Fresh Air Cube
Fresh Air Cube
AIRCUBE
PURIFIES UP TO 1,500 SQUARE FEET
________________________________________ ________________________________________
Vollara Independent Business Owner Name Phone Number
2
INTRODUCTION
front grill
power in
3
PLACEMENT
CAUTION: Do not operate the FreshAir Cube near heat source, open flames,
or combustible vapors or gases.
4
POWER SUPPLY
SPECIFICATIONS
Electrical: Size:
• 100 - 240VAC • Dimensions: 85203-CHN-001
5
CONTROL PAD AND LED LIGHTS
on/off power
The control pad is
conveniently located
fan speed + on the right side of
your FreshAir Cube
fan speed -
green & red LED
away mode
Red LED solid = Away Mode (returns to Normal Mode after 2 hours or user input is
detected, whichever comes first)
Green LED solid = scalable ozone setting
6
CONTROL PAD INFORMATION
Push the “AWAY MODE” button a second time and the unit goes into the scalable ozone mode.
When the unit is in the scalable ozone mode, the indicator light will be illuminated green.
In the scalable ozone mode, the FreshAir Cube unit will operate in a 20%-on, 80%-off mode, over
a one minute total cycle time. This means the unit will continuously cycle the ozone plate on, at
maximum output, for 12 seconds and then transition to ozone plate off for 48 seconds ... then repeat.
Push the button again, and the unit will revert to the “Normal” operation mode (ActivePure only).
CAUTION: Away Mode is intended for unoccupied spaces only. Please be sure all
people and pets have vacated the area when Away Mode is in use.
7
REMOTE CONTROL
The FreshAir Cube remote control gives you the convenience of control from anywhere in the
room. Before use, remove paper tab from the bottom of the remote. When replacing battery,
choose a 3 Volt lithium cell CR2025.
8
PARTS
Replacement parts
power cord
9950099
If your unit fails to operate properly or you have questions, contact your Vollara
Independent Business Owner for further assistance.
9
MAINTENANCE
Upkeep
Periodically vacuum or wipe the front grill with
a soft towel. You can vacuum or wash the rear
filter in warm water and let dry completely before
reinstalling (replace if necessary). Wipe down the
outside with a damp (not wet) cloth. Reassemble
when finished.
CAUTION: Always unplug the power cord from the back of your FreshAir Cube
before servicing. Removing cover may expose ultraviolet light source. To
protect against eye damage, always unplug before servicing.
REPAIR AND UPKEEP
Unplug unit. (1) Remove the back panel screws and (2) back panel. (3) Press latches and (4)
unplug the power connector to the ActivePure® (RCI) Cell.
(5) Pull the ActivePure Cell straight out to remove. Reverse order to replace cell.
CAUTION: Always unplug the power cord from the back of your FreshAir Cube
before servicing. Removing cover may expose ultraviolet light source. To
protect against eye damage, always unplug before servicing.
REPAIR AND UPKEEP
3
2
Unplug unit. (1) Remove the back panel screws and (2) back panel.
(3) Press latches and (4) unplug the power connector to the purifier plate.
(5) Remove the purifier plate from its slot. Reverse order to replace purifier plate.
CAUTION: Always unplug the power cord from the back of your FreshAir Cube
before servicing. Removing cover may expose ultraviolet light source. To
protect against eye damage, always unplug before servicing.
REPAIR AND UPKEEP
2 3
1
4
Unplug unit. (1) Remove the back panel screws and (2) back panel. (3 - 5) Remove the purifier
plate from its slot. (6) Clean purifier plate by wiping with a cotton swab dipped in denatured
alcohol. Allow purifier plate to dry completely before reinstalling.
CAUTION: Always unplug the power cord from the back of your FreshAir Cube
before servicing. Removing cover may expose ultraviolet light source. To
protect against eye damage, always unplug before servicing.
DEEP CLEANING
1 2
3 4
Unplug unit. (1) Remove back cover. (2) Remove ActivePure Cell (see page 11).
(3) Remove purifier plate (see page 12). (4) Remove the four front grill screws and the front
grill. You can now access the inside of the unit and the fan for cleaning.
CAUTION: Always unplug the power cord from the back of your FreshAir Cube
before servicing. Removing cover may expose ultraviolet light source. To
protect against eye damage, always unplug before servicing.
LIMITED ONE (1) YEAR WARRANTY
Customer should not repackage and ship the FreshAir Cube unit due to possibility of irreparable damage.
For warranty service, please contact your Independent Distributor or Vollara Customer Service for the address of the
nearest service center.
LIMITED ONE (1) YEAR WARRANTY MISSING SERIAL NUMBERS & UNAUTHORIZED CHANNELS
Customer should not repackage and ship the FreshAir Cube unit due to If a valid serial number is missing from the product, the warranty will
possibility of irreparable damage. For warranty service, please contact be voided. Vollara products are authorized for sale through Vollara
Vollara Customer Service at 800.989.2299, or your Vollara Independent Independent Distributors only. Warranties are voided if a product is
Distributor, for the address of the nearest service center. purchased through unauthorized channels. This includes websites that
are not authorized to use Vollara’s trademarked names, images and
WHAT IS COVERED BY THIS WARRANTY logos as well as Internet auction sites (e.g. ebay and Craigslist). The only
We warrant the FreshAir Cube to the Customer, subject to the approved Internet presence for Vollara products is www.vollara.com.
conditions below, against defects in workmanship or material, provided To confirm warranty coverage prior to purchasing a product, contact
that the products are returned to a service location within one (1) year Vollara at 800.989.299 with the serial number located on the back of
from the date of purchase. the unit.
INSTALLATION AND MAINTENANCE REQUIREMENTS EXCLUSION OF OTHER WARRANTIES & CONDITIONS
This warranty is expressly conditioned upon proper installation, EXCEPT AS PROVIDED HEREIN, WE MAKE NO REPRESENTATION OR
operation, cleaning and maintenance, all in accordance with the WARRANTY OF ANY KIND. ALL OTHER WARRANTIES OF ANY KIND,
User’s Manual. Failure to meet any of these requirements will void this EXPRESS OR IMPLIED, ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING
warranty. Servicing of your FreshAir Cube by parties other than our ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
authorized service center and/or using parts other than genuine parts PARTICULAR PURPOSE.
will also void this warranty. LIMITATION OF LIABILITY FOR SPECIAL, INCIDENTAL, OR
HOW TO OBTAIN WARRANTY SERVICE CONSEQUENTIAL DAMAGES
Customer must contact Vollara Customer Service and provide proof of WE SHALL NOT IN ANY CASE BE LIABLE FOR SPECIAL, INCIDENTAL
purchase within the above time period. We will repair or replace and OR CONSEQUENTIAL DAMAGES ARISING FROM BREACH OF
return the product, without charge and within a reasonable period of EXPRESSED OR IMPLIED WARRANTIES, CONDITIONS, GUARANTEES
time, subject to the conditions herein, if its examination shall disclose OR REPRESENTATIONS, BREACH OF CONTRACT, NEGLIGENCE OR ANY
any part to be defective in workmanship or material. If we, in our OTHER LEGAL THEORY. Such excluded damages include, but are not
limited to, loss of profits or revenue, and loss of the use of the products,
discretion, are unable to repair the product after a reasonable number
and any loss caused by leaks or other water damage. This warranty is
of attempts, we will provide either a refund of the purchase price or a
provided by:
replacement unit, at the company’s option.
Vollara, LLC
WHAT IS NOT COVERED BY THIS WARRANTY 300 East Valley Drive
This product is intended for household use only. Ordinary wear and Bristol, VA 24201.
tear shall not be considered a defect in workmanship or material. SERVICE
These warranties do not apply to filters nor for loss or damage caused Every effort is made to ensure customers receive an up-to-date
by accident, fire, abuse, misuse, improper installation, leaking, instructions manual on the use of our products; however, from time
modification, misapplication, commercial use or by any repairs other to time, modifications to our products may without notice make the
than those provided by our authorized Service Center. This warranty is information contained herein subject to alteration. For the latest
non-transferable. information, please visit our website.
FCC DECLARATION OF CONFORMITY
Name: Vollara, LLC This equipment has been tested and found to
comply with the limits for Industrial, Scientific,
Model: FreshAir Cube
and Medical Equipment (ISM), pursuant to
This device complies with Part 18 of the FCC Rules. These limits are
Part 18 of the FCC Rules. designed to provide reasonable protection
RESPONSIBLE PARTY against harmful interference in a residential
installation. This equipment generates, uses,
and can radiate radio frequency energy, and if
Signature:________________________ not installed and used in accordance with the
Printed Name: Andy Eide instructions, may cause harmful interference
Title: Vice President, Product to radio communications. However, there is
Development & Manufacturing no guarantee that interference will not occur
Date: 10/15/2018 in a particular installation. If this equipment
does cause harmful interference to radio
or television, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures: Reorient
Vollara, LLC or relocate the receiving antenna. Increase
300 East Valley Drive the separation between the equipment and
Bristol, VA 24201
receiver. Connect the equipment into an outlet
on a circuit different from that to which the
receiver is connected.
65-00733 VA-01268
Consult the Distributor or an experienced radio/
© 2018 Vollara, LLC. All Rights Reserved.
FAC_OM_65-00733_VA-01268_1018 TV technician for help.
16