0% found this document useful (0 votes)
16 views2 pages

Bms2 Error Cod-Eng-1 Hyva

The document provides a comprehensive list of error codes for the BMS-2 system, detailing external and internal error codes along with their meanings, possible causes, and verification steps. It also includes status codes for the radio control system, indicating the operational state and potential issues. Additionally, notes are provided regarding specific error conditions and maintenance recommendations.

Uploaded by

MyFull
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views2 pages

Bms2 Error Cod-Eng-1 Hyva

The document provides a comprehensive list of error codes for the BMS-2 system, detailing external and internal error codes along with their meanings, possible causes, and verification steps. It also includes status codes for the radio control system, indicating the operational state and potential issues. Additionally, notes are provided regarding specific error conditions and maintenance recommendations.

Uploaded by

MyFull
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ERROR CODES LIST for the BMS-2 system (VC/PWM)

EXTERNAL ERROR CODES:

CODE FAULT POSSIBLE CAUSES TYPE POSSIBLE VERIFICATIONS


E00 Joystick 1 (AK1) operating with safety contact open. DK3 not properly connected, joystick faulty or deadband too low. VC/PWM Follow these steps:
E01 Joystick 2 (AK2) operating with safety contact open. DK4 not properly connected, joystick faulty or deadband too low. VC/PWM 1. Check the wirings under the joysticks for any possible electric false connection on wires and
E02 Joystick 3 (AK3) operating with safety contact open. DK5 not properly connected, joystick faulty or deadband too low. VC/PWM connectors.
E03 Joystick 4 (AK4) operating with safety contact open. DK6 not properly connected, joystick faulty or deadband too low. VC/PWM 2. Replace the joystick corresponding to the error code.
E04 Joystick 5 (AK5) operating with safety contact open. DK7 not properly connected, joystick faulty or deadband too low. VC/PWM 3. Call the post-sale service, so that the deadband software parameter can be verified.
E05 Joystick 6 (AK6) operating with safety contact open. DK8 not properly connected, joystick faulty or deadband too low. VC/PWM
E06 Joystick 7 (AK7) operating with safety contact open. DK9 not properly connected, joystick faulty or deadband too low. VC/PWM
E07 Joystick 8 (AK8) operating with safety contact open. DK10 not properly connected, joystick faulty or deadband too low. VC/PWM
Check if there are no shortcuts on the loads; the cable has not been damaged and the maximum
The maximum supplying current of the remote control unit (9Amp) has been supplied current to the loads doesn't exceed 9 Amp. If the
E08 Over current in the general circuit of E-STOP. (see also note 1) error code appears when you turn on the system, call the authorized service (see also note 1).
exceeded.
VC/PWM

E09 Overcurrent on a ON/OFF output (from OUT 1 to OUT 5 or Y0) Shortcut on an ON/OFF load or the ON/OFF output broken down. VC/PWM Check the ON/OFF loads. Verify the cable has not been damaged. If necessary, contact the authorized
E10 Overcurrent on a ON/OFF output (from OUT 6 to OUT 11). Shortcut on an ON/OFF load or the ON/OFF output broken down. VC/PWM service to check the remote control unit.
Check the power supply voltage of the remote control unit. If necessary, contact the authorized service
E11 Over voltage on the power supply. V_in > 35V (power supply voltage higher than 35 Volt)
VC/PWM to check the radio control .
Check the power supply voltage of the remote control unit. Verify the section of the electrical cable for
E12 Under voltage on the power supply. V_in < 8V (Power supply voltage lower than 8 Volt) the power supply: it has to be proportional to the load and to the length. If necessary, contact the
VC/PWM authorized service to check the remote control unit.
Voltage read back error on the Y0 output (safety valve). (see also Check if there is water in side the receiver box (see note 2). Verify that there are no shortcuts on the
E13 note 2) Safety valve broken, Y0 radio output broken or faults on the cable. VC/PWM ON/OFF loads and that the cable has not been damaged. If necessary, contact the authorized service
Voltage read back error on the OUT1 output (start radio). (see to check up the remote control unit.
E14 note 2) shortcut on an ON/OFF output, OUT1 of the radio broken or faults on the cable. VC/PWM
E15 Read back error for power supply voltage of valve 1. Remote control unit power output 1 faulty or electrovalve faulty. VC
E16 Read back error for power supply voltage of valve 2. Remote control unit power output 2 faulty or electrovalve faulty. VC
E17 Read back error for power supply voltage of valve 3. Remote control unit power output 3 faulty or electrovalve faulty. VC
E18 Read back error for power supply voltage of valve 4. Remote control unit power output 4 faulty or electrovalve faulty. VC
E19 Read back error for power supply voltage of valve 5. Remote control unit power output 5 faulty or electrovalve faulty. VC
E20 Read back error for power supply voltage of valve 6. Remote control unit power output 6 faulty or electrovalve faulty. VC
1. Check the output cable, probably it's faulty or there are shortcuts on it;
E21 Read back error for power supply voltage of valve 7. Remote control unit power output 7 faulty or electrovalve faulty. VC
2. Check the electro valves are working correctly;
E22 Read back error for power supply voltage of valve 8. Remote control unit power output 8 faulty or electrovalve faulty. VC
3. Try to exchange the plugs on the distributor. If the problem is due to the
E23 Read back error for proportional control voltage of valve 1. Remote control unit proportional output 1 faulty or electrovalve faulty. VC
E24 Read back error for proportional control voltage of valve 2. Remote control unit proportional output 2 faulty or electrovalve faulty. VC
hydraulic control block the errorcode will be changed. Otherwise the problem
E25 Read back error for proportional control voltage of valve 3. Remote control unit proportional output 3 faulty or electrovalve faulty. VC regards the radio or its cable.
E26 Read back error for proportional control voltage of valve 4. Remote control unit proportional output 4 faulty or electrovalve faulty. VC
E27 Read back error for proportional control voltage of valve 5. Remote control unit proportional output 5 faulty or electrovalve faulty. VC
E28 Read back error for proportional control voltage of valve 6. Remote control unit proportional output 6 faulty or electrovalve faulty. VC
E29 Read back error for proportional control voltage of valve 7. Remote control unit proportional output 7 faulty or electrovalve faulty. VC
E30 Read back error for proportional control voltage of valve 8. Remote control unit proportional output 8 faulty or electrovalve faulty. VC
There is a shortcut on a proportional valve. Disconnect one by one the valves so that you can localize
E31 Shortcut detected on a proportional valve. A proportional valve is faulty or the shortcut threshold (software parameter) is too low. PWM which one is faulty. If necessary, call the authorized service, so that the shortcut threshold can
be verified.

Ufficiotecnico Hetronic Italia Pagina 1 20/03/2006


E32 Error signal received from valve n° 1 (Sauer-Danfoss). Error state for valve n° 1. VC
E33 Error signal received from valve n° 2 (Sauer-Danfoss). Error state for valve n° 2. VC
E34 Error signal received from valve n° 3 (Sauer-Danfoss). Error state for valve n° 3. VC
E35 Error signal received from valve n° 4 (Sauer-Danfoss). Error state for valve n° 4. VC The hydraulic oil distributor (Sauer-Danfoss) has sent an error message to the
E36 Error signal received from valve n° 5 (Sauer-Danfoss). Error state for valve n° 5. VC radio remote control: verify the hydraulic control block.
E37 Error signal received from valve n° 6 (Sauer-Danfoss). Error state for valve n° 6. VC
E38 Error signal received from valve n° 7 (Sauer-Danfoss). Error state for valve n° 7. VC
E39 Error signal received from valve n° 8 (Sauer-Danfoss). Error state for valve n° 8. VC
Check the CAN-BUS wiring is properly connected and CAN-L and CAN-H are not inverted. If
E40 Communication Error (TIME-OUT) on the CAN-BUS. CAN-BUS is not properly connected or signal missing. VC/PWM
necessary, contact the authorized service to check up the remote control unit.
E41 START attempt without OK signal from TP7. TP7 not correctly used. VC/PWM Before pressing START on the radio control verify the enabling - signal from the machine.

E42 START attempt with a toggle-swich (or joystick) on. It's not possible to arm the system: a toggle-switch or a joystick is on. VC/PWM Before pressing START on the transmitter, check all the toggle-switches and joystick: they all have to
be off. If necessary, contact the authorized service to check up the remote control unit..
INTERNAL ERROR CODES:
CODE MEANING POSSIBLE CAUSES TYPE POSSIBLE VERIFICATIONS
E50 CPU test failed. Main base board faulty. VC/PWM
E51 WATCHDOG test failed. Main base board faulty. VC/PWM
E52 INTERRUPT test failed. Main base board faulty. VC/PWM
E53 TIMER test failed. Main base board faulty. VC/PWM
E54 EXTERNAL RAM test failed. Main base board faulty. VC/PWM
E55 INTERNAL RAM test failed. Main base board faulty. VC/PWM
E56 INTERNAL PRAM test failed. Main base board faulty. VC/PWM Call the authorized service to check up the remote control unit.
E57 FLASH memory test failed. Main base board faulty. VC/PWM
E58 STACK OVERFLOW detected. Software fault. VC/PWM
E59 Main loop time failed. Software fault. VC/PWM
E60 OP counter error. Software fault. VC/PWM
E61 Serial EEPROM checksum error. EEPROMs not programmied or faulty. VC/PWM
E62 HW internal error. Main base board faulty. VC/PWM

NOTE 1: An accidental inversion on the the power supply damages irreversibly the system, which showes permanently the E08 error code. Call the authorized service to substitute the electronic main base board.
NOTE 2: This error codes can occur if there is some humidity in the receiver. In this case eliminate every spot of water by applying a delicate throw of warm air.
Before closing again the receiver check the gasket under the cover so that no water can come inside.
DURING THE TRUCK WASHING DO NOT THROW WATER-JETS AGAINST THE RECEIVER BOX OR ITS CONNECTIONS.

NOTE: For error codes greater or equal than E-50, you need to reboot the receiver to reset the system.

LIST OF STATUS CODES FOR THE RADIO CONTROL BMS2 (VC/PWM)


xx4 RX power supply good, but the TX radio signal is missing (TX off, wrong radio channel or invalid system number).
xx3 The radio signal is too low (the system is working normally: this is just a warning message)
xx2 Emergengy push button (E-STOP) on the TX is pressed.
xx1 RX power supply and radio signal are good, but the system has not been armed yet by pressing the START switch.
xx0 The system has been armed and it's ready to be used in every function.

NOTES:
1. "x" rapresents any number. In normal conditions the RX status is completely shown by the last number on the display.
2. In normal conditions, the first number shows which proportional channel (AK) is used.
3. A blinking dot after the third digit shows that the radio signal is good (each flash is a valid telegramm received).
4.A blinking dot after the second digit shows that the red key is in PROGRAMM mode (in this case you can change the proportional min and max values)
00.0