DMB51CM24
DMB51CM24
Multifunction
Type DMB51
• Selectable timerange 0.1 s to 100 h
• 7 knob selectable functions:
Op - delay on operate
In - interval
Io - interval on trigger open
Id - double interval
Dr - delay on release
R - symmetrical recycler ON first
Rb - symmetrical recycler OFF first
• Automatic or manual start
• Repeatability: ≤ 0.2%
• Output: 8 A SPDT relay
• For mounting on DIN-rail in accordance with DIN/EN 50 022
• 17.5 mm DIN-rail housing
• Combined AC and DC power supply
• LED indication for relay status and power supply ON
Type Selection
Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC
Mode of Operation
Function Op Function Io the second time period the periods until the power sup-
Delay on operate Interval on trigger open device resets and the first ply is interrupted.
The time period begins as The relay operates and the time period begins again.
soon as the trigger contact time period begins as soon Function Rb
is closed. as the trigger contact is Function Dr Symmetrical recycler,
At the end of the set delay opened. At the end of the Delay on release OFF-time period first
time the relay operates and set delay or when the power The relay operates as soon The time period begins as
does not release until the supply is disconnected the as the trigger contact is soon as the input contact is
trigger contact is closed relay releases. The relay closed. The time period closed. The relay is OFF
again or the power supply is operates again when the begins when the trigger con- during the set delay period,
disconnected. If the trigger trigger contact is opened tact is opened. The relay after this time it operates for
contact is closed before the again. If the trigger contact releases at the end of the the same time period. This
end of the delay time, the is opened before the end of set delay time or when the sequence continues with
device resets and a new the delay time the relay power supply is disconnect- equal OFF- and ON-time
time period starts. keeps ON and a new time ed. The relay operates again periods until the power sup-
period begins. when the input contact is ply is interrupted.
Function In closed again. If it is opened
Interval Function Id before the end of the delay Additional Load
The relay operates and the Double interval time the relay keeps ON, a It's possible to wire an addi-
time period begins as soon The relay operates and the new time period begins as tional load (i.e. a relay)
as the trigger contact is time period begins as soon soon as the contact is between pins Y1 and A2,
closed. The relay releases at as the trigger contact is closed again. driven by the trigger contact
the end of this period or closed. The relay releases at without damaging the
when the power supply is the end of this period or Function R device.
disconnected. The relay when the power supply is Symmetrical recycler, ON-
operates again when the disconnected. When the time period first Yellow LED working mode
trigger contact is closed trigger contact is opened The relay operates and the Timing: Slow blinking
again. If the trigger contact the relay operates again for time period begins as soon Relay ON: See operation
is closed before the end of the set delay period. If the as the input contact is diagrams
the delay time, the device trigger contact is opened closed. After the set delay
resets and a new time period before the end of the first period the relay releases for Incorrect knobs position:
starts. time period the second one the same time period. This Fast blinking
begins; if the trigger contact sequence continues with
is closed before the end of equal ON- and OFF-time
Wiring Diagram
DMB51
Operating Diagrams