Midea Temperature Control Solution For Data Center - CDU
Midea Temperature Control Solution For Data Center - CDU
MBT
CONTENTS
Part 1 Part 2
ART 1
Data Center Temperature Solutions
Midea's Solutions for Data Center
IEC DEC
Indirect evaporative cooling Direct evaporative cooling
Row/Array/Room
-level CRAC
Fluorine pump
out door unit
Server chips do not directly contact the cooling liquid, but dissipate heat by directly
contacting the liquid-filled cold plate or by conducting heat to the cold plate
through a heat-conducting component (the cold plate is usually a closed cavity
made of high thermal conductivity metals such as copper and aluminum), and then
the heat is taken away by the circulating liquid inside the cold plate.
The cold plate liquid cooling data center cooling system is mainly composed
of two parts: the outdoor (primary side) and the indoor (secondary side).
The primary side reduces the temperature of the coolant by exchanging
heat with the heat-generating components through the coolant. The
secondary side completes the exchange of heat between the heat-
generating components and the coolant, and the liquid temperature rises to
take away the heat from the components.
During operation, the coolant in the cooling tower outside the data center is
circulated by the indoor cooling distribution unit (CDU) to provide power. The
secondary side of the CDU outputs the heat liquid and directly exchanges heat
with the high-heat electronic components (CPU, GPU, memory, etc.) in the
server through the heat-conducting cold plate. The formed hot liquid is output
to the outdoor cooling tower by the CDU for cooling, thus forming the entire
circulation process. In the cold plate liquid cooling system, devices or units with
lower heat generation such as hard disks and power supplies still use air cooling
for heat dissipation.
CDU product introduction
Cooling Distribution Units (CDUs) are heat management devices based on liquid cooling technology. CDUs use liquid-to-liquid heat
exchangers to transfer heat from high-power components such as CPUs, VRDs, and GPUs in the secondary side circulating water system
to the primary side circulating water system, and then circulate the heat to the cooling tower through the primary side circulating water
to remove it from the data center. CDU provides secondary side flow distribution, pressure control, and prevents secondary side
condensation.
CDU generally includes a pump, which circulates the coolant through a pipeline or channel network, distributing it to various components
such as servers, processors, or other high-heat components that need to be cooled. CDU can adjust and control the flow rate, temperature,
and flow velocity of the coolant.
Depending on the specific situation, CDU has different functional configurations, such as sensors, monitors, flow control valves, etc. In
addition, CDU can also filter impurities in the coolant, keep the system clean, and prevent damage to other equipment components.
CDU has an intelligent controller with operational logic, automatic diagnosis and troubleshooting, protection and warning functions, as well
as intelligent flow, pressure and temperature control, which can manage system performance to meet peak demand.
Application of CDU products
Primary Secondary
side side
Cooling
Hydraulic
tower
module
Secondary pipeline
Advantages of using CDU products
Compared to air-cooled and liquid-cooled Temperature regulation is precise, reducing the risk of hardware Customized design based on actual needs,
heat dissipation, CPLC has better temperature failure caused by high temperatures; flexibly responding to the heat dissipation
regulation and improves energy utilization Filtering the coolant reduces the data center's requirements for requirements of various computing devices.
rate, reducing electricity costs. coolant cleanliness, reducing the risk of corrosion and scaling.
Midea: External cabinet-type CDU suitable for large-scale (recommended for more than 5
cabinets) one-time deployment scenarios.
CDU product introduction
Power specifications 3PH +PE,380~415V,50/60Hz Voltage range (-15% +10%) frequency range ±3Hz
Operating temperature range +4 ~ +45℃
Operating humidity range 5%~95%RH
Storage temperature range -40 ~ +70℃
Operating environment Storage humidity range 5%~95%RH No condensation
Temperature control accuracy ±1℃
Within the limited altitude, the increased altitude can reduce
Altitude (m) ≤4000m
the available usage
Protection level IP20
Performance 1: 364kW @ Primary side inlet/outlet water temperature:
35/43℃, Secondary side inlet/outlet water temperature: 40/50℃
Cooling capacity (kW) Cooling medium: Primary side: water; Secondary side: water
Performance 2: 455kW @ Primary side inlet/outlet water temperature:
35/43℃, Secondary side inlet/outlet water temperature: 40/50℃
Performance 1: ≥31.2m³/h Secondary side flow rate; Cooling medium: Primary side:
Flow rate (m³/h)
Performance 2: ≥39m³/h water; Secondary side: water
Performance 1: ≤6.7kW
Total power Cooling medium: Primary side: water; Secondary side: water
Performance 2: ≤10.1kW
Performance 1: ≥ 180 kPa Performance 2: ≥ 250 kPa
Available head on secondary side Cooling medium: Primary side: water; Secondary side: water
Primary/Secondary side: compatible with ethylene glycol aqueous solution,
Cooling medium
General technical parameters propylene glycol aqueous solution or water;
Noise (1m)(dBA) < 72dBA (when running at full load)
Primary side filtering accuracy: 50 mesh; Secondary side filtering accuracy:
Filtering level of filter
270 mesh;
CDU CDU Rack Rack Rack Rack Rack RackRack Rack Rack Rack Rack Rack Rack Rack Rack Rack Rack
CDUCDU Rack Rack Rack Rack Rack RackRack Rack Rack Rack Rack Rack Rack Rack Rack Rack Rack
Magnetic suspension VFD centrifugal chiller Direct drive VFD centrifugal chiller Gear-drive VFD centrifugal chiller
Cooling capacity range: 170RT ~ 1800RT Cooling capacity range: 250RT ~ 2200RT Cooling capacity range of single head: 500RT ~ 3000RT
Ultra high energy efficiency: full range of COP/NPLV super High energy efficiency: COP/NPLV meet the first level of energy Cooling capacity of double heads series: 4600RT ~ 6000RT
level energy efficiency efficiency
Magnetic levitation compressor with independent
intellectual property rights
more constant
bearings mode
Small pressure ratio compressor for data center scenario, high outlet water temperature of 20 ℃, quick start, 0 temperature difference, AI anti-surge
Water System-High Efficiency Terminal
MCH 250 Floorless design reduces initial investment by 10%
(250KW)
15/23 ℃ high water temperature design, high cooling efficiency
Using magnetic suspension chiller, PUE can be as low as 1.3 (South China)
12KW/cabinet high-density scheme, supporting flexible capacity expansion
Customizable products with different cooling capacity
Wind Wall
MCD/U 030-180
RCH 030-065
(30KW-180KW)
(30KW-65KW)
• Flexible collocation, can be matched with magnetic suspension centrifugal chiller, screw chillers;
Product characteristics of high temperature
chilled water fan wall
According to meteorological conditions and installation requirements in different regions, MBT has introduced multi-scenario integrated
solutions such as indirect evaporative cooling (IEC), direct evaporative cooling (DEC) and heat recovery DEC units.
It has super high applicability in system energy efficiency, delivery mode, modularization and standardization, and MBT have completed the
self-developed key components(compressors and fans, etc.) and the construction of test laboratory.
Hea
t
reco
very Return Air
sect
ion
Exhaust
Dire
ct
fres
h Air Supply
air
sect
ion
Fresh air
Indirect evaporative cooling 260-400 kw Direct evaporative cooling 190-290 kw Heat recovery type evaporative cooling 210 kw
Wind system: test laboratory to ensure
the reliability
Parameter Unit Ability
Air Volume m³/h 150000
External residual pressure Pa 40~1000
Indoor
Indoor air inlet temperature
side ℃ 24~45℃
operating temperature range
Row level
+
Solutions
Half cabinet Full cabinet air
(25KW) cooling (40 KW)
Room level
Solutions
+
It is suitable for new small and medium-sized data centers
and retrofitting projects.
High-efficiency gas fluorine pump scheme, PUE ≤ 1.25. Room level air cooling
The pipeline design and construction are simple, and the (25 ~ 100 kw)
MAU/MAD Series
initial investment is low.
ART 2
Case Applications
Project cases
Project Overview: Chongqing Science City West Yongwei Electric Park, with a total investment
of about 1.14 billion yuan, covering an area of about 9 mu, and a building area of about 5000
square meters. Equipped with a computing center with 400P computing power, the data center
adopts a prefabricated modular machine room form for rapid construction and delivery.
Supply: SCAF240GV (FC-I) *2 units of variable frequency air-cooled screw units with indirect
natural cooling function + 2 sets of liquid cooling hydraulic modules + 1 set of cold source group control
system + 10 CDU@305kw
Project cases
Cooling tower
CRAH/CDU
Hydraulic module
Hydraulic module
Project cases
Air-liquid / cold plate cooling tower
Cold storage tank
Hydraulic module
The liquid cooling module adopts CDU+ liquid cooling cabinet, and the two-layer liquid
cooling-cold plate cooling system includes two closed cooling towers and two chilled water
pumps, with a configuration of 1+1 backup.
Project Overview
The project is located in Guian New District, Guiyang City, Guizhou
Province. With total construction area of 15,000 square meters, the data center
built 4 buildings in phase I, each capable of accommodating 1200 8kW server
cabinets, with a total capacity of over 70,000 servers.
Design Overview
DEC Direct evaporative cooling solutions + 50% cold supplement from
chilled water system.
Emergency cold storage tank + Midea elevator + precision air conditionings
Year-round operation with PUE ≤ 1.2, design PUE 1.17.
System Introduction
1*CCWG800EVD + 2*CCWF800EV centrifugal chillers
30*Direct Ventilation AHU 85000 m3/h
20*Direct Ventilation AHU 54000 m3/h
IT Room-Direct Evaporative Cooling AHU 1/2
Return
The unit consists of air inlet section, filter section, silencing section, refrigeration air
section, air supply section and control cabinet.
How it works: Air Inlet Filter Noise Refriger Air
Section Section Reductin ation Supply
Fresh air passes through various functional sections to meet the set temperature
and humidity requirements, entering the data center. Fresh Air
Direct evaporative cooling is a process of enthalpy cooling where air and water air Supply
Note: Gui'an Midea Cloud Project customizes the chilled water coil cooling section on the
Direct Evaporative Cooling Principle
basis of standard evaporative cooling AHU products. The AHU coil is designed in consideration Diagram 50
of 100% load demand. The water chiller is designed in consideration of 50% cooling capacity, 40
(to,do) 60%
and the conditions for later expansion are reserved. To ensure that future extreme working O
t(°C)
30
室内 环 境
100 %
(tsf,dsf)
conditions are met and the stable operation needs of the data center are met; 20
(twb,o,dwb,o)
10
7%
4%
Provide equipment
power distribution and
realize intelligent control
Cooling Cold storage
direction direction
Medium and high water
21℃ temperature high efficiency
terminal
High efficiency frequency conversion
cooling tower
The maximum degree of
approximation under the design 15℃ 21℃
parameters is 3 ℃.
Architecture of Air-Liquid-Fluorine Fusion Refrigeration System in Laboratory Room The power density of single
cabinet in the machine room is 40
KW, of which 70% of the cabinet
heat dissipation is undertaken by
the cold plate liquid cooling
system, and the fluorine-water
heat exchange CDU is used. The
At the same time, fluorine pump AHU (DES air conditioning unit), liquid cooling technology remaining 30% of the cabinet
(fluorine-water exchange CDU) and SST power supply were introduced into the laboratory heat dissipation is undertaken by
the fluorine pump AHU.
room as technical pre-research and reserve, which made full preparations for Gui'an Meiyun The supply/return water
Project Overview: Huawei Cloud East China Data Center (Wuhu), with a
total area of 2600 acres, of which the first phase covers an area of 253 acres,
with a total construction area of about 170,000 square meters, and building
total area of 2600 mu, of which the first phase covers 253 mu, with a
Heshan Weihai Zhigu Pengcheng Cloud Brain Center Lhasa Ning Algorithm Big Data Center Gui'an Huawei Qixing Lake Data Center
Tencent Qingyuan Data Center Yantai Huawei Data Center China Mobile (Harbin) Data Center Guangzhou Baiyun Airport Data Center
Chengdu Industrial and Commercial Bank Beijing Unicom Huangcun Data Center China Telecom Beijing Technology Park Shanghai Metro Control Center
Thank You !