0% found this document useful (0 votes)
56 views4 pages

Highly Rotary R290 Compressors

The document lists various models of rotary compressors designed for R290 refrigerant, detailing specifications such as displacement, heating capacity, COP, and testing conditions. It includes single and twin cylinder models with varying capacities and dimensions. The compressors are tested under ASHRAE/T conditions and range from 2130 W to 21830 W in heating capacity.

Uploaded by

h2oo2h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views4 pages

Highly Rotary R290 Compressors

The document lists various models of rotary compressors designed for R290 refrigerant, detailing specifications such as displacement, heating capacity, COP, and testing conditions. It includes single and twin cylinder models with varying capacities and dimensions. The compressors are tested under ASHRAE/T conditions and range from 2130 W to 21830 W in heating capacity.

Uploaded by

h2oo2h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Rotary Compressors for R290

HIGHLY R290 INVERTER COMPRESSOR


Heating Heating Rated
Compressor Compressor Model Displacement COP Testing Height
Cylinder Capacity Capacity Speed
Series (R290)* (cc/rev) (heating) Condition (mm)
(W) (Btu/h) (RPM)
SD WHP02000PCKQF3BU6B Single cylinder 8,8 2130 7268 4,73 3600 ASHRAE/T 247
SD WHP03300PRKQA6JT6 Single cylinder 14,0 3389 11563 4,78 3600 ASHRAE/T 253,5
TD WHP03600PRKQA7JT6 Twin cylinder 15,0 3570 12181 4,35 3600 ASHRAE/T 308,7
TD WHP05500PUKPA6NT6 Twin cylinder 22,6 5355 18271 4,66 3600 ASHRAE/T 338,7
TH WHP07600PSDPC9KQ Twin cylinder 30,7 7475 25505 4,73 3600 ASHRAE/T 353,6
TH WHP10200PSDPC9KQ Twin cylinder 41,8 10180 34734 4,66 3600 ASHRAE/T 353,6
TH WHP13300PSDPC8FQ Twin cylinder 54,8 13320 45448 4,65 3600 ASHRAE/T 383,5
TE WHP18600PSKTQ9JK Twin cylinder 75,2 19045 64982 4,55 3600 ASHRAE/T 512,0
TE WHP37600PSKTQ9JK Twin cylinder 84,8 21830 74484 4,55 3600 ASHRAE/T 512,0
Range of operation
Range of operation
Range of operation:
WHP02000PCKQF3BU6B