Using USB TO RS232 cable to connect PC’s USB to the Laser’s RS-232 connector.
Check the port number after connecting cable:my computer - > properties - > hardware
- > device manager - >
将串口号选为上图的串口号,然后点击打开串口,如下
2) Connecting state
1
Figure 2 GUI disconnected state
Note: All the parameters except power can’t be modified during emission.
3 Control MO signal
E type software can modify laser default parameter setting and selection in the option of
"Parameter setting" and “Parameter selection”. The parameter settings take effect immediately
and save automatically after power down.
Default pulse: The laser will use GUI default pulse when no pulse width control command
received.
Simmer:Can be used for controlling the height of the first pulse, the higher the value, the larger
the first pulse. Setting range: 0-1000
[Appropriate Simmer]
[High Simmer]
[Low Simmer]
Red Power: Brightness of built-in red pilot(optional) can be adjusted, value range is 0-100.
External frequency: When selecting external frequency mode, the laser output pulse will be
synchronized with external frequency signal. When not selecting this option, the laser will use
with internal frequency mode. And the laser will calculate external frequency signal in MO and
PA delay time. Default setting is internal frequency mode.
[External Frequency]
[Internal Frequency]
*T=Duration of pulse period, maximum duration ≤ cut off frequency period
Pin9Lock:Power latch function is enabled if selected, rising edge is effective. Default setting is
not selected.
Pin23Stop:Emergency stop function is enabled if selected, low level is effective. Default setting
is not selected
Fan Speed Control:The laser fan speed will be control according to the value of the built-in
temperature sensor. If not selected, the fans will run at full speed. Default setting is selected.
Note:The parameter setting of E type software takes effect immediately, no need to restart laser.
StrengMc:Checking "Enhanced Mode" will increase the average power of the laser by 20%
while keeping the cut-off frequency unchanged. At this time, it is recommended that the
operating environment temperature range is 5~35℃. The laser may trigger a sensor alarm. Please
refer to Table 1 for the recommended operating temperature range of the laser in different modes.
This mode is not checked by default.
The laser running status and alarm record can be read by E type software.
1) Status monitoring
Pump indicator light: Monitor whether the pump of the laser is currently in normal working
state, which is green under normal conditions, and red light if abnormal alarm occurs.
PA、MO、Red indicator light: Monitor the control signal. Green light means signal is effective
(high level), and red light means signal is not effective (low level).
D0-D7 indicator light:Monitor the current power signal of the laser, corresponding the 8-bit
binary mode, D0 is the lowest and D7 is the highest. Green light means this pin signal is
effective (high level), and red light means this pin signal is not effective (low level).
PRR/kHz and PULSE/ns: Monitor the actual laser working frequency and pulse width.
Power current: Monitor the post amplifier driving current value of the laser.
System parameter: Internal system parameter setting interface (For JPT internal use only).
2) Alarm description
No pulseE: No seed source backlight signal detected or backlight signal frequency less than
1kHz.