Hisense Air Conditioner Error Codes
Hisense Air Conditioner Error Codes
Repairman
How to Repair ?
by Tamirci AEG
Air Conditioning
Hisense Air Conditioner Error Codes Press the high power for 4 times in a row and the
Amana
trouble codes listed below will be displayed. The Error inquiry should be operate in the
stand-by state, keep 5 sec press and hold on the Emergency button, the error code will be Amica
displayed in 10 sec, then the indoor unit display will recovery to the original. If two or more Appliances
malfunction happened, each error code will be displayed alternatively. If the appliance
Arçelik
could save information under no power condition, then the error code can be inquired as
aforesaid with stand-by Ariston
state after power resume. Asko
Beko
Hisense Air Conditioner Error Code Belling
Blomberg
Error
Problem Boiler
Codes
Bosch
0 No trouble
Brands
1 Outdoor coil temperature sensor in trouble Candy
Cooking
3 Voltage transformer in trouble
Cooling
4 Current transformer in trouble
Daewoo
5 IPM module protection Delonghi
Dishwasher
7 Communication trouble
Dryer
8 Current overload control
Electrolux
9 Maximum current control Electronics
10 Communication trouble (between outdoor unit and driver unit) Error Codes
Faults
11 Outdoor EEPROM in trouble
Fisher & Paykel
13 Compressor exhaust temperature too high control
Franke
14 Outdoor ambient temperature sensor in trouble
Frigidaire
15 Compressor housing temperature control Fujitsu
General Electric
18 DC compressor fails to start
Gorenje
19 DC compressor out of step
Gree
33 Room temperature sensor in trouble Haier
35 Between wire remote controller and indoor unit communication trouble Hobart
Honeywell
36 Communication between the indoor and outdoor in trouble
Hoover
37 Water overbrimmed the pump
Hotpoint
38 Indoor EEPROM in trouble How to Repair ?
Indesit
40 Grid protection alarm (cabinet type)
İndustrial
41 Detecting failures by zero-crossing
Kelvinator
F0 Wire remote controller EEPROM failure. Change wire remote controller. Kenmore
Wire remote controller temperature sensor failure. Change wire remote Kenwood
F1
controller. Kitchenaid
F2 Wire remote controller clock IC failure. Change wire remote controller. Lennox
LG
Wire remote controller humidity sensor failure. Change wire remote
F3 Liebherr
controller.
Logik
Communication between main control board & Wiring remote controller
FE
Fault (display on wiring remote controller). Marq By Flipkart
Maytag
ER Communication between main control board &display board Fault.
McQuay
Midea
Content: When the evaporator pipe temperature is higher than 63C, the error code will
Miele
display
Mitsubishi
The root cause is may be one of the following: NEFF
Panasonic
1. It is normally for protection, When the indoor pipe temperature between
53C<T<63C, the outdoor fan motor will stop running. When the indoor coil Philips
temperature is higher than 63C, the error code will display. After the indoor pipe Refrigerator
temperature is lower than 49C, the air conditioner will restart normally.
Samsung
2. The indoor coil temperature sensor is loose;
3. The indoor coil temperature sensor is failure; Sharp
4. The indoor control board is failure. Siemens
Smeg
Error Code: E4
Sony
Content: When the indoor fan speed is lower than 200 rpm, the error code will display Teka
Trane
The root cause is may be one of the following:
Troubleshooting
1. There are something block the indoor fan motor; TurboChef
2. The fan motor cord connect loose;
Vacuum
3. The fan motor is failure;
4. The indoor control board is failure Vestel
Washing Machine
Error Code: EA
Westinghouse
Content: the error code will display when the communication between display board and Whirlpool
control board have in trouble Zanussi
1. The connection between the display board and control board is loose;
2. The indoor control board is failure.
3. The wiring of the display board is failure.
When the system stops running,press the “CHECK” and “↑↓” buttons, “SERVICE” and “00”
will display,”00” is index ,press “∧”and “∨” button to set the value, the index value is
displayed at the timer area .Each index value shows corresponding content,as follows:
Trouble code: 0
Troubles: No trouble
Trouble code: 1
Possible Cause:
Trouble code: 2
Possible Cause:
Trouble code: 5
Possible Cause:
1. Normal protection
2. Outdoor IPM control board is failure in the outdoor control board.
3. The compressor is failure.
Trouble code: 6
Possible Cause:
Trouble code: 8
Possible Cause:
1. Normal protection
2. The outdoor control board in trouble.
Trouble code: 9
Troubles: Maximum current control
Possible Cause:
1. Normal protection
2. The compressor is failure
Trouble code: 11
Trouble code: 13
Possible Cause:
Trouble code: 14
Possible Cause:
Trouble code: 15
Possible Cause:
Trouble code: 16
Possible Cause:
Trouble code: 18
Possible Cause:
1. Compressor is failture.
2. Outdoor IPM control board is failure in the outdoor control board.
Trouble code: 33
Trouble code: 34
Possible Cause:
Trouble code: 35
Troubles: Between wire remote controller and indoor unit communication trouble
Possible Cause:
Trouble code: 36
Possible Cause:
Trouble code: 37
Trouble code: 38
If the compressor fails when it is interrupted, the indoor unit’s LED flashes indicating the
specific trouble code. It flashes as many times as the number of the trouble code is.
Times: 1
Possible Cause:
Times: 2
Troubles: Compressor discharge temperature sensor in trouble
Possible Cause:
Times: 4
Times: 5
Possible Cause:
• Normal protection
• Outdoor IPM control board is failure in the outdoor control board.
• The compressor is failure.
Times: 6
Possible Cause:
Times: 8
Possible Cause:
• Normal protection
• The outdoor control board in trouble.
Times: 9
Possible Cause:
• Normal protection
• The compressor is failure
Times: 11
Times: 13
Possible Cause:
Times: 14
Possible Cause:
Times: 15
Possible Cause:
Times: 16
Possible Cause:
Times: 18
Possible Cause:
• Compressor is failture.
• Outdoor IPM control board is failure in the outdoor control board.
Times: 33
Possible Cause:
Times: 34
Possible Cause:
Times: 35
Troubles: Between wire remote controller and indoor unit communication trouble
Possible Cause:
Times: 36
Possible Cause:
Times: 37
Times: 38
• The power supply cord is unplugged; Plug into a grounded 3 prong outlet.
• Time-delay fuse or circuit breaker of the wrong capacity is being used; Replace with
a time—delay fuse or circuit breaker of the correct capacity.
• The power supply cord has tripped; Press and release RESET.
• A household fuse has blown, or a circuit breaker has tripped: Replace the fuse, or
reset the circuit breaker.
• The On/Off button has not been pressed; Press ON/OFF.
• The local power has failed: Wait for power to be restored.
• Too many appliances are being used on the same circuit; Unplug or relocate
appliances that share the same circuit.
• You are trying to restart the air conditioner too soon after turning off air
conditioner; Wait at least 3 minutes after turning off air conditioner before trying to
restart the air conditioner.
Air conditioner power supply cord trips (Reset button pops out)
• Disturbances in your electrical current can trip (Reset button will pop out) the power
supply cord; Press and release RESET (listen for click; Reset button will latch and
remain in) to resume operation.
• Electrical overloading, overheating, cord pinching or aging can trip (Reset button will
pop out) the power supply cord; After correcting the problem, press and release
RESET (listen for click; Reset button will latch and remain in) to to resume operation.
If the power cord fails to reset, contact a service technician.
NOTE: A damaged power supply cord must be replaced with a new power supply cord
obtained from the product manufacturer and must not be repaired.
• If the unit displays error code E5, the water container is full. Drain the water, see
“Draining the air conditioner”. After draining, the unit can be operated again.
• The air conditioner is not properly sized for your room; Check the cooling
capabilities of your portable air conditioner. Portable air conditioners are designed
as supplemental cooling to local areas within a room.
• The filter is dirty or obstructed by debris; Clean the filter.
• There is excessive heat or moisture, open container cooking, showers,etc. in the
room. Use afan to exhaust heat or moisture from the room; Try not to use heat-
producing appliances during the hottest part of the day.
• The louvers are blocked; Install the air conditioner in a location where the louvers
are free from curtains, blinds, furniture, etc.
The following cases may not always be a malfunction, please check it before asking for
service.
Analysis:
Analysis:
Analysis: This odor may come from another source such as furniture, cigarette etc, which is
sucked in the unit and blows out with the air.
Analysis:
Analysis: The sound may be generated by the expansion or contraction of the front panel
due to change of temperature.
Analysis: Mist appears when the room air becomes very cold because of cool air discharged
from indoor unit during COOLING or DRY operation mode.
Trouble: The compressor indicator(red) lights on constantly, and indoor fan stops.
Analysis: The unit is shifting from heating mode to defrost. The indicator will lights off
within ten minutes and returns to heating mode.
Leave a Comment
Name *
Email *
Website
Save my name, email, and website in this browser for the next time I comment.
Post Comment
Pro Kitchen & Laundry Home How to Reset Fridges & Freezers ?
© 2025 Repairman Water Heater Faults Washing Machine Faults Vacuum Cleaner Faults Tumble Dryer Faults Refrigerator Faults Ovens Faults
• Built with Microwave Faults Irons Faults Extractor Hood Faults Electric Wine Cellar Faults Electric Or Gas Hob Faults Dishwasher Faults
GeneratePress Coffee Maker Espresso Faults Air Conditioning Faults