SNMP Web Manager User Manual
SNMP Web Manager User Manual
Manager
User’s Manual
Table of Contents
1. Introduction ................................................................................................................. 2
2. SNMP Web Manager Install, Quick Start and Uninstall ..................... 2
2.1. Software Installation .......................................................................................................... 3
2.2. Software Quick Start ........................................................................................................... 6
2.3. Software Uninstall ................................................................................................................ 7
3. SNMP Web Manager GUI ...................................................................................... 7
3.1. SNMP Device List ................................................................................................................... 8
3.2. Scan ............................................................................................................................................... 8
3.3. Add IP Address ....................................................................................................................... 8
3.4. Delete IP Address.................................................................................................................. 8
3.5. Open web server page ........................................................................................................ 9
3.6. SNMP Status ........................................................................................................................... 10
3.7. Reset ........................................................................................................................................... 10
3.8. Use system time ................................................................................................................... 13
4. SNMP Web Manager Function Menu ............................................................ 13
4.2. System ....................................................................................................................................... 13
4.2.1. Login ................................................................................................................................... 13
4.2.2. Logout................................................................................................................................ 14
4.2.3. Quit...................................................................................................................................... 14
4.3. Settings ..................................................................................................................................... 14
4.3.1. Basic Info ........................................................................................................................ 14
4.3.2. IP Setting ........................................................................................................................ 15
4.3.3. Online upgrade ............................................................................................................. 17
4.3.4. System manager ......................................................................................................... 20
4.3.5. Static trap address..................................................................................................... 21
4.3.6. SMS Configuration ...................................................................................................... 21
4.4. Language .................................................................................................................................. 24
4.5. Help .............................................................................................................................................. 24
1
1. Introduction
SNMP Web Manager is a configuration wizard to configure SNMP web card in computer
OS with windows, linux or MAC. For the detailed supported operation systems, please
check next chapter. Users can search and configure all SNMP devices in the LAN via
SNMP interface.
Supported OS:
Windows 2000
Linux RedHat 8, 9
Linux Fedora 5
2
2.1. Software Installation
Step 1: Click install file, it will display the installation in process. Refer to the
diagram 2-1.
Diagram 2-1
Diagram 2-2
3
Diagram 2-3
Step 4: Click “Choose” button to change the default folder. After choosing the
installed folder, click “Next” button. Refer to the following diagram 2-4.
Diagram 2-4
4
Step 5: Choose the shortcut folder and click “Next” button. Refer to the following
diagram 2-5.
Diagram 2-5
Step 6: It will display the software summary before installation. Click “Install”
Diagram 2-6
5
Step 7: Click “Done” button to confirm the installation completely.
Diagram 2-7
Note: Please uninstall the previous version before install the new version software.
Or, use the Start Menu method; Start >> All Programs >> SNMP Web Manager >>
Shortcut icon
6
2.3. Software Uninstall
Note: Before uninstall software, you must stop all software programs first and then log
Please choose Start >> All Programs >> SNMP Web Manager >> Uninstall. Then follow
Diagram 3-1
A. Function menu offers complete tool-set for navigating and setting the GUI.
B. SNMP device list can list down all SNMP devices located in current IP address.
7
3.1. SNMP Device List
The default value in window list would be current PC IP address. For example, if IP address
3.2. Scan
You may enter specific IP address and then click “Scan” button to search.
Click “Add” button and it will pop up a window to ask for entering specific IP address. Then,
Diagram 3-2
Select unnecessary IP address from list and click “Del” button to delete from list.
8
3.5. Open web server page
Double click device list to open web server page. Refer to Diagram 3-3.
Diagram 3-3
You will see the SNMP web server page, Refer to Diagram 3-4.
Diagram 3-4
9
3.6. SNMP Status
After one IP address is selected from the IP list, SNMP status will become 0 or 1. If SNMP
card has program inside, SNMP status becomes 1. If it has not program inside, SNMP status
becomes 0. If none of any IP address is selected, SNMP status will display “---“ as default.
Diagram 3-5
3.7. Reset
If it is requested to restart the IP address of device, please select "SNMP reset enable" and
click on the "Reset" button. After confirming the login, you can restart the device. Steps are
as follows:
Step1: Select IP address needed to restart from IP list. Refer to Diagram 3-6.
10
Diagram 3-6
Step2: Click checkbox of "SNMP reset enable". Then, "Reset" button will become available
Diagram 3-7
11
Step3: Click "Reset" button and it will prompt dialog to confirm this operation. Refer to
Diagram 3-8.
Diagram 3-8
Step4: Click "Yes" button and it will pop up a dialog to ask login. If "No" is selected, this
Diagram 3-9
12
Step5: Enter password and then click "Login" button. The target device will be restarted.
NOTE: If changing MAC address of current device before reboot and current device is
If you select use system time, SNMP card will use PC system time. Refer to Diagram 3-10.
Diagram 3-10
4.2. System
4.2.1. Login
When remotely login to access SNMP devices, it’s necessary to verify ID. The default
password is “12345678”.
13
Step2: Enter default password and then click “Login” button. Or click “Cancel” to cancel
login. Refer to Diagram 4-1.
Diagram 4-1
4.2.2. Logout
4.2.3. Quit
Select “Quick” to exit SNMP Web Manager.
4.3. Settings
Basic information displays IP address and Mac address. Refer to Diagram 4-2。
14
Diagram 4-2
4.3.2. IP Setting
Step : Select IP address from IP list. It will display MAC address of device in the
Diagram 4-3
15
Part 2: There are two methods to obtain IP address:
The system will default automatically obtain IP addresses. If there is no this kind of service
Diagram 4-4
Enter the DNS and then click “Apply” button. Refer to Diagram 4-5.
16
Diagram 4-5
Upgrade the selected devices: It will upgrade all SNMP devices listed on the window.
Upgrade all un-upgraded devices: It will only upgrade SNMP devices which are not
Force to upgrade all devices: No matter what kinds of version are used for SNMP
devices listed in the window list, it will upgrade all devices to the latest version used
17
Diagram 4-6
NOTE: If applying upgrade for SNMP Web Server in LAN, FTP server IP address will be IP
address of current PC in LAN. If applying upgrade for SNMP Web Server in specific
Step2: Click “Browse” button to choose program file. Refer to Diagram 4-7.
Diagram 4-7
Step3: Click “Upgrade” button to execute upgrade action. Refer to Diagram 4-8.
18
Diagram 4-8
Step4: When upgrade is complete, you may check the message in output window. Refer to
Diagram 4-9.
Diagram 4-9
NOTE: If abnormal situation occurs during upgrade process, the system will automatically
re-start the upgrade operation. If this interruption occurs five times, system will
automatically stop this operation. At this time, please check if LAN is working fine or
19
not.
Diagram 4-10
A. Version setting:
You can set SNMP protocol version. It also supports SNMP V3 protocol to monitor data.
Select device: Choose to set SNMP protocol version for selected SNMP devices on the
window list.
Select all: Choose to set SNMP protocol version for all SNMP devices on the window
list.
Choose SNMP protocol version, the default is V2. If you choose V3, you should also set
B. Password:
Select device: Choose to change password for selected SNMP device on the window
list.
Select all: Choose to change passwords for all SNMP devices on the window list
20
Enter original password, new password and re-enter new password to confirm. Then, click
Diagram 4-11
NOTE: The SNMP device could provide 2 static trap addresses and 8 dynamic trap
dynamic trap address is inactive for over 10 minutes, SNMP device will
message about UPS status will be sent to the specified users via mobile phone.
21
Step 1 Select SMS. Refer to Diagram 4-12.
Diagram 4-12
Step 3 Enter mobile phone numbers in “Phone no.” column and click “Add” button to
add phone no. in Recipients. To delete numbers, simply select phone no. from
Step 4 Click “Apply” button to save all changes. The “Test” button can be used to send
a test SMS to confirm the correct operation. If all parameters are set up
correctly, system will send a test message to all receivers and pop up a
4-14)
NOTE: This SMS setting is for testing only. Be sure to enter all settings in SMS page of
SNMP web server or ViewPower Pro software. For the detailed settings, please check
section 3.4.3 in SNMP web management manual or 5.8.4 in ViewPower Pro software
manual.
22
Diagram 4-13
Diagram 4-14
NOTE: It’s required to plug-in GSM Modem if sending SMS to mobile phone.
23
4.4. Language
SNMP Web Manager offers 12 languages:
√ Chinese(Simplified)
√ Chinese(Traditional)
√ English
√ German
√ Italian
√ Polish
√ Portuguese
√ Russian
√ Spanish
√ Turkish
√ Ukrainian
√ French
4.5. Help
About: Click “Help” menu and select “About” item. It represents the copyright
Help: Click “Help” menu and select “System help” item. It will open the help manual.
24