0% found this document useful (0 votes)
4K views11 pages

Hisense Air Conditioner Error Codes

The document provides a comprehensive guide on error codes and troubleshooting for Hisense air conditioners, detailing specific error codes, their meanings, and potential solutions. It includes instructions for displaying error codes, common issues such as the unit not operating or not cooling, and steps to resolve these problems. Additionally, it offers advice for portable air conditioners, emphasizing the importance of proper maintenance and checks before seeking professional service.

Uploaded by

Mac Yfchai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4K views11 pages

Hisense Air Conditioner Error Codes

The document provides a comprehensive guide on error codes and troubleshooting for Hisense air conditioners, detailing specific error codes, their meanings, and potential solutions. It includes instructions for displaying error codes, common issues such as the unit not operating or not cooling, and steps to resolve these problems. Additionally, it offers advice for portable air conditioners, emphasizing the importance of proper maintenance and checks before seeking professional service.

Uploaded by

Mac Yfchai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Home Brands Troubleshooting Error Codes Commercial Equipment

Repairman
How to Repair ?

Hisense Air Conditioner Error Codes Categories

by Tamirci AEG

Air Conditioning
Hisense Air Conditioner Error Codes Press the high power for 4 times in a row and the
Amana
trouble codes listed below will be displayed. The Error inquiry should be operate in the
stand-by state, keep 5 sec press and hold on the Emergency button, the error code will be Amica
displayed in 10 sec, then the indoor unit display will recovery to the original. If two or more Appliances
malfunction happened, each error code will be displayed alternatively. If the appliance
Arçelik
could save information under no power condition, then the error code can be inquired as
aforesaid with stand-by Ariston
state after power resume. Asko

Beko
Hisense Air Conditioner Error Code Belling

Solutions Black & Decker

Blomberg
Error
Problem Boiler
Codes
Bosch
0 No trouble
Brands
1 Outdoor coil temperature sensor in trouble Candy

2 Compressor temperature sensor in trouble Coffee Maker

Cooking
3 Voltage transformer in trouble
Cooling
4 Current transformer in trouble
Daewoo
5 IPM module protection Delonghi

6 Over and under-voltage control Demirdöküm

Dishwasher
7 Communication trouble
Dryer
8 Current overload control
Electrolux
9 Maximum current control Electronics

10 Communication trouble (between outdoor unit and driver unit) Error Codes

Faults
11 Outdoor EEPROM in trouble
Fisher & Paykel
13 Compressor exhaust temperature too high control
Franke
14 Outdoor ambient temperature sensor in trouble
Frigidaire
15 Compressor housing temperature control Fujitsu

16 Anti-freeze or overload control Gaggenau

General Electric
18 DC compressor fails to start
Gorenje
19 DC compressor out of step
Gree
33 Room temperature sensor in trouble Haier

34 Indoor coil temperature sensor in trouble Heating


Error Hisense
Problem
Codes Hitachi

35 Between wire remote controller and indoor unit communication trouble Hobart

Honeywell
36 Communication between the indoor and outdoor in trouble
Hoover
37 Water overbrimmed the pump
Hotpoint
38 Indoor EEPROM in trouble How to Repair ?

39 Indoor fan motor operation abnormal IFB

Indesit
40 Grid protection alarm (cabinet type)
İndustrial
41 Detecting failures by zero-crossing
Kelvinator
F0 Wire remote controller EEPROM failure. Change wire remote controller. Kenmore

Wire remote controller temperature sensor failure. Change wire remote Kenwood
F1
controller. Kitchenaid

F2 Wire remote controller clock IC failure. Change wire remote controller. Lennox

LG
Wire remote controller humidity sensor failure. Change wire remote
F3 Liebherr
controller.
Logik
Communication between main control board & Wiring remote controller
FE
Fault (display on wiring remote controller). Marq By Flipkart

Maytag
ER Communication between main control board &display board Fault.
McQuay

Error Code: E2 Microwave

Midea
Content: When the evaporator pipe temperature is higher than 63C, the error code will
Miele
display
Mitsubishi
The root cause is may be one of the following: NEFF

Panasonic
1. It is normally for protection, When the indoor pipe temperature between
53C<T<63C, the outdoor fan motor will stop running. When the indoor coil Philips
temperature is higher than 63C, the error code will display. After the indoor pipe Refrigerator
temperature is lower than 49C, the air conditioner will restart normally.
Samsung
2. The indoor coil temperature sensor is loose;
3. The indoor coil temperature sensor is failure; Sharp
4. The indoor control board is failure. Siemens

Smeg
Error Code: E4
Sony
Content: When the indoor fan speed is lower than 200 rpm, the error code will display Teka

Trane
The root cause is may be one of the following:
Troubleshooting
1. There are something block the indoor fan motor; TurboChef
2. The fan motor cord connect loose;
Vacuum
3. The fan motor is failure;
4. The indoor control board is failure Vestel

Washing Machine
Error Code: EA
Westinghouse

Content: the error code will display when the communication between display board and Whirlpool
control board have in trouble Zanussi

The root cause is may be one of the following:

1. The connection between the display board and control board is loose;
2. The indoor control board is failure.
3. The wiring of the display board is failure.

Display of Error Codes:

Hisense Air Conditioner Display introduction

When the system stops running,press the “CHECK” and “↑↓” buttons, “SERVICE” and “00”
will display,”00” is index ,press “∧”and “∨” button to set the value, the index value is
displayed at the timer area .Each index value shows corresponding content,as follows:

Trouble code: 0

Troubles: No trouble

Trouble code: 1

Troubles: Outdoor coil temperature sensor in trouble

Possible Cause:

1. Outdoor coil temperature sensor is failure


2. Outdoor control board in trouble

Trouble code: 2

Troubles: Compressor discharge temperature sensor in trouble

Possible Cause:

1. Compressor discharge sensor is failure


2. Outdoor control board in trouble

Trouble code: 5

Troubles: IPM protection

Possible Cause:

1. Normal protection
2. Outdoor IPM control board is failure in the outdoor control board.
3. The compressor is failure.

Trouble code: 6

Troubles: Over and under-voltage control

Possible Cause:

1. Voltage of power supply is abnormal.


2. Outdoor control board in trouble.

Trouble code: 8

Troubles: Current overload control

Possible Cause:

1. Normal protection
2. The outdoor control board in trouble.

Trouble code: 9
Troubles: Maximum current control

Possible Cause:

1. Normal protection
2. The compressor is failure

Trouble code: 11

Troubles: Outdoor EEPROM in trouble

Possible Cause: Outdoor control board in trouble.

Trouble code: 13

Troubles: Compressor exhaust temperature too high control

Possible Cause:

1. Heat exchanger and indoor filter were dirty.


2. The refrigeration system was stopt.
3. Compressor discharge temperature sensor is failure.

Trouble code: 14

Troubles: Outdoor ambient temperature sensor in trouble

Possible Cause:

1. Outdoor ambient temperature sensor is failure


2. Outdoor control board in trouble

Trouble code: 15

Troubles: Compressor housing temperature protection

Possible Cause:

1. Compressor overheat protection sensor is failure


2. Outdoor control board in trouble

Trouble code: 16

Troubles: Anti-freeze or overload control

Possible Cause:

1. Indoor coil temperature sensor is failure.


2. Indoor control board in trouble.

Trouble code: 18

Troubles: Compressor fails to start

Possible Cause:

1. Compressor is failture.
2. Outdoor IPM control board is failure in the outdoor control board.

Trouble code: 33

Troubles: Room temperature sensor in trouble


Possible Cause:

1. Room temperature sensor is failure


2. Indoor control board in trouble

Trouble code: 34

Troubles: Indoor coil temperature sensor in trouble

Possible Cause:

1. Indoor coil temperature sensor is failure


2. Indoor control board in trouble

Trouble code: 35

Troubles: Between wire remote controller and indoor unit communication trouble

Possible Cause:

1. Wire remote controller in trouble.


2. Indoor control board in trouble.

Trouble code: 36

Troubles: Communication between the indoor and outdoor in trouble

Possible Cause:

1. Connection cable isn’t well connect


2. Indoor control board in trouble
3. Outdoor control board in trouble

Trouble code: 37

Troubles: Water overbrimmed the pump.

Possible Cause: Check the pump

Trouble code: 38

Troubles: Indoor EEPROM in trouble

Possible Cause: Indoor control board in trouble.

Indication on the Indoor Unit

Hisense Air Conditioner Remote Control Display

If the compressor fails when it is interrupted, the indoor unit’s LED flashes indicating the
specific trouble code. It flashes as many times as the number of the trouble code is.

Times: 1

Troubles: Outdoor coil temperature sensor in trouble

Possible Cause:

• Outdoor coil temperature sensor is failure


• Outdoor control board in trouble

Times: 2
Troubles: Compressor discharge temperature sensor in trouble

Possible Cause:

• Compressor discharge sensor is failure


• Outdoor control board in trouble

Times: 4

Troubles: Current transformer in trouble

Times: 5

Troubles: IPM protection

Possible Cause:

• Normal protection
• Outdoor IPM control board is failure in the outdoor control board.
• The compressor is failure.

Times: 6

Troubles: Over and under-voltage control

Possible Cause:

• Voltage of power supply is abnormal.


• Outdoor control board in trouble.

Times: 8

Troubles: Current overload control

Possible Cause:

• Normal protection
• The outdoor control board in trouble.

Times: 9

Troubles: Maximum current control

Possible Cause:

• Normal protection
• The compressor is failure

Times: 11

Troubles: Outdoor EEPROM in trouble

Possible Cause: Outdoor control board in trouble.

Times: 13

Troubles: Compressor exhaust temperature too high control

Possible Cause:

• Heat exchanger and indoor filter were dirty.


• The refrigeration system was stopt.
• Compressor discharge temperature sensor is failure.

Times: 14

Troubles: Outdoor ambient temperature sensor in trouble

Possible Cause:

• Outdoor ambient temperature sensor is failure


• Outdoor control board in trouble

Times: 15

Troubles: Compressor housing temperature protection

Possible Cause:

• Compressor overheat protection sensor is failure


• Outdoor control board in trouble

Times: 16

Troubles: Anti-freeze or overload control

Possible Cause:

• Indoor coil temperature sensor is failure.


• Indoor control board in trouble.

Times: 18

Troubles: Compressor fails to start

Possible Cause:

• Compressor is failture.
• Outdoor IPM control board is failure in the outdoor control board.

Times: 33

Troubles: Room temperature sensor in trouble

Possible Cause:

• Room temperature sensor is failure


• Indoor control board in trouble

Times: 34

Troubles: Indoor coil temperature sensor in trouble

Possible Cause:

• Indoor coil temperature sensor is failure


• Indoor control board in trouble

Times: 35

Troubles: Between wire remote controller and indoor unit communication trouble
Possible Cause:

• Wire remote controller in trouble.


• Indoor control board in trouble.

Times: 36

Troubles: Communication between the indoor and outdoor in trouble

Possible Cause:

• Connection cable isn’t well connect


• Indoor control board in trouble
• Outdoor control board in trouble

Times: 37

Troubles: Water overbrimmed the pump.

Possible Cause: check the pump

Times: 38

Troubles: Indoor EEPROM in trouble

Possible Cause: Indoor control board in trouble.

Hisense Portable AC Error Codes and Troubleshooting

Before calling for service, please try the suggestions below.

Air conditioner will not operate

• The power supply cord is unplugged; Plug into a grounded 3 prong outlet.
• Time-delay fuse or circuit breaker of the wrong capacity is being used; Replace with
a time—delay fuse or circuit breaker of the correct capacity.
• The power supply cord has tripped; Press and release RESET.
• A household fuse has blown, or a circuit breaker has tripped: Replace the fuse, or
reset the circuit breaker.
• The On/Off button has not been pressed; Press ON/OFF.
• The local power has failed: Wait for power to be restored.

Hisense Portable Air Conditioner Troubleshooting

Air conditioner blows fuses or trips circuit breakers

• Too many appliances are being used on the same circuit; Unplug or relocate
appliances that share the same circuit.
• You are trying to restart the air conditioner too soon after turning off air
conditioner; Wait at least 3 minutes after turning off air conditioner before trying to
restart the air conditioner.

Air conditioner power supply cord trips (Reset button pops out)

• Disturbances in your electrical current can trip (Reset button will pop out) the power
supply cord; Press and release RESET (listen for click; Reset button will latch and
remain in) to resume operation.
• Electrical overloading, overheating, cord pinching or aging can trip (Reset button will
pop out) the power supply cord; After correcting the problem, press and release
RESET (listen for click; Reset button will latch and remain in) to to resume operation.
If the power cord fails to reset, contact a service technician.
NOTE: A damaged power supply cord must be replaced with a new power supply cord
obtained from the product manufacturer and must not be repaired.

Air conditioner seems to run too much

• Is there a door or window open? ; Keep doors and windows closed.


• The current air conditioner replaced an older model; The use of more efficient
components may cause the air conditioner to run longer than an older model, but
the total energy consumption will be less. Newer air conditioners do not emit the ”
blast” of cold air you may be accustomed to from older units, but this is not an
indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER)
and capacity rating (in Btu/h) marked on the air conditioner.
• The air conditioner is in a heavily occupied room, or heatproducing appliances are in
use in the room; Use exhaust vent fans while cooking or bathing and try not to use
heat-producing appliances during the hottest part of the day. Portable air
conditioners are designed as supplemental cooling to local areas within a room. A
higher capacity air conditioner may be required, depending on the size of the room
being cooled.
• Air conditioner runs for a short time only, but room is not cool; Set temperature is
close to room temperature; Lower set temperature. See ” portable Air Conditioner
Use

Display error code

• If the unit displays error code E5, the water container is full. Drain the water, see
“Draining the air conditioner”. After draining, the unit can be operated again.

Air conditioner runs. but does not cool

• The filter is dirty or obstructed by debris; Clean the filter.


• Air outlet is blocked; Clear air outlet.
• Set temperature is too high; Lower set temperature.

Air conditioner cycles on and off too much

• The air conditioner is not properly sized for your room; Check the cooling
capabilities of your portable air conditioner. Portable air conditioners are designed
as supplemental cooling to local areas within a room.
• The filter is dirty or obstructed by debris; Clean the filter.
• There is excessive heat or moisture, open container cooking, showers,etc. in the
room. Use afan to exhaust heat or moisture from the room; Try not to use heat-
producing appliances during the hottest part of the day.
• The louvers are blocked; Install the air conditioner in a location where the louvers
are free from curtains, blinds, furniture, etc.

Hisense Air Conditioner Troubleshooting

Hisense Air Conditioner Troubleshooting

The following cases may not always be a malfunction, please check it before asking for
service.

Trouble: Does not run

Analysis:

• If the protector trip or fuse is blown.


• If the plug is not properly plugged.
• If batteries in the remote controller exhausted.
• Please wait for 3 minutes and start again, protector device may be preventing unit to
work
Trouble: No cooling or heating air

Analysis:

• Is the air filter dirty?


• Are the intakes and outlets of the air conditioner blocked?
• Is the temperature set properly?

Trouble: Ineffective control

Analysis: If strong interference(from excessive static electricity discharge, power supply


voltage abnormality presents, operation will be abnormal. At this time, disconnect from the
power supply and connect back 2-3 seconds later.

Trouble: Does not operate immediately

Analysis: Changing mode during operation, 3 minutes will delay.

Trouble: Peculiar odor

Analysis: This odor may come from another source such as furniture, cigarette etc, which is
sucked in the unit and blows out with the air.

Trouble: A sound of flowing water

Analysis:

• Caused by the flow of refrigerant in the air conditioner, not a trouble.


• Defrosting sound in heating mode

Trouble: Cracking sound is heard

Analysis: The sound may be generated by the expansion or contraction of the front panel
due to change of temperature.

Trouble: Spray mist from the outlet

Analysis: Mist appears when the room air becomes very cold because of cool air discharged
from indoor unit during COOLING or DRY operation mode.

Trouble: The compressor indicator(red) lights on constantly, and indoor fan stops.

Analysis: The unit is shifting from heating mode to defrost. The indicator will lights off
within ten minutes and returns to heating mode.

Air Conditioning, Error Codes, Hisense


Acson Air Conditioner Error Codes
Blueridge Air Conditioner Error Codes

Leave a Comment
Name *

Email *

Website

Save my name, email, and website in this browser for the next time I comment.

Post Comment

Solution Center Pages Posts

Brands About Us How to Reset Cookers & Hobs ?

Error Codes Contact How to Reset Dishwashers ?

Pro Kitchen & Laundry Home How to Reset Fridges & Freezers ?

How to Fix ? Privacy Policy How to Reset Microwaves ?

Repair Help Terms & Conditions How to Reset Tumble Dryers ?

© 2025 Repairman Water Heater Faults Washing Machine Faults Vacuum Cleaner Faults Tumble Dryer Faults Refrigerator Faults Ovens Faults
• Built with Microwave Faults Irons Faults Extractor Hood Faults Electric Wine Cellar Faults Electric Or Gas Hob Faults Dishwasher Faults
GeneratePress Coffee Maker Espresso Faults Air Conditioning Faults

You might also like