Exa 3

The document outlines a PLC program block named 'Main Program Sweep (Cycle)' for a CPU 1215C, detailing its properties, input variables, and network configurations. It includes various program elements such as timers, counters, and conditions for controlling outputs based on sensor inputs. The program is structured in ladder logic and incorporates real-time data handling for automation processes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views3 pages

Exa 3

The document outlines a PLC program block named 'Main Program Sweep (Cycle)' for a CPU 1215C, detailing its properties, input variables, and network configurations. It includes various program elements such as timers, counters, and conditions for controlling outputs based on sensor inputs. The program is structured in ladder logic and incorporates real-time data handling for automation processes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Totally Integrated

Automation Portal

Examen3 / PLC_1 [CPU 1215C AC/DC/Rly] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐ Author Comment Family
cle)"
Version 0.1 User-defined ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1:
Totally Integrated
Automation Portal

Network 1: (1.1 / 2.1)

%M0.0 %M0.1
"PB" "Contador".QU "Paso0"
S

%M0.5
"Paso4"
R

%M0.2 %MW126 %M0.3


"Tem"
"Paso1A" "Timer1".Q "Paso2"
<=
S
Real
45.0
%M0.2
"Paso1A"
%M2.0 IN_RANGE R
"Paso1B" "Timer1".Q Real

%M2.0
45.0 MIN "Paso1B"
%MW126 R
"Tem" VAL
75.0 MAX %M2.1
"Paso1C"
R
%M2.1 %MW126
"Paso1C" "Timer1".Q "Tem"
>=
Real
70.0

%M0.3 %M0.6 %M0.4


"Paso2" "SensorC" "Paso3"
S

%M0.3
"Paso2"
R

%M0.4 %M0.5
"Paso3" "Contador".QU "Paso4"
S

%M0.4
"Paso3"
R

%M0.1 %Q1.4
"Paso0" "Rosa"
S
%DB1
"Timer1"
TON
Time
IN Q
T#3s PT %MD108
ET "3segundos"

%M0.2 %Q1.2
"Paso1A" "Verde"
S

%Q1.5
"Calentador"

%DB2
"Timer2"
TON
Time
IN Q
T#6s PT %MD112
ET "6segundos"

%M2.0 %Q1.1
"Paso1B" "Amarillo"
S

%Q1.5
"Calentador"

%DB3
"Timer3"
TON
Time
IN Q
T#4s PT %MD116
ET "4segundos"

%M2.1 %Q1.0
"Paso1C" "Rojo"
S

%Q1.5
"Calentador"

%DB4
"Timer4"
TON
Time

2.1 ( Page1 - 3)
Totally Integrated
Automation Portal

Network 1: (2.1 / 2.1)


1.1 ( Page1 - 2)
Time
IN Q
T#2s PT %MD120
ET "2segundos"

%M0.3 %Q0.7
"Paso2" "Banda"

%M0.4 %Q1.1
"Paso3" "Amarillo"
R

%Q1.0
"Rojo"
R

%Q1.2
"Verde"
R
%DB5
"Contador"
CTU
Int
CU Q
%M2.3 %MW124
"Reset" R CV "Conta"
%MW0
"iteraciones" PV

%M0.5 %Q1.4
"Paso4" "Rosa"
R

%Q1.3
"Azul"

NORM_X SCALE_X
Int to Real Real to Int
EN ENO EN ENO
6912 MIN %MW64 25 MIN %MW126
%MW130 OUT "Voltaje" %MW64 OUT "Tem"
"ValorD" VALUE "Voltaje" VALUE
20736 MAX 100 MAX

You might also like