Transcript Summary

The document outlines troubleshooting steps for a scissor lift experiencing software update issues, including symptoms like question marks on the platform module and CANbus failures. It details the likely cause as improper software installation and provides a series of tests and resolutions, such as verifying software part numbers and performing necessary calibrations. Ultimately, the machine was restored to working condition after addressing the identified issues.

Uploaded by

Judah A
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views4 pages

Transcript Summary

The document outlines troubleshooting steps for a scissor lift experiencing software update issues, including symptoms like question marks on the platform module and CANbus failures. It details the likely cause as improper software installation and provides a series of tests and resolutions, such as verifying software part numbers and performing necessary calibrations. Ultimately, the machine was restored to working condition after addressing the identified issues.

Uploaded by

Judah A
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Transcript Summary Results:

Actual Results (Shared Document) Achieved Results (Prompt Builder)

Important Symptoms

1.​ Platform module displaying - Customer attempted a software update


question marks on a scissor lift.
2.​ CANbus failure - Customer is uncertain if the software is
3.​ Power module failure correct for both the base and platform
4.​ Loss of power to the platform modules.
5.​ Machine setup showing incorrect - Customer mentioned potentially
damaging modules during the update
process.
- Customer requires confirmation that the
software part number is appropriate for
their equipment.

Likely Cause

The platform software was installed - The issue is likely caused by incorrect
improperly. software updates on the platform and
base modules.
- There may be a need for proper tilt
calibration following the software update.

Steps To Resolve

●​ The software update process was - Ensure the software update is saved to
reviewed and installed the laptop to avoid module frying due to
●​ The machine setup was toggled internet loss.
between different models and - Verify the correct software part number.
markets to reset configurations. - Perform a tilt calibration if the tilt sensor
●​ Performed calibrations. reading is off.
- Calibrate the elevation sensor.
- Calibrate the 0% load and then the 110%
load.
- Ensure the platform module is visible in
platform mode.
- Verify the platform module software
version.
- Update all modules simultaneously to
prevent CAN bus failures.
- Confirm there is no load cell if the unit
build does not include it.
- Adjust settings to reflect the absence of a
load cell if necessary.

Troubleshooting Steps

1.​ Test: Technician attempted 1. Test - The agent verified the software
to update the software on update on the scissor.
the ES 2632 scissor lift Result – The software was confirmed for
Result: The base module update the base module and platform module.
was successful, but the a. Subsystem – Software
platform module showed b. Device - Scissor
question marks, indicating a
failure. 2. Test - The agent checked the part
●​ Device Tested: Base number for the ES 3226.
Module & Platform Result – There was only one part number.
Module a. Subsystem – Part Number Identification
●​ Subsystem: Software b. Device - ES 3226
Update
2.​ Test: Verified software part 3. Test - The agent examined the tilt
numbers and ensured calibration.
compatibility for both the Result – The tilt was at negative 1.3
base and platform modules. degrees.
Result: Confirmed that the a. Subsystem – Tilt Calibration
correct software version (P1.0) b. Device - Scissor
should be applied to the
platform module. 4. Test - The agent reviewed the platform
●​ Device Tested: module in platform mode.
Platform Module Result – The platform module was P1.0.
●​ Subsystem: Software a. Subsystem – Platform Module Software
Compatibility b. Device - Platform Module
3.​ Test: Re-attempted
platform module update 5. Test - The agent confirmed the load cell
using the system module presence.
reprogrammer. Result – The unit did not have a load cell.
Result: The update process a. Subsystem – Load Cell Module
completed successfully, but the b. Device - Scissor
module still showed question
marks. 6. Test - The agent performed a tilt
●​ Device Tested: calibration after a software update.
Platform Module Result – The tilt calibration was necessary
●​ Subsystem: Software to ensure proper operation.
Deployment a. Subsystem – Tilt Calibration
4.​ Test: Verified if a fuse blew b. Device - Scissor
during the software update
or if power was lost to the
platform.
Result: No immediate power
failure was identified.
●​ Device Tested:
Platform Power
Circuit
●​ Subsystem: Power
5.​ Test: Accessed machine
setup settings and toggled
the model and market
region to reset
configurations.
Result: Allowed reconfiguration
of software settings, but the
platform module still displayed
question marks.
●​ Device Tested:
Machine Setup
●​ Subsystem:
Configuration
Settings
6.​ Test: Checked voltage at the
contactor using a
multimeter.
Result: Detected low voltage
(6.0V instead of expected
value), indicating a potential
issue.
●​ Device Tested:
Power Module &
Contactor
●​ Subsystem:
Contactor Circuit
7.​ Test: Verified voltage at the
power module to determine
if the contactor was
functioning properly.
Result: Voltage was present but
lower than expected, possibly
causing a power module failure.
●​ Device Tested:
Ground & Power
Module
●​ Subsystem: Electrical
8.​ Test: Verified and changed
motor type in machine
setup from AC to DC to
troubleshoot power issues.
Result: Switching to DC drive
allowed the machine to
function properly.
●​ Device Tested: Drive
Motor
●​ Subsystem: Drive
System
9.​ Test: Rechecked software
version with the key switch
in platform mode.
Result: Platform module
software version P1.0 was
confirmed.
●​ Device Tested:
Platform Module
Software
●​ Subsystem: Platform
Mode & Software
Confirmation
10.​Test: Identified the need to
calibrate the load system at
0% and 110% capacity using
weight.
Result: Required additional
weight (batteries or test
weights) to complete
calibration.
●​ Device Tested: Load
Cell System
●​ Subsystem: Load
Calibration
11.​Test: Verified tilt reading
and recalibrated the tilt
sensor due to a negative
1.3-degree reading.
Result: Ensured accurate tilt
calibration for proper machine
operation.
●​ Device Tested: Tilt
Sensor
●​ Subsystem: Tilt
Sensor Calibration
12.​Test: Cycled e-stop, verified
drive function, and
rechecked software
versions.
Result: Machine was
successfully restored to
working condition.
●​ Device Tested: Full
System Functionality
●​ Final Steps: System
Reset & Verification