0% found this document useful (0 votes)
12 views4 pages

Patch Ecuj

The document outlines detailed solutions for emissions control systems, including DPF, EGR, and SCR components, with specific patterns, offsets, and methods for adjustments. It provides instructions for disabling or simulating various sensor readings and control mechanisms to optimize performance after removal of emissions systems. Additionally, it includes verification steps to ensure proper operation and compliance with emissions standards.

Uploaded by

immoking
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views4 pages

Patch Ecuj

The document outlines detailed solutions for emissions control systems, including DPF, EGR, and SCR components, with specific patterns, offsets, and methods for adjustments. It provides instructions for disabling or simulating various sensor readings and control mechanisms to optimize performance after removal of emissions systems. Additionally, it includes verification steps to ensure proper operation and compliance with emissions standards.

Uploaded by

immoking
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 4

// Detailed_Emissions_Solutions.

json
{
"metadata": {
"timestamp": "2025-04-19 10:04:00",
"author": "ecumaster1",
"version": "4.0.0"
},
"DPF_complete_solution": {
"identification": {
"pressure_sensor_maps": {
"primary": {
"pattern": "44 50 46 5F 50 52 53 5F 31",
"offset": "0x25000",
"size": "32 bytes",
"solution": {
"method": "Zero values",
"write": "00 00 00 00 00 00 00 00",
"verification": "Check all bytes zeroed"
}
},
"secondary": {
"pattern": "44 50 46 5F 50 52 53 5F 32",
"offset": "0x25100",
"solution": {
"method": "Fixed value simulation",
"value": "0.1 bar differential"
}
}
},
"temperature_sensors": {
"pre_dpf": {
"pattern": "44 50 46 5F 54 31",
"offset": "0x25200",
"solution": {
"method": "Fixed temperature",
"value": "300°C normal operation",
"write_value": "FF FF FF FF"
}
},
"post_dpf": {
"pattern": "44 50 46 5F 54 32",
"offset": "0x25300",
"solution": {
"method": "Fixed temperature",
"value": "280°C normal operation"
}
}
},
"regeneration_control": {
"main_trigger": {
"pattern": "44 50 46 5F 52 47 4E 5F 54 52 47",
"offset": "0x26000",
"solution": {
"method": "Disable completely",
"write": "00 00 00 00"
}
},
"post_injection": {
"pattern": "50 53 54 5F 49 4E 4A",
"offset": "0x26100",
"solution": {
"method": "Remove post injection",
"maps": [
"Quantity map",
"Timing map",
"Enable conditions"
]
}
},
"soot_mass": {
"pattern": "53 4F 4F 54 5F 4D 41 53",
"offset": "0x26200",
"solution": {
"method": "Fixed low value",
"value": "2g permanent"
}
}
}
}
},
"EGR_complete_solution": {
"valve_control": {
"primary_control": {
"pattern": "45 47 52 5F 43 54 4C 5F 31",
"offset": "0x27000",
"solution": {
"method": "Force closed position",
"write": "00 00",
"verification": "Position sensor reads closed"
}
},
"flow_maps": {
"main_map": {
"pattern": "45 47 52 5F 46 4C 57 5F 4D",
"offset": "0x27100",
"size": "16x16",
"solution": {
"method": "Zero flow matrix",
"additional": "Optimize timing maps"
}
},
"cold_start": {
"pattern": "45 47 52 5F 43 4C 44",
"offset": "0x27200",
"solution": {
"method": "Disable cold start EGR",
"compensation": "Adjust fuel quantity"
}
}
},
"temperature_control": {
"pattern": "45 47 52 5F 54 45 4D 50",
"offset": "0x27300",
"solution": {
"method": "Fixed normal temperature",
"value": "90°C simulation"
}
}
}
},
"SCR_complete_solution": {
"nox_sensors": {
"upstream": {
"pattern": "4E 4F 58 5F 55 50",
"offset": "0x28000",
"solution": {
"method": "Fixed values simulation",
"idle": "200ppm",
"cruise": "150ppm",
"full_load": "300ppm"
}
},
"downstream": {
"pattern": "4E 4F 58 5F 44 4F 57 4E",
"offset": "0x28100",
"solution": {
"method": "Fixed ratio calculation",
"value": "80% reduction simulation"
}
}
},
"urea_injection": {
"dosing_control": {
"pattern": "55 52 45 41 5F 44 4F 53",
"offset": "0x28200",
"solution": {
"method": "Disable injection",
"maps": [
"Base dosing",
"Temperature correction",
"Load correction"
]
}
},
"level_sensor": {
"pattern": "55 52 45 41 5F 4C 56 4C",
"offset": "0x28300",
"solution": {
"method": "Fixed level simulation",
"value": "75% permanent"
}
}
}
},
"optimization_after_removal": {
"fuel_maps": {
"main_quantity": {
"pattern": "46 55 45 4C 5F 4D 41 49 4E",
"offset": "0x29000",
"adjustments": {
"low_load": "Optimize without EGR influence",
"high_load": "Remove DPF restrictions"
}
},
"injection_timing": {
"pattern": "49 4E 4A 5F 54 49 4D",
"offset": "0x29100",
"adjustments": {
"advance": "1-2° throughout map",
"reason": "Better combustion without EGR"
}
}
},
"boost_control": {
"target_map": {
"pattern": "42 53 54 5F 54 47 54",
"offset": "0x29200",
"adjustments": {
"low_end": "Increase 0.2bar",
"mid_range": "Optimize for no back pressure",
"high_end": "Remove DPF limitations"
}
}
}
},
"verification_steps": {
"initial_checks": [
"No pressure differential",
"Normal temperature readings",
"No regeneration requests",
"EGR valve closed",
"No SCR dosing"
],
"running_checks": {
"cold_start": "Check smooth operation",
"idle": "Verify stable",
"acceleration": "Monitor smoke",
"cruise": "Check fuel economy",
"full_load": "Monitor EGTs"
},
"diagnostic_verification": {
"no_dtc_set": [
"P2002 - DPF",
"P0401 - EGR",
"P20EE - SCR"
],
"sensors_reading": "All within normal ranges"
}
}
}

You might also like