Assignment No. 04.pdf STD STRUCTURAL ELEMENTS OD

This document outlines an assignment for a Civil Engineering course focused on the design of a reinforced concrete frame for an industrial building. It includes specific tasks related to checking slenderness, calculating design moments, assessing torsional reinforcement, performing interaction checks, and detailing reinforcement. The assignment is due on May 5, 2025, and is worth 5 marks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views2 pages

Assignment No. 04.pdf STD STRUCTURAL ELEMENTS OD

This document outlines an assignment for a Civil Engineering course focused on the design of a reinforced concrete frame for an industrial building. It includes specific tasks related to checking slenderness, calculating design moments, assessing torsional reinforcement, performing interaction checks, and detailing reinforcement. The assignment is due on May 5, 2025, and is worth 5 marks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Department of Civil Engineering

Course Code/Title: Assessment Activity: Semester:

(CV-362) Assignment No. 4 Fall - 2024

Elements of Structure Design (3+1)

Date: OBE Targets: Weightage:

21st April 2025 [CLO-2] - [PLO-2] – C-3 5 marks

Submission Deadline: 5th May 2025

Teacher Name: Engr. Sumaira Ismail

Question 1: Solve the following

You are tasked with designing a reinforced concrete frame for an industrial building.
A corner column of the frame is subjected to combined axial load, bending, and torsion due to the
following conditions:

 Axial Load Pu=1200 KN (ultimate load)


 Uniaxial Bending about the strong axis with Mu=80 kN
 Torsional Moment Tu=60 kN due to unsymmetrical loading from attached beams
 Clear height between floors = 5.5 meters
 Column cross-section initially assumed: 400 mm × 600 mm (width × depth), oriented so 600
mm is along bending
 Concrete grade: f'c = 40 MPa
 Reinforcing steel: fy = 500 MPa

Additional Information:

 The column is slender in the major axis (effective length factor k=1.0, and effective length
Le=5.5m.
 Moment magnification must be considered due to slenderness effects according to the ACI
Code (or similar).
 The column is assumed to be fixed at the base and pinned at the top

Tasks:

1. Check slenderness:
o Determine whether the column is slender by comparing Le/r to the limit (where r is
radius of gyration).
o If slender, apply moment magnification.

Fall 2024 0 of 2
Department of Civil Engineering

2. Calculate the design moment:


o Magnify the given moment Muaccording to the slenderness effect using the
appropriate formula.
3. Torsion Design:
o Check if torsional reinforcement is required according to the ACI/Eurocode threshold
(compare Tu against limit Tth).
o If required, determine the torsional reinforcement:
 Amount of closed stirrups (for shear flow)
 Longitudinal bars (for resisting combined torsion and bending).
4. Interaction Check:
o Perform a simplified check of the combined axial load, bending, and torsion using
an interaction diagram or appropriate code formulas.
5. Detail the reinforcement:
o Longitudinal and transverse reinforcement for the column considering all combined
actions.
o Provide a sketch showing reinforcement layout and torsional stirrups.