PVL 144 en
PVL 144 en
PVL 144 en
Model: PVL-144
High Temperature and Low Light Performance 20 Year Warranty on Power Output at 80% Quick-Connect Terminals* and Adhesive Backing Bypass Diodes for Shadow Tolerance UL 1703 Listed to 600 VDC IEC 61646 v1 certified IEC 61646 v2 and 61730, TUV certification pending
144 Wp
Performance Characteristics Rated Power (Pmax): Production Pmax Tolerance: 5 % Construction Characteristics Dimensions: Weight: Output Cables: By-pass Diodes: Encapsulation: Adhesive: Cell Type: Length: 5486 mm (216"), Width: 394 mm (15.5"), Depth: 4 mm (0.2"), 16 mm (0.6") including potted terminal housing assembly 7.7 kg (17.0 lbs) 4 mm2 (12 AWG) cable with weatherproof DC rated quick-connect terminals* 560mm (22) length. Connected across every solar cell Durable ETFE high light-transmissive polymer Ethylene propylene copolymer adhesive-sealant with microbial inhibitor 22 triple junction amorphous silicon solar cells 356 mm x 239 mm
Qualifications and Safety Listed by Underwriters Laboratories for electrical and fire safety (Class A Max. Slope 2/12, Class B Max. Slope 3/12, Class C Unlimited Slope fire ratings) for use in systems up to 600 VDC.
Flexible
Laminate Standard Configuration Photovoltaic laminate with potted terminal housing assembly with output cables and quick-connect terminals* Application Criterion
Lightweight
New or qualified new roof installations Installation by certified installers only Installation temperature between 10 C - 40 C (50 F - 100 F) Maximum roof temperature 85 C (185 F) Minimum slope: 5/8:12 (3) Maximum slope 21:12 (60) Membrane: Select EPDM and TPO substrates from approved manufacturers only Metal: PVDF Coated (Galvalume or Zincalume ) steel metal roofing pan with flat surface (without pencil beads or decorative stippling) and 406 mm (16) minimum width
No-Glass
Durable
Shadow Tolerant
Refer to manufacturers installation guide for approved substrates and installation methods *e.g., Multi-Contact (MC) Connectors
High Temp Performance
#AA5-3636-02
Model: PVL-144
IV Curves at various Levels of Irradiance at Air Mass 1.5 and 25 C Cell Temperature
5486 (216.0")
800 W/m2
Current (A)
10
11
12
13
14
15
16
17
18
19
20
21
22
PVL-144
Quick-Connect Terminals
All measurements in mm. Inches in parentheses. Tolerances: Length: 5 mm (1/4"), Width: 3 mm (1/8")
Voltage (V)
Electrical Specifications STC (Standard Test Conditions) (1000 W/m2, AM 1.5, 25 C Cell Temperature) Maximum Power (Pmax): 144 W Voltage at Pmax (Vmp): 33.0 V Current at Pmax (lmp): 4.36 A Short-circuit Current (Isc): 5.3 A Open-circuit Voltage (Voc): 46.2 V Maximum Series Fuse Rating: 8 A Temperature Coefficients (at AM 1.5, 1000 W/m2 irradiance) Temperature Coefficient (TC) of Isc: 0.001/K(0.10%/C) Temperature Coefficient (TC) of Voc: -0.0038/K (-0.38%/C) Temperature Coefficient (TC) of Pmax: 0.0021/K (-0.21%/C) Temperature Coefficient (TC) of Imp: 0.001/K (0.10%/C) Temperature Coefficient (TC) of Vmp: -0.0031/K (-0.31%/C)
y = yreference [1 + TC (T- Treference)]
Notes: 1. During the first 8-10 weeks of operation, electrical output exceeds specified ratings. Power output may be higher by 15 %, operating voltage may be higher by 11 % and operating current may be higher by 4 %. 2. Electrical specifications are based on measurements performed at standard test conditions of 1000 W/m2 irradiance, Air Mass 1.5, and cell temperature of 25 C after stabilization. 3. Actual performance may vary up to 10 % from rated power due to low temperature operation, spectral and other related effects. Maximum system open-circuit voltage not to exceed 600 VDC per UL. 4. Specifications subject to change without notice.
Your UNI-SOLAR Distributor:
NOCT (Nominal Operating Cell Temperature) (800 W/m2, AM 1.5, 1 m/sec. wind) Maximum Power (Pmax): 111 W Voltage at Pmax (Vmp): 30.8 V Current at Pmax (lmp): 3.6 A Short-circuit Current (Isc): 4.3 A Open-circuit Voltage (Voc): 42.2 V NOCT: 46 C
Global Headquarters Sales & Manufacturing United Solar Ovonic LLC 2956 Waterview Drive Rochester Hills, MI 48309 Tel: 248.293.0440 Fax: 248.844.1214 Toll Free (USA): 800.528.0617 [email protected] European Sales Office United Solar Ovonic Europe GmbH Trakehner Strasse 7-9 D-60487 Frankfurt am Main Germany Tel: +49.69.7137667. 20 Fax: +49.69.7137667. 67 [email protected] Southern European Sales Office United Solar Ovonic Europe GmbH Via Monte Baldo, 4 I-37069 Villafranca (VR) Italy Tel: +39.045.8600982 Fax: +39.045.8617738 [email protected] www.uni-solar.com A subsidiary of Energy Conversion Devices, Inc. (Nasdaq: ENER)
#AA5-3636-02