the Integrator computed channel is with this data type; the integrator
can then accumulate up to 4294967295 counts. This is the suggested approach for simply counting pulses or events.
The scaling to hertz is performed by an associated scale factor used only when needed, such as for DataMode storage.
Therefore, the output data stream is the stream of unsigned integer counts.
32-Bit Float: If the this output mode is used, then the scale factor field in the Integrator should be set to the reciprocal
of the pulse counter sample period to yield counts; additional scaling can be incorporated into the scale factor field for
conversion to distance, revolutions, etc. It should also be kept in mind that a 32-bit float can only accumulate about 16.7
million counts before it saturates as an integral counter. The scaling to hertz is performed on a sample-by-sample basis
as the data is acquired.
For more information on pulse counter inputs, see Pulse Counter on page 121.

7.2.5 Pulse Counter
The Pulse Counter computed channel is used to measure pulse frequencies primarily
in conjunction with digital inputs. Each FALSE to TRUE transition signifies the end of
a pulse period and initiates an update of the current pulse frequency, which is output
at a user-defined rate. The pulse counter frequency also updates if the time period
since the last transition exceeds the current pulse counter frequency output, resulting
in improved response as the pulse train slows or stops.
NOTE
The current pulse frequency initializes to 0 Hz and remains at this initial value until two
FALSE to TRUE transitions occur.

The accuracy of the pulse frequency measurements is dependent on the sample rate
of the digital input channel only (i.e., it is not dependent on the output sample rate
which is set indirectly by the factor parameter). For example, using an input channel
sampled at 2000 Hz provides 1% accuracy of a 20 Hz pulse signal or 0.1% accuracy
of a 2 Hz pulse signal. As a rule of thumb, the input sample rate should be 100 times
the maximum expected pulse frequency to provide 1% or better accuracy over the
entire range of pulse frequency content.
Input Channel
The input channel data type must be 8-bit unsigned (logical).
Output Data Type
The output channel data type is 32-bit float.
Output Rate Factor
Specify the desired down sample factor which sets the output sample rate based on
the sample rate of the input channel. For example, if the input channel sample rate is
2000 Hz, a factor of 100 results in an output sample rate of 20 Hz.
Cal Scale Factor
Specify the desired scale factor for converting measured pulse frequency in Hz to the
desired engineering units.
I2740-2.1 en 151
SoMat eDAQ
Minimum Frequency Limit
Specify the desired minimum frequency limit for the Pulse Counter. If there is no new
pulse within the period (1/f
min
), the channel outputs this frequency value.
NOTE
The minimum frequency limit parameter provides a solution when a pulse train stops.
For example, if a 50 Hz pulse train stops, the Pulse Counter output remains at 50 Hz
until there is a new pulse frequency.

7.2.6 Directional Velocity
The Directional Velocity channel generates a signed velocity output from two input
channels. One input channel is the unsigned velocity; the second input channel is a
position channel and sets the sign of the output channel.
The sign of the output channel is determined from the position channel as follows. If
the position on the current data sample is greater than the position on the previous
data sample, the sign is positive. If the position on the current data sample is less than
the position on the previous data sample, the sign is negative. If the position on the
current data sample is equal to the position on the previous data sample, the sign
retains its current value.
Input Channel
The velocity input channel data type must be 32-bit float. The direction input channel
data type must be either 32-bit float or 32-bit integer.
Output Data Type
The output channel data type is 32-bit float.
NOTE
It is strongly recommended that the direction input channel have a data type of 32-bit
integer, which is the raw data type of the quadrature decoder Pulse Counter channel.
Using a 32-bit float works only if the quadrature decoder output stays in the
approximate range of +/- 16000000 counts. The 32-bit integer data type allows use of
the full range of the quadrature decoder pulse channel of +2147483647 to
-2147483648 counts.

Check for Int32 Rollover
If the direction input channel is a 32-bit integer channel, use the int32 rollover check to
detect rollover of the signed 32-bit counter. If the counter jumps by more than
24000000 counts from one sample to the next, the eDAQ assumes that the counter
has rolled over. For example, if the counter jumps from +2100000000 to -2140000000,
the eDAQ detects a rollover and sets the sign to positive.
NOTE
Use the rollover check option on an as-needed basis as it does add some processing
overhead to the channel.
SoMat eDAQ
152 I2740-2.1 en

Pulse Counter Application Note: Quadrature Encoder
This Directional Velocity channel was developed primarily to provide a signed RPM output channel using a quadrature
encoder connected to a EDIO layer. Configure one of the two pulse trains from the quadrature encoder as a pulse frequency
transducer channel to yield the unsigned velocity input channel. Define a normal quadrature decoder Pulse Counter channel
using both pulse trains to yield the position input channel. For more information on quadrature encoder inputs, see Pulse
Counter on page 121.

7.2.7 State Mapper
The State Mapper channel maps the input channel into a discrete state output channel
based on a set mapping conditions defined in an ASCII file. Define each mapping
condition in terms of a minimum input value, a maximum output value, and the
associated output state value. The number of mapping conditions must be 32 or less.
The ASCII file should be a line-based file with the three ordered entries per line
separated by spaces or tabs.
NOTE
The State Mapper channel can consume significant eDAQ computational resources
depending on the sample rate and the number of mapping conditions defined.

State Mapper Example: Angular Position
Consider mapping an input channel that generates angular position in the range of 0 to 360 degrees into an output channel
that specifies which 60 degree sector the input channel is in. Use the following mapping conditions where x is the input and
y is the output.
One way to write the ASCII file for this example is as follows.
0 60 1
60 120 2
120 180 3
180 240 4
240 300 5
300 360 6

Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output channel data type is 32-bit float.
I2740-2.1 en 153
SoMat eDAQ
ASCII File
Specify the full path name of the ASCII file that defines the mapping conditions. Use
the Browse button to select the desired file. Use the Check File option to parse the
ASCII file and verify that the format is valid.
NOTE
Because TCE parses the ASCII file at test initialization, any changes to the file prior to
initialization are effective for subsequent test runs.

Use Default Output
Select the default output option to output a default value when the input channel does
not meet any of the mapping conditions. If not selected, the output remains in its
existing state.
Default Out
Specify the default value for the output. The channel outputs the value if the first input
sample does not meet any mapping conditions. Also, when using default out, the
channel outputs the default value throughout the test run when the input does not meet
any mapping conditions.
Latch Period
Specify the time in seconds that the input channel must consistently map to the same
output state before the output state switches. The latch period is similar to a duty cycle
on the output state preventing the output state from switching for at least this period of
time. This feature can eliminate state switching transients in the output channel data
stream. If the latch period is 0.0, then the output state switches on each sample.
7.2.8 Statistical Analysis
The Statistical Analysis channel generates statistical output data from source
transducer or computed channel input data.
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output data type is 32-bit float.
Statistic
Select one of six available statistical modes. The following table defines the algorithms
used to compute the statistical values where N is the number of data samples in the
analysis window and X
mean
is the mean of the data in the analysis window.
SoMat eDAQ
154 I2740-2.1 en
Percentile
Specify the X value for the Xth-percentile mode. The value can be an integer between
0 and 100.
NOTE
Setting the Xth-percentile parameter to zero returns the minimum value in the analysis
window. Setting the Xth-percentile parameter to 100 returns the maximum value in the
analysis window.

Window Samples
Specify the number of input samples used to generate one output sample. This sets
the analysis window size and associated output sample rate. Specify any positive
integer value greater than one.
Statistic Algorithm
Mean

Standard deviation

RMS

Kurtosis

Skewness

Xth-percentile TCE sorts the data samples in the analysis window in ascending order
and interpolates as required between the array element data values
that border the exact Xth-percentile array element. For more
information on processing limitations when using the Xth-percentile
mode, see Xth-Percentile Benchmark Tests on page 251.
I2740-2.1 en 155
SoMat eDAQ
7.2.9 Damage Equivalent Load
The Damage Equivalent Load channel generates an accumulated equivalent load
range value as a function of the user-defined damage slope parameter and the
associated accumulated rainflow cycle count for the selected input channel.
NOTE
The Damage Equivalent Load channel has two outputs, load and cycle, each of which
has its own name, description, type, units, full-scale min and max, and data type fields.

The eDAQ processes the input channel through a rainflow cycle counter using the
user-defined hysteresis value for peak picking. For each closed cycle, the eDAQ
computes a load damage parameter as (closed cycle range ^ damage slope) and
adds it to the running sum that accumulates load damage on a cycle-by-cycle basis.
For each output sample, the eDAQ processes the residual peak-valley sequence
through the rainflow cycle counter to account for the additional accumulated load
damage and accumulated closed cycle counts. The Damage Equivalent Load output
value (Seq ) is computed using the following equation:
where, x
i
is the load damage for each closed cycle, N is the number of closed cycles
and m is the damage slope.
For more information on the data processing algorithms used, see Data Processing
Algorithms on page 253.
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
Both output channel data types are 32-bit float.
Hysteresis
Set the desired hysteresis level for the peak valley processing algorithm.
Damage Slope
Set the damage slope used in the processing algorithm as described above. This can
be any value from 1.0 to 20.0.
Window Samples
Specify the number of input samples used to generate one output sample. This sets
the analysis window size and associated output sample rate. Specify any positive
integer value greater than one.
NOTE
There can be fairly significant computational overhead in generating each output
sample, particularly when the residual peak-valley sequence is relatively long (i.e., 100
residual peak-valleys or more). Consider the computational overhead when specifying
the window samples.
SoMat eDAQ
156 I2740-2.1 en

Application Note: Load-Life Fatigue Damage
If the input channel is a linear function of load, the outputs of this channel can translate to a simple load-life fatigue damage
assessment for the test run. For example, assuming that a load-life relationship is given by
where, N
f
is the constant load range cycles to failure, S
o
is the load range when N
f
equals 1 and m is the damage slope.
Assuming that S equals the product of some coefficient k and the input channel, it follows that the fractional fatigue damage
per block (i.e., per test run), 1/B
f
, is given by
Note that load-life relationships are most typically defined in terms of load amplitude versus cycles to failure, instead of in
terms of load range versus cycles to failure as in the above example.

7.2.10 Fatigue Damage
The Fatigue Damage channel generates an output stream of fatigue damage for the
selected input channel. The fatigue damage computations are based on the selected
fatigue damage model, material parameters and on optional input and output scaling
parameters.
Scaling the input channel can be useful, for example, in converting transducer data in
microstrain units to dimensionless strain units required for the fatigue processing
models. TCE processes the optionally scaled input channel on a point-by-point basis
through a rainflow cycle counter using the user-defined hysteresis value for peak
picking. For each closed cycle, the computed fatigue damage is added to the running
sum of cumulative fatigue damage based on the user-selected fatigue damage model.
For each output sample, the residual peak-valley sequence is processed through the
rainflow cycle counter to account for the additional accumulated fatigue damage. The
output values are effectively scaled based on the user-selected damage units option.
NOTE
The use of the scaling options does not result in any processing overhead because of
the way that these parameters are integrated into the fatigue damage solvers.

For more information on the data processing algorithms used, see Data Processing
Algorithms on page 253.
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output channel data type is 32-bit float.
I2740-2.1 en 157
SoMat eDAQ
Scale Factor
Specify the desired scaling factor typically used to convert the input channel data into
the proper units based on the damage model. For example, the scale factor converts
input channel data in microstrain units to dimensionless strain units when using the
strain-life damage model.
Sum Damage Only When TRUE
Select the sum damage only when TRUE option to filter out input data samples that
are not to be used in the fatigue damage accumulation processing.
Trigger Channel
Specify the trigger channel used in the sum on trigger feature. The trigger channel can
be any logical channel that has the same sample rate as the input channel.
Accumulate Across Test Runs
The accumulate across test runs option is not currently supported.
Damage Model
Select one of three available damage models. The following table defines each model
in terms of a log
10
-log
10
linear relationship.
SoMat eDAQ
158 I2740-2.1 en
NOTE
These basic damage models do not provide any corrections for the mean values of the
load ranges affecting the cumulative damage.

NOTE
Existing material databases may be defined in terms of either reversals to failure (2N
f
),
load amplitude (P/2) or stress amplitude (S/2). Convert to the required parameters as
necessary.

Model Description
Load-Life The load-life relationship is defined by
where N
f
is cycles to failure, P is the applied load range and P
o
and b
are, respectively, the user-defined intercept and slope of the
log
10
-log
10
function.
For each rainflow cycle, the damage, 1/N
f
, computed from the load
range, P, is added to the cumulative damage sum.
Stress-Life The stress-life relationship is defined by
where N
f
is cycles to failure, S is the applied stress range and S
o
and
b are, respectively, the user-defined intercept and slope of the
log
10
-log
10
function.
For each rainflow cycle, the damage, 1/N
f
, computed from the stress
range, S, is added to the cumulative damage sum.
Strain-Life The strain-life relationship is defined by
where 2N
f
is reversals to failure, e
l
is elastic strain amplitude and S
f
/E
and b are, respectively, the user-defined intercept and slope of the
log
10
-log
10
function;
where e
p
is plastic strain amplitude and e
f
and c are, respectively, the
user-defined intercept and slope of the log
10
-log
10
function; and
where e is the total strain amplitude.
For each rainflow cycle, the damage per cycle, 2/2N
f
, computed from
the stress range, 2e, is added to the cumulative damage sum.
I2740-2.1 en 159
SoMat eDAQ
Edit Model Parameters
Depending on the model selected, several parameters used in the computation are
available for modification by clicking the Edit Model Parameters button. The following
table lists the available model parameters and their corresponding variables in each
damage model.
NOTE
TCE accumulates no damage if the applied load or stress range is less than the fatigue
limit parameter.

Hysteresis
Specify the desired hysteresis level for the peak valley processing algorithm.
Damage Units
Select the desired output channel damage units. The available units are damage,
percent life or microdamage. Note that the output channel full-scale estimates are
automatically assigned based on this selection.
Window Samples
Specify the number of input samples used to generate one output sample. This sets
the analysis window size and associated output sample rate. Specify any positive
integer value greater than one.
NOTE
There can be some fairly significant computational overhead in generating each output
sample, particularly when the residual peak-valley sequence is relatively long (i.e., 100
residual peak-valleys or more). Consider this fact when setting the window samples
parameter.

7.3 Triggering Computed Channels
Trigger computed channels generate a logical channel data stream useful for
triggering DataModes or other computed channels.
Parameter Load-Life Stress-Life Strain-Life
Elastic modulus - - E
Fatigue strength coefficient P
o
S
o
S
f

Fatigue strength exponent b b b


Fatigue ductility coefficient - - e
f

Fatigue ductility exponent - - c


Fatigue limit load limit stress limit -
SoMat eDAQ
160 I2740-2.1 en
7.3.1 Interactive Trigger
The Interactive Trigger channel provides a means to trigger DataModes and computed
channels directly from TCE. Up to eight Interactive Triggers are supported. For more
information on interactive triggering, see Using Interactive Triggers on page 77.
Input Channel
The input channel sets the sample rate of the channel. All data types are supported.
Output Data Type
The output channel data type is 8-bit unsigned (logical).
Trigger Index
Set the trigger index from 1 to 8.
Invert Trigger
Select the invert trigger option to reverse the logic of the trigger.
7.3.2 Trigger Generator
The Trigger Generator channel generates a trigger channel that consists of an optional
initial delay period followed by a repetitive cycle of on (TRUE) periods and off (FALSE)
periods. The eDAQ ensures that there is at least one output sample for both the on
period and the off period.
Use a Trigger Generator channel to create an elapsed time trigger for DataModes or
other computed channels that support triggering. For example, the eDAQ can use a
generated trigger channel to store 10 minutes of data every hour. The Trigger
Generator channel is ideally suited for long-term acquisitions such as temperature
measurements of civil structures.
NOTE
The upper limit for all periods in seconds is 4.25E+09 divided by the sample rate.

Input Channel
The input channel sets the sample rate of the channel. All data types are supported.
Output Data Type
The output channel data type is 8-bit unsigned (logical).
Initial Delay Period
Specify the initial delay period in seconds. After the delay period, the output switches
to the on state. If set to zero, the output starts in the on state.
On Period
Specify the on period in seconds. The output switches to the off state after this period.
Off Period
Specify the off period in seconds. The output switches back to the on state after this
period.
I2740-2.1 en 161
SoMat eDAQ
7.3.3 Timed Trigger
The Timed Trigger computed channel generates a logical output based on a logical
input and user-defined timing parameters.
Input Channel
The input channel data type must be 8-bit unsigned (logical).
Output Data Type
The output channel data type is 8-bit unsigned (logical).
Trigger Start Mode
Select the start mode of the trigger from three available trigger start modes.
Enable Delay
Select the enable delay option to enable the delay mode.
Delay Period
When using the delay option, specify the delay period in seconds after the input
channel triggers to set the channel output. The maximum value for the delay period is
4294967295 times the sample period.
Delay Conditional Mode
Select one of three available delay modes to conditionally set the output channel state
based on the behavior of the input channel during the delay period.
Enable Sustain
Select the enable sustain option to enable the sustain mode. If not enabled, the
channel outputs TRUE for one sample before reverting to FALSE.
Sustain Period
When using the sustain option, specify the desired sustain period in seconds. The
maximum value for the sustain period is 4294967295 times the sample period.
Trigger Start Mode Description
When TRUE Start when the input channel is TRUE.
On FALSE-TRUE edge Start when the input channel transitions from FALSE to TRUE.
On TRUE-FALSE edge Start on the sample after the input channel transitions from TRUE
to FALSE.
Delay Mode Description
Unconditional Set the output to TRUE regardless of the input channel behavior
during the delay period.
If TRUE at end Set the output to TRUE if the input channel is TRUE on the last
sample of the delay period. Otherwise, the search for a new
trigger start condition begins.
If TRUE continuously Set the output to TRUE if the input channel is continuously TRUE
on all samples of the delay period. If the input channel is FALSE
at any point during the delay period, the search for a new trigger
start condition begins.
SoMat eDAQ
162 I2740-2.1 en
Sustain Conditional Mode
Select one of two available sustain modes to conditionally set the output channel state
based on the behavior of the input channel during the sustain period.
7.3.4 Triggered Zero Suppression
The Triggered Zero Suppression channel generates output channels that zero
suppress the input channel when a trigger condition is satisfied.
NOTE
The Triggered Zero Suppression computed channel is designed primarily to provide a
reset for quadrature decoder channel outputs when a triggering event occurs. For
more information on quadrature encoder inputs, see Pulse Counter on page 121.

Input Channel
The input channel data type must be 32-bit float, 32-bit integer or 32-bit unsigned.
Output Data Type
The output data type is the same as the input data type.
Trigger Channel
Select the input channel used to determine when to zero suppress the input channel
based on the trigger condition.
Trigger Mode
Select from three available trigger modes to specified the trigger channel behavior.
The available trigger mode options are below.
Suppression Value
Define the desired suppression value. The default suppression value is zero. Keep in
mind that if the input channel is a 32-bit float, the suppression value is in engineering
units, but if the input channel is either a 32-bit integer or a 32-bit unsigned, the
suppression value is in integer counts. For clarification, suppose a quadrature decoder
Sustain Mode Description
Unconditional Set the output to TRUE for the duration of the sustain period
regardless of the input channel behavior during the sustain
period.
While true Set the output channel to TRUE only while the input channel is
TRUE during the sustain period. Note that if the input channel is
FALSE when the sustain period begins, the output value will not
be set to TRUE effectively canceling the trigger. At the end of the
sustain period, the output value is set to FALSE and the search
for the next trigger start condition begins.
Trigger Mode Description
When TRUE Suppress when the trigger channel is TRUE.
On FALSE-TRUE edge Suppress when the trigger transitions from FALSE to TRUE.
On TRUE-FALSE edge Suppress on the sample after the trigger channel transitions from
TRUE to FALSE.
I2740-2.1 en 163
SoMat eDAQ
channel uses the 32-bit integer data output option, the calibration slope is defined such
that 2048 counts equals 360 degrees, and the calibration intercept is zero. To set the
desired suppression in engineering units to zero degrees, set the suppression value
to zero integer counts. However, there is no way to set the desired suppression in
engineering units to exactly 7 degrees, since 7 degrees is equivalent to 39.822 counts
which is not an integer value. To avoid this problem, set the calibration intercept to
7.0 degrees and then use a suppression value of zero.
7.3.5 Bitmap Trigger
The Bitmap Trigger computed channel produces a logical output based on the match
of the input bitmap channel and the user-specified bitmap mask. Use with an Anomaly
Detect computed channel to generated a trigger when the eDAQ detects a defined
anomaly. For more information on the Anomaly Detect computed channel, see
Anomaly Detect on page 170.
Input Channel
The input channel data type must be the output of an Anomaly Detect computed
channel, which is the only eDAQ channel with an output data type of 8-bit unsigned
(bitmap).
Output Data Type
The output channel data type is 8-bit unsigned (logical).
Bitmap Check Mode
Select the desired bitmap check mode from the two available options.
Bit Mask
Specify the desired bit mask in hexadecimal format ranging from 0x1 to 0xFF.
Invert Output Logic
Select the invert output logic option to invert the output logic defined in the bitmap
check mode. Note that using inversion can identify anomaly-marked data segments
and output a trigger stream to gate out these data segments in any desired computed
channels or DataModes.
7.3.6 Test Run Stopper
The Test Run Stopper channel stops a test run when the input channel becomes
TRUE.
NOTE
To automatically start a test run after the Test Run Stopper stops a run, use the remote
control option with the run control switch always in the run position. For more
information on remote control, see Using Remote Control Operation on page 91.
Bitmap Check Mode Description
Any bit in mask set If any bit in the specified bit mask is set, the output value is TRUE;
otherwise it is FALSE.
All bits in mask set If all of the bits in the specified bit mask are set, the output value
is TRUE; otherwise it is FALSE.
SoMat eDAQ
164 I2740-2.1 en

NOTE
The test run does not stop immediately when the input channel becomes TRUE.
Because the input channel is processed in frames that can be buffered, the test run
typically stops in a fraction of a second after the input channel becomes TRUE. In the
worst case, assume that several seconds could elapse before the test run actually
stops.

Input Channel
The input channel data type must be 8-bit unsigned (logical).
Output Data Type
The output channel data type is 8-bit unsigned (logical).
Application Note: Stopping a Test After a Defined Time Period
To stop a test run after a certain amount of run time, do the following: Define a Time Channel computed channel (see Time
Channel on page 164) and select the 32-bit float data type option. Then define a Desk Calculator computed channel (see
Desk Calculator on page 144) with an expression such as ElapsedTime >= 600, where ElapsedTime is the ID of the
Time Channel, and 600 seconds is the desired test run duration.
To limit the data stored in any DataMode to the exact test run duration specified, use the gate triggering options, using the
Desk Calculator computed channel defined above as the trigger channel.

7.4 Time, Sample Rate and Filter Computed Channels
7.4.1 Time Channel
The Time Channel provides a time base channel for use with other computed
channels or for storage in the Time History (see Time History on page 175) and
Peak/Valley Slice (see Peak Valley Slice on page 181) DataModes. For each data
sample in the selected input channel, the channel outputs the corresponding elapsed
time in seconds since the start of the test run. The first sample is at time equal to zero
seconds.
Input Channel
The input channel can be any data type.
Output Data Type
Select an output data type of 32-bit float or 32-bit unsigned.
NOTE
Time channels are unique in that the selected data type determines the data type used
in the DataModes.

I2740-2.1 en 165
SoMat eDAQ
Use 64-bit Float for Sum
Select the 64-bit float for sum option to minimize the limited precision error that results
from using the 32-bit float data type. This error becomes more significant for tests of
long duration.
7.4.2 Time Base Shifter
The Time Base Shifter channel generates an output channel that either leads or lags
the selected input channel by a user defined number of samples.
Note that the channel fills the first n+1 output samples with the initial value of the input
channel.
Input Channel
The input channel can be any data type.
Output Data Type
The output data type is the same as the input data type.
Shift Direction
Select the output channel shift direction to either lag or lead the input channel by the
specified shift count.
Shift Count
Specify the number of samples between 1 and 1000 for the output channel to lead or
lag the input channel.
7.4.3 Down Sampler
The Down Sampler channel reduces the number of samples taken from the input
channel by a user-defined factor, simulating a lower sample rate and decreasing the
amount of memory needed data storage. For example, a factor of three causes the
channel to output one out of three input samples as illustrated below.
Figure 7-1: An illustration of the Down Sampler computed channel.
NOTE
Use the Down Sampler only when data values in the input channel change slowly and
the possibility of losing significant data is minimal.

SoMat eDAQ
166 I2740-2.1 en
Input Channel
The input channel can be any data type.
Output Data Type
The output data type is the same as the input data type.
Factor
Specify the desired down sample factor.
7.4.4 Up Sampler
The Up Sampler channel increases the number of samples taken from the input
channel by a user-defined factor, enabling correlation of input data with that of a
channel with a higher sample rate on a point-for-point basis. Each input channel
sample repeats a number of times during the interval between the first sample and the
next one based on a conversion factor value. For example, a factor of three causes the
channel to repeat the sample twice after the original, giving three samples per original
sample as shown in the graphic below.
Figure 7-2: An illustration of the Up Sampler computed channel.
NOTE
Storing the output in memory increases the memory required for test data proportional
to the up factor. Using the output only for intermediate calculations does not affect data
storage memory.

Input Channel
The input channel can be any data type.
Output Data Type
The output data type is the same as the input data type.
Factor
Specify the desired up sample factor.
7.4.5 Smoothing Filter
The Smoothing Filter channel generates an output channel that is a smoothed
representation of the input channel without generating any phase lead or lag. The filter
is a simple boxcar filter where each output sample is the linear average of a
user-specified number of input samples. For example, for a tap count of five, the filter
I2740-2.1 en 167
SoMat eDAQ
averages the current sample, the two samples before and the two samples after. Note
that the channel backfills the initial output samples with the first fully filtered output
value. For example, if the tap count is nine, the first four output samples are assigned
the same value as the fifth output sample value.
NOTE
The Smoothing Filter can result in loss of data significance if not used properly. In
general, it should not be necessary for analog input channels that use digital
anti-aliasing filters. It is provided primarily for digital pulse counter inputs.

Input Channel
The input channel data type must be 32-bit float or 16-bit integer.
Output Data Type
The output data type is the same as the input data type.
Filter Length
Specify the desired length of the boxcar filter. The number must be an odd number
between 3 and 201.
7.4.6 Digital Filter
The Digital Filter computed channel generates an FIR digitally filtered output channel
based on an ASCII file. The file format conforms to the conventions used by MATLAB
to generate ASCII filter files including the following:
All fields are floating point values, using only whitespace delimiters (e.g.,
spaces, tabs, newlines etc.).
The first field is the number of tap coefficients. There must be at least two taps.
The second field is the filter delay which synchronizes the filtered output data
with the input data. The value can range from zero to the number of taps minus
one.
The third field is the filter gain. This field is optional in the sense that TCE does
not use it directly. However, it does provide a check. If the gain value is not 0.0,
then TCE checks the gain value against the sum of the tap coefficients and
reports any significant conflict.
The remaining fields are the ordered array of tap coefficients.
Numerous examples are available in the TCE installation kit. See the files in the hsfilter
and sfilter subdirectories under the main TCE install directory.
Digital Filter Processing Notes
In the steady-state, the taps coefficients are multiplied by the input data sample values and these products are summed
to form a single filtered data output value. This process is obviously computationally intensive if there are a large
number of taps.
If the filter delay is greater than zero (which is typically the case), the first output samples cannot be fully filtered. The
eDAQ backfills these first output samples using the first fully filtered data value. For example, if the delay is nine, the
first nine output samples are assigned the same value as the tenth output sample value.

SoMat eDAQ
168 I2740-2.1 en
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output channel data type is 32-bit float.
File
Specify the full path name of the ASCII file that defines the filter. Use the browse button
to select the desired file. Use the check file option to parse the ASCII file and verify that
the format is valid.
NOTE
Because TCE parses the ASCII file at test initialization, any changes to the file prior to
initialization are effective for subsequent test runs.

Normalize
Select the normalize tap coefficients option to normalize all tap coefficients for a unity
gain.
7.5 Tracking Computed Channels
7.5.1 Max Track
The Max Track channel generates an output channel that tracks the maximum value
of the input channel. A logical channel specified as a trigger can reset the output
channel tracking.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer.
Output Data Type
The output data type is the same as the input data type.
Enable Triggered Reset
Select the triggered reset option to enable triggered resets of the tracker.
NOTE
Resetting the tracker sets the maximum value to the current sample value.

Trigger Channel
If using the reset enable feature, specify the desired trigger channel.
Trigger Mode
If using the reset enable feature, specify one of three available trigger reset modes.
I2740-2.1 en 169
SoMat eDAQ
7.5.2 Min Track
The Min Track channel generates an output channel that tracks the minimum value of
the input channel. A logical channel specified as a trigger can reset the output channel
tracking.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer.
Output Data Type
The output data type is the same as the input data type.
Enable Triggered Reset
Select the triggered reset option to enable triggered resets of the tracker.
NOTE
Resetting the tracker sets the minimum value to the current sample value.

Trigger Channel
If using the reset enable feature, specify the desired trigger channel.
Trigger Mode
If using the reset enable feature, specify one of three available trigger reset modes.
7.5.3 Range Track
The Range Track channel generates an output channel that tracks the range of the
input channel. A logical channel specified as a trigger can reset the output channel
tracking.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer.
Trigger Mode Description
When TRUE Reset when the trigger channel is TRUE.
On FALSE-TRUE edge Reset when the trigger transitions from FALSE to TRUE.
On TRUE-FALSE edge Reset on the sample after the trigger channel transitions from
TRUE to FALSE.
Trigger Mode Description
When TRUE Reset when the trigger channel is TRUE.
On FALSE-TRUE edge Reset when the trigger transitions from FALSE to TRUE.
On TRUE-FALSE edge Reset on the sample after the trigger channel transitions from
TRUE to FALSE.
SoMat eDAQ
170 I2740-2.1 en
Output Data Type
The output data type is 32-bit float if the input channel data type is 32-bit float and
16-bit unsigned if the input channel data type is 16-bit integer.
Enable Triggered Reset
Select the triggered reset option to enable triggered resets of the tracker.
NOTE
Resetting the tracker sets the range value to zero.

Trigger Channel
If using the reset enable feature, specify the desired trigger channel.
Trigger Mode
If using the reset enable feature, specify one of three available trigger reset modes.
7.5.4 Anomaly Detect
The Anomaly Detect channel generates an output marking possible anomalies in
transducer or computed channel data flow. The eDAQ continuously tracks the selected
parameters in the analysis window of a user-defined size and outputs a status byte for
each window. Each bit in the status byte corresponds to a particular anomaly detection
routine. Use with a Bitmap Trigger computed channel to generate triggers based on
the anomaly detection. For more information on the Bitmap Trigger computed channel,
see Bitmap Trigger on page 163.
Trigger Mode Description
When TRUE Reset when the trigger channel is TRUE.
On FALSE-TRUE edge Reset when the trigger transitions from FALSE to TRUE.
On TRUE-FALSE edge Reset on the sample after the trigger channel transitions from
TRUE to FALSE.
Bit Routine Description
Bit 1 Flat line Determine if the data is nearly constant over a user-defined time
period.
Bit 2 Drift Determine if the data mean drifts from the start of the test run.
Bit 3 Limit Determine if the data exceeds user-defined maximum or minimum
limits.
Bit 4 Kurtosis Detection determine if the data exceeds the user-defined kurtosis
coefficient limit.
Bits 5 through 8 are reserved for future expansion.
I2740-2.1 en 171
SoMat eDAQ
The units parameter is always logic and the full-scale min is fixed at zero. The full-scale
max is the integer value of the largest possible output byte. For example, if using the
kurtosis and drift detection routines, the highest active bitmap is binary 00001010,
which equals ten.
Input Channel
The input channel data type must be 32-bit float.
Output Data Type
The output channel data type is 8-bit unsigned (bitmap). The only computed channel
or DataMode that accepts a bitmap input is the Bitmap Trigger computed channel.
Window Samples
Specify the number of input samples to to generate one output sample. This sets the
analysis window size and associated output sample rate. The factor can be any
positive integer greater than one.
Flat Line Detect
Select the flat line detect routine to enable flat line detection. If the difference between
the maximum and minimum data samples in the analysis window is less than the
specified range gate, bit 1 of the output byte is set to 1.
Drift Detect
Select the drift detect routine to enable drift detection. TCE sets the reference mean
as the mean value of the first window for each test run. If the difference between the
current window mean and the reference mean exceeds the specified mean gate, bit 2
of the output byte is set to 1.
Limit Detect
Select the limit detect routine to enable limit detection. If any data sample in the
analysis window is greater than the specified maximum limit or less than the specified
minimum limit, bit 3 of the output byte is set to 1.
Kurtosis Detect
Select the kurtosis detect routine to enable kurtosis detection. If the kurtosis coefficient
for the data in the analysis window is greater than the specified maximum limit, then
bit 4 of the output byte is set to 1. The eDAQ uses the following equation to calculate
the kurtosis coefficient:
where, N is the number of data samples in the analysis window and x
mean
is the mean
of the data samples in the analysis window.
7.5.5 Valid Data Gate
The Valid Data Gate channel generates a logical channel data stream on a sample by
sample basis marking samples containing invalid data. The output sample is TRUE if
and only if the data samples for all input channels are valid; otherwise, the output
sample is FALSE. Use the Valid Data Gate channel by itself or in conjunction with other
logical channels as a gate trigger for DataModes to eliminate any invalid data samples.
SoMat eDAQ
172 I2740-2.1 en
Input Channel
The only channels that currently use invalid flags are vehicle bus, serial bus, GPS and
temperature channels. All data types are supported.
Output Data Type
The output channel data type is 8-bit unsigned (logical).
I2740-2.1 en 173
SoMat eDAQ
8 DataModes
This chapter details the available DataModes and their associated parameters and
discusses data storage and memory considerations. DataModes determine how the
eDAQ stores and displays test data. A DataMode definition consists of a list of input
channels, a data storage/processing rate, triggering conditions and other parameters
specific to the DataMode.
8.1 DataMode Memory Consumption
The defined DataModes determine the rate at which the eDAQ consumes memory.
There is some overhead for storing the test setup file and other eDAQ files, but typically
these files require much less that 1 MB for most large channel count test setups and
proportionately less for tests with fewer channels.
For SIE data files, there is additional overhead for the data file internal linkage and
consistency check parameters. The overhead is usually insignificant, consuming only
a few percent of the data file.
For SIF data files, there is additional overhead for the data file header information and
internal pointers. This overhead is usually fairly insignificant, consuming only a few
percent of the data file. However, there are some situations where this overhead can
become very significant. In particular, the overhead in storing burst data records in the
Burst History DataMode (see Burst History on page 176) can be very significant
when a small number of burst points (less than 100) is specified. Also, a large number
of short test runs can significantly add to the overhead required.
Different DataModes and data type compression modes require different amounts of
memory. The eDAQ consumes raw data storage memory, excluding overhead, as
detailed in the following table.
NOTE
The Rainflow DataMode (see Rainflow on page 183) adds 4096 bytes of 32-bit float
data per channel for the rainflow stack size.

8.2 Common DataMode Parameters
ID
Unique identifier for the channel. This must conform to ID naming conventions. Valid
ID names:
are case sensitive
are limited to a maximum of 12 characters
DataMode Data Type Memory Consumption
Sequential 32-bit float 4 bytes per data point per channel
16-bit integer 2 bytes per data point per channel
8-bit integer 1 byte per data point per channel
Histogram 32-bit unsigned 4 bytes per bin per channel
SoMat eDAQ
174 I2740-2.1 en
contain only valid characters (i.e., letters (a-z, A-Z), digits (0-9), and the
underscore (_) character)
start with a letter
are not duplicates of system reserved names (sin, cos, log, etc.)
Input Channel
Select the input channel or channels to the DataMode. The total number of input
channels for any DataMode is limited to 256. Use multiple DataModes for more than
256 input channels. All input channels to a single DataMode must have the same
sample rate and be defined for the same network node. For a summary of the data
types compatible with each DataMode, see Data Types on page 203.
Network Node
This field displays the defined network node for the DataMode.
Triggering Option
Select one of four available triggering options. Triggering provides a mechanism for
eliminating undesired segments of the input data stream before it is processed by any
particular DataMode algorithm.
Trigger Channel
Specify the trigger input when using a trigger option other than always on.
NOTE
The optional trigger channel must have the same sample rate as the set of input
channels to the DataMode.

Triggering Option Description
Always On Do not use triggering. Data sampling is always on from the start
of the test.
Trigger Data sampling starts when the trigger channel becomes TRUE.
Once the trigger channel is TRUE, data sampling runs
continuously, irrespective of any future changes in the trigger
channel.
Gate Data sampling occurs if and only if the trigger channel is TRUE.
Data sampling stops when the trigger channel is FALSE.
One Shot Take a single data sample when the trigger channel transitions
from FALSE to TRUE or if the trigger channel is TRUE on the first
sample of any run.
I2740-2.1 en 175
SoMat eDAQ
Data Storage
Select whether to store test data on the RAM disk or on the PC Card media (external
PC Card, DRAM or internal Flash) as selected in the web interface. For more
information on data storage options, see Data Storage Options on page 37.
NOTE
The eDAQ does not support storing SIE data on the RAM Disk. Regardless of the data
storage setting, the eDAQ saves SIE data to the storage device selected in the web
interface. If the PC Card storage device is selected and there is no PC Card in the
eDAQ, the TCE cannot initialize the test.

For more information on data storage options, see Data Storage.
8.3 Sequential DataModes
8.3.1 Time History
The Time History DataMode stores multiple channels of triggered or un-triggered time
history data streams in the output data file.
NOTE
If using the trigger, gate or one shot trigger conditions, the x -axis label in InField is
collection time to distinguish from the time from the start of the test run. If using the
always on trigger condition, the label is simply time.

CAUTION
If the setup file has a Time History DataMode that uses any trigger channel and if an
eDAQ error reset occurs while a test run is in progress, some of the acquired Time
History data will be lost. The maximum amount of data that can be lost is the data
frame size for the Time History input channels. For example, if the sample rate is
100 Hz and the pipe frame size is 2.5 Hz, then the frame size is 40 data samples.
While this is not a big number, it can represent significant data losses if using the one
shot trigger mode to capture rare events.

Input Channel
The input channels can be any data type.
Data Storage Option Description
PC Card The eDAQ stores all data in a file on the PC Card file system
media. For SIF data collection, other file components, such as the
header file and keywords, are stored on the RAM disk. For
histogram DataModes, the eDAQ maintains the histogram data in
DRAM memory while the test is running and then copies the data
to a file on the PC Card after test completion.
RAM disk (SIF only) The eDAQ builds the SIF data file in RAM disk memory.
SoMat eDAQ
176 I2740-2.1 en
Data Type
For 32-bit float input channels, select one of three available formats for data storage
and conversion.
NOTE
Using the integer data types requires that valid full-scale minimum and maximum
values are defined for each input channel selected for the DataMode.

8.3.2 Burst History
The Burst History DataMode stores one or more bursts of data when a user-defined
triggering event occurs. The term burst refers to a set of contiguous data samples. The
Burst History DataMode is particularly useful for characterizing rare events at high
data sampling rates. The eDAQ uses a circular buffer to allow storage of data both
before and after the specified trigger.
NOTE
The total number of points stored is the sum of the post-trigger and pre-trigger time
periods multiplied by the selected data sampling rate plus one since the trigger sample
is always stored.

Input Channel
The input channels can be any data type.
Data Type
For 32-bit float input channels, select one of three available formats for data storage
and conversion.
Data Type Description
32-bit float No conversion is necessary. Use the 32-bit float mode for computed
channels where full-scale estimates are uncertain or unknown.
16-bit integer Maintain the resolution of both the 12-bit and 16-bit A/D converters.
8-bit integer Lose significant resolution in both the 12-bit and 16-bit A/D converters.
Use the 8-bit integer mode only for a rough picture of channel
behavior.
I2740-2.1 en 177
SoMat eDAQ
NOTE
Using the integer data types requires that valid full-scale minimum and maximum
values are defined for each input channel selected for the DataMode.

Post-Trigger Time
Specify the desired period of time in seconds for data sampling after the trigger.
Pre-Trigger Time
Specify the desired period of time in seconds for data sampling before the trigger.
Number of Bursts
Specify an upper limit on the number of bursts the eDAQ can store. The DataMode
effectively turns off after storing this number of bursts.
NOTE
Using the max bursts mode option limits the number of bursts to 250.

Max Bursts Mode
Select enable max bursts mode to store the most significant burst records according
to the following criteria. After storing the user-defined maximum number of burst
records, the eDAQ compares each new burst record to the least significant burst
already stored. If the new burst is more significant, the eDAQ overwrites the least
significant burst record with the new burst record, retaining the most significant burst
records. The max bursts mode adds significant processing overhead.
NOTE
The max bursts mode option is not available if using the PC Card data storage mode.

Max Bursts Reference Value
Specify the reference value used in determining burst significance for the max bursts
mode.
Data Type Description
32-bit float No conversion is necessary. Use the 32-bit float mode for computed
channels where full-scale estimates are uncertain or unknown.
16-bit integer Maintain the resolution of both the 12-bit and 16-bit A/D converters.
8-bit integer Lose significant resolution in both the 12-bit and 16-bit A/D converters.
Use the 8-bit integer mode only for a rough picture of channel
behavior.
SoMat eDAQ
178 I2740-2.1 en
DRAM Buffering
Selecting the DRAM buffering mode allocates the circular buffer used for burst data
capture in DRAM memory. Otherwise, the eDAQ allocates the circular buffer directly
on the Linux file system media. DRAM buffering is only available when using the
external PC Card or internal CompactFlash memory for data storage.
NOTE
SIE file data always uses the DRAM buffering option.

CAUTION
All test data in DRAM memory is lost if the eDAQ powers down or resets for any
reason.

Selecting the DRAM buffering option is advised as long as the DRAM allocations
required are not too large. Updating the circular buffer allocated in DRAM is very
efficient as is copying the circular buffer filled with a burst record to the PC Card
memory in a linear manner.
Allocating, the circular buffer directly in the PC Card file system memory is somewhat
less efficient in general because of the overhead in constantly writing to the PC Card
memory. Furthermore, for rotating disks, the seeks required when the circular buffer
wraps around will adds a periodic burden to performance efficiency. Also note that
repetitively overwriting the same flash memory area produces wear and reduces the
life of the flash memory.
NOTE
When considering DRAM buffering, note that the eDAQ can only copy full burst
records for DRAM to PC Card memory. Not using the DRAM buffering mode allows
the eDAQ to store partial burst records if, for example, the test run stops before the
burst is full.

I2740-2.1 en 179
SoMat eDAQ
Application Note: Guidelines for Setting the DRAM Buffering Option
If the total DRAM allocation for all Burst History channels for a single burst record is 500 kB or less, selecting the DRAM option
is advised for maximum throughput efficiency. If the total DRAM allocation is 4 MB or more, then selecting the DRAM option
is not advised and can cause a DeviceOverFlow error when the eDAQ attempts to copy the DRAM buffers to the PC Card
memory. For the gray area in the 500 kB to 4 MB range, first try not using the DRAM buffers.
Examples:
Do not use DRAM buffering: One Burst History DataMode defined with 16 channels of 16-bit integer data sampled at
1000 Hz for 600 seconds requires 9200000 bytes (16*2*1000*600) per burst record.
Use DRAM buffering: One Burst History DataMode defined with 16 channels of 16-bit integer data sampled at 500 Hz
for 20 seconds requires 320000 bytes (16*2*500*20) per burst record.
Try not using DRAM buffering: One Burst History DataMode defined with 16 channels of 16-bit integer data sampled
at 500 Hz for 10 seconds requires 320000 bytes (16*2*500*20) per burst record and a second burst DataMode defined
with 8 channels of 32-bit float data sampled at 2000 Hz for 10 seconds requires 640000 bytes (8*4*2000*10) per burst
record for a total of 960000 bytes.

8.3.3 Event Slice
The Event Slice DataMode stores a set of master channels and a set of slave channels
in the output data file. The set of master channels provides a sequence of events,
which are defined as changes in the state of any master input channel. For each event,
the eDAQ stores data samples for all channels (masters and slaves) in the output data
file.
Master Input Channels
Select the desired set of master input channels using CTRL to select more than one
channel. The master input channels can be any data type.
Slave Input Channels
Select the desired set of slave input channels using CTRL to select more than one
channel. The slave input channels can be any data type.
Data Type
For 32-bit float input channels, select one of three available formats for data storage
and conversion.
NOTE
Using the integer data types requires that valid full-scale minimum and maximum
values are defined for each input channel selected for the DataMode.

Data Type Description
32-bit float No conversion is necessary. Use the 32-bit float mode for computed
channels where full-scale estimates are uncertain or unknown.
16-bit integer Maintain the resolution of both the 12-bit and 16-bit A/D converters.
8-bit integer Lose significant resolution in both the 12-bit and 16-bit A/D converters.
Use the 8-bit integer mode only for a rough picture of channel
behavior.
SoMat eDAQ
180 I2740-2.1 en
Time Input Channel
Optionally, select a Time Channel computed channel from the provided list. For more
information on the Time Channel computed channel, see Time Channel on
page 164).
Store Initial State
Set the store initial state parameter to yes to always store the initial state at the start
of each test run.
8.3.4 Message Logger
Use the Message Logger DataMode to store one or more input message channels in
the data file.
NOTE
The Message Logger supports the PC Card data storage option only.

Input Channel
The input channel is limited to message channel sources, which are all 8-bit unsigned.
8.3.5 Peak Valley
The Peak Valley DataMode stores multiple channels of peak and valley sequences in
the output data file. The eDAQ acquires peaks and valleys from triggered or
un-triggered time history data streams using the user-specified hysteresis value and
the peak valley processing algorithm. For more information on the peak valley
processing algorithm, see Peak Valley Processing Algorithm on page 253.
Input Channel
The input channel data type must be 8-bit integer, 16-bit integer or 32-bit float.
Data Type
For 32-bit float input channels, select one of three available formats for data storage
and conversion.
NOTE
Using the integer data types requires that valid full-scale minimum and maximum
values are defined for each input channel selected for the DataMode.

Data Type Description
32-bit float No conversion is necessary. Use the 32-bit float mode for computed
channels where full-scale estimates are uncertain or unknown.
16-bit integer Maintain the resolution of both the 12-bit and 16-bit A/D converters.
8-bit integer Lose significant resolution in both the 12-bit and 16-bit A/D converters.
Use the 8-bit integer mode only for a rough picture of channel
behavior.
I2740-2.1 en 181
SoMat eDAQ
Hysteresis
Specify the desired hysteresis level for the peak valley processing algorithm.
8.3.6 Peak Valley Slice
The Peak Valley Slice DataMode stores a set of master channels and a set of slave
channels in the output data file. The set of master channels provides a peak/valley
sequence acquired using the user-specified hysteresis value and the peak valley
processing algorithm. For each peak or valley on any master channel, the eDAQ
stores data samples for all channels (master and slaves) in the output data file. For
more information on the peak valley processing algorithm, see Peak Valley
Processing Algorithm on page 253.
NOTE
If no slave channels are required, it is more efficient to use the Peak Valley DataMode
(see Peak Valley on page 180).

Master Input Channel
Select the desired set of master input channels using CTRL to select more than one
channel. The master input channel data type must be 8-bit integer, 16-bit integer or
32-bit float.
Slave Input Channel
Select the desired set of slave input channels using CTRL to select more than one
channel. The slave input channels can be any data type.
Data Type
For 32-bit float input channels, select one of three available formats for data storage
and conversion.
NOTE
Using the integer data types requires that valid full-scale minimum and maximum
values are defined for each input channel selected for the DataMode.

Time Input Channel
Optionally, select a Time Channel computed channel from the provided list. For more
information on the Time Channel computed channel, see Time Channel on
page 164.
Data Type Description
32-bit float No conversion is necessary. Use the 32-bit float mode for computed
channels where full-scale estimates are uncertain or unknown.
16-bit integer Maintain the resolution of both the 12-bit and 16-bit A/D converters.
8-bit integer Lose significant resolution in both the 12-bit and 16-bit A/D converters.
Use the 8-bit integer mode only for a rough picture of channel
behavior.
SoMat eDAQ
182 I2740-2.1 en
Plateau Size
Specify the criterion for storing a peak or valley candidate slice as a plateau event. The
size refers to the minimum number of peak and valley slices in the holding queue that
must exist before the eDAQ stores the blocking peak or valley candidate slice as a
plateau event. For example, if the plateau size is 50, then at least 50 peak and valley
slices must exist in the holding queue before treating the blocking peak or valley
candidate slice as a plateau. Note that for most typical usages of the Peak/Valley Slice
DataMode using multiple master channels, there will be very few (if any) slices stored
on this plateau criterion.
Hysteresis
Specify the desired hysteresis level for the peak valley processing algorithm.
8.4 Histogram DataModes
8.4.1 Common Histogram Parameters
Accumulate Runs Across All Tests
Selecting the accumulate runs across all tests option generates one histogram for all
test runs. Otherwise, the eDAQ generates a unique histogram for each run.
NOTE
The option to accumulate across all test runs is available only when using the eDAQ
RAM storage option with the SIF data format.

Histogram Bin Type
Select evenly-divided or user-defined bin types. Each histogram bin can accumulate
counts up to 4294967295.
NOTE
For either of the bin types, the eDAQ uses underflow and overflow bins to count the
occurrences that fall outside of the defined histogram limits.

Number of Bins
Select the desired number of bins for each histogram. See the entry for each
DataMode for specific information on the number of bins for each DataMode.
Bin Type Description
Evenly Divided The width of each bin is equal. The default histogram limits for each
input channel are based on the defined full-scale values for the input
channel. The bin size is simply the difference between the histogram
limits divided by the number of bins. Use the slider in the histogram bin
editor to select the number of bins.
User Defined The width of each bin is defined independently. Use the buttons in the
histogram bin editor to add or delete bins. Define the bin boundaries
for each dimension of the histogram in the histogram window.
I2740-2.1 en 183
SoMat eDAQ
8.4.2 Peak Valley Matrix
The Peak Valley Matrix DataMode stores multiple channels of peak valley reversal
histograms in the output data file. The eDAQ acquires peaks and valleys from
triggered or un-triggered time history data streams using the user-specified hysteresis
value and the peak valley processing algorithm. The resulting peak valley stream
defines the set of peak valley reversals which are histogrammed using the
user-defined options for the type and size of histogram. For more information on the
peak valley processing algorithm, see Peak Valley Processing Algorithm on
page 253.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer. If using the
user-defined bins option, the input channel data type must be 32-bit float.
Histogram Mode
Select one of three available histogramming modes.
Hysteresis
Specify the desired hysteresis level for the peak valley processing algorithm.
Number of Bins
Specify the desired number of bins up to 500 for the histogram. For the range-mean
and the to-from histogram modes, the value is for both histogram dimensions. The
total number of bins per dimension is the user-specified number of bins plus two for
underflow and overflow bins. For the range-mean and to-from histogram modes which
have two dimensions, the total number of bins for the DataMode is the product of the
total number of bins for each dimension.
8.4.3 Rainflow
The Rainflow DataMode stores multiple channels of rainflow cycle histograms in the
output data file. The eDAQ acquires peaks and valleys from triggered or un-triggered
time history data streams using the user-specified hysteresis value and the peak valley
processing algorithm. The resulting peak valley stream runs through the rainflow cycle
counting algorithm to yield the set of closed cycles. The closed cycles are
histogrammed using the user-defined options for the type and size of histogram. For
more information on the data processing algorithms used, see Data Processing
Algorithms on page 253.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer. If using the
user-defined bins option, the input channel data type must be 32-bit float.
Mode Description
Range-Mean Accumulate reversal counts in bins with both a reversal range
dimension and a cycle mean value dimension.
Range Only Accumulate reversal counts in bins with only a reversal range
dimension.
To-From Accumulate reversal counts in bins with both a to dimension and a
from dimension. The eDAQ assigns to and from designations to each
reversal.
SoMat eDAQ
184 I2740-2.1 en
Histogram Mode
Select one of three available histogramming modes.
Hysteresis
Enter the desired hysteresis level for the peak valley processing algorithm.
Number of Bins
Specify the desired number of bins up to 500 for the histogram. For the range-mean
and the to-from histogram modes, the value is for both histogram dimensions. The
total number of bins per dimension is the user-specified number of bins plus two for
underflow and overflow bins. For the range-mean and to-from histogram modes which
have two dimensions, the total number of bins for the DataMode is the product of the
total number of bins for each dimension.
8.4.4 Time at Level (One Dimensional)
The Time at Level (1D) DataMode stores one-dimension Time at Level histograms in
the output data file. Specify multiple input channels to generate multiple
one-dimensional Time at Level data channels.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer. If using the
user-defined bins option, the input channel data type must be 32-bit float.
Number of Bins
Specify the desired number of bins. The total number of bins is the user-specified
number of bins plus two for underflow and overflow bins.
8.4.5 Time at Level (Multidimensional)
The Time at Level (mD) DataMode stores a multiple-dimension Time at Level
histogram in the output data file.
Input Channel
The input channel data type must be 32-bit float or 16-bit integer. If using the
user-defined bins option, the input channel data type must be 32-bit float.
Number of Bins
Select the desired number of bins for each dimension. Separate the individual bin
count specifications by spaces or commas. The total number of bins for each
dimension is the user-specified number of bins plus two for underflow and overflow
bins. The total number of bins for the DataMode is the product of the total number of
bins for each dimension. For example, defining the number of bins for four input
channels as 10, 20, 5 and 15 results in 31416 (i.e. 12*22*7*17) total number of bins.
Mode Description
Range-Mean Accumulate cycle counts in bins with both a cycle range dimension
and a cycle mean value dimension.
Range Only Accumulate cycle counts in bins with only a cycle range dimension.
To-From Accumulate cycle counts in bins with both a to dimension and a from
dimension. The eDAQ assigns to and from designations to the first
reversal instead of the second on which the cycle actually closes.
I2740-2.1 en 185
SoMat eDAQ
8.5 Digital Output
A Digital Output is a pseudo-DataMode. Digital outputs are compatible with the first
eight bits on each bank of the EDIO and any digital bit on the ECPU. For more
information on EDIO digital outputs, see EDIO Digital Input/Output on page 99. For
more information on ECPU digital outputs, see ECPU Digital Input/Output on
page 95.
Use the Digital Output definition window for each layer to define all desired digital
outputs for that layer. For each desired output target bit, specify the associated logical
control channel, output mode, initial state and stop run action. Use the control channel
select area of the window or type the desired values directly into the digital output list.
NOTE
When using the control channel select area, double click the desired logical channel
to complete each digital output definition.

Figure 8-1: TCE Digital Output DataMode definition window.
Use the Test button to open a window for testing the digital output bits and the devices
tied to the output lines. The test window contains a set of check boxes corresponding
to the set of available digital output lines. Check or uncheck the desired bits and select
Set Bits to set the digital output lines based on the bit selections. A checked box sets
the output to high (TRUE) and an unchecked box sets the output to low (FALSE).
Target Bit
Select the desired digital output bit on the selected connector. A bit must be configured
as an output using the ECPU or EDIO configuration options. If a selected bit is
configured as an input, TCE issues a warning. For more information on configuring
digital bits as outputs on the EDIO layer, see EDIO Configuration Options on
page 100.
Control Channel
The control channel specifies the logical input channel to drive the digital output. Use
the presented list to select any defined logical channel with a data type of 8-bit
unsigned (logical).
SoMat eDAQ
186 I2740-2.1 en
Initial State
For each digital output, select the initial state as either high (TRUE) or low (FALSE).
The eDAQ imposes the initial state at the start of the test run.
Stop Run Action
For each digital output, select the desired action when the test run stops.
Output Mode
Each digital output has five available output modes. The sample interval is the time
period associated with the sample rate of the input channels. Since the input channels
defined in the data mode can have different sample rates, the sample interval can vary
from channel to channel. The abbreviation used in the channel definition is in
parentheses.
Stop Run Action Description
No Action Do not change the output line when the test run stops.
Set Hi Set the output line to high (TRUE) when the test run stops.
Set Lo Set the output line to low (FALSE) when the test run stops.
Output Mode Description
Normal-Unlatched (N-U) Output TRUE if the sample interval contains a TRUE value;
otherwise, output FALSE.
Invert-Unlatched (I-U) Output FALSE if the sample interval contains a TRUE value;
otherwise, output TRUE.
Normal-Latched (N-L) Output TRUE and hold through the end of the test if the sample
interval contains a TRUE value.
Invert-Latched (I-L) Output FALSE and hold through the end of the test if the sample
interval contains a TRUE value.
Toggle-Latched (T-L) Toggle output between TRUE and FALSE for every sample
interval containing a TRUE value. The toggle rate is nominally
one second.
I2740-2.1 en 187
SoMat eDAQ
9 eDAQ Web Interface
The eDAQ web interface provides controls to activate saved test initializations, start
and stop test runs, monitor test status, and end initialized tests. The web interface can
also perform a number of system configuration and other utility operations, including
formatting PC Cards, modifying ethernet and serial communication settings, and
upgrading eDAQ firmware with new version releases.
9.1 Main Page
With a TCP/IP connection between the support computer and eDAQ, enter the
eDAQs IP address into any web browser to access the main page of the eDAQ web
interface.
Figure 9-1: Main page of the eDAQ web interface.
The information bar across the top of the page displays the eDAQs IP address, the
date and time that the page was loaded and a battery status indicator. When a test is
initialized, the information bar also indicates the name of the test setup, the run
number and either a go control when the test is stopped or a stop control when a test
is running. Refresh the page to update the displayed information as the interface does
not automatically refresh.
The tab menu just below the information bar provides access to categories of available
operations. Open the page for each category by clicking on the appropriate tab. The
subsequent sections of this chapter describe the available operations.
9.2 System Tab
The System tab provides several tools for setting up, maintaining and monitoring the
eDAQ.
SoMat eDAQ
188 I2740-2.1 en
Figure 9-2: System tab of the eDAQ web interface.
9.2.1 System Setup
The system setup group of pages provide methods to modify the network
configuration parameters, RS-232 communication parameters, remote user name and
password and the time zone in which the eDAQ resides.
Network Setup
Use network setup parameters to modify the host name, IP number, netmask and
gateway as required.
RS-232 Setup
Set the serial communication parameters within the eDAQ by modifying file
pgetty.conf, the file containing all configuration information for serial communication.
CAUTION
Errors within pgetty.conf can cause all serial communication to cease to function. Use
extreme caution when modifying this file.

Remote Username and Password Setup
Set the usernames and passwords that are allowed remote access to the eDAQ
through a dial-up connection. To make changes to this setup, modify the file as
needed. In the default configuration shown below, ppp is the remote username and
123 is the password for that user.
Time Zone Setup
Set the current time zone in which the eDAQ resides. The current time zone, local time
and universal time (UTC) are provided.
I2740-2.1 en 189
SoMat eDAQ
9.2.2 System Status
The system status group of operations provides access to information about the
current state of the eDAQ system.
Show Ethernet TCP/IP Configuration
Display information about the current configuration of the ethernet TCP/IP
communication system setup.
Show Running Processes
Display a list of the currently running processes on the eDAQ.
9.2.3 System Maintenance
Explore eDAQ Files
Open the eDAQ file system to browse its contents. The copy file option opens the
interface for transferring a file from the PC to the eDAQ. The current location within the
file system is the default destination path in the copy interface.
Transfer a File to the eDAQ
Open the interface to copy a file from the PC to the eDAQ. Enter the path and file name
of the file to copy and the destination path within the eDAQ file system. Click Copy to
eDAQ to copy the file.
Command Prompt
Open the command prompt interface that allows direct entry of Linux shell commands
to the eDAQ operating system. This operation is for expert use only.
CAUTION
Serious damage to the system can occur through the use of system commands.
Therefore, use extreme caution should when entering shell commands.

Reset eDAQ
Perform a programmed reset of the eDAQ unit. Use this option only if necessary, such
as when the system is not responding.
9.3 Hardware Tab
The Hardware tab contains information about the hardware contained in the eDAQ
stack including the network node associated with the hardware, the type of layer and
its serial number, the version number of the code contained in the flash memory and
information about the PC Card (if installed).
SoMat eDAQ
190 I2740-2.1 en
Figure 9-3: Hardware tab of the eDAQ web interface.
9.3.1 Hardware Table
Node
The node column indicates the associated network node by its IP address.
Connector
The connector column indicates the layer identifier prefix used in hardware connector
IDs.
Card Type
The card type column shows each layer type. Certain eDAQ layers allow for additional
configuration such as enabling message logging and editing of parameter databases.
When this additional configuration is available, the card type listed is enabled as a
hyperlink and, when selected, opens additional pages for configuration options.
The additional configuration available for the vehicle bus layer includes editing
parameter databases, importing a vector CANdb database, logging messages,
viewing status and resetting the vehicle bus hardware. Navigate to the Help tab for
more detailed information on vehicle bus options.
Serial Number
The serial number column indicates the unique serial number of the layer in the stack.
Code
The code column displays the version of the code (i.e., firmware) that controls the
layer. To update the code from the web interface, click the hyperlink. For layers that
place more than one entry in the hardware list, only one of the entries allows an update
to the firmware. For more information on updating firmware, see Updating Firmware
on page 29.
CAUTION
Failures during a critical point in any upgrade/reflash can cause the hardware to
malfunction, requiring its return to HBM for repair by a qualified HBM technician.

I2740-2.1 en 191
SoMat eDAQ
Hardware Specifics
The hardware specifics column includes other pertinent details about the layer such
as applicable ECNs, the selected storage media or GPS model.
An ECN is an engineering change notice signifying a physical modification made to
the hardware of a layer to correct or improve its performance. These changes are
recorded in non-volatile memory within the layer. Click the link to view the ECN number
and the date of the change.
Use the storage link in the MPB row to view details or reformat the PC Card media.
9.3.2 Manage Network Cameras
Click the Manage Network Cameras link to open the camera setup page.
Figure 9-4: Camera setup page of the eDAQ web interface.
Selected Network Cameras
The selected network cameras table shows the cameras selected to add to the eDAQ
hardware list. The table shows each cameras IP address, connector, serial number
and firmware code. The operations column shows a screen shot from the camera, the
name of the camera and a Deselect link. Click Deselect to remove the camera from
the table.
Click the Update eDAQ hardware list button to reset the eDAQ and update the
hardware list on the hardware tab to include the selected cameras shown in the table.
Click the Cancel Changes button to clear the selected network cameras table without
adding any cameras to the hardware list.
Available Networked Cameras
The available networked cameras shows the cameras on the network. A new or
unconfigured camera is identified as a Misconfigured Camera. An entry for a
misconfigured camera lists the camera serial number and IP address. Click the
Correct camera configuration link in the entry to start the camera configuration
process. Click the Remove link in the entry to remove the camera from the available
networked cameras list.
An entry for a configured camera lists the camera name, firmware version, serial
number and IP address. Click the Select this camera link in the entry to add it to the
selected network cameras table. Click the Remove link in the entry to remove the
camera from the available networked cameras list.
SoMat eDAQ
192 I2740-2.1 en
Click the Find Cameras on Network button to search for cameras on the network and
add them to the list of available cameras. To add a camera at a specific IP address,
enter the IP address and select Add Camera.
Configure Networked Camera
To configure a specific camera on the network, enter the camera serial number and
select Configure Camera. This is useful if the Find Cameras on Network function in the
previous section cannot find the camera on the network.
9.3.3 Select Storage Device
Use the pick list to select PC Card (if installed), internal Flash or DRAM and click
Change Storage Device to change the storage media used for test data storage. For
more information on eDAQ data storage, see Data Storage Options on page 37.
9.4 Channels Tab
The Channels tab provides information about the defined transducer, message and
computed channels in the most recently initialized test. The information displayed for
the transducer and message channels includes the unique ID, the connector, the
transducer type, the sample rate, the calibration date and other information pertinent
to the channel. The information displayed for computed channels includes the network
node associated with the channel, the unique ID, the prefix, a description and other
information pertinent to the channel.
9.5 Test Tab
The test tab provides information about the current test including the name of the
setup file, the current or next run number and the elapsed run time. Refresh the page
to update the test information.
Test Status
View a summary of test and eDAQ information including test run status, RAM disk
files, RAM disk memory and PC Card memory.
View eDAQ Logbook
View the log file maintained on the eDAQ unit. This file contains information on
significant eDAQ events (e.g., resets, test initializations, etc.) and the values of
pertinent eDAQ state variables. It is available primarily for HBM internal development
and field service troubleshooting.
Get TCE Setup File
Transfer the test setup file stored in the eDAQ to a user-specified PC disk file.
USB Display Setup
Set up the values to display on the optional USB LCD display.
Minimal Control Panel
Open a test control panel with the ability to start and stop test runs and upload SIF
data. The panel also includes indicators for run number, run time and PC Card
memory.
9.6 Data Tab
The Data tab provides access to view and save test data.
I2740-2.1 en 193
SoMat eDAQ
Figure 9-5: Data tab of the eDAQ web interface.
9.6.1 SIE Test Data
The SIE test data table shows all the SIE data files present on the eDAQ. The table
shows the name of each file, the date it was modified and options to view, transfer,
initialize and delete the file.
In the get column, click SIE File to upload the complete SIE file or Extract SIE
Channels to upload only select channel data. In the operate column, select Reinitialize
to initialize the eDAQ with the TCE setup file contained in the SIE file or Delete to
remove the SIE file from the eDAQ.
Click on Test Runs in the view column to view the test data as a set of test runs with
their start and stop times, elapsed time and test description. Click an individual test run
to open a table of the channels in the test run. Click All Channels in the view column
to display all of the channels in the data file with their descriptions, DatMode types,
sample rates and output samples.
When viewing a table of channels, click on Plot in the plot column to view a simple plot
of the channel data as a function of time. Click the name of the channel in the name
column to view basic channel information and the actual data collected during the test
run.
9.6.2 SIF Test Data
Use the get SIF file option to transfer the SIF data file from the eDAQ to the PC. The
table lists the completed test runs with the date and time of the run. Clicking on the test
run opens a table of channels that displays the run number, channel number,
DataMode type, sample rate and number of data points. Click on the channel name to
view basic channel information and the actual data collected during the test run.
Currently Time History and message channels are the only data types viewable via the
web interface.
9.7 Custom Tab
Use the Custom tab to install custom modules, such as a serial bus module, in the
eDAQ system. See the installation instructions provided with the firmware installation
for information on specific modules.
SoMat eDAQ
194 I2740-2.1 en
When custom modules are installed in the eDAQ, the page displays a table with the
name and installation path of the module, the current status (enable or disabled) and
a list of operations available for the module (enable/disable and remove).
To discuss a custom module created specifically for your companys needs, contact
your HBM sales representative.
9.8 Help Tab
The help tab contains links to help topics on using SIE data and vehicle buses.
I2740-2.1 en 195
SoMat eDAQ
10 Troubleshooting
10.1 Troubleshooting Procedure
When experiencing unusual problems with the eDAQ, contact HBM customer service
for assistance in resolving the situation. Expedite this process by being aware of the
tools and indicators available for tracking down problems and performing some actions
prior to calling HBM customer service. The following actions are recommended.
Document the problem
If possible, make a detailed note of the conditions under which the problem occurs. It
is particularly helpful to know if the problem is repeatable, happens occasionally or
happened only once and cannot now be repeated. Providing a test setup file can also
expedite the troubleshooting.
Check known problems
Check for the symptom in Known Problems and perform the recommended action. If
the problem is not solved, note the results for communication with HBM customer
service.
Use the eDAQ error reporting tools
The eDAQ has a significant amount of built in checks to flag error conditions and
provide information back to the user or HBM customer service.
Use the following eDAQ reporting tools:
1. Take note of the eDAQ front panel LEDs. When the eDAQ detects an abnormal
situation, it responds by turning the red LED on. For more information on the status
LEDs, see Status LEDs on page 25.
2. With the eDAQ connected to the PC, get the test status using TCE or the web
interface. Note any error or status flags and check the eDAQ Flags section for their
meaning. In a few cases, the flags may provide sufficient information to understand
the problem. For more information on getting the test status, see Monitoring Test
Status on page 78.
3. View the eDAQ log using TCE or the web interface. The log usually provides more
detailed information about the error or status flags and can be useful to HBM
customer service. In TCE, the eDAQ log is available from the FCS Setup menu.
Perform diagnostic test
If the eDAQ cannot repeatedly run the FTP diagnostic test without generating any
errors, there is most likely a problem with the ECPU, the communication cables or the
PC hardware or system configuration. If the errors occur at the same spot each time,
the RAM disk memory is the most likely problem. Run an FTP diagnostic test from the
Diagnostic submenu in the FCS Setup menu.
Format RAM disk
This is a way of resetting the RAM Disk allocations to a known state. Formatting
destroys all files in the RAM Disk memory, including any SIF data file components, so
use it with caution. If eDAQ to PC communications can be established, format the
RAM disk. The Format RAM Disk option is available from the FCS Setup menu.
SoMat eDAQ
196 I2740-2.1 en
10.2 Known Problems
Test data lost or corrupted after power cycling
If the eDAQ data file is lost or corrupted after a power cycle, the main backup battery
is most likely not properly charged. Test for a proper charge by turning on the eDAQ
and disconnecting the power source. The eDAQ should stay powered from the backup
battery for about 45 seconds.
PC Card file system is corrupt
If the PC Card is removed or if the eDAQ loses power during a test run with the PC
Card data storage option in use, then the PC Card file system can become corrupted.
If this occurs or is suspected, immediately attempt to transfer the test data to the PC
using the tools in TCE. If TCE reports corruption or any other anomalies, contact HBM
customer service. For more details, see Corrupt SIF File Data Recovery.
10.3 eDAQ Flags
10.3.1 Status Flags
The eDAQ status flags are set only when the eDAQ encounters an abnormal operating
condition. These flags do not result in a reboot of the eDAQ.
BadNVRAM
The BadNVRAM flag indicates that the NVRAM flash memory contains invalid data.
The NVRAM memory area holds a number of eDAQ configuration parameters,
including the default ECPU digital I/O configurations, the master sample rate
preference and the eDAQ reset options. When this occurs, the eDAQ resets the
NVRAM parameters to their default values.
BootError
The BootError flag indicates that the eDAQ did not complete the boot process. The
eDAQ writes additional information to the log file when this occurs. Please report this
error to HBM customer service.
CharChecksum
This CharChecksum flag indicates that the checksum stored with eDAQ layer
characterization data does not match the checksum computed for the characterization
data structure. Data acquired using an invalid characterization data structure is not
valid data.
Calibration
The Calibration flag indicates that a transducer calibration or rezero was not
completed in the expected manner. The two main reasons for this status flag are faulty
hardware and unexpected signal values, such as the voltage exceeding the defined
safe limits after rezeroing. The eDAQ generates Calibration errors only on the
channels that have programmable gain and offset capabilities (e.g., ELLB, EHLS and
EBRG channels).
eDAQReset
The eDAQReset flag indicates any eDAQ reboot. As such, it is simply an informative
message only.
I2740-2.1 en 197
SoMat eDAQ
MathException
The MathException flag indicates a floating point math exception such as taking the
square root of a negative number in a Desk Calculator computed channel. While not
a fatal error in itself, it does indicate a situation that is most likely undesirable.
ParityStatus
The ParityStatus flag indicates that there is a recoverable inconsistency in a RAM Disk
pointer structure. The RAM Disk pointers are stored in triple redundant fields. If only
one of the three pointers is inconsistent, the eDAQ changes it to match the other two
and sets this flag. If none of the three pointers are consistent, the eDAQ sets the
ParityError flag and resets itself.
PCMAccessError
The PCMAccessError flag indicates that the eDAQ cannot access the PC Card during
the start of test initialization, the start of a test run or the restart of a test run after a
power failure or an error reset. It is likely that the PC Card has been removed. If this is
the case, re-insert the PC Card and initialize or start the test.
PCMDataLosses
The PCMDataLosses flag indicates that a test did not complete the power failure exit
procedure or an error reset exit procedure. The flag can only occur if the test is running
with the PC Card data storage option. The typical scenario is a power failure with a
dead or disconnected backup battery. In almost all cases, this flag indicates loss of
some of the test data from the previous run.
PCMDiskError
The PCMDiskError flag indicates that there was a PC Card I/O error while running a
test or attempting to transfer data from the eDAQ. It is likely that the PC Card has been
removed, been damaged in some way or has had some intermittent problem. Data
integrity is suspect.
PCMDiskFull
The PCMDiskFull flag indicates that there is no more PC Card storage space available
for test data. DataModes that require additional memory (for example, Time History,
Peak/Valley, etc.) are suspended, but histogram DataModes keep running normally.
Let the test run continue or stop the test as desired. Note that attempting to start a new
test run without sufficient PC Card space to start causes the eDAQ to reboot itself.
PCMSIFCorrupt
The PCMSIFCorrupt flag indicates that the eDAQ has found corruption in the SIF data
file component on the RAM Disk. This flag stops the test run and ends the test.
Transfer the test data to the PC and reformat the RAM Disk. There can be major losses
of test data.
RainFlow
The Rainflow flag indicates a rainflow stack overflow in a Rainflow DataMode channel.
The eDAQ shuts down the channel on which the overflow occurred and proceeds in
an otherwise normal manner.
SoMat eDAQ
198 I2740-2.1 en
RAMDiskFull
The RAMDiskFull flag indicates that there is no more RAM Disk memory available for
storing test data. DataModes that require additional memory (e.g., Time History or
Peak/Valley) are suspended, but histogram DataModes keep running normally. Let the
test run continue or stop the test as desired. Note that attempting to start a new test
run without sufficient RAM Disk memory to start causes the eDAQ to reboot itself.
SmartModuleError
The SmartModuleError flag indicates that there is an error in eDAQ communications
to a SMART module or there is an error in the SMART module factory or user data
parameters. The eDAQ also sets this flag when detecting an unknown type of SMART
module based on the serial number.
10.3.2 Error Flags
The eDAQ error flags are set only when the eDAQ detects a serious error. When such
an error occurs the eDAQ automatically resets. If a test run is in progress, a new test
run may start based on the user-specified FCS Reset Options.
BadRequest
The BadRequest error flag indicates that a serious error condition exits on the eDAQ
unit most likely resulting from a hardware failure or a software deficiency. It is unlikely
that this error can result from an operator mistake.
BatteryInterlock
The BatteryInterlock error flag indicates that the backup battery interlock option is
enabled and the backup battery charge or voltage level is below the defined interlock
levels. If a test run is in progress, the test run stops and the eDAQ resets.
CardException
The CardException flag indicates that a type II layer has reported an error status to the
eDAQ main processor. As such, it can have several meanings. The eDAQ writes
additional information to the log file when this occurs.
DeviceOverFlow
The DeviceOverFlow flag indicates that the defined test exceeds the eDAQ units
processing capabilities. This may occur when many channels are taking data at very
high sample rates or large numbers of computed channels are defined. For a thorough
discussion of this problem, see Tips on Eliminating eDAQ OverFlow Errors.
Internal
The Internal error flag indicates that a serious error condition exits on the eDAQ unit
most likely resulting from a hardware failure or a software deficiency. It is unlikely that
this error can result from an operator mistake.
InvalidConnector
The InvalidConnector error flag indicates that a serious error condition exits on the
eDAQ unit most likely resulting from a hardware failure or a software deficiency. It is
unlikely that this error can result from an operator mistake.
I2740-2.1 en 199
SoMat eDAQ
Memory
The Memory flag indicates that the eDAQ has run out of the memory reserved for
eDAQ buffering and other processing tasks. This may occur when many channels are
taking data at very high sample rates or large numbers of computed channels are
defined. For a discussion on how to attempt to alleviate the problem, see Tips on
Eliminating eDAQ OverFlow Errors.
MissedInterrupt
The MissedInterrupt flag indicates that the eDAQ unit is interrupt bound (i.e., it cannot
service data acquisition interrupts fast enough). The only recourse is to reduce the
sample rate for the transducers that generated the missed interrupt.
ParityError
The ParityError flag indicates that there is a unrecoverable inconsistency in a RAM
Disk pointer structure. The RAM Disk pointers are stored in triple redundant fields. If
none of the three pointers are consistent, the eDAQ sets the error flag and resets itself.
It is unlikely that this error can result from an operator mistake.
QueueOverFlow
The QueueOverFlow flag indicates that the defined test exceeds the eDAQ units
processing capabilities. This may occur when many channels are taking data at very
high sample rates or large numbers of computed channels are defined. For a thorough
discussion of this problem, see Tips on Eliminating eDAQ OverFlow Errors.
RAMDiskCorrupt
The RAMDiskCorrupt flag indicates a corruption of the RAM Disk memory. Transfer
any existing test data files to the PC and reformat the RAM Disk. Consider the test data
file suspect.
RingBufInterface
The RingBufInterface error flag indicates that a serious error condition exits on the
eDAQ unit most likely resulting from a hardware failure or a software deficiency. It is
unlikely that this error can result from an operator mistake.
RingBufInvalid
The RingBufInvalid flag indicates that there is an interruption in the incoming data
stream that would result in a missed data sample and the option for an error reset on
this event is enabled. The eDAQ uses this flag only for input data processed using the
ring buffer interface scheme (e.g., vehicle bus data).
TimeOut
The TimeOut error flag indicates that a serious error condition exits on the eDAQ unit
most likely resulting from a hardware failure or a software deficiency. It is unlikely that
this error can result from an operator mistake.
10.4 Corrupt SIF File Data Recovery
NOTE
This topic is applicable to the SIF data format only.
SoMat eDAQ
200 I2740-2.1 en

Data stored in the SIF format can be corrupted in the unlikely event of one or more
power failures during a test run when there is insufficient charge in the backup battery.
Corruption can also occur if the PC Card is removed from the eDAQ with the eDAQ
powered even if a test run is not in progress.
Understanding that these corruptions do happen, HBM does attempt to evaluate and,
if possible, recover SIF data file contents. This is handled on a case-by-case basis and
is subject to a service charge. The SIF component file set (i.e., all of the SIF#####.SIC
files) must be sent intact. There is very limited hope of recovering data from a
consolidated corrupt SIF file alone.
If TCE reports that any test runs have ended abnormally or there is any other reason
to believe that the SIF data file is corrupt (after using the TCE SIC consolidate task),
proceed as follows.
For internal Flash memory or an external PC Card formatted with Linux, the only way
to copy the eDAQ resident SIC files is to use the eDAQ web browser. Select the
Explore eDAQ Files option in the system tab and copy the SIC files under the
/hd/eDAQ folder to the PC. Note that this can be very time consuming if there are a
large number of SIC files.
For a PC Card formatted with MSDOS, remove the PC Card with power turned off and
send the card to HBM customer service. Alternatively, copy the PC Card component
file set to a PC directory and send this to HBM or place it on the HBM FTP site per
arrangement with customer service.
10.5 Tips on Eliminating eDAQ OverFlow Errors
The eDAQ generates a DeviceOverFlow or QueueOverFlow error when the defined
test exceeds the eDAQ units processing capabilities. Following are some suggestions
for test setup changes to avoid a DeviceOverFlow or QueueOverFlow error.
Use integer data types for transducers
Significant improvement in processing throughput can be achieved by using integer
output data types instead of the floating point data type in the transducer channel
definitions. 16-bit integer data requires only half the storage space as 32-bit floating
point data. The main drawback with integer data types is that they are not supported
by all computed channels and DataModes. There is no loss of accuracy when using
the 16-bit integer data type for any of the data sources that originate from eDAQ A/D
converters since these are all 16-bit A/D converters.
Use Engineering Scaler computed channels
If transducer channels that originate as 16-bit integer data types (e.g., ELLB, EHLB,
EHLS and EBRG channels) are used in a Desk Calculator computed channel, it is
usually more efficient to use the 16-bit integer data type in the transducer channel
definition and create an Engineering Scaler computed channel to generate the floating
point data needed for most calculator expressions. The main advantage of this is that
the eDAQ can store the original transducer channel as a 16-bit integer instead of as a
32-bit float. For more information on the Engineering Scaler computed channel, see
Engineering Scaler on page 147.
Use the large pipe frame size option
Using the larger pipe frames significantly improves throughput performance
particularly when there are a large number of transducer and/or computed channels
running at slower sample rates (i.e., 500 Hz or slower). Using the larger pipe frames
I2740-2.1 en 201
SoMat eDAQ
modestly improves throughput performance for most tests with sample rates below or
around 10000 Hz. At sample rates above 10000 Hz, the small pipe frame size option
generally results in the best throughput performance. This option is selectable on a per
test setup basis using the ECPU configuration options (see Pipe Frame Rate on
page 96).
Use the Linux PC Card format option
Using the Linux format significantly improves throughput performance compared to
using the less efficient DOS format. Of course, this is not an option if the PC Card is
to be removed and later consolidated on a Windows-based PC.
Avoid redundant calculations in calculator computed channels
This is illustrated by the following example of an inefficient usage of eDAQ Desk
Calculator computational resources.
Comp_1 = (In_1 + In_2) / sqrt(In_1^2 + In_2^2)
Comp_2 = (In_1 - In_2) / sqrt(In_1^2 + In_2^2)
Here is a much more efficient usage.
Temp_1 = sqrt(In_1^2 + In_2^2)
Comp_1 = (In_1 + In_2) / Temp_1
Comp_2 = (In_1 - In_2) / Temp_1
Also, although probably much less obvious, the Temp_1 expression is more efficient
when written as follows.
Temp_1 = sqrt(In_1 * In_1 + In_2 * In_2)
For more information on the Desk Calculator computed channel, see Desk
Calculator on page 144.
Minimize the number of defined DataModes
For a test with 20 transducer channels defined at the same sample rate, it is much
more efficient to store all 20 channels in a single Time History DataMode, rather than
storing each channel in a separate DataMode. The reason for this is that there is only
one PC Card file opened and manipulated for each Time History DataMode and
having just one file to manipulate is much more efficient than having to manipulate 20
PC Card files at the same time.
Up sample digital input channels used for triggers
Often, a digital input channel is used to manually trigger DataMode storage. If the input
channels are defined for a 2500 Hz sample rate and storage rate, it is more efficient to
define the digital input channel at 100 Hz and then up sample by a factor of 25 to get
to the 2500 Hz sample rate required for the DataMode trigger. For more information
on the Up Sampler computed channel, see Up Sampler on page 166.
Do not use min-max tracking
The enable min-max tracking preference for Time History DataModes is in the TCE
Preferences menu. Min-max tracking can consume significant CPU cycles with a lot of
Time History DataMode storage.
SoMat eDAQ
202 I2740-2.1 en
Use a second eDAQ or eDAQlite in networked mode
If another eDAQ or eDAQlite is available, use it in networked mode with the first eDAQ
and split the processing load as evenly as possible between the two eDAQ systems.
For more information on networking, see Networking eDAQ Systems on page 41
and Networking eDAQ Systems on page 92.
Reduce the scope of the test
As a last resort, reduce the scope of the test by reducing sample rates, reducing
channel counts or eliminating computed channels and DataModes.
I2740-2.1 en 203
SoMat eDAQ
11 Data Types
The eDAQ supports the following data types:
32-bit float
32-bit integer
32-bit unsigned
16-bit integer
16-bit signed
16-bit unsigned
8-bit integer
8-bit signed
8-bit unsigned (logic, bitmap, message)
The following table summarizes the data types supported by each input channel,
computed channel and DataMode.
Category Channel Type Input Data Type Output Data Type
Input Channel Bridge -- 16-bit signed
32-bit float
8-bit signed
Bus-Oriented
Vehicle Bus
GPS
Serial Bus
-- 8-bit unsigned
16-bit unsigned
32-bit unsigned
32-bit float (using conversion)
Digital Input -- 8-bit unsigned (logic)
High Level -- 16-bit signed
32-bit float
8-bit signed
Simultaneous High Level -- 16-bit signed
32-bit float
8-bit signed
Isolated Thermocouple -- 32-bit float
Low Level -- 16-bit signed
32-bit float
8-bit signed
Pulse Counter -- 32-bit float
32-bit unsigned*
32-bit integer*
*limited by selected mode
Simulation File -- 8-bit integer
16-bit integer
32-bit float
Simulation Function Generator -- 8-bit integer
16-bit integer
32-bit float
Simulation Message -- 8-bit unsigned (msg)
Thermocouple -- 32-bit float
SoMat eDAQ
204 I2740-2.1 en
Computed Channel Anomaly Detect 32-bit float 8-bit unsigned (bmp)
Bitmap Trigger 8-bit unsigned (bmp) 8-bit unsigned (logic)
Damage Equivalent Load 32-bit float 32-bit float
Desk Calculator Based on specific operators (below)
sin, cos, tan,
asin, acos, atan,
log, log10,
abs, exp, sgn,
round, floor, ceil,
+,-,*,/,%,^
32-bit float 32-bit float
float 8-bit unsigned (logic) 32-bit float
>,>=,<,<=,==,!= 32-bit float 8-bit unsigned (logic)
!,&&,|| 8-bit unsigned (logic) 8-bit unsigned (logic)
Directional Velocity velocity: 32-bit float
direction:
32-bit float
32-bit integer
32-bit float
Down Sampler all same is input
Engineering Scaler 8-bit integer
8-bit unsigned
16-bit integer
16-bit unsigned
32-bit integer
32-bit unsigned
32-bit float
Fatigue Damage 32-bit float 32-bit float
Integer Scaler 32-bit float 8-bit integer
8-bit unsigned
16-bit integer
16-bit unsigned
32-bit integer
32-bit unsigned
Integrator 32-bit float
32-bit integer
32-bit unsigned
same as input
Interactive Trigger all 8-bit unsigned (logic)
Max Track 32-bit float
16-bit integer
same as input
Min Track 32-bit float
16-bit integer
same as input
Pulse Counter 8-bit unsigned (logic) 32-bit float
Range Track 32-bit float
16-bit integer
32-bit float for 32-bit float input,
16-bit unsigned for 16-bit integer input
Category Channel Type Input Data Type Output Data Type
I2740-2.1 en 205
SoMat eDAQ
Computed Channel
(continued)
Smoothing Filter 32-bit float
16-bit integer
same as input
State Mapper 32-bit float 32-bit float
Statistical Analysis 32-bit float 32-bit float
Test Run Stopper 8-bit unsigned (logic) 8-bit unsigned (logic)
Time Base Shifter all same as input
Time Channel all 32-bit float
32-bit unsigned
Timed Trigger 8-bit unsigned (logic) 8-bit unsigned (logic)
Trigger Generator all 8-bit unsigned (logic)
Triggered Zero Suppression 32-bit float
32-bit integer
32-bit unsigned
same as input
Up Sampler all same is input
Valid Data Gate all 8-bit unsigned (logic)
DataMode Burst History all --
Digital Output 8-bit unsigned (logic) --
Event Slice all --
Message Logger 8-bit unsigned (msg) --
Peak/Valley 8-bit integer
16-bit integer
32-bit float
--
Peak/Valley Matrix 32-bit float
16-bit integer*
*evenly divided bins only
--
Peak/Valley Slice master:
8-bit integer
16-bit integer
32-bit float
slave: all
--
Rainflow 32-bit float
16-bit integer*
*evenly divided bins only
--
Time at Level (1D) 32-bit float
16-bit integer*
*evenly divided bins only
--
Time at Level (mD) 32-bit float
16-bit integer*
*evenly divided bins only
--
Time History all --
Category Channel Type Input Data Type Output Data Type
SoMat eDAQ
206 I2740-2.1 en
I2740-2.1 en 207
SoMat eDAQ
12 Cable Pinouts
12.1 ECPU (Main Processor)
12.1.1 Communications Cable
The eDAQ is compatible with several different communications cables each of which
provide a 26-pin D-Sub connector for connection to the eDAQ Comm port. The
following table lists the communications cables and their connectors.
The 26-pin D-Sub connector has dedicated pins for each type of available connector.
As shown in the diagram below, pins 1-4 are for Ethernet communication, pins 5-9 are
for the networking sync connectors and pins 10-18 correspond to the serial 9-pin
connector.
Figure 12-1: Diagram of the 26-pin D-Sub connector on the communications cables for
connection to the eDAQ.
The following tables list the pinouts for each type of available connector and the
corresponding pin on the 26-pin D-Sub Comm connector.
RJ-45 Ethernet Connector
Communications Cable
Ethernet
(X/O)
Ethernet
(HUB) Serial Sync
1-E-ETHERNET X/O-2 X
1-E-ETHERNET HUB-2 X
1-SAC-ESR9/XO-2 X X
1-SAC-ESR9/HUB-2 X X
1-SAC-ESYNCADAPT-2 X X
1-SAC-ESYNCADAPT-SC-2 X X X
Function
26-Pin
D-Sub
RJ-45
Pin
Wire Color
(X/O)
Wire Color
(HUB)
10/100 BASE-T Receive + 3 3 Orange/White Green/White
10/100 BASE-T Receive - 4 6 Orange Green
10/100 BASE-T Transmit + 2 1 Green/White Orange/White
10/100 BASE-T Transmit - 1 2 Green Orange
SoMat eDAQ
208 I2740-2.1 en
LEMO Networking Connector
9-Pin D-Sub Serial Connector
NOTE
This information is for the current communications cable, which is a fully molded
connector/cable assembly. The original communications cable is not a molded
assembly and differs as follows from the current cable: ground on the serial connector
is white instead of gray and the HUB 10/100BASE-T Receive+ and Transmit+ colors
are white/orange and white/green, respectively.

12.1.2 Power Cable
The SoMat EPWR15 Power Cable (1-EPWR15-2) has a 15-pin D-Sub connector for
connection to the Power port on the eDAQ and two sets of pigtail wires: one for main
power and one for remote power. The following table lists the pinouts for the EPWR15
cable.
NOTE
Though the current EPWR15 cables use only one pin each for power and ground, the
Power connector on the eDAQ can receive + Main Power on pins 1, 2 and 9 and - Main
Power on pins 7, 8 and 15.
Connector Function
26-Pin
D-Sub LEMO Pin Wire Color
Sync 1 Clock + 5 1 Red
Clock - 8 2 Black
Shield 7 3 bare wire
Sync 2 Clock + 6 1 Red
Clock - 9 2 Black
Shield 7 3 bare wire
Function 26-Pin D-Sub Serial Pin Wire Color
CTS (clear to send) 17 7 Yellow
DCD (data carrier detect) 10 4 Red
DSR (data set ready) 15 1 Violet
DTR (data terminal ready) 13 6 Orange
Rx (received) 11 3 Brown
RI (ring indicator) 18 9 Blue
RTS (request to send) 16 8 Green
Tx (transmitted) 12 2 Black
Ground 14 5 Gray
I2740-2.1 en 209
SoMat eDAQ

Pin 3 is jumpered to pin 4.
12.1.3 Digital I/O and Pulse Counter Cable
The SoMat SAC-EDIO Digital I/O Transducer Cable (1-SAC-EDIO-2) for ECPU digital
inputs/outputs and pulse counters has a 44-pin D-Sub connector for connection to the
Digital I/O port on the ECPU and a set of color-coded pigtail wires.
NOTE
There are two versions of this cable that have the same part number, but have different
color coded wires. The newer assembly is a split cable labeled SAC-EDIGIO. The
cable pin outs for the newer cable are in the first table and the cable pin outs for the
older cable are in the second table.

Cable Function Pin Wire Color
Main Power Cable (gray) + Main Power 1 Red
- Main Power 8 Black
Remote Power Control Cable (black) + Remote Power 6 Red
- Remote Power 14 Black
SoMat eDAQ
210 I2740-2.1 en
SAC-EDIO Cable (newer, labeled SAC-EDIGIO)
Function Pin Wire Color Function Pin Wire Color
PC Signal 1 2 Green PC Return 1 1 Black
PC Signal 2 4 Red PC Return 2 3 Gray
PC Signal 3 6 Blue/White PC Return 3 5 Red/White
PC Signal 4 8 Orange PC Return 4 7 Brown
PC Signal 5 10 Pink PC Return 5 9 Orange/White
PC Signal 6 12 White PC Return 6 11 Purple
PC Signal 7 14 Red/Black PC Return 7 13 Green/White
PC Signal 8 16 Purple/White PC Return 8 17 Light Green
I/O Signal 1 24 Green I/O Return 1 23 Black
I/O Signal 2 26 Red I/O Return 2 25 Gray
I/O Signal 3 28 Blue/White I/O Return 3 27 Red/White
I/O Signal 4 30 Orange I/O Return 4 29 Brown
I/O Signal 5 32 Pink I/O Return 5 31 Orange/White
I/O Signal 6 34 White I/O Return 6 33 Purple
I/O Signal 7 36 Red/Black I/O Return 7 35 Green/White
I/O Signal 8 38 Light Green I/O Return 8 37 Purple/White
I/O Signal 9 40 Yellow I/O Return 9 39 Brown/White
I/O Signal 10 42 Black/White I/O Return 10 41 Blue
I2740-2.1 en 211
SoMat eDAQ
SAC-EDIO Cable (older)
12.2 ECOM (Vehicle Communications Layer)
Transducer Cable for Dedicated CAN Interface
The dedicated CAN interface on the ECOM layer uses a SoMat SAC-TRAN-MP
Transducer Cable (1-SAC-TRAN-MP-2-2 or 1-SAC-TRAN-MP-10-2) with an M8
connector and a set of color-coded pigtail wires. The following table lists the pinouts
for the SAC-TRAN-MP cable when used with a dedicated CAN interface on the ECOM
layer.
NOTE
Connection to both the SWC pin and the CAN pins is allowed, but only one source can
be used at any given time.

NOTE
Always provide the +12 volt REF voltage for the SWC interface. For other CAN
interfaces, the red power wire can be used to power transducers with a
user-configurable range of 3 to 24 volts.
Function Pin Wire Color Function Pin Wire Color
PC Signal 1 2 White PC Return 1 1 Black
PC Signal 2 4 Red PC Return 2 3 Green
PC Signal 3 6 Orange PC Return 3 5 Blue
PC Signal 4 8 White/Black PC Return 4 7 Red/Black
PC Signal 5 10 Orange/Black PC Return 5 9 Green/Black
PC Signal 6 12 Blue/Black PC Return 6 11 Black/White
PC Signal 7 14 Red/White PC Return 7 13 Green/White
PC Signal 8 16 Orange/Red PC Return 8 17 Blue/White
I/O Signal 1 24 White I/O Return 1 23 Black
I/O Signal 2 26 Red I/O Return 2 25 Green
I/O Signal 3 28 Orange I/O Return 3 27 Blue
I/O Signal 4 30 White/Black I/O Return 4 29 Red/Black
I/O Signal 5 32 Orange/Black I/O Return 5 31 Green/Black
I/O Signal 6 34 Blue/Black I/O Return 6 33 Black/White
I/O Signal 7 36 Red/White I/O Return 7 35 Green/White
I/O Signal 8 38 Blue/White I/O Return 8 37 Orange/Red
I/O Signal 9 40 Black/Red I/O Return 9 39 White/Red
I/O Signal 10 42 Blue/Red I/O Return 10 41 Red/Green
SoMat eDAQ
212 I2740-2.1 en

12.3 EHLS (High Level Analog Layer)
12.3.1 EHLS Transducer Cable
The EHLS layer uses a SoMat SAC-TRAN-MP Transducer Cable
(1-SAC-TRAN-MP-2-2 or 1-SAC-TRAN-MP-10-2) with an M8 connector and a set of
color-coded pigtail wires. The following table lists the pinouts for the SAC-TRAN-MP
cable when used for an EHLS input.
12.3.2 EHLS Analog Output Cable
The following table lists the pinouts for the SoMat SAC-TRAN-AO Analog Output
Cable (1-SAC-TRAN-AO-2-2) when used with EHLS analog outputs.
Function Pin Wire Color
SWC 1 Brown
CANH 2 White
AGnd 3 bare wire
Power 5 Red
+12 V REF 5 Red (SWC)
CANL 6 Green
Function Pin Wire Color
reserved 1 Brown
+ Signal Input 2 White
Shield 3 bare wire
Ground 4 Black
Power 5 Red
- Signal Input 6 Green
Function Pin Wire Color
1 Out B White/Green
2 Out M Brown
3 Out A Red/Blue
4 Out E Green
5 Out N Pink
6 Out C Gray
7 Out O Yellow
8 Out D Brown/Green
9 Out K Gray/Brown
10 Out U Blue
11 Out L Gray/Pink
I2740-2.1 en 213
SoMat eDAQ
12.4 EBRG (Bridge Layer)
12.4.1 EBRG Transducer Cable
The EBRG layer uses a SoMat SAC-TRAN-MP Transducer Cable (SAC-TRAN-MP)
with an M8 connector and a set of color-coded pigtail wires. The following table lists
the pinouts for the SAC-TRAN-MP cable when used for an EBRG input.
12.4.2 EBRG Analog Output Cable
The following table lists the pinouts for the SoMat SAC-TRAN-AO Analog Output
Cable (SAC-TRAN-AO-2-2) when used with EBRG analog outputs.
12 Out G Black
13 Out T Yellow/Brown
14 Out I White/Gray
15 Out S Purple
16 Out H White/Yellow
Ground P White
Ground R Red
Shield F bare wire
Function Pin Wire Color
Function Pin Wire Color
reserved 1 Brown
+ Signal Input 2 White
Shield/Ground 3 bare wire
- Excitation 4 Black
+ Excitation 5 Red
- Signal Input 6 Green
Function Pin Wire Color
1 Out B White/Green
2 Out M Brown
3 Out A Red/Blue
4 Out E Green
5 Out N Pink
6 Out C Gray
7 Out O Yellow
8 Out D Brown/Green
9 Out K Gray/Brown
10 Out U Blue
SoMat eDAQ
214 I2740-2.1 en
12.5 EDIO (Digital I/O Layer)
Transducer Cable for Digital I/O and Pulse Counter
The EDIO layer uses the SoMat SAC-TRAN-MP Transducer Cable
(1-SAC-TRAN-MP-2-2 or 1-SAC-TRAN-MP-10-2) with an M8 connector and a set of
color-coded pigtail wires. The following table lists the pinouts for the SAC-TRAN-MP
cable when used for EDIO inputs. The I/O pin depends on the bank connector (i.e.,
|1-4|, |5-8| or |9-12|).
NOTE
The quadrature encoder outputs as specified are for default signal polarity which
assigns the positive direction to clockwise rotation. To reverse polarity, interchange
encoder outputs A and B.

11 Out L Gray/Pink
12 Out G Black
13 Out T Yellow/Brown
14 Out I White/Gray
15 Out S Purple
16 Out H White/Yellow
Ground P White
Ground R Red
Shield F bare wire
Function Pin Wire Color
Function Pin Wire Color Quad Encoder Usage
I/O 4, 8 or 12 1 Brown Encoder 2, output B
I/O 3, 7 or 11 2 White Encoder 2, output A
GND/Shield 3 bare wire Return
I/O 1, 5 or 9 4 Black Encoder 1, output A
Power 5 Red Power
I/O 2, 6 or 10 6 Green Encoder 1, output B
I2740-2.1 en 215
SoMat eDAQ
12.6 EHLB (High Level Layer)
12.6.1 EHLB Transducer Cable
The SoMat SAC-EHLB1 EHLB Transducer Cable (1-SAC-EHLB1-2) has a 62-pin
D-Sub connector for connection to the EHLB and a set of color-coded pigtail wires.
NOTE
There are two versions of this cable that have the same part number, but have different
color coded wires. The newer assembly is labeled SE74020-C on the outer PVC
shield. The cable pin outs for the newer cable are in the first table and the cable pin
outs for the older cable are in the second table.

SAC-EHLB1 Cable (newer, labeled E74020-C)
Function Pin Wire Color Function Pin Wire Color
+ Excitation 61 Gray/Red - Excitation 59 Light Blue/Black
1 In 29 Black 1 Ground 49 Brown
2 In 8 Red 2 Ground 7 Orange
3 In 31 Yellow 3 Ground 51 Green
4 In 10 Blue 4 Ground 9 Purple
5 In 33 Gray 5 Ground 53 White
6 In 12 Pink 6 Ground 11 Light Green
7 In 55 Black/White 7 Ground 34 Brown/White
8 In 35 Red/White 8 Ground 56 Orange/White
9 In 14 Green/White 9 Ground 13 Blue/White
10 In 57 Purple/White 10 Ground 36 Red/Black
11 In 37 Orange/Black 11 Ground 58 Yellow/Black
12 In 16 Green/Black 12 Ground 15 Gray/Black
13 In 39 Pink/Black 13 Ground 60 Pink/Green
14 In 18 Pink/Red 14 Ground 17 Pink/Purple
15 In 41 Light Blue 15 Ground 62 Light Blue/Brown
16 In 20 Light Blue/Red 16 Ground 19 Light Blue/Purple
SoMat eDAQ
216 I2740-2.1 en
SAC-EHLB1 Cable (older)
12.6.2 EHLB Transducer Cable with Vehicle Bus
The SoMat SAC-EHLB1-VB EHLB Transducer Cable with Vehicle Bus
(1-SAC-EHLB1-VB-2) has a 62-pin D-Sub connector for connection to the EHLB and
a set of color-coded pigtail wires.
NOTE
There are two versions of this cable that have the same part number, but have different
color coded wires. The newer assembly is labeled SE74020-C on the outer PVC
shield. The cable pin outs for the newer cable are in the first table and the cable pin
outs for the older cable are in the second table.

Function Pin Wire Color Function Pin Wire Color
+ Excitation 61 Red - Excitation 59 Black
1 In 29 White 1 Ground 49 Green
2 In 8 Orange 2 Ground 7 Blue
3 In 31 Brown 3 Ground 51 Yellow
4 In 10 Purple 4 Ground 9 Gray
5 In 33 Pink 5 Ground 53 Tan
6 In 12 Red/Green 6 Ground 11 Red/Yellow
7 In 55 Red/Black 7 Ground 34 White/Black
8 In 35 White/Red 8 Ground 56 White/Green
9 In 14 White/Yellow 9 Ground 13 White/Blue
10 In 57 White/Brown 10 Ground 36 White/Orange
11 In 37 White/Gray 11 Ground 58 White/Purple
12 In 16 White/Red/Blue 12 Ground 15 White/Black/Green
13 In 39 White/Black/Yellow 13 Ground 60 White/Black/Blue
14 In 18 White/Black/Brown 14 Ground 17 White/Black/Orange
15 In 41 White/Black/Gray 15 Ground 62 White/Black/Purple
16 In 20 White/Black/Black 16 Ground 19 White/Red/Green
I2740-2.1 en 217
SoMat eDAQ
SAC-EHLB1-VB Cable (newer, labeled E74020-C)
SAC-EHLB1-VB Cable (older)
12.7 ELLB (Low Level Layer)
12.7.1 ELLB Transducer Cable
The following table lists the pinouts for the SoMat 4-wire SAC-EXDUC ELLB
Transducer Cable and the SoMat 6-wire SAC-EXDUC-6-V ELLB Transducer Cable.
Input Cable
The calibration inputs apply only to the 6-wire SAC-EXDUC-6-V cable.
NOTE
For a quarter bridge configuration only, wire colors for + Excitation and - Signal are
reversed.

Function Pin Wire Color Function Pin Wire Color
CANL 1 Black K-Line 4 Red
CANH 23 Brown L-Line 44 Light Green
AGnd 26 Pink AGnd 48 Black/White
SWC_bus 24 Orange +12 V 45 Brown/White
AGnd 46 Yellow CCD+ 5 Red/White
VPW_bus 2 Green CCD- 25 Orange/White
AGnd 47 Blue AGnd 30 Green/White
AGnd 27 Purple PWM_bus+ 22 Blue/White
ALDL_bus 3 Gray PWM_bus- 43 Purple/White
AGnd 28 White AGnd 32 Red/Black
Function Pin Wire Color Function Pin Wire Color
CANL 1 Black K-Line 4 Black/White
CANH 23 White L-Line 44 Blue/Black
AGnd 26 Green AGnd 48 Green/White
SWC_bus 24 Red +12 V 45 Red/White
AGnd 46 Blue CCD+ 5 Orange/Red
VPW_bus 2 Orange CCD- 25 Blue/White
AGnd 47 Red/Black AGnd 30 White/Red
AGnd 27 White/Black PWM_bus+ 22 Black/Red
ALDL_bus 3 Green/Black PWM_bus- 43 Red/Green
AGnd 28 Orange/Black AGnd 32 Blue/Red
SoMat eDAQ
218 I2740-2.1 en
Analog Out Cable
Analog out is provided with the SAC-EXDUC-6-V cable only.
12.7.2 ELLB M8 Connector Option
The following table lists the pinouts for the ELLB M8 input connectors option.
Transducer Cable
NOTE
For a quarter bridge configuration only, wire colors for + Excitation and -Signal are
reversed.

Function 1/5 Pin 2/6 Pin 3/7 Pin 4/8 Pin Wire Color
+ Excitation 35 13 28 6 Red
+ Signal 16 31 9 24 White
+ Calibration 34 12 27 5 Blue
Ground 17 32 10 25 shield
- Excitation 15 30 8 23 Black
- Signal 33 11 26 4 Green
- Calibration 14 29 7 22 Brown
Function Pin Wire Color Function Pin Wire Color
Volt Out 1/5 19 Brown Ground 1/5 18 Black
Volt Out 2/6 37 Red Ground 2/6 36 Green
Volt Out 3/7 2 Orange Ground 3/7 3 White
Volt Out 4/8 20 Yellow Ground 4/8 21 Blue
Ground 1 shield
Function Pin Wire Color
reserved 1 Brown
+ Signal Input 2 White
Shield 3 bare wire
- Excitation 4 Black
+ Excitation 5 Red
- Signal Input 6 Green
I2740-2.1 en 219
SoMat eDAQ
Analog Out Cable
The analog output cable is optional.
12.8 Vehicle Bus Modules (VBM)
The vehicle bus modules use the SoMat SAC-TRAN-MP Transducer Cable
(1-SAC-TRAN-MP-2-2 or 1-SAC-TRAN-MP-10-2) with an M8 connector and a set of
color-coded pigtail wires. The following sections list the pinouts for the SAC-TRAN-MP
cable when used with each available VBM interface.
12.8.1 Transducer Cable for VPW Interface
The following table lists the pinouts for the SAC-TRAN-MP cable when used with the
VPW interface.
NOTE
Always provide the +12 volt REF voltage for the VPW module to function.

Function Pin Wire Color
Ground P White
Analog 1 Out B White/Green
Analog 2 Out M Brown
Analog 3 Out A Red/Blue
Analog 4 Out E Green
Analog 5 Out N Pink
Analog 6 Out C Gray
Analog 7 Out O Yellow
Analog 8 Out D Brown/Green
Shield F bare wire
Function Pin Wire Color
VPW_bus 2 White
AGnd 3 bare wire
+12 V REF 5 Red
SoMat eDAQ
220 I2740-2.1 en
12.8.2 Transducer Cable for J1708/LIN BUS Interface
The following table lists the pinouts for the SAC-TRAN-MP when used with the
J1708/LIN interface. Connect to either the LIN_BUS pin or the J1708 pins but not both.
NOTE
Always provide the +12 volt REF voltage for the J1708/LIN module to function.

12.8.3 Transducer Cable for CAN/SWC Interface
The following table lists the pinouts for the SAC-TRAN-MP cable when used with the
CAN/SWC interface
NOTE
Connection to both the SWC pin and the CAN pins is allowed, but only one source can
be used at any given time.

NOTE
SWC operation is restricted to the EMCAN.04 version of the CAN VBM.

NOTE
Always provide the +12 volt REF voltage for the SWC interface.

Function Pin Wire Color
LIN_BUS 1 Brown
J1708_A 2 White
AGnd 3 bare wire
+12 V REF 5 Red
J1708_B 6 Green
I2740-2.1 en 221
SoMat eDAQ
12.8.4 Transducer Cable for ISO9141/KW2000 Interface
The following table lists the pinouts for the SAC-TRAN-MP cable when used with the
ISO9141/KW2000 interface.
NOTE
Always provide the VBAT+ voltage for the ISO9141/KW2000 module to function.

Function Pin Wire Color
SWC 1 Brown
CANH 2 White
AGnd 3 bare wire
Power 5 Red
+12 V REF 5 Red (SWC)
CANL 6 Green
Function Pin Wire Color
ISO9141 K-Line 2 White
AGnd 3 bare wire
VBAT+ 5 Red
ISO9141 L-Line 6 Green
SoMat eDAQ
222 I2740-2.1 en
I2740-2.1 en 223
SoMat eDAQ
13 Device Wiring
The following sections provide device wiring diagrams for all applicable layer types. For
more information on using each transducer, see eDAQ Hardware on page 95 and
Input Channels on page 117. For complete pinouts for the cables used in the
following sections, see Cable Pinouts on page 207.
13.1 ECPU (Base Processor)
13.1.1 ECPU Digital Input
Use the SoMat SAC-EDIO Digital I/O Transducer Cable (1-SAC-EDIO-2) to wire
ECPU digital inputs.
Preferred Switch
Whenever possible, a single-pole, double-throw switch, wired as shown below, should
be used for switched inputs. This circuit solidly switches the input line to either ground
or +5 volts and prevents coupling of the input line to other digital input lines. Moving
the switch to the ground side is identified as FALSE
Figure 13-1: Wiring diagram for the preferred SPDT switch configuration.
Alternate Switch
The following diagram shows the circuit wiring for an alternate digital input involving a
switch closure function. An open switch as shown is TRUE; a closed switch is FALSE.
This circuit is adequate for most applications.
Figure 13-2: Wiring diagram for the alternate SPST switch configuration.
13.1.2 ECPU Digital Output
Use the SoMat SAC-EDIO Digital I/O Transducer Cable (1-SAC-EDIO-2) to wire
ECPU digital outputs.
+
-
5 V
/O Signal
/O Return
ECPU
SAC-EDO
/O
/O Signal
/O Return
ECPU
SAC-EDO
/O
SoMat eDAQ
224 I2740-2.1 en
Operating a Light Emitting Diode (LED)
The following diagram shows the use of an LED as an indicator in the digital output
circuit. A logical FALSE causes the diode to light. The total of all diode currents must
be less than 250 mA for the ECPU. The resistor R limits the current through the diode
when the LED is on. For more information on output current limitations, refer to the
ECPU-PLUS data sheet.
Figure 13-3: Wiring diagram for using an LED as a digital output.
13.2 EDIO (Digital I/O Layer)
13.2.1 EDIO Digital Input
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire EDIO digital inputs.
Preferred Switch
Whenever possible, a single-pole, double-throw switch, wired as shown below, should
be used for switched inputs. This circuit solidly switches the input line to either ground
or +5 volts and prevents coupling of the input line to other digital input lines. Moving
the switch to the ground side is identified as FALSE.
Figure 13-4: Wiring diagram for the preferred switch configuration on an EDIO input.
Alternate Switch
The following diagram shows the circuit wiring for an alternate digital input involving a
switch closure function. An open switch as shown is TRUE; a closed switch is FALSE.
This circuit is adequate for most applications.
/O Signal
R
+
-
5 V
ECPU
SAC-EDO
/O
Power (+5 V)
/O Signal
GND/Shield
(red)
EDO
SAC-TRAN-MP
/O
I2740-2.1 en 225
SoMat eDAQ
Figure 13-5: Wiring diagram for the alternate switch configuration on an EDIO input.
13.2.2 EDIO Digital Output
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire EDIO digital outputs.
Operating a 12-volt Incandescent Bulb
The following diagram shows an incandescent bulb (3 watts maximum) used as an
indicator in the digital output circuit. An external 12-volt DC power supply provides
power for the bulb. A three-watt bulb uses the current capacity of all lines in an ELDIO
bank. The light turns on when the output is set to FALSE.
Figure 13-6: Wiring diagram for using an incandescent bulb on an EDIO output.
Operating a Light Emitting Diode (LED)
The following diagram shows the use of an LED as an indicator in the digital output
circuit. A FALSE output causes the diode to light. The total of all diode currents must
be less than 250 mA for the an EDIO bank. The resistor R limits the current through
the diode when the LED is on. For more information on output current limitations, refer
to the EDIO data sheet.
/O Signal
GND/Shield
EDO
SAC-TRAN-MP
/O
GND/Shield
+
-
Light
(3W max)
12 V
/O Signal
EDO
SAC-TRAN-MP
/O
SoMat eDAQ
226 I2740-2.1 en
Figure 13-7: Wiring diagram for using an LED on an EDIO output.
13.3 EHLS (High Level Analog Layer)
13.3.1 EHLS Analog Input
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire EHLS analog inputs.
NOTE
Do not use this wiring diagram for EBRG, ELLB or EHLB channels.

Figure 13-8: Wiring diagram for a standard analog input on an EHLS layer.
CAUTION
If the eDAQ chassis is not grounded sufficiently, connect the black Ground wire to the
green -Signal wire at the negative terminal of the voltage source. Leave the bare shield
wire unconnected and assure it does not contact any other surface by either protecting
it or trimming it close to the wire insulation. When using non-HBM extending cables,
attach the shield to the shield of the extending wire, but leave the shield extension
unconnected. Failure to follow this procedure may result in damage to the EHLS
during a high-voltage surge.

Power (+5 V)
/O Signal
R
(red)
EDO
SAC-TRAN-MP
/O
+ Signal
- Signal
(white)
(green)
+
-
V
EHLS
SAC-TRAN-MP
I2740-2.1 en 227
SoMat eDAQ
13.3.2 SMSTRB4 (Strain SMART Module)
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire SMSTRB4 inputs. The following diagrams are also
applicable to older SMART bridge modules that support one fixed bridge type.
Figure 13-9: Wiring diagram for a full-bridge configuration using a Strain SMART Module.
Figure 13-10: Wiring diagram for a half-bridge configuration using a Strain SMART Module.
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Signal
(white)
SMSTRB4
EHLS
SAC-EXT-MF SAC-TRAN-MP
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
SMSTRB4
EHLS
SAC-EXT-MF SAC-TRAN-MP
SoMat eDAQ
228 I2740-2.1 en
Figure 13-11: Wiring diagram for a quarter-bridge configuration using a Strain SMART
Module.
NOTE
For the SMSTRB4, the brown lead wire is routed to the internal completion resistor.
For the older fixed quarter-bridge SMART modules (i.e., modules with serial numbers
starting with SMSTRQB), the white lead wire is routed to the internal completion
resistor.

13.4 EBRG (Bridge Layer)
13.4.1 EBRG Bridge Transducers
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire EBRG bridge transducer inputs.
Figure 13-12: Wiring diagram for a full-bridge configuration on an EBRG layer.
+ Excitation
- Signal
to internal
completion resistor
(red)
(green)
(brown)
SMSTRB4
EHLS
SAC-EXT-MF SAC-TRAN-MP
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Signal
(white)
EBRG
SAC-TRAN-MP
I2740-2.1 en 229
SoMat eDAQ
Figure 13-13: Wiring diagram for a half-bridge configuration on an EBRG layer.
Figure 13-14: Wiring diagram for a quarter-bridge configuration on an EBRG layer.
13.4.2 EBRG Analog Input
Use the SoMat SAC-TRAN-MP Transducer Cable (1-SAC-TRAN-MP-2-2 or
1-SAC-TRAN-MP-10-2) to wire EBRG analog inputs.
NOTE
Do not use this wiring diagram for EHLS channels.

+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
EBRG
SAC-TRAN-MP
+ Excitation
- Signal
to internal
completion resistor
(red)
(green)
(brown)
EBRG
SAC-TRAN-MP
SoMat eDAQ
230 I2740-2.1 en
Figure 13-15: Wiring diagram for a standard analog input on an EBRG layer.
13.5 EHLB (High Level Layer)
Use the SoMat SAC-EHLB1 EHLB Transducer Cable (1-SAC-EHLB1-2) to wire EHLB
inputs.
NOTE
Do not use this wiring diagram for the EHLS channels.

Figure 13-16: Wiring diagram for an EHLB input.
+ Signal
- Signal
(white)
(green)
+
-
V
(bare)
Shield/Ground
EBRG
SAC-TRAN-MP
n
Ground
+
-
V
EHLB
SAC-EHLB1
I2740-2.1 en 231
SoMat eDAQ
13.6 ELLB (Low Level Layer)
13.6.1 ELLB Bridge Four-Wire Option
Use the 4-wire SAC-EXDUC ELLB Transducer Cable (1-SAC-EXDUC-2) for shunt
calibrations where the shunt resistors are installed directly across excitation and signal
leads in the eDAQ unit. Corrections for leadwire resistance must be considered during
shunt calibration.
NOTE
Connect the shield drain wire in transducer cables to circuit ground at the eDAQ end
of the cables.

Figure 13-17: Wiring diagram for a full-bridge transducer on the ELLB layer using the four-wire
cable.
Figure 13-18: Wiring diagram for a half-bridge transducer on the ELLB layer using the
four-wire cable.
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Signal
(white)
ELLB
SAC-SLXDUC
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
ELLB
SAC-SLXDUC
SoMat eDAQ
232 I2740-2.1 en
Figure 13-19: Wiring diagram for a quarter-bridge transducer on the ELLB layer using the
four-wire cable.
13.6.2 ELLB Bridge Six-Wire Option
Use the 6-wire SAC-EXDUC-6-V ELLB Transducer Cable (1-SAC-EXDUC-6-V-2) for
shunt calibrations where the shunt resistors are installed across the two extra wires
provided; those wires are connected to one leg of the bridge. Leadwire resistance
compensation is not an issue when the shunt calibration is done.
NOTE
Connect the shield drain wire in transducer cables to circuit ground at the eDAQ end
of the cables.

+ Excitation
- Signal
to internal
completion resistor
(green)
(red)
(white)
ELLB
SAC-SLXDUC
I2740-2.1 en 233
SoMat eDAQ
Downscale Calibrations
Figure 13-20: Wiring diagram for a full-bridge transducer on the ELLB layer using the six-wire
cable and downscale calibration.
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Signal
(white)
+ Calibration
(blue)
- Calibration
(brown)
ELLB
SAC-SLXDUC-6
SoMat eDAQ
234 I2740-2.1 en
Figure 13-21: Wiring diagram for a half-bridge transducer on the ELLB layer using the six-wire
cable and downscale calibration.
Figure 13-22: Wiring diagram for a quarter-bridge transducer on the ELLB layer using the
six-wire cable and downscale calibration.
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Calibration
(blue)
- Calibration
(brown)
ELLB
SAC-SLXDUC-6
+ Excitation
- Signal
to internal
completion resistor
(green)
(red)
(white)
+ Calibration
(blue)
- Calibration
(brown)
ELLB
SAC-SLXDUC-6
I2740-2.1 en 235
SoMat eDAQ
Upscale Calibrations
Figure 13-23: Wiring diagram for full-bridge transducer on the ELLB layer using the six-wire
cable and upscale calibration.
Figure 13-24: Wiring diagram for half-bridge transducer on the ELLB layer using the six-wire
cable and upscale calibration.
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
- Calibration
(brown)
+ Calibration
(blue)
+ Signal
(white)
ELLB
SAC-SLXDUC-6
+ Excitation
- Signal
- Excitation
(red)
(green)
(black)
+ Calibration
(blue)
- Calibration
(brown)
ELLB
SAC-SLXDUC-6
SoMat eDAQ
236 I2740-2.1 en
13.6.3 ELLB Analog Input
The following wiring diagram is applicable for ELLB layer transducer channels.
NOTE
Do not use this wiring diagram for the EHLS transducer channels.

Figure 13-25: Wiring diagram for standard analog input on an ELLB layer.
+ Signal
- Signal
(white)
(green)
+
-
V
Ground
(shield)
ELLB
SAC-SLXDUC
I2740-2.1 en 237
SoMat eDAQ
14 Data Synchronization
This section describes the limitations on the synchronization of the data samples.
eDAQ data acquisition synchronization across channels is accomplished by using a
single master clock source that drives the data acquisition hardware. The term lag
indicates that, in a Time History plot, the data appears later than it should while the
term lead indicates that the data appears earlier than it should.
NOTE
Unless otherwise noted, the following discussion and numerical examples assume a
100000 Hz master clock rate.

14.1 Data Synchronization Characterization Method
To characterize eDAQ data synchronization, a 5000-millivolt triangle function
generator waveform is fed in parallel into all channels to be characterized. The
frequency of the waveform is set at the sample rate divided by 1000 to yield 1000
sample points per cycle. For each reversal, all data samples that fall between 2000
millivolts are least squares fit to provide a very accurate measurement of the zero
crossing time. The differences in these zero crossing times from one channel to the
next represent the data skew from one channel to the next. For each test run, the data
skew on at least 200 consecutive reversals is measured and then averaged. At least
3 test runs are performed and the average data skew over the set of test runs is the
characterized data skew value.
14.2 Analog Channel Synchronization
The ELLB, EHLS and EBRG channels all employ pre-start periods to compensate for
their analog guard filters. In addition to the guard filter skew, there are some other
secondary factors that influence data synchronization, such as A/D converter
conversion time and transport delays through gain amplifiers.
NOTE
This discussion assumes no digital filtering. Ideally, linear phase digital filters do not
result in phase shifts. For the EHLS and EBRG channels, however, the linear phase
filters for sample rates at or below 10000 Hz result in a five microsecond lead data
skew. The Butterworth digital filters are designed to match their analog equivalents
and, therefore, these filters do generate significant phase shifts which, in turn,
significantly affect synchronization with other transducer channels.

Following is a table that contains actual data skew characterization test results (in
microseconds) for one eDAQ stack. The data in this table is consistent with the data
skew times discussed in this section. The first channel on the first EHLS layer was
arbitrarily used as the data sync time reference channel. The test covered the first four
channels on two EHLS layers, the first four channels on one EBRG layer, the first four
SoMat eDAQ
238 I2740-2.1 en
channels on one ELLB layer and the first four channels on one EHLB layer. Where
applicable, the data sync was characterized using three different sample rates for both
the 100 kHz and the 98.304 kHz master sample rates.
14.2.1 EHLS and EBRG Channel Synchronization
For EHLS and EBRG channels, the relative data synchronization across all channels
in any given eDAQ stack is typically within a few microseconds. All of these channels
use the same type of Butterworth 8-pole analog guard filter, which produces a delay
of around 42 microseconds (2 microseconds). The eDAQ compensates for this delay
by using a fixed value of 40 microseconds for the 100 kHz MSR to pre-start digital data
sampling and align the digital data as close as possible to the actual sample rate clock.
Following is a histogram showing a typical distribution of data skews in microseconds
for all EHLS channels and a variety of sample rates. Note that the data skew for all
channels at all sample rates is less than one microsecond, which is typical for both
EHLS and EBRG layers in general.
Channel
Sample Rate (Hz)
25000 10000 2500 32768 8192 2048
HLSS_1.c01 0.00 0.00 0.00 0.00 0.00 0.00
HLSS_1.c02 0.37 0.37 0.37 0.37 0.40 0.38
HLSS_1.c03 -0.09 -0.10 -0.05 -0.09 -0.07 -0.06
HLSS_1.c04 -0.08 -0.09 -0.09 -0.09 -0.07 -0.05
HLSS_2.c01 0.11 0.14 0.21 0.10 0.15 0.05
HLSS_2.c02 0.16 0.17 0.19 0.15 0.23 0.16
HLSS_2.c03 0.12 0.14 0.17 0.11 0.16 0.11
HLSS_2.c04 0.31 0.32 0.37 0.30 0.33 0.30
Brg_1.c01 1.65 1.64 1.68 1.60 1.60 1.57
Brg_1.c02 1.55 1.54 1.59 1.50 1.49 1.46
Brg_1.c03 1.42 1.42 1.45 1.38 1.37 1.38
Brg_1.c04 1.57 1.57 1.63 1.52 1.49 1.55
LoLev_1.c01 -- 11.50 11.57 -- -64.30 -64.47
LoLev_1.c02 -- 10.69 10.75 -- -65.11 -65.24
LoLev_1.c03 -- 11.72 11.81 -- -64.06 -64.22
LoLev_1.c04 -- 13.15 13.22 -- -62.68 -62.77
HiLev_1.c01 -- -- -2.61 -- -- -12.42
HiLev_1.c02 -- -- -25.79 -- -- -35.54
HiLev_1.c03 -- -- -48.75 -- -- -58.52
HiLev_1.c04 -- -- -71.75 -- -- -81.52
I2740-2.1 en 239
SoMat eDAQ
Figure 14-1: Typical data skew distribution of 64 EHLS channels for several sample rates.
14.2.2 ELLB Channel Synchronization
The ELLB channels have a 5-pole Butterworth guard filter, which creates a time lag of
approximately 315 microseconds (15 microseconds). The eDAQ compensates for
this delay by using a fixed value of 300 microseconds for the 100 kHz MSR to pre-start
data sampling and align the digital data as close as possible to the actual sample rate
clock.
For a typical ELLB layer, the worst case channel-to-channel variation in data skew is
less than five microseconds. This is significantly more than the channel-to-channel
variations seen on EHLS and EBRG channels (which are typically less than one
microsecond). The reason for this is that the ELLB analog guard filters have a much
lower low-pass attenuation frequency (around 2.2 kHz compared to around 25.0 kHz)
and, as a result, exhibit more phase shift variation on a channel-to-channel basis.
14.2.3 EHLB Channel Synchronization
The EHLB layer has only one A/D converter and no analog guard filter. The 16 input
channels are run through a multiplexer ahead of the A/D converter resulting in only the
first channel (c01) being in close data sync to the sample clock and the other analog
channels. There is an approximate 23-microsecond delay from one EHLB channel to
the next, which results in the last channel (c16) lagging the first channel (c01) by about
350 microseconds.
NOTE
The EHLB analog channels consistently lag all other channels by one sample period
on about one out of every ten test runs. The channels are in sync for the other nine
runs.

SoMat eDAQ
240 I2740-2.1 en
14.3 Digital Channel Synchronization
The ECPU and EDIO digital input channels are synchronized to the analog channels
as closely as possible. The eDAQ reads the state of the digital input status register for
each digital channel on each edge of the sample clock signal (i.e., when the analog
channel A/D converters are read). However, because the digital status registers are
updated when a digital input channel changes states, the precise time when a digital
input channel changes state is, in general, somewhere in between sample clock edges
and hence is not known exactly. Because of this, the digital input channels are
expected to lag the analog channels by about half of the sample period on average.
NOTE
The ECPU digital input channels consistently lag all other channels by one sample
period on about one out of every ten test runs. The channels are in sync for the other
nine runs.

14.4 Resampled Channel Synchronization
Resampled channels include vehicle bus, serial bus, GPS and thermocouple channel
inputs. The common aspect of all of these channels is that the data is not sourced from
the MSR clock. As such, the data synchronization of these channels to the channels
that are sourced from the eDAQ MSR is always somewhat less deterministic.
The major issue in dealing with these channels is referred to as resampling. In general,
when the eDAQ reads and time stamps the data samples, the time stamps fall
somewhere between eDAQ sample periods. For example, for a thermocouple channel
output at 1.0 Hz, the input data samples almost always have fractional time stamps
such as 1.345 seconds or 3.360 seconds. The eDAQ runs its resampling algorithm to
generate data outputs (at one second intervals in this example).
While the specific details of the current resampling algorithm are beyond the scope of
this document, the general characteristics are as follows. First, the resampling function
is biased towards introducing a synchronization lead (i.e., the resampled time is
always less than or equal to the time stamp time). In the example case, the data output
associated with the 1.0 second time slot is set with the last data sample that has a time
stamp of at least 1.0 seconds and less than 2.0 seconds. Because of this, the
resampled channels can lead by up to one full sample period. If the data samples are
sourced at a much higher rate than the resampled output rate (e.g., 50 Hz to 1 Hz),
then the synchronization lead will be almost one full second consistently.
14.4.1 Bus-Oriented Channel Synchronization
The vehicle bus, serial bus, and GPS messages are time stamped as they are
received by the eDAQ. The time stamps are synchronized to the same eDAQ MSR
clock used for all other inputs. As such, the inherent skew (always a lag) for vehicle bus
inputs is dependent on how much time elapses between the actual data sampling on
the vehicle computer(s) and the time it takes for the vehicle bus message to be posted
by the source processor and read and time stamped by the eDAQ.
I2740-2.1 en 241
SoMat eDAQ
14.4.2 Thermocouple Channel Synchronization
The ENTB and EITB channels source from a clock on these layers that is not
synchronized to the eDAQ MSR clock. There is a latency of about 70 milliseconds
between the actual time the data is sampled and the time the data is made available
to the eDAQ (for reading and time stamping).
14.5 Analog Output Synchronization
Based on experimental testing, the data skew between ELLB and EHLS or EBRG
analog outputs is very consistent at about 220 to 230 microseconds, with ELLB
channels lagging the EHLS and EBRG channels. This is very close to what is ideally
expected based on the following factors.
The ELLB guard filter generates a time delay of about 300 to 350 microseconds.
The EHLS or EBRG guard filter generates a time delay of about 40
microseconds. There is a 10-20 microsecond delay in loading the EHLS or
EBRG A/D converter data into the analog output D/A converter and about
another 40 microsecond transport delay in the D/A smoothing filter. The total
delay is about 90 to 100 microseconds.
Following is typical test data acquired by inputting a 500 Hz sine wave into both EHLS
and ELLB channels and then measuring the analog outputs using another eDAQ. The
time axis (x-axis) is divided into 1000 microsecond spans. The EBRG measurements
are identical to the EHLS results.
Figure 14-2: Measured data skew between ELLB and EHLS channels.
SoMat eDAQ
242 I2740-2.1 en
14.6 Networked eDAQ System Synchronization
14.6.1 Hardwired Network Synchronization
Master Mode
For a set of hardwired networked eDAQ systems, the data acquired on all of the slave
nodes lead the data acquired on the master node by approximately one to two
microseconds. The reason for this is that there is a one to two microsecond delay in
the propagation of the sample clock signal from the master to the slaves.
GPS Master Mode
When using the GPS master network mode, the slave data channels lead the master
by the following:
EDIO GPS clock, 100-kHz MSR - 90-microsecond lead time
EDIO GPS clock, 98.304-kHz MSR - 112-microsecond lead time
ECOM GPS clock, 100 kHz-MSR - variable amount (not deterministic)
ECOM GPS clock, 98.304-kHz MSR - variable amount (not deterministic)
Because of these limitations on GPS master data synchronization, it is recommended
to use the GPS master mode with EDIO GPS clock generation only at low sample
rates on the order of 100 Hz and to not use the GPS Master mode with ECOM GPS
clock generation under any circumstances.
14.6.2 Wireless Network Synchronization
For wireless eDAQ networking using a GPS timing signal, test results for the accuracy
of the synchronization show that data can be synchronized to 0.1 milliseconds or
better assuming all systems maintain consistent GPS lock. If an eDAQ loses GPS lock
for only a short period of time (i.e., 10 minutes or less), then the synchronization is still
maintained to within 1.0 milliseconds or better as long as there are no sudden or
significant temperature changes in the eDAQ GPS hardware.
I2740-2.1 en 243
SoMat eDAQ
15 Digital Filtering
The following sections provide information on the user-configurable digital filtering
available for ELLB, EHLS and EBRG channels. For information on the analog filtering
for each layer, refer to layer data sheet.
15.1 Signal Aliasing
In the process of converting analog input signals to digital data representations, signal
aliasing can occur if the digital sample rate is too low compared to the frequency
content of the analog signal. This is often referred to as under sampling the analog
signal. This section discusses how the eDAQ handles aliasing.
The eDAQ has analog guard filters that work in combination with user selectable digital
filters to provide low pass filters that limit the frequency content of the digitized signal.
Furthermore, if an anti-aliasing filter is selected, this filtering guarantees that the
digitized signal is not aliased by higher frequency content components of the analog
signal. In other words, the digitized signal accurately represents all frequency content
of the analog signal below the nominal low pass filter cut-off value). Note that the
analog and digital filters do not have infinitely sharp low pass characteristics. The
amount of filter attenuation as a function of frequency is highly dependent on the
type(s) of digital filters used.
Use of these filters is most critical for low-level signal conditioning (e.g., for low level
Strain SMART Module channels). Low-level signal conditioners are more susceptible
to both eDAQ external and eDAQ internal electronic noise aliasing, since the strain
signals are typically in the millivolt range. The signal conditioner gain amplifiers amplify
the noise components as well as the actual strain signal components. In harsh
electromagnetic interference (EMI) environments, the noise contributions can even be
larger in magnitude than the actual strain signal contributions. Fortunately, these EMI
contributions often have much higher frequency content than the actual strain
contributions and can therefore be eliminated with the use of the appropriate analog
and digital filters.
Note that there are situations where the EMI frequency content is in the same range
as the actual signal frequency content. One classic example of this is 60 Hz AC power
line noise induction. The analog and digital filters cannot eliminate this type of signal
corruption, which is not aliasing in the strict definition. In this scenario, the 60 Hz noise
must be eliminated before it enters the eDAQ signal conditioner.
All of the above discussion on the use of anti-aliasing filters to ensure that the digital
data acquired accurately represents the input signal refers to accurately representing
the frequency content of the input signal. It by no means ensures that the digital data
will represent the input signal in terms of providing accurate peak-valley data that is
critical to time domain analyses (such as fatigue analysis). In fact, to get peak-valley
data that is guaranteed to provide 1% amplitude accuracy, the sample rate must be
over 20 times the maximum frequency content of the input signal.
15.2 Digital Filter Characteristics
TCE provides two types of digital filters for analog input channels. One type emulates
an eight-pole, analog Butterworth filter. The second type is an equiripple, linear-phase,
finite impulse response (FIR) digital filter.
SoMat eDAQ
244 I2740-2.1 en
The linear-phase filter provides superior performance and is recommended over the
Butterworth filter. Use the Butterworth filters when it is required to match results with
other test systems.
The characteristics of these filters are shown in the following sections according to the
input channel type.
15.2.1 EHLS and EBRG Digital Filters
Butterworth Eight-Pole Filter
The Butterworth digital filter closely matches the attenuation and step response
characteristics of a conventional analog Butterworth filter. The magnitude, phase and
step responses are shown below.
Figure 15-1: Magnitude response of an approximate eight-pole Butterworth filter.
The -3 dB frequency (break frequency) is 1500 Hz. The sharper than exact roll off in
the transition band is achieved by filtering the data stream using linear phase filters
before applying the approximate Butterworth filter.
0.01 0.1 1 10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
nput Frequency (kHz)
M
a
g
n
i
t
u
d
e

(
d
B
)
10
Theoretical
FR Approximation
-3 dB
I2740-2.1 en 245
SoMat eDAQ
Figure 15-2: Phase response of an approximate eight-pole Butterworth filter
Note that the phase error is reasonably small up to the break frequency (1500 Hz). The
phase match between any two EHLS channels using this filter is exact.
0.01 0.1 1 10
-100
-200
-300
-400
-500
-600
nput Frequency (kHz)
P
h
a
s
e

A
n
g
l
e

(
d
e
g
r
e
e
s
)
0
Theoretical
FR Approximation
SoMat eDAQ
246 I2740-2.1 en
Figure 15-3: Unit step response of an eight-pole Butterworth filter approximated by a
35-coefficient FIR filter.
The unit step response closely resembles that of an analog Butterworth filter.
Linear-Phase Filter
The linear phase filter is designed using the well-known Remez algorithm. This filter
provides a much sharper attenuation curve than the corresponding curve for the
Butterworth filter. Notice that a linear phase filter with a roll-off start frequency of 1000
Hz at a 2500 samples per second sample rate is provided for compatibility with the
similar low level layer sample rate and filter combination.
0 20 40 60
1.2
1
0.8
0.6
0.4
0.2
0
Sample Number
F
i
l
t
e
r

R
e
s
p
o
n
s
e
1.4
Theoretical
FR Approximation
10 30 50
I2740-2.1 en 247
SoMat eDAQ
Figure 15-4: Frequency response of a typical equiripple, linear-phase FIR filter.
The filter used for the frequency response is a 37-tap filter used twice to achieve 96 dB
attenuation in the stop bands. The response is calculated for a sample frequency of
10 Hz, the roll-off start frequency is 3.33 kHz, and the noise floor begins at 6.667 kHz.
0.01 0.1 1 100
0
-20
-40
-60
-80
-100
-120
nput Frequency (kHz)
M
a
g
n
i
t
u
d
e

(
d
B
)
20
10
-3 dB
-96 dB
SoMat eDAQ
248 I2740-2.1 en
Figure 15-5: Unit step response of a typical linear-phase filter achieved by using a 37-tap
equiripple FIR filter twice
Notice that the unit step response of the filter has less overshoot than that of the
Butterworth filter. The response has a group delay of 37 samples, but the eDAQ
compensates for the delay so that the filtered data displays no phase shift in the stored
data set. Normally decimation occurs after filtering. In this case, every fifth sample is
stored (decimation by five). The exact pattern of the stored data varies depending on
where the decimation occurs relative to the input step edge.
15.2.2 ELLB Digital Filters
Butterworth Eight-Pole Filter
The Butterworth digital filter closely matches the attenuation and step response
characteristics of a conventional analog Butterworth filter. The attenuation and the
step response are shown below.
0 20 40 80
1.0
0.8
0.6
0.4
0.2
0
-0.2
Sample Number
F
i
l
t
e
r

R
e
s
p
o
n
s
e
1.2
10 30 50 60 70
I2740-2.1 en 249
SoMat eDAQ
Figure 15-6: Attenuation of an eight-pole Butterworth filter.
The filter is approximated by a 111-tap FIR filter. The attenuation shows a -3 dB
frequency (break frequency) of 7.5% of the sample frequency and a noise floor of
about 25% of the sample frequency.
Figure 15-7: Unit step response of an eight-pole Butterworth filter.
The unit step response closely resembles that of an analog Butterworth filter.
Linear-Phase Filter
The linear phase filter is designed using the well known Remez algorithm. The ratio of
stop band to pass band frequency is 1.5:1. This filter provides a much sharper
attenuation curve than the corresponding curve for the Butterworth filter.
A
t
t
e
n
u
a
t
i
o
n
Percent of Sample Frequency
Theoretical
FR Approximation
-3 dB
10
1
10
0
10
-1
10
2
10
1
10
0
10
-1
10
-2
10
-3
10
-4
10
-5
10
-6
S
a
m
p
l
e
Sample Number
0 20 40 60 80 100 120 140
0
0.2
0.4
0.6
0.8
1.0
1.2
SoMat eDAQ
250 I2740-2.1 en
Figure 15-8: Attenuation of a 71-tap equiripple, linear-phase FIR filter.
From the attenuation curve, notice that the roll-off frequency is 16.88% of the sample
frequency, the roll-off span is 8.325% of the sample frequency and the noise floor
frequency is 25% of the sample frequency.
Figure 15-9: Unit step response of a 71-tap equiripple, linear-phase FIR filter.
Notice that the unit step response of the filter has less overshoot than that of the
Butterworth filter. The response has a group delay of 35 samples, but the eDAQ
compensates for the delay so that the filtered data displays no phase shift in the stored
data set.
A
t
t
e
n
u
a
t
i
o
n
Percent of Sample Frequency
-3 dB
10
1
10
0
10
-1
10
-2
10
-3
10
-4
10
-5
10
-6
10
1
10
0
10
-1
10
2
S
a
m
p
l
e
Sample Number
0 20 40 60 10 30 50 70 80
1.0
0.8
0.6
0.4
0.2
0
-0.2
1.2
I2740-2.1 en 251
SoMat eDAQ
16 Xth-Percentile Benchmark Tests
The following benchmark tests give an indication of the eDAQ processing limitations
for the special case of using the Xth-percentile mode of the Statistical Analysis
computed channel. The primary reason for this benchmark testing is that sorting large
arrays can become very time consuming as the size of the arrays increase.
All of the tests have the following configuration properties.
An input data signal using a function generator to produce highly unordered
data where nearly every data sample represents a reversal as shown in the plot
below.
Figure 16-1: Plot of the input signal to the eDAQ as sampled by a test bridge channel.
Four bridge channels with 32-bit float output data types.
Twelve Statistical Analysis computed channels using the Xth-percentile mode to
compute the 10%, 50% and 90% percentile values for each of the four bridge
channels.
Two Time History DataModes: one to store the four bridge channels and the
other to store the twelve Xth-percentile mode Statistical Analysis computed
channels.
All data storage in the eDAQ internal flash memory.
After some preliminary testing, the following four tests were performed for final
benchmarking. The only varied parameters were the bridge channel sample rate and
the size of the Statistical Analysis channel analysis window.
SoMat eDAQ
252 I2740-2.1 en
All of the tests were run for several minutes to determine if the eDAQ can handle the
processing load. The first three tests ran with no problems. However, Test 4 reset on
a DeviceOverFlow error shortly after the start of the test run.
Test Bridge Sample Rate Analysis Window Size
Test 1 2000 Hz 20000 samples
Test 2 2000 Hz 50000 samples
Test 3 5000 Hz 20000 samples
Test 4 5000 Hz 50000 samples
I2740-2.1 en 253
SoMat eDAQ
17 Data Processing Algorithms
17.1 Peak Valley Processing Algorithm
There are three states in the peak valley processing algorithm. The algorithm starts in
the initialize state. Thereafter it toggles between the peak search and valley search
states. These states are detailed as follows.
Initialize
The algorithm tracks the maximum and minimum input values until the difference
between the maximum and minimum exceeds the specified hysteresis level. If the
minimum value preceded the maximum value, then the minimum value is the first
valley and the algorithm state switches to peak search. If the maximum value
preceded the minimum value, then the maximum value is the first peak and the
algorithm state switches to valley search.
Peak Search
The algorithm searches for a peak, tracking the maximum and minimum values since
the last stored valley until their difference exceeds the hysteresis level. At this point,
the maximum value is output as the next peak and the algorithm state switches to
valley search.
Valley Search
The algorithm searches for a valley, tracking the maximum and minimum values since
the last stored peak until their difference exceeds the hysteresis level. At this point, the
minimum value is output as the next valley and the algorithm state switches to peak
search.
17.2 Rainflow Cycle Counting Algorithm
Rainflow counted cycles are typically used in low cycle fatigue damage analyses. The
rainflow counting algorithm is based on the one-pass algorithm described in the
paper Simple Rainflow Counting Algorithms, International Journal of Fatigue, January
1982, by D. Socie and S. Downing. The algorithm described in this paper generates
the set of closed cycles for the input peak valley sequence, assuming that the
sequence repeats itself.
However, to support proper rainflow histogram addition (i.e., generating a composite
rainflow histogram from multiple rainflow histograms defined in a specific sequence),
the eDAQ stores both the sequence of unclosed reversals and the histogrammed set
of closed cycles in the Rainflow DataMode.
NOTE
The algorithm requires an allocated memory stack to store the reversals that have not
yet closed. The eDAQ uses a fixed stack size of 1024, which should suffice for the vast
majority of applications. In the rare event that this allocation is insufficient, the eDAQ
aborts the Rainflow DataMode processing and sets an error flag in the output data file.

SoMat eDAQ
254 I2740-2.1 en
I2740-2.1 en 255
SoMat eDAQ
18 Cable Resistances
The following table lists measured resistances for a selection of SoMat cables.
Cable
Length
(m) Order Number
Resistance
(Ohms)
Transducer Cable 2 1-SAC-TRAN-MP-2-2 0.27
10 1-SAC-TRAN-MP-10-2 1.25
Extension Cable 0.4 1-SAC-EXT-MF-0.4-2 0.06
2 1-SAC-EXT-MF-2-2 0.23
5 1-SAC-EXT-MF-5-2 0.61
10 1-SAC-EXT-MF-10-2 1.20
15 1-SAC-EXT-MF-15-2 1.84
SoMat eDAQ
256 I2740-2.1 en
I2740-2.1 en 257
SoMat eDAQ
19 CE Compliance
The following section provides important notes on the CE compliance of the eDAQ
hardware and cables.
19.1 eDAQ Hardware
CAUTION
Do not remove any CE-labeled component or modify a CE-labeled component from
its original condition. Do not disassemble individual layers. HBM cannot ensure the CE
compliance of any hardware that has been modified.

The only recent modification to the eDAQ for CE compliance is on the back panel of
analog-out enabled EHLS and EBRG layers. The Analog Out connector cutout is left
unpainted to ensure solid metal-to-metal contact between the internal and external
connectors.
19.2 Cables
CAUTION
HBM cannot ensure the CE compliance of any cable that has been modified from its
original condition.

The following cables have been recently modified to be CE compliant. All other cables
are also CE compliant.
SAC-EPWR15 Power Cable (1-SAC-EPWR15-2)
SAC-EXT-VBM Vehicle Bus Module Extension Cable (1-SAC-EXT-VBM-2)
SAC-TRAN-AO Analog Out Transducer Cable (1-SAC-TRAN-AO-2)
I
2
7
4
0
-
2
.
1

e
n
S
o
M
a
t

P
/
N

D
O
C

0
0
0
4
-
0
3
HBM, Inc. All rights reserved.
All details describe our products in general form only.
They are not to be understood as express warranty
and do not constitute any liability whatsoever.
measure and predict with confidence
The Americas
HBM, Inc.
19 Bartlett Street
Marlborough, MA 01752, USA
Tel: +1 800-578-4260 Email: [email protected]
Europe, Middle East and Africa
HBM GmbH
Im Tiefen See 45
64293 Darmstadt, Germany
Tel: +49 6151 8030 Email: [email protected]
Asia-Pacific
HBM China
106 Heng Shan Road
Suzhou 215009
Jiangsu, China
Tel: +86 512 682 47776 Email: [email protected]

You might also like