REFLECTED20CEILING20PLAN

The document is a reflected ceiling plan for a proposed one-storey, four-bedroom residence designed by Jericho C. Manarang. It includes details about various lighting fixtures, their quantities, and specifications, along with the architect's contact information. The plan is intended for approval by the clients, Mr. and Mrs. Aaron N. D. Soto.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views1 page

REFLECTED20CEILING20PLAN

The document is a reflected ceiling plan for a proposed one-storey, four-bedroom residence designed by Jericho C. Manarang. It includes details about various lighting fixtures, their quantities, and specifications, along with the architect's contact information. The plan is intended for approval by the clients, Mr. and Mrs. Aaron N. D. Soto.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

LEGENDS:

11.00M
5.60M 4.90M D E S C R I P T I O N S U P P L I ER
3.40M
Q T Y .
0 . 6 0 M M D I A . H O M E
5 PCS TRIPLE LED CEILING LIGHT D E P O T

0 . 5 0 M M x 0 . 5 0 M M H O M E
11 PCS. D O U B L E L E D C E I L I N G L I G H T D E P O T

2.90M

2.90M
0.20M DROPPED FROM
CEILING LINE
H O M E
0.20M DROPPED FROM 6 P C S . 62" LINE OUTPUT FLUORESCENT D E P O T
CEILING LINE
H O M E
52 PCS. 0 . 2 0 M M D I A . C O V E L I G H T S D E P O T

1.50M
0.10M FLAT
H O M E
CEILING LINE 0.10M FLAT 5 PCS P E N D A N T L I G H T D E P O T

2.90M
CEILING LINE

H O M E
0.20M DROPPED FROM 5 P C S 0.25 MM DIA. GENERIC LIGHT BULB D E P O T
CEILING LINE
H O M E
3 PCS. L I N E A R L E D L I G H T S

2.90M
D E P O T

1.50M
0.20M DROPPED FROM
0.10M FLAT CEILING LINE
CEILING LINE

1.50M
0.10M FLAT
CEILING LINE

3.25M
0.10M FLAT 0.10M FLAT
CEILING LINE CEILING LINE

3.80M
0.20M DROPPED FROM 0.20M DROPPED FROM
CEILING LINE CEILING LINE

25.00M

25.00M
3.10M
1.80M
0.10M FLAT
0.20M DROPPED FROM
CEILING LINE
CEILING LINE

0.10M FLAT
CEILING LINE

8.40M
2.90M
0.10M FLAT
CEILING LINE

0.20M DROPPED FROM


CEILING LINE

6.00M

0.20M DROPPED FROM


CEILING LINE 0.20M DROPPED FROM
CEILING LINE

2.50M
6.00M 4.85M

11.00M

REFLECTED CEILING PLAN


SCALE: 1:125 MTS

LOGO MANARANG, J.C. ARCHITECTURAL FIRM


PESCADORES,CANDABA, PAMPANGA GRADE : PROJECT NAME : CLIENT/OWNER : CLIENT/OWNER SIGNATURE : SHEET TITLE/CONTENT : REVISION NO. : SHEET NO. :
0970-931-0055/ [email protected]
PROPOSED ONE (1) STOREY
JERICHO C. MANARANG 4-BEDROOOM RESIDENCE
APPROVED AND SIGNED BY
NAME OF STUDENT
LOCATION: MR. & MRS. AARON N. D. SOTO (SIGNATURE OVER PRINTED NAME) REFLECTED CEILING PLAN SCALE 1:125
COURSE : BACHELOR OF SCIENCE IN ARCHITECTURE
SECTION : 3-H
INSTRUCTOR : AR. AARON NONNATUS D. SOTO
BRGY. STA. CRUZ, MEXICO, PAMPANGA DATE:
DATE :