The document outlines the project settings for a two-storey residential building designed for client Engr. Christian Karl Villaluz, with key details including design and analysis files. It specifies various design settings, reinforcement settings, and available rebar types, along with their minimum and maximum requirements. Additionally, it includes crack width settings and link styles for columns and shear walls.

Uploaded by

Dennis Simara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views3 pages

Column - Project Settings

The document outlines the project settings for a two-storey residential building designed for client Engr. Christian Karl Villaluz, with key details including design and analysis files. It specifies various design settings, reinforcement settings, and available rebar types, along with their minimum and maximum requirements. Additionally, it includes crack width settings and link styles for columns and shear walls.

Uploaded by

Dennis Simara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Page 1 of 3

PROJECT SETTINGS
Project Name : Two-Storey Residential Bldg
Client Name : Engr. Christian Karl Villaluz
Engineer Name : Angela L. Morada
Design File : C:\Users\Danilo Simara III\Dropbox (Old)
\PC\Documents\CM\Ilai\RCDC\Column\Column.rcdx
Analysis File : C:\Users\Danilo Simara III\Dropbox (Old)
\PC\Documents\CM\Ilai\STAAD\ILAYY.STD
Analysis Last Modified : 12/31/2024 12:03:15 AM

Design Settings
Ductile Design : No
Response Modification Coefficient : 3
Shear Walls With Boundary Elements : Yes
Live Load Reduction : No
Columns Braced : No
Optimize Design : Yes
Detail shear wall with equi-spaced Bar
: No
arrangement
Check Modulus of Rupture for columns with
: Yes
Axial Tension
Ignoring intermediate beams for merged levels : No
SW Definition(D/B) >= 4
Design Type : Resultant Moment (Combined Action)
Maximum Capacity Ratio : 1

Crack Width Settings


Crack Width ACI 224R-01 Check : No

Analysis Materials Used : No


Minimum Eccentricity Check : Simultaneously(Both Axes)

Reinforcement Settings
Column % Reinforcement
Minimum : 1
Maximum : 4

Shear Wall % Reinforcement


Minimum : 0.25
Maximum : 4

Longitudinal Bar Spacing

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmp612.tmp 12/31/2024
Page 2 of 3

Minimum : 75 mm
Maximum : 300 mm

Preferred Bar Spacing


Equi Spaced Arr. : 125 mm
Zone1 : 75 mm
Zone2 : 100 mm
Mid Zone : 200 mm

Link Spacing
Minimum : 125 mm
Maximum : 300 mm

Available Rebar
Rebar. Used : 8,10,12,13,14,16,18,20,22,25,28,32,36,40

Column Rebar
Minimum : 12
Maximum : 40

Shear Wall Rebar


Minimum : 10
Maximum : 10

Link Rebar
Minimum : 10
Maximum : 12

Links Style
Columns : Hoops
Walls : Ties
Tie Style : Open

Main Link with Boundary


: Master Link
Element

Round Off Factor


Spacing Round Off : 25 mm
Zone Round Off : 25 mm

Zone Bar Settings


Zonal
Equi-Spaced
No. of Bars/Spc Zonal Length No.of Bars/Spc(EF)
Edge

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmp612.tmp 12/31/2024
Page 3 of 3

Length Z1 Z2 Mid Z1 Z2 Mid


Nos Spc Nos Spc Nos Spc Nos Spc
300 2 143 0 0 0 0 0 0 0 0 0
400 3 122 0 0 0 0 0 0 0 0 0

file:///C:/Users/Danilo%20Simara%20III/AppData/Local/Temp/tmp612.tmp 12/31/2024