Note: Q906 is ESD/EOS sensitive component, the human body electrostatic and soldering iron
electricity leakage will damage it, so technician must wear the ESD strap and the soldering iron must
connect to ground ensure do not leakage when soldering. The best way is remove the soldering iron
power plug to use the afterheat soldering.
Q906 location,
After solder the Q906(DMP3035), measure Q906 pin4 =H and pin5-8 output voltage is 0V
then assembly the unit.
Effected model and each model DMP3035 location list
Effected Part No. Philips Model Location
HTS2551/12
HTS2551/98
HTS3551/12
PSU Q910
HTS3551/51
HTS3551/55
HTS3551/78
HTS4561/12
PSU Q909
HTS4562/12
HTS5131/12
HTS5131/51
HTS5131/78 PSU Q901
HTS5131/94
HTS5131/98
HTS5561/12
HTS5561/51
HTS5561/78
HTS5561/98
HTS5562/12
RCM003035-2001 HTS5581/12
HTS5581/93
HTS5581/98 PSU Q909
HTS5582/12
HTS5591/12
HTS5591/51
HTS5591/78
HTS5591/93
HTS5591/98
HTS5592/12
HTS5594/93 Not produce
HTS7201/12
PSU Q901
HTS7202/12
HTS8562/12
PSU Q909
HTS8562/98
HTS9221/12
HTS9221/98
PSU Q906
HTS9241/12
HTS9241/51
Defective set can not start correctly, measuring method refer to page 2 HTS9221/9241.