0% found this document useful (0 votes)
18 views1 page

Aa 3

The document outlines general construction notes, including dimensions, reinforcement details, and concrete specifications for a project. It emphasizes the importance of adhering to design drawings for construction joints and concrete pouring sequences, as well as the required material properties for concrete and backfill. Additionally, it includes guidelines for excavation and embankment construction to ensure structural integrity and compliance with engineering standards.

Uploaded by

Mohamed Sayed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

Aa 3

The document outlines general construction notes, including dimensions, reinforcement details, and concrete specifications for a project. It emphasizes the importance of adhering to design drawings for construction joints and concrete pouring sequences, as well as the required material properties for concrete and backfill. Additionally, it includes guidelines for excavation and embankment construction to ensure structural integrity and compliance with engineering standards.

Uploaded by

Mohamed Sayed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5

GENERAL KEY PLAN: N

GENERAL NOTES CONCRETE WORKS - JOINTS - EMBEDDED ITEMS


L A
- ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHEHRWISE INDICATED. - REINFORCEMENT IS SHOWN DIAGRAMMATICALLY ON THE DRAWINGS AND THEREFORE DOES NOT DEPICT THE PRECISE - CONSTRUCTION JOINTS SHALL BE AS SHOWN ON THE DESIGN DRAWINGS. NO CONSTRUCTION JOINTS SHALL BE QIB
POSITIONS OF BARS. OMITTED OR ADDED WITHOUT WRITTEN APPROVAL FROM THE DESIGNER.
- ALL CO-ORDINATES ARE IN METERS UNLESS NOTED OTHERWISE.
- DEVELOPMENT AND SPLICE LAP LENGTHS SHAL BE DETAILED IN ACCORDANCE WITH TABLE 2 UNLESS STATED OTHERWISE - CONSTRUCTION JOINTS SHALL BE CLEAN, FREE OF ALL LAITANCE AND PREWET TO PREVENT PREMATURE DRYING OF
- ALL ANGLES ARE IN DECIMAL DEGREES. ON THE DRAWINGS. THE FRESH CONCRETE. THEY WILL BE INTENTIONALLY ROUGHENED TO A FULL AMPLITUDE OF MINIMUM 3 mm.

- ALL DIMENSION ARE TO BE CHECKED AND VERIFIED BY THE CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION ON SITE. - THE SEQUENCE OF CONCRETE POURING SHALL BE MAINTAIN TO MINIMIZE SHRINKAGE AND CONCRETING SHALL NOT
THIS DRAWING MUST NOT BE SCALED AND ONLY WRITTEN OR CALCULATED DIMENSION ARE TO BE USED. TABLE 2. MINIMUN DEVELOPMENT LENGTH, ld (mm) FOR CONCRETE C32/40 AND STEEL GRADE 60 COMMENCE PRIOR APPROVAL FROM THE ENGINEER.

- THIS DRAWING IS TO BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, CIVIL, STRUCTURAL, MECHANICAL AND ELECTRICAL
ENGINEERING SERVICES DRAWINGS.
BAR DESIGNATION #3 #4 #5 #6 #7 #8 #9 #10 #11 DESIGN LIFE
E - THE FOLLOWING ABREVIATIONS ARE USED ON THESE DRAWINGS:
BAR DIAMETER (mm) 10 12 16 20 22 25 29 32 36 WITH REFERENCE TO THE DESIGN LIFE REQUIREMENTS AND FOR THE PURPOSE OF
THE DESIGN, STRUCTURAL ELEMENTS ARE DEFINED AS FOLLOWS:
AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY TRANSPORT OFFICIALS. HORIZONTAL BAR WITH MORE THAN 300mm
OF CONCRETE CAST BELOW THE BAR 440 590 730 880 1260 1450 1630 1810 1990 · WATER RETAINING STRUCTURES: DESIGN LIFE 100 YEARS
ACI AMERICAN CONCRETE INSTITUTE.
ANSI AMERICAN NATIONAL STANDARS INSTITUTE. · BUILDINGS AND OTHER PERMANENT STRUCTURES: DESIGN LIFE 100 YEARS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS.
ALL OTHER BAR 350 450 570 700 970 1150 1250 1400 1525
B BOTTOM / BEAM.
BF BOTH FACES.
BPT BREAK PRESSURE TANK
BR
C/C
BASE REINFORCEMENT.
CENTER TO CENTER.
TABLE 2. MINIMUN SPLICING LENGTH, ls (mm) FOR CONCRETE C32/40 AND STEEL GRADE 60 GRAPHIC SYMBOLS
CAJ CONTRACTION JOINT.
CCCSV CHILLER - COMPRESSOR - CHLORINATION - SURGE VESSEL BAR #3 #4 #5 #6 #7 #8 #9 #10 #11 TWL
CCSV CHILLER - COMPRESSOR - SURGE VESSEL SYMETRICAL TOP WATER LEVEL
CSV COMPRESSOR - SURGE VESEL BAR DIAMETER 10
CIP CAST IN PLACE. 12 16 20 22 25 29 32 36
CJ CONSTRUCTION JOINT.
HORIZONTAL BAR WITH MORE THAN 300mm NOTES:
CL CENTER LINE. 570 770 950 1150 1640 1890 2120 2350 2600
OF CONCRETE CAST BELOW THE BAR
DG DIESEL GENERATOR
E EXTRADOS SIDE.
EB ELECTRICAL BUILDING ALL OTHER BAR 460 590 740 910 1260 1500 1630 1820 1990
EF EACH FACE.
EGL EXISTING GROUND LEVEL.
EJ EXPANSION JOINT. - REINFORCEMENT SHALL BE INSTALLED SO THAT THE TOLERANCE ON CONCRETE COVER IS -5mm, +10mm.
F
FFL
FOUNDATION.
FINISH FLOOR LEVEL. - UNLESS SHOWN OTHERWISE ON THE DRAWING, LAPS ON ADJACENT BARS ON ANY FACE SHALL BE STAGGERED (OFFSET) DESCRIPTION OF BOND CONDITIONS
FGL FINISH GROUND LEVEL. BY NO LESS THAN LAP LENGTH. REFER TO DRAWING 07-152502-4800000647-RTC-DTR-DRG-020020 FOR THE ARRANGEMENT
I INTRADOS SIDE. OF STAGGERED LAPPED BARS.
JT JOINT.
LC COMPRESION LAP
Ld DEVELOPMENT LENGTH
LT
MAX
TENSION LAP.
MAXIMUN.
GEOTECHNICAL
MIN MINIMUM. - LOWER BOUND ALLOWABLE BEARING CAPACITY OF SOILS IS 200 kN/m2 FOR QUATERNARY SOILS AND 300 kN/m2 FOR LEAN OR CYCLOPEAN
D NA NOT APPLICABLE. CONCRETE FILLS AS PER SECTION 3.4.2.2 OF 07-152502-4800000647-RTC-INF-RPT-000003 STAGE 3C BOOK 3 SECTION A0200 GEOTECHNICAL
NTS NOT TO SCALE. ENGINEERING.
PCH PUNCHING REINFORCEMENT
PCJ PARTIAL CONTRACTION JOINT. -MAXIMUM ASSESSED SETTLEMENT WILL BE 30 mm (BELOW 40-60 mm LIMIT SET BY SBC 303) AS PER SECTION 3.4.2.3.3. OF 07-152502-4800000647-RTC-
R ROOF. INF-RPT-000003 STAGE 3C BOOK 3 SECTION A0200 GEOTECHNICAL ENGINEERING.
RC REINFORCED CONCRETE.
S SLAB. -MINIMUM MODULUS OF SUBGRADE REACTION FOR BUILDINGS ON QUATERNARY DEPOSITS WILL BE 7.500 kN/m3. FOR FOUNDATIONS ONTO
SS SECURITY SUPPORT CONCRETE FILLS OVER 1.5 M THICK , THESE VALUES WILL BE 25.000 kN/m3.
SYM SYMMETRY. WALLS SLABS SLABS
T TOP. t ≤ 250mm t > 250mm
t / THK THICK/THICKNESS. REFERENCE NUMBER DESCRIPTION
TOC
TSFL
TOP OF CONCRETE.
TOP SOIL FILLING LEVEL.
EARTHWORKS 'Poor' bond conditions 07-152502-4800000647-RTC-STR-MDL-000100 STRUCTURAL MPS1 BIM MODEL
TYP TYPICAL. - SOIL COVER ON TOP OF THE ROOF OF THE BUILDING SHALL NOT BE GREATER THAN 1m UNLESS NOTED OTHERWISE. 'Good' bond conditions
UNO UNLESS NOTED OTHERWISE.
W WALL. - ALL EARTHWORKS SHALL BE CARRIED OUT IN ACCORDANCE WITH 07-152502-4800000647-RTC-CIV-SPC-000003 BOOK 5 GENERAL SPECIFICATION
FOR CIVIL AND STRUCTURAL DIVISION 31 EARTHWORKS SECTION 1.5.1 AND CONTRACT SPECIFICATIONS.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
- STRUCTURAL AND GENERAL BACKFILL PROPERTIES WILL BE IN ACCORDANCE
CAST IN SITU CONCRETE WITH 07-152502-4800000647-RTC-CIV-SPC-000003 BOOK 5 GENERAL SPECIFICATION FOR CIVIL AND STRUCTURAL DIVISION 31 EARTHWORKS
SECTION 1.5.1 AND CONTRACT SPECIFICATIONS
VISUAL SCALE NOT APPLICABLE
- CAST IN-SITU CONCRETE SHALL HAVE A MINIMUN CHARACTERISTIC COMPRESSIVE STRENGTH OF 32 MPa (CYLINDER). STAGE:
1.5.1.1 STRUCTURAL BACKFILL
- BLINDING CONCRETE SHAL HAVE A MINIMUN CHARACTERISTIC COMPRESSIVE STRENGTH OF 16 MPa (CYLINDER).
THIS KIND OF FILL MUST COMPLY WITH THE PROPERTIES BELOW: 3C - DETAILED DESIGN
- CONCRETE COVERS FOR BAR REINFORCED CONCRETE ELEMENTS TO BE AS PER TABLE 1 BELOW:
MAXIMUM PARTICLE SIZE 80mm
AASTHO M145 TYPES A-1-a(0), A-1-b(0)
PLASTICITY INDEX ≤6
CBR INDEX 100 B 3C - SECOND ISSUE JJE 15.11.2024
TABLE 1. COVER FOR BAR REINFORCED CONCRETE ACID SOLUBLE SULPHATE 2% MAX. A 3C - FIRST ISSUE JJE 15.07.2024
NOMINAL COVER ACID SOLUBLE CHLORIDE 2% MAX.
STRUCTURAL MEMBER REV DESCRIPTION APP DATE
(mm) 1.5.1.2 GENERAL BACKFILL
C PURPOSE OF ISSUE:
CAST AGAINST AND PERMANENTLY IN
75 GENERAL OR ORDINARY BACKFILL MUST FULFIT THE FOLLOWING REQUIREMENTS:
CONTACT WITH GROUND ISSUED FOR APPROVAL
MAXIMUM PARTICLE SIZE 100mm
EXPOSED EXTERNAL SURFACES AND IN AASTHO TYPES A-5 OR BETTER CLIENT: PROJECT MANAGEMENT CONSULTANT:
CONTACT WITH GROUND/SOIL PLASTICITY INDEX NON PLASTIC
BACKFILLING: ACID SOLUBLE SULPHATE 2% MAX. (ONLY WITHIN 150mm OF STRUCTURES)
75
FOOTINGS, FOUNDATION SLABS, WALLS ACID SOLUBLE CHLORIDE 2% MAX. (ONLY WITHIN 150mm OF STRUCTURES)
EXTRADOS SIDE

- STRUCTURAL AND GENERAL BACKFILL MUST BE PLACED IN LAYERS NOT EXCEEDING 200 mm IN COMPACTED STATE AS PER PROJECT SPECIFICATIONS,
SCHEDULE 3B, SECTION 3100 4.5.4.
OTHER NON EXPOSED STRUCTURAL
ELEMENTS INSIDE BUILDINGS: 50 - FOR STRUCTURAL AND GENERAL BACKFILL - BACKFILL SHALL BE COMPACTED TO A MINIMUN OF 97 % COMPACTED DENSITY DETERMINED ON THE BASIS OF
BEAMS, COLUMNS, SLABS, WALLS
MODIFIED PROCTOR COMPACTION TEST.

- ADDITIONALLY, DRAIN MATERIAL WILL CONSIST OF GRAVEL OR COMBINATION OF GRAVEL AND SAND, PREFERABLY WITH PARTICLE GRADIATION SIZE BETWEEN
OTHER NON EXPOSED STRUCTURAL TWENTY AND SIXTY MILLIMETRES (20/60 MM). . MINiMUM THICKNESS AROUND PIPE OF 125 mm
50
ELEMENTS INSIDE TANKS
- IN GENERAL, EXCAVATIONS IN SOILS DEEPER THAN 1.5 m DEPTH CAN BE MADE AT 1V:2H TO THE REQUIERED FOUNDATION DEPTH WITHOUT SHORING. AS PER
SECTION 3.4.3.2.1 OF 07-152502-4800000647-RTC-INF-RPT-000003 STAGE 3C BOOK 3 SECTION A0200 GEOTECHNICAL ENGINEERING.
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):
FOR SHALLOWER DEPTHS, SLOPES MAY BE INDICATED IN DRAWINGS OR SPECIFIED BY CONSTRUCTION SITE ENGINEERS.
- SPACERS SHALL BE MADE OF CONCRETE OF SAME GRADE AS THE STRUCTURE FOR WHICH THEY ARE TO BE USED.
- EXCAVATION WORKS SHALL BE EXECUTED AS SHOWN IN CROSS SECTIONS ON THE DESIGN DRAWINGS, NO ADDITIONAL EXCAVATED OR FULFILLED AREAS WILL
- MAXIMUN SIZE OF AGGREGATES SHALL BE 20 mm. BE EXECUTED WITHOUT WRITTEN PREMISSION OR APPROVAL OF CONSTRUCTION SITE ENGINEERS.

- THE MAXIMUM ALLOWABLE WATER CONTENT RATIO SHALL BE 0.45 BY WEIGTH OF CEMENT. MINIMUN AND MAXIMUM CEMENTITIOUS - ALL EMBANKMENT CONSTRUCTION BACKFILLED OR CUT SLOPES AT THE SHALL BE PROTECTED AGAINST WASHOUTS OR EROSION BY A LAYER OF RIPRAP.
MATERIALS CONTENT
SHALL BE 350 AND 390 kg/M3. -WERE THE EXCAVATIONS BE DUG DEEPER THAN PROJECT GROUND LEVELS OR THAN ORDERED BY THE ENGINEER, THEY MUST BE FILLED UP WITH LEAN
CONCRETE OR CYCLOPEAN CONCRETE (OR CONCRETE MIX) TO THE PROPER LEVEL IN ACCORDANCE WITH THE ENGINEERS INSTRUCTIONS.
CYCLOPEAN CONCRETE IS FORMED BY A COMBINATION OF COARSE AGGREGATES AND CONCRETE AS PER GENERAL SPECIFICATION FOR ROAD AND BRIDGE
DESIGN DATA CONSTRUCTION. PART FIVE. CONCRETE, STEEL AND STRUCTURES (KSA, NOV 1998).

- A DESIGN LIFE OF 100 YEARS IS CONSIDERED FOR NON REPAIRABLE/MAINTENANCE ELEMENTS. -THEIR AGGREGATES MUST SATISFY THE FOLLOWING REQUIREMENTS:
B •COARSE AGGREGATE FOR CYCLOPEAN CONCRETE SHALL CONSIST OF NON-REACTIVE BROKEN STONE SPALLS OR BOULDERS RANGING IN SIZE FROM ONE DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:
C:\Users\VPG\Documents\07-152502-4800000647-TYP-STR-MDL-000150_vpguerrero.rvt

- SEISMIC LOAD HUNDRED (100) MILLIMETERS TO THREE HUNDRED (300) MILLIMETERS (ART. 5.01.7.2.2.2).
+ SITE CLASS: •CYCLOPEAN CONCRETE COARSE AGGREGATE SHALL BE SOAKED IN WATER PRIOR TO INCORPORATION INTO THE MIX AND EVENLY DISTRIBUTED IN THE DRAWN: RGD 13.11.2024
CLASS B AT MPS2, MPS3, MPS4 AND MR CONCRETE MATRIX WITH A MINIMUM COVER OF SEVENTY (70) MILLIMETRES.
CLASS D AT MPS1 •THE CYCLOPEAN CONCRETE: 400 MM, ASSUMING A COVER OF 70 MM (AS PER ART. 5.01.7.4) AND MAXIMUM AGGREGATE DIAMETER OF 300 MM. CHECKED: VMJ 14.11.2024 CHECKED:
+ RISK / IMPORTANCE FACTOR: CONCRETE TO BE POURED MUST HAVE A MINIMUM FCK = 10 MPA.
APPROVED: GDE 15.11.2024 APPROVED:
CATEGORY III FOR PUMPING STATIONS AND OTHER ANCILLARY STRUCTURES (I=1.25)
CATEGORY IV FOR MOUNTAIN RESERVOIR (I=1.50) -FOR ADDITIONAL SPECIFIC GUIDANCE, SEE ACI 207.1R-96 ON MASS CONCRETES AND RELEVANT GENERAL SPECIFICATION FOR ROAD AND BRIDGE
+ DESIGN SPECTRAL RESPONSE ACCELERATION AT SHORT PERIODS: CONSTRUCTION. PART FIVE. CONCRETE, STEEL AND STRUCTURES (KSA, NOV 1998) AND SBC 304-CR SECTIONS.
SDS=0.47g FOR PUMPING STATIONS MPS2, MPS3, MPS4 AND MR SCALE: NTS SHEET SIZE: A1
SDS=0.58g FOR PUMPING STATION MPS1
+ DESIGN SPECTRAL RESPONSE ACCELERATION AT 1 seg PERIOD: DISCIPLINE NAME:
SD1=0.11g FOR PUMPING STATIONS MPS2, MPS3, MPS4 AND MR
SD1=0.24g FOR PUMPING STATION MPS1 WATERPROOFING STRUCTURAL
- LANDSCAPPED ROOFS
DEAD LOAD: 22.50 kN/m2 CORRESPONDING TO 1.00 m MAX OF EARTH SOIL ON TOP
LIVE LOAD: 1.00 kN/m2
- STRUCTURAL CONCRETE BELOW GROUND OR IN CONTACT WITH SOIL OR BACKFILL SHALL BE PROTECTED FROM THE INGRESS OF MOISTURE, CHLORIDES OR
SULPHATES FROM THE GROUND BY A EXTERNAL WATERPROOFING SYSTEM, INCLUDING BLINDINGS, MEMBRANES AND COATING SYSTEMS.
MOUNTAIN PUMPING STATION 1
- BACKFILL SOIL LOADS:
INTERNAL ANGLE OF FRICTION: 30º
- A CONCRETE BLINDING SHALL BE PROVIDED UNDER ALL FOUNDATIONS WITH A MINIMUM THICKNESS OF 100 MM. NO CONCRETE SHALL BE CAST DIRECTLY
AGAINST SOIL. GENERAL NOTES
SATURATED DENSITY: 19 kN/m3
AT REST PRESSURE COEFFICIENT (ko) : 0.50 - WATERPROOFING SYSTEM APPLICABLE TO UNACCESIBLE OR NON REPAIRABLE ELEMENTS, SUCH AS FOUNDATIONS, SHALL GUARANTEE A DESIGN LIFE OF 100 PROJECT NAME:
ACTIVE PRESSURE COEFFICIENT (ka) : 0.33 YEARS.

- CONSTRUCTION /TEMPORARY LOADS: MAXIMUM SOIL STOCKPILLING FOR A TOTAL HEIGHT OF 1.60 M HAS BEEN CONSIDERED IN - WATERPROOFING SYSTEM APPLIED FOR FOUNDATOINS SHALL DEMONSTRATE A STATIC FRICTION COEFFICIENT OF NOT LESS THAN 0.48
D&B WTL FROM RE3 TO MOUNTAIN
DESIGN ON TOP OF ROOF IN ADDITION TO COMPACTION WORKS OF 2.50 kPa
- BLINDING CONCRETE LAYER MAY NOT BE REPLACED BY OTHER PROTECTION MEASURES THAT MAY IMPACT ON THE FRICTION COEFFICIENT. RESERVOIR
FOUNDATION EARTHING - WATER TANKS SHALL HAVE ADDITIONALLY AN INTERNAL WATERPROOFING LINING INCLUDING ROOF SOFFITS AND OTHER AREAS ABOVE WATER LEVEL, FOR A TROJENA
SERVICE LIFE AT LEAST 10 YEARS.
- PUMPING ROOM, ELECTRICAL BUILDING, NEOM ENERGY BUILDING AND ANY OTHER ROOM WITH SWITCH GEARS SHALL BE PROVIDED
WITH STEEL WIRE MESH #1 @ 300/300 LAID INSIDE SCREED AND INTERCONNECTED FOUNDATION EARTHING. - WATERPROOFING SYSTEM FOR WATER TANKS SHALL GUARANTEE WATERTIGHTNESS CLASS 3 (NO LEAKAGE PERMITTED) NEOM
A STEEL BAR REINFORCEMENT - ALL WATERBARS SHALL BE OF PVC AND APPROVED MANUFACTURE. THEY SHALL BE WITH CENTER BULB IN EXPANSION JOINTS AND RIBBED TYPE IN

- ALL REINFORCEING DEFORMED STEEL SHALL CONFORM TO ASTM A615 GRADE 60 AND SHALL HAVE A MINIMUN YIELD
CONSTRUCTION JOINTS
KINGDOM OF SAUDI ARABIA
STRENGTH fy=420 MPa. - WATERSTOP SHALL BE INSTALLED AS PER THE MANUFACTURES REQUIREMENTS INCLUDING FOR SMOOTH AND ROUGH / GREEN CUT CONCRETE JOINT
SURFACES. REGION ASSET CODE CONTRACT CODE
- WELDED WIRE FABRIC SHALL CONFORM TO ASTM A497 GRADE 75.
- EDGES OF CONCRETE ELEMENTS SHALL BE FLATTENED, I.E. BY PLAIN CONCRETE, TO ALLOW MINIMUM RADIUS OF WATERPROOFING MEMBRANE ACCORDING
- REINFORCEMENT NOTATION: FX-01 17#6@150 TO PROVIDERS SPECIFICATIONS 07 152502 4800000647
20/11/2024 10:43:50

- SPECIAL CARE SHALL BE TAKEN IN THE VICINITY OF CONSTRUCTION, EXPANSION AND CONTRACTION JOINTS TO ENSURE NO SEGREGATION AND FULL
STRUCTURAL ELEMENT LOCATION ( B, F, W, S, R) COMPACTION OF THE CONCRETE. DRAWING NUMBER
NOT FOR CONSTRUCTION
BAR SPACING, mm
REINFORCEMENT DIRECTION BAR DESIGNATION, inch/8 ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.
REINFORCEMENT MARK No. OF BARS
RTC STR DRG 010003 B
NEOM-NEN-PRC-009_TMP13_02.00