INTELLIGENT ADDRESSABLE
FIRE ALARM CONTROL PANEL Model : AS-801-FAP (1-10 Loop)
Description
ASES Intelligent Addressable AS-801-FAP is an advance fire
detection panel which can detect fires & Smoke through
wired, detectors & Devices. With an intuitive touchscreen
interface, it can provide information/address of every detector
& devices and be Configured in a simple and intuitive way.
Features
ASES Intelligent Addressable fire alarm control panels are
specially design & developed on ASES FIRENET protocol. It is a
range of compact & feature rich, modern-age panel that are
design keep in mind the need of customers. Panel is designed to
keep its functions & programming simple & user friendly.
Panels are fully expandable from 1-10 loops and supplied with 7”
inch touch screen. Each loop is capable of supporting 250
Nos. of detectors/devices in any combinations basic, model
comes without loop card can connect 10 nos. of single loop
cards. The control panel can be programmed locally through 7”
touch screen. No external DONGLE or special cable required for
panel programming. For authentication multilevel password is
provided. These password can be changed as per user
requirements.
The robust panel is backed by a powerful SMPS Power supply
with all kind of protections high voltage, short circuit, reverse
battery, low battery, earth fault, voltage fluctuation. Power
supply is designed with inbuilt battery charger that can charge
battery up to 2x12V 17Ah battery.
For complex/Bigger applications, it can be installed in a
NTWKP2P-V1.0.0 network through canvas networking (up to 64
control panels) where zones and areas controlled by detection
devices can be managed via sophisticated programmable
logics to trigger events on the central unit. (Data log in capacity A simple and ergonomic touch human machine interface allows
is 11000 events). any type of user an intuitive interaction without time or training
Installing additional boards, it is also possible to add peripheral costs. All configuration steps are immediate and the self-
devices to the main panel like keyboards, printers, LED panels. programming and self addressing mechanisms allows to
Connected detectors and devices are monitored and recognize, interrogate and program devices in the field quickly,
diagnosed via the control panel. All the test procedures can be systematically and without errors.
performed via ASES AS- 801 FAP to assess the status of each The control panel can be customized for all installation
component simplifying and speeding up periodic maintenance conditions: mechanics colour, display background, colour of the
process. Nonetheless, diagnostic data and historical data programmable LEDs, logo displayed on the welcome screen and
recorded can be easily exported in Excel format. language can be chosen as desired.
Custom Colours
Certifications
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010
ASES As per IS : 2189
www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]
ASES AS-801 FAP can be programmed both on site and remotely, using the dedicated SMS, GPRS, Ethernet, WiFi, Cloud Reporting
online platform, data can be exported and imported via USB stick. Monitoring takes place thanks to the NTWKP2P-V1.0.0 supervision
system.
The device is certified by NABL accredited labs ERTL for fire detection and signalling systems. It offers One levels of access depending
on the operator (installer, safety manager, end user).
Applications
One can fit small and large installations. It can find application in the following fields:
ª Industrial plants, offices, shops and buildings that host communities.
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010 www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]
Don’t Just Read - TOUCH! Maintenance Is Now Easy
Today, interacting with TOUCH is part of everything around us Effective maintenance, is in fact, the most important function of
and everything we do. Fire Alarm Control Panels should not be after sales service that ASES strives to provide to its clients. Now
any different. AS-801-FAP is not just a user interface; it is the devices appear in a display, colourful presentation rather than
graphical representation of commands, functions, and written format. Green means Detectors is identified, Yellow
important information on the Fire Alarm Control Panel. All the means output device is identified, and finally Violet means Input
commands, information, devices, zones, are presented using Device is identified. While the ASES detectors are already
simple graphical pictures, which increases the ease of use. equipped with drift compensation and patented double dust
Additional peace of mind comes through the panel’s One levels trap; easy to identify maintenance support is the key feature of
of user passwords. These ensure that only qualified people can AS-801-FAP. In addition, all the other main functions such as
access to the right information they need. disabled devices will appear in the much easier to understand
graphical presentation. Finally, over 11,000 events storage, will
make the panel ready to accommodate a lengthy history of
events for the user to scroll between.
Easy To Program
ASES AS-801-FAP addresses all the devices electronically.
Dipswitches, or ASES Programmer. This feature not only makes
the programming faster and easier, it also can provide a safe-
addressing topology to the devices on the loop. All sounder
tones, flasher speeds, automatic commissioning test, unlimited
time delays, alarm duration, pre-alarm commissioning, double
knock events, special event linked programs, to name few of this
powerful commissioning capability.
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010 www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]
Electrical Data
Power Supply 200-240V AC 50/60Hz
Stand by Current Consumption 5L/10L 350 mA/750mA @ 24Vdc (Panel) 50mA @ 24Vdc (Loop card)
Battery Charger Range 7 Ah-50Ah (use separate cabinet for batteries over 15 Ah)
Max Current available for the Loop [mA] 500 mA per Loop card
General Fault report relay 230ac@7A V dc@7A Buzze 2 PFC Relay (1 Fire + 1 Fault)
Communication Protocol USB Port for Panel Configuration RS 485/ Proprietary for
Repeater panel & networking
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010 www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]
Accessories Expansions
Mechanical Description
25 mm 25 mm 25 mm 25 mm 25 mm 25 mm
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010 www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]
Loop Wiring Installation
Limited Warranty
ASES warranty that the product will be free of charge for repairing or replacing from defects in design, materials and workmanship
during the warranty period. This warranty does not cover any product that is found to have been improperly installed or used in any way
not in accordance with the instructions supplied with the product. Anybody, including the agents, distributors or employees, is not in the
position to amend the contents of this warranty. Please contact your local distributor for products not covered by this warranty.
AHU
Off. & Works : ASES HOUSE, A-2/69, Site-IV, Sahibabad Industrial Area, Ghaziabad, U.P.-201010 www.asesindia.com R-09-2024
Telephone : 0120-4152341 Email : [email protected]