AVM 11 210 - Service

The document provides repair instructions for the DMP3035 component (Q906), emphasizing the need for ESD precautions during soldering. It includes guidelines for checking the output voltage of Q906 in standby mode and lists affected Philips models along with their respective PSU locations. If the output voltage is abnormal, replacement of Q906 is necessary to restore functionality.

Uploaded by

jack
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views3 pages

AVM 11 210 - Service

The document provides repair instructions for the DMP3035 component (Q906), emphasizing the need for ESD precautions during soldering. It includes guidelines for checking the output voltage of Q906 in standby mode and lists affected Philips models along with their respective PSU locations. If the output voltage is abnormal, replacement of Q906 is necessary to restore functionality.

Uploaded by

jack
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

DMP3035 failure Repair Tooling

Note: Q906 is ESD/EOS sensitive component, the human body electrostatic and soldering iron
electricity leakage will damage it, so technician must wear the ESD strap and the soldering iron must
connect to ground ensure do not leakage when soldering. The best way is remove the soldering iron
power plug to use the afterheat soldering.

HTS9221/924 PSU SCH for reference.

In standby model, G pin =H


and Dpin =0V is normal.
HTS9221&9241 Q906(DMP3035) loaction

Q906 location,

Q906 PIN1, check the frist pin mark


on Q906 when soldering
Some glue under the Q906, be
carefully when remove the Q906

In standby mode check Q906 5-8


pin output voltage , 0V is normal,
Q906 OK, check other component.
If 5-8ping have voltage output is
abnormal, need replace a new one.

After solder the Q906(DMP3035), measure Q906 pin4 =H and pin5-8 output voltage is 0V
then assembly the unit.
Effected model and each model DMP3035 location list
Effected Part No. Philips Model Location
HTS2551/12
HTS2551/98
HTS3551/12
PSU Q910
HTS3551/51
HTS3551/55
HTS3551/78
HTS4561/12
PSU Q909
HTS4562/12
HTS5131/12
HTS5131/51
HTS5131/78 PSU Q901
HTS5131/94
HTS5131/98
HTS5561/12
HTS5561/51
HTS5561/78
HTS5561/98
HTS5562/12
RCM003035-2001 HTS5581/12
HTS5581/93
HTS5581/98 PSU Q909
HTS5582/12
HTS5591/12
HTS5591/51
HTS5591/78
HTS5591/93
HTS5591/98
HTS5592/12
HTS5594/93 Not produce
HTS7201/12
PSU Q901
HTS7202/12
HTS8562/12
PSU Q909
HTS8562/98
HTS9221/12
HTS9221/98
PSU Q906
HTS9241/12
HTS9241/51

Defective set can not start correctly, measuring method refer to page 2 HTS9221/9241.