0% found this document useful (0 votes)
39 views14 pages

Renke Water Quality Sensors

The document is a catalogue from Shandong Renke Control Technology Co., Ltd. detailing various types of water quality sensors including pH, conductivity, dissolved oxygen, turbidity, residual chlorine, and ORP sensors. Each sensor type is described with specifications, advantages, and suitable applications. The catalogue emphasizes the integrated design, high measurement accuracy, and versatility of the sensors for various industrial and environmental monitoring needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views14 pages

Renke Water Quality Sensors

The document is a catalogue from Shandong Renke Control Technology Co., Ltd. detailing various types of water quality sensors including pH, conductivity, dissolved oxygen, turbidity, residual chlorine, and ORP sensors. Each sensor type is described with specifications, advantages, and suitable applications. The catalogue emphasizes the integrated design, high measurement accuracy, and versatility of the sensors for various industrial and environmental monitoring needs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Water Quality Sensors Catalogue

Shandong Renke Control Technology Co.,Ltd.

Our water quality sensor types list:

1. Water ph sensor

2. Water conductivity sensor

3. Dissolved oxygen meter

4. Turbidity sensor

5. Residual chlorine sensor

6. ORP sensor

7. Ammonia nitrogen sensor

8. COD sensor

9. Blue-green algae sensor

10. Chlorophyll sensor

11. Water ion sensor

Shandong Renke Control Technology Co.,Ltd. 1


1. Water ph sensor

1.1 Integrated pH sensor

RS-PH-N01-3-EX is a integrated pH sensor for measuring the pH value (hydrogen ion


concentration index, pH) of a solution, with automatic temperature compensation
function. Automatic temperature compensation and manual temperature
compensation can be switched at will. This pH meter adopts an integrated design,
with a lighter and simpler structure and more convenient use. Waterproof grade IP68.
It is suitable for industrial sewage, domestic sewage, agriculture, aquaculture and
other scenes in non-corrosive weak acid and weak alkali environments.

Power supply: DC 7~30V


Power consumption: 0.3W
pH measure range: 0~14.00PH
Resolution: 0.01PH
pH measure error: ±0.15PH
Repeatability error: ±0.02PH
Temperature range: 0~60℃
Resolution: 0.1℃
Temperature measurement error: ±0.5℃
Withstand voltage: 0.6MPa
Line length: default 5m (can be customized)
Output: RS485
Advantages:
1. Integrated design, light and simple structure, easy to use.
2. Waterproof grade IP68.
3. The device uses a wide voltage power supply DC 7~30V

1.2 Industrial pH sensor

RS-PH-*-2-*-EX industrial pH sensor is our series of products for PH monitoring


indifferent environments. We have different probes corresponding to different use
environments. There are corresponding products for industrial sewage, domestic
sewage, agriculture, aquaculture, biological engineering, pharmaceuticals, mineral
suspension, flue gas desulfurization and other environments.

Shandong Renke Control Technology Co.,Ltd. 2


Power supply DC 10~30V
Power consumption: 0.6W (RS485), 1.2W
(Analog)
PH range: 0~14.00PH
Resolution: 0.01PH
PH measurement error: ±0.15PH
Repeatability error: ±0.02PH
Temperature measurement range: 0~80℃
Resolution: 0.1℃
Electrode applicable temperature: 0~80℃
Electrode withstand voltage: 0.6MPa
Electrode wire: 5m (10m, 15m, 20m for
optional)
Electrode use period: 6~12 months
Output mode: RS485/0-5V/0-10V/4-20mA
Advantages:
1. Complete variety, covering a wide range
2. High precision, high sensitivity and high stability
3. With automatic temperature compensation function
4. Obvious price advantage

2. Water conductivity sensor

2.1 Integrated conductivity sensor

RS-EC-N01-3-EX is a integrated conductivity sensor for measuring the conductivity of


solutions. It has an automatic temperature compensation function, which can
compensate the current temperature conductivity to the specified temperature. This
conductivity sensor adopts an integrated design, and the structure is lighter and
simpler. It can measure the values ​ ​ of conductivity, salinity and TDS at the same
time. It is widely used in places such as cross-section water quality, aquaculture,
sewage treatment, environmental protection, pharmaceuticals, food and tap water.

Shandong Renke Control Technology Co.,Ltd. 3


Power supply: DC 10~30V
Power consumption: 0.4W
EC range: K=1: 1~2000μS/cm (resolution 0.1μS/cm), K=10:
10~20000μS/cm (resolution 1μS/cm)
EC measure error: ±1%FS
Temperature measure range: -5~+80℃(resolution: 0.1℃)
Temperature measure error: ±0.5℃
Temperature compensation range: -5~+80℃
Temperature compensation coefficient: default 0.02
Salinity range: K=1: 0~1000ppm; K=10: 0~11476ppm
TDS range: K=1: 0~1100ppm; K=10: 0~13400ppm
Transmitter element temperature resistance -20~+80℃
Pressure resistance: 0.6MPa
Line length: default 5m (customizable)
Signal output: RS485

Advantages:
1. Waterproof grade IP68.
2. With salinity and TDS conversion function
3. ModBus communication address can be set and baud rate can be modified.
4. Wide voltage power supply, DC 10~30V is available.

2.2 Industrial conductivity sensor

RS-EC-*-2-*-EX industrial conductivity sensor is a device for measuring the


conductivity of a solution. It has an automatic temperature compensation function and
has two ranges: 1~2000µs/cm and 10~20000µs/cm. It is widely used in continuous
monitoring of the conductivity value of aqueous solutions such as section water quality,
aquaculture, sewage treatment, environmental protection, pharmaceuticals, food and
tap water.

Shandong Renke Control Technology Co.,Ltd. 4


Power supply DC 10~30V
Power consumption: 0.4W (RS485), 1W
(4-20mA/0-5V/0-10V)
EC measure range: K=0.01: 0.01~20μS/cm (resolution
0.001μS/cm), K=0.1: 0.1~200μS/cm (resolution
0.01μS/cm), K=1: 1~2000μS/cm (resolution 0.1μS/cm),
K=10: 10~20000μS/cm (resolution 1μS/cm)
EC measure error: ±1%FS
Temperature compensation range: -20~100℃
Temperature compensation coefficient: default 0.02
Salinity range: K=0.01: 0~10ppm, K=0.1: 0~100ppm, K=1:
0~1000ppm, K=10: 0~11476ppm
TDS range: K=0.01: 0~10ppm, K=0.1: 0~100ppm, K=1:
0~1100ppm, K=10: 0~13400ppm
Electrode line length: default 5m (customizable)
Advantages:
1. With automatic temperature compensation function.
2. High precision, high sensitivity and high stability
3. It can monitor EC and temperature at the same time, and one device can monitor multiple
elements
4. Obvious price advantage

3. Dissolved oxygen meter

RS-LDO*-*-EX Dissolved oxygen meter is a device for measuring the concentration of


dissolved oxygen in a solution. It adopts the principle of fluorescence measurement,
does not consume oxygen, and does not require electrolyte. It is divided into two
types: sea water and fresh water. It is suitable for scenarios where maintenance is
inconvenient and requires long-term monitoring, such as industrial water quality
monitoring, aquaculture monitoring, and river and lake seawater quality parameter
monitoring.

Shandong Renke Control Technology Co.,Ltd. 5


Power supply: DC 10~30V
Power consumption: 0.2W (RS485), ≤0.8W
(4-20mA/0-5V/0-10V)
Measurement principle: fluorescence method
DO range: 0~20mg/L (0~200% saturation)
Measurement error: ±3%FS; ±0.5℃ (25℃)
Resolution: 0.01mg/L; 0.1%; 0.1℃
Response time: ≤60s
Equipment working conditions: 0~40℃
Waterproof grade: IP68
Pressure resistance: 0.6MPa
Electrode line length: default 5m
Casing material: corrosion-resistant
plastic/stainless steel/corrosion-resistant plastic
Advantages:
1. Built-in temperature transmitter with automatic temperature compensation function
2. Using German imported membrane head, high precision, high sensitivity and high stability
3. There is no need to replace the diaphragm regularly, frequent calibration problems, and
long-term maintenance-free (compared to the extremely popular method)
4. Simultaneously monitor dissolved oxygen, saturation, and temperature,and one device
measures multiple factors.

4. Turbidity sensor

The RS-ZD-*-EX turbidity sensor is designed and manufactured using the principle of
laser scattering turbidity measurement. The laser scattering method can overcome
the shortcomings of traditional classical measurement methods that cannot be
continuously measured online. The laser scattering method is stable in measurement
and is not subject to magnetic field interference. It has been widely used. It is suitable
for agricultural water, industrial water, sewage discharge in mining area, aquaculture,
surface water, domestic sewage treatment terminal and other places.

Shandong Renke Control Technology Co.,Ltd. 6


Power supply: DC 10~30V
Power consumption: 0.2W (RS485), ≤0.8W
(4~20mA/0~5V/0~10V)
Turbidity range: 0.00~50.00NTU, 0.0~200.0NTU,
0.0~1000.0NTU, 0~4000NTU
Measure error: ±5%FS (25℃); ±0.5℃
Resolution: 0.01NTU (0.00~50.00NTU), 0.1NTU
(0.0~200.0NTU), 0.1NTU (0.0~1000.0NTU), 1NTU
(0~4000NTU)
Response time: ≤30sec
Working conditions: 0~40℃
Working principle 90° light scattering method
Electrode line length: default 5m
Casing material: corrosion-resistant plastic
Advantages:
1. 90° angle scattered light principle, built-in temperature sensor optical fiber structure, strong
resistance to external light interference.
2. Infrared LED light source, high stability, convenient, fast, stable and easy to maintain.
3. Simultaneous monitoring of turbidity and temperature, one device
measures multiple elements.
4. No probe consumption, high sensitivity, low detection limit, long life,
continuous online monitoring.

5. Residual chlorine sensor

5.1 Integrated residual chlorine sensor

RS-CL-N01-3-EX is a device for measuring residual chlorine concentration in water


(hypochlorous acid, hypochlorite concentration). The three-electrode system has the
advantages of high measurement accuracy, long working life and no need for frequent
calibration. It is suitable for automatic dosing of circulating water, chlorination control
of swimming pools, and accurate measurement of residual chlorine content in
aqueous solutions in drinking water treatment plants, drinking water distribution
networks, swimming pools, and hospital wastewater.

Shandong Renke Control Technology Co.,Ltd. 7


Power supply: DC 7~30V
Power consumption: 0.19W
Measure range: 0-2mg/L, 0-10mg/L, 0-20mg/L
Resolution: 0.01mg/L
Measure error: ±5%FS
Repeatability error: ±0.05mg/L
Response time: <30s
Transmitter withstand voltage: 0.6MPa
Electrode line length: default 5m (customizable)
Signal output: RS485

Advantages:
1. The integrated design directly outputs 485 signals to eliminate signal interference.
2. 3/4 upper and lower mounting thread design for easy installation.
3. Using advanced non-membrane constant voltage sensor, no need to replace diaphragm
and reagent.
4. ModBus communication address can be set and baud rate can be modified.
5. Wide voltage power supply DC 7~30V is available.

5.2 Industrial residual chlorine sensor

RS-CL-*-2-20-*-EX chlorine sensor uses a diaphragm polarographic sensor. The


residual chlorine in the measured liquid diffuses to the cathode through the diaphragm.
Applying an appropriate polarization voltage between the cathode and the anode can
reduce the residual chlorine in the measured solution. These chemical reactions
produce a current proportional to the residual chlorine in the measured solution. It is
suitable for online monitoring of residual chlorine concentration in medicine,
environmental protection, tap water monitoring, drinking water, and industrial process
water disinfection and sterilization.
Power supply: DC 10~30V
Power consumption: 0.19W (RS485), 0.67W
(4-20mA/0-5V/0-10V)
Measure range: 0-2mg/L, 0-10mg/L, 0-20mg/L
Resolution 0.01mg/L
Measure error: 5% or 0.05mg/L
Repeatability error: ±0.05mg/L
Response time: <30s
Electrode applicable temperature: 0~50℃
Electrode withstand voltage: 0.6MPa
Wire length: 5m by default (customizable)

Shandong Renke Control Technology Co.,Ltd. 8


Advantages:
1. The product does not need to be calibrated at one time.
2. The measurement principle of the constant voltage method does not
consume reagents and replace the diaphragm, and the maintenance is
simple.
3. By default, residual chlorine and temperature are monitored at the same time, and one
device measures multiple elements.

6. ORP sensor

6.1 Integrated ORP sensor

The RS-ORP-N01-3-EX ORP sensor can measure the redox potential of a solution.
The ORP composite electrode is made of high-purity platinum and has strong
resistance to acid, alkali and oxidation. This ORP sensor adopts an integrated design,
with a lighter and simpler structure, high measurement accuracy and temperature
measurement function. It is suitable for industrial wastewater containing cyanide,
chromium, etc., rivers, lakes and aquaculture industries.

Power supply: DC 7~30V


Power consumption: 0.3W
ORP range: -1999~1999mV
Resolution: 1mV
ORP measure error: ≤±5mV
Temperature range: 0~60℃; Resolution: 0.1℃
Temperature measure error: ±0.5℃
Working conditions: 0~60℃
Withstand voltage: 0.6MPa
Line length: 5m by default (customizable)
Signal output: RS485

Advantages:
1. Integrated design, output 485 signal, easy to use, waterproof level IP68.
2. High measurement accuracy, fast response, good stability.
3. ModBus communication address can be set, baud rate can be modified.
4. Wide voltage power supply DC 7~30V is available.

6.2 Industrial ORP sensor

The RS-ORP -*-2-*-EX is used to measure the oxidation-reduction potential of a

Shandong Renke Control Technology Co.,Ltd. 9


solution. The ORP value is an important indicator of water quality. It is generally
integrated with other water quality indicators to reflect the ecological environment in
the aquarium system, but cannot independently reflect water quality. Good or bad.
Suitable for on-line monitoring of the oxidation-reduction potential of agricultural water,
aquaculture, surface water, cyanide-containing, chromium-containing wastewater, etc.

Power supply: DC 10~30V


Power consumption: 0.6W (RS485), 1.2W
(4~20mA/0~5V/0~10V)
ORP measurement range: -1999~1999mV
Resolution: 1mV
ORP measurement error: ±10mV
Transmitter temperature resistance:
-20℃~+80℃, 0%RH~95%RH (non-condensing)
Electrode applicable temperature: 0~80℃
Electrode withstand voltage: 0.6MPa
Electrode line length: default 5m (customizable)
Signal output: RS485/4-20mA/0-5V/0-10V

Advantages:
1. Made of high-purity platinum, it has strong anti-acid and alkali ability and anti-oxidation ability
2. With automatic compensation function
3. High precision, high sensitivity and high stability

7. Ammonia nitrogen sensor

The RS-NHN-*-3/4/5-*-EX ammonia nitrogen sensor is a device that measures the


concentration of ammonia nitrogen in water (combined nitrogen in the form of free
ammonia (NH3) and ammonium ions (NH4+)). It can automatically perform
temperature and pH compensation to suit measurements in various environments. It
can be directly installed, which is more economical, environmentally friendly,
convenient and fast than traditional ammonia nitrogen analyzers.

Shandong Renke Control Technology Co.,Ltd. 10


Power supply: DC 10~30V
Power consumption: 0.3W (RS485), 0.9W
(4~20mA/0~5V/0~10V)
Ammonia nitrogen range: 0-10mg/L (resolution
0.01mg/L), 0-100mg/L (resolution 0.01mg/L),
0-1000mg/L (resolution 0.1mg/L)
PH measure range: 0-14PH
Temperature measure range: -20-80℃
Ammonia nitrogen measure error: ±3%FS
PH measure error: ±0.15PH
Temperature measure error: ±0.3℃
Repeatability error: 1%
Response time: <30s
Applicable temperature: 0~50℃
Equipment withstand voltage: 0.2MPa
Line length: 5m by default (customizable)
Advantages:
1. With automatic temperature compensation, the accuracy is higher and the applicable
environment is wider.
2. Online equipment, no reagents are required, no pollution, more economical and
environmentally friendly.
3. One-piece housing, 3/4 thread design, easy to install.
4. Wide voltage power supply DC 10~30V is available.

8. COD sensor

RS-COD-*-2-EX is a device for measuring the chemical oxygen demand (COD) of a


solution. It uses the ultraviolet absorption method and does not require chemical
reagents. The internal integrated self-cleaning system effectively prevents biological
attachment. The COD sensor has an automatic temperature compensation function
and uses a modulated light signal to reduce visible light interference. It has a turbidity
measurement function to effectively compensate for the impact of turbidity on COD
measurement. It can be widely used in water treatment, aquaculture, environmental
monitoring and other industries.

Shandong Renke Control Technology Co.,Ltd. 11


Power supply DC 12~30V
Measuring principle: dual-wavelength ultraviolet
absorption method
Measuring range: 0~500mg/L equiv.KHP
Measuring error: ±5%FS equiv.KHP (25℃)
Resolution: 0.1mg/L
Repeatability ±1%FS equiv.KHP (25℃)
Response time: ≤20sec
Flow rate: <3m/s
Withstand pressure: <0.1MPa
Electrode line length: default 5m (customizable)
Material: corrosion-resistant plastic/stainless steel
Calibration frequency: 3 months
Self-cleaning system life: 18 months
Signal output: RS485/4-20mA/0-5V/0-10V
Advantages:
1. Use modulated light signals to reduce visible light interference.
2. Dual optical path measurement to compensate for the impact of turbidity on COD
measurement.
3. Internally integrated self-cleaning system to effectively prevent biological attachment.
4. The equipment uses a wide voltage power supply, DC 12~30V is available.

9. Blue-green algae sensor

RS-BA-*-2-EX is a device for measuring the concentration of blue-green algae in


water. It uses the principle of fluorescence, which is more efficient and faster than the
traditional manual counting method, and can be monitored online in real time. The
internal filter algorithm is added to have strong resistance to external light interference.
The built-in temperature transmitter can automatically compensate for the
temperature.

Power supply DC 7~30V


Power consumption 0.4W
Measurement range: 0~300000 cells/ml
Temperature error: ±0.5℃
Resolution: 1cells/ml, temperature: 0.1℃
Linearity: R²>0.999
Working conditions: 0~40℃
Electrode line length: default 5m
Casing material: corrosion-resistant plastic
Withstand pressure: <0.6MPa
Signal output: RS485

Shandong Renke Control Technology Co.,Ltd. 12


Advantages:
1. Waterproof grade IP68.
2. Light filtering algorithm, strong resistance to external light interference, automatic
temperature compensation, suitable for online long-term detection environment.
3. ModBus communication address can be set, baud rate can be modified.
4. Wide voltage power supply, DC 7~30V is available.

10. Chlorophyll sensor

RS-CH-*-2-EX is a device for measuring chlorophyll concentration in water. It adopts


the principle of fluorescence and uses the design method of optical fiber transmission
light path. The internal filter algorithm is added to have strong resistance to external
light interference. The built-in temperature transmitter can automatically compensate
for temperature. It can be used in rivers, lakes, ponds, marine surveys, aquaculture,
drinking water sources and other places.

Power supply: DC 7~30V


Power consumption 0.4W
Measurement range: 0~400μg/L; 0~100RFU
Measurement error: ±5%FS (25℃); ±0.5℃
Resolution: 0.1μg/L, 0.1RFU, 0.1℃
(temperature)
Response time: ≤30s
Working conditions: 0~40℃
Waterproof grade: IP68
Electrode cable length: default 5m
Casing material: corrosion-resistant plastic
Signal output: RS485

Advantages:
1. Waterproof grade IP68.
2. Light filtering algorithm, strong resistance to external light interference, automatic
temperature compensation, suitable for online long-term detection environment.
3. ModBus communication address can be set, baud rate can be modified.
4. Wide voltage power supply, DC 7~30V is available.

11. Water ion sensor

Potassium ion: RS-LK-*-2-EX


Mainly used in mineral water, drinking water, surface water, sea water, boiler feed
water, tea, honey, feed, milk powder and other agricultural products, saliva, serum,

Shandong Renke Control Technology Co.,Ltd. 13


urine and other biological samples, and the determination of potassium ions in
ceramic raw materials.

Nitrate ion: RS-LNO3--*-2-EX


Mainly used in the determination of nitrate ions in solid leachate, rainfall and surface
water, and pickled products.

Chloride ion: RS-LCL-*-2-EX


Mainly used in mineral water, drinking water, surface water, sea water, boiler feed
water, tea, honey, feed, milk powder and other agricultural products, saliva, serum,
urine and other biological samples, as well as the determination of chloride content in
soil extract.

Calcium ion: RS-LCA-*-2-EX


Mainly used in mineral water, drinking water, surface water, sea water, boiler feed
water, tea, honey, feed, milk powder and other agricultural products, saliva, serum,
urine and other biological samples, and the determination of calcium ions in ceramic
raw materials.

Ammonium ion: RS-LNH-*-2-EX


Mainly used in the measurement of ammonium ions in boiler feed water, surface
water and fertilizers.

Nitrite ion: RS-LNO2-*-2-EX


Mainly used in the determination of nitrate ions in solid extracts and pickled products.

Magnesium ion: RS-LMG-*-2-EX


Mainly used in the monitoring of magnesium ions in mineral water, drinking water,
surface water and sea water.

Shandong Renke Control Technology Co.,Ltd. 14