0% found this document useful (0 votes)
17 views3 pages

IP Scheme TR Wise

The document outlines the IP scheme for a network setup involving multiple TRs, detailing the connections and configurations for uplinks, interswitch communication, and device assignments. It specifies the use of SFP ports for uplinks, copper ports for IP cameras, speakers, and emergency telephones, and the termination of OFC at each TR. Additionally, it provides subnetting information and IP ranges for various devices within the network.

Uploaded by

ASTE CON
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views3 pages

IP Scheme TR Wise

The document outlines the IP scheme for a network setup involving multiple TRs, detailing the connections and configurations for uplinks, interswitch communication, and device assignments. It specifies the use of SFP ports for uplinks, copper ports for IP cameras, speakers, and emergency telephones, and the termination of OFC at each TR. Additionally, it provides subnetting information and IP ranges for various devices within the network.

Uploaded by

ASTE CON
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1.

The TR wise IP scheme is as below:


2. Port 2 (SFP ) to Port 1(SFP) & Vice versa to be used for Uplink for next switch with Tx /Rx of OFC patch cord changed
3. Port 3 (SFP) to Next Port-3 (SFP) to be used for interswitch communication. With OFC patch cord crossed.
4. Copper ports 5&6 for IP camera , 7 for Speaker & 8 for Emergency telephobe to be used on field switch.
5. 12 Core of OFC will be terminated at at each TR.
6. 4 Core will be used for Networking.
7. All above will be installed in 6 U wall mounted rack.
8. All equipment type are Din Rail Mounted Type.
Core Switch at STN 172.16.0.1 172.16.0.2
Tunnel-1 ( 3.5 Km) TR-1 ( Portal- Start from Sukhovi end) to TR-31 (Portal End towards Molvom end)

Distribution 172.16.0.0/24 172.16.0.10 -172.16.0.19 255.255.255.0 Core & Distribution Switch


Field Switches 172.16.1.0/24 172.16.1.1 -172.16.1.31 255.255.255.0 Field Switches
Camera 1 172.16.2.0/24 172.16.2.1 -172.16.2.31 255.255.255.0 CCTV
Camera 2 172.16.3.0/24 172.16.3.1 -172.16.3.31 255.255.255.0 CCTV
Speakers 172.16.4.0/24 172.16.4.1-172.16.4.31 255.255.255.0 PA SYSTEM
SOS Call Point 172.16.5.0/24 172.16.5.1 -172.16.5.31 255.255.255.0 PA SYSTEM

RJ45 Port on Switch 5 6 7 8


Tunnel-1 (1-5) Distribution Field Switches Camera-1 Camera-2 Speakers SOS Call Point Subnet Mask for All Ips
TR-1 172.16.0.10 172.16.1.1 172.16.2.1 172.16.3.1 172.16.4.1 172.16.5.1 255.255.255.0
TR-2 172.16.1.2 172.16.2.2 172.16.3.2 172.16.4.2 172.16.5.2 255.255.255.0
TR-3 172.16.1.3 172.16.2.3 172.16.3.3 172.16.4.3 172.16.5.3 255.255.255.0
TR-4 172.16.1.4 172.16.2.4 172.16.3.4 172.16.4.4 172.16.5.4 255.255.255.0
TR-5 172.16.1.5 172.16.2.5 172.16.3.5 172.16.4.5 172.16.5.5 255.255.255.0
TR-6 172.16.1.6 172.16.2.6 172.16.3.6 172.16.4.6 172.16.5.6 255.255.255.0
TR-7 172.16.1.7 172.16.2.7 172.16.3.7 172.16.4.7 172.16.5.7 255.255.255.0
TR-8 172.16.1.8 172.16.2.8 172.16.3.8 172.16.4.8 172.16.5.8 255.255.255.0
TR-9 172.16.1.9 172.16.2.9 172.16.3.9 172.16.4.9 172.16.5.9 255.255.255.0
TR-10 172.16.1.10 172.16.2.10 172.16.3.10 172.16.4.10 172.16.5.10 255.255.255.0
TR-11 172.16.1.11 172.16.2.11 172.16.3.11 172.16.4.11 172.16.5.11 255.255.255.0
TR-12 172.16.1.12 172.16.2.12 172.16.3.12 172.16.4.12 172.16.5.12 255.255.255.0
TR-13 172.16.1.13 172.16.2.13 172.16.3.13 172.16.4.13 172.16.5.13 255.255.255.0
TR-14 172.16.1.14 172.16.2.14 172.16.3.14 172.16.4.14 172.16.5.14 255.255.255.0
TR-15 172.16.1.15 172.16.2.15 172.16.3.15 172.16.4.15 172.16.5.15 255.255.255.0
TR-16 172.16.1.16 172.16.2.16 172.16.3.16 172.16.4.16 172.16.5.16 255.255.255.0
TR-17 172.16.1.17 172.16.2.17 172.16.3.17 172.16.4.17 172.16.5.17 255.255.255.0
TR-18 172.16.1.18 172.16.2.18 172.16.3.18 172.16.4.18 172.16.5.18 255.255.255.0
TR-19 172.16.1.19 172.16.2.19 172.16.3.19 172.16.4.19 172.16.5.19 255.255.255.0
TR-20 172.16.1.20 172.16.2.20 172.16.3.20 172.16.4.20 172.16.5.20 255.255.255.0
TR-21 172.16.1.21 172.16.2.21 172.16.3.21 172.16.4.21 172.16.5.21 255.255.255.0
TR-22 172.16.1.22 172.16.2.22 172.16.3.22 172.16.4.22 172.16.5.22 255.255.255.0
TR-23 172.16.1.23 172.16.2.23 172.16.3.23 172.16.4.23 172.16.5.23 255.255.255.0
TR-24 172.16.1.24 172.16.2.24 172.16.3.24 172.16.4.24 172.16.5.24 255.255.255.0
TR-25 172.16.1.25 172.16.2.25 172.16.3.25 172.16.4.25 172.16.5.25 255.255.255.0
TR-26 172.16.1.26 172.16.2.26 172.16.3.26 172.16.4.26 172.16.5.26 255.255.255.0
TR-27 172.16.1.27 172.16.2.27 172.16.3.27 172.16.4.27 172.16.5.27 255.255.255.0
TR-28 172.16.1.28 172.16.2.28 172.16.3.28 172.16.4.28 172.16.5.28 255.255.255.0
TR-29 172.16.1.29 172.16.2.29 172.16.3.29 172.16.4.29 172.16.5.29 255.255.255.0
TR-30 172.16.1.30 172.16.2.30 172.16.3.30 172.16.4.30 172.16.5.30 255.255.255.0
TR-31 172.16.0.19 172.16.1.31 172.16.2.31 172.16.3.31 172.16.4.31 172.16.5.31 255.255.255.0

Tunnel-2
No IP device will be installed.

Tunnel-3
TR-3 ( Portal- Start from Sukhovi end) to TR-11 (Portal End towards Molvom end)
1. The TR wise IP scheme is as below:
2. Port 2 (SFP ) to Port 1(SFP) & Vice versa to be used for Uplink for next switch with Tx /Rx of OFC patch cord changed
3. Port 3 (SFP) to Next Port-3 (SFP) to be used for interswitch communication. With OFC patch cord crossed.
4. Copper ports 5&6 for IP camera , 7 for Speaker & 8 for Emergency telephobe to be used on field switch.
5. 12 Core of OFC will be terminated at at each TR.
6. 4 Core will be used for Networking.
7. All above will be installed in 6 U wall mounted rack.
8. All equipment type are Din Rail Mounted Type.

Purpose Subnet IP Range Subnet Mask Device


Distribution 172.16.0.0/24 172.16.0.20 -172.16.0.29 255.255.255.0 Core & Distribution Switch
Field Switches 172.16.1.0/24 172.16.1.50 -172.16.1.60 255.255.255.0 Field Switches
Camera 1 172.16.2.0/24 172.16.2.50 -172.16.2.60 255.255.255.0 CCTV
Camera 2 172.16.3.0/24 172.16.3.50 -172.16.3.60 255.255.255.0 CCTV
Speakers 172.16.4.0/24 172.16.4.50-172.16.4.60 255.255.255.0 PA SYSTEM
SOS Call Point 172.16.5.0/24 172.16.5.50 -172.16.5.60 255.255.255.0 PA SYSTEM
RJ45 Port on Switch 5 6 7 8
Tunnel-3 (1 to 5) Management Field Switches Camera-1 Camera-2 Speakers Telephones Subnet Mask for All Ips
TR-1 172.16.0.20 172.16.1.50 172.16.2.50 172.16.3.50 172.16.4.50 172.16.5.50 255.255.255.0
TR-2 172.16.1.51 172.16.2.51 172.16.3.51 172.16.4.51 172.16.5.51 255.255.255.0
TR-3 172.16.1.52 172.16.2.52 172.16.3.52 172.16.4.52 172.16.5.52 255.255.255.0
TR-4 172.16.1.53 172.16.2.53 172.16.3.53 172.16.4.53 172.16.5.53 255.255.255.0
TR-5 172.16.1.54 172.16.2.54 172.16.3.54 172.16.4.54 172.16.5.54 255.255.255.0
TR-6 172.16.1.55 172.16.2.55 172.16.3.55 172.16.4.55 172.16.5.55 255.255.255.0
TR-7 172.16.1.56 172.16.2.56 172.16.3.56 172.16.4.56 172.16.5.56 255.255.255.0
TR-8 172.16.1.57 172.16.2.57 172.16.3.57 172.16.4.57 172.16.5.57 255.255.255.0
TR-9 172.16.1.58 172.16.2.58 172.16.3.58 172.16.4.58 172.16.5.58 255.255.255.0
TR-10 172.16.1.59 172.16.2.59 172.16.3.59 172.16.4.59 172.16.5.59 255.255.255.0
TR-11 172.16.0.29 172.16.1.60 172.16.2.60 172.16.3.60 172.16.4.60 172.16.5.60 255.255.255.0

You might also like