Voltmeter

Instruction Manual

ADDRESS: İkitelli OSB Mah. Environment 14th Block Street. Telas Blok Exterior Door No: 1
Floor: 1-2 Başakşehir/Istanbul

Phone: +90 212 438 80 24 Fax: +90 212 438 80 25 [email protected]

Version 19-2

1
CONTENTS
PROPER USE AND SAFETY REQUIREMENTS ............................. 1
1. INTRODUCTION ............................................................................. 2
1.1 General Features........................................................................... 2
1.2 Technical Features ....................................................................... 2
1.3 Dimensions of the Device ............................................................ 3
1.4 Measurable Line Parameters ........................................................ 3
1.5 Buttons and Functions .................................................................. 3
1.6 Connection Diagram .................................................................... 4
2.INSTALLATION ............................................................................... 5
2.1 Device Installation ....................................................................... 5
2.2 Installation Menu ......................................................................... 5
2.3 About LEDs ................................................................................. 5
3. MAIN MENU AND SUB-MENUS .................................................. 6
3.1 Line Voltage Menu ...................................................................... 6
3.2 Measurement Voltage Menu ........................................................ 6
3.3 Cnt Menu ...................................................................................... 6
3.3.1 Reverse Menu ........................................................................ 7
3.3.2 Type Menu ............................................................................. 7
3.3.3 SetA Menu ............................................................................. 7
3.3.4 SetB Menu ............................................................................. 8
3.3.5 Relay Control Time Menu ..................................................... 8
3.4 Default Setting Menu ................................................................... 8
3.5 Reset Menu................................................................................... 8
4. LANGUAGE MENU ........................................................................ 9
5. SELECTION TABLE........................................................................ 9
Voltmeter Instruction Manual

PROPER USE AND SAFETY REQUIREMENTS

Cut all the power when connecting and disconnecting the device
to a panel.

Do not clean the device with a solvent or similar material. Only


use a dry cloth.

Please do not intervene to the device when a technical problem is


encountered and get in contact with a technical service within the
shortest time.

If the warnings are not taken into account, our company or the
authorized dealer shall not be held responsible for the negative
consequences.

Do not dispose in the trash, the device must be delivered to the


collection centers (electronic device recycling centers). It should
be recycled or disposed of without harming human health and
environment.

The installation, assembly, activation and operation of the device


should be done and used by only expert professionals and in
accordance with safety regulations and instructions.

1
Voltmeter Instruction Manual

1. INTRODUCTION
1.1 General Features
Voltmeter measures and calculate the voltage value that belongs to a single phase
as True-RMS.

The voltage transformer settings can be made via the menu.

In the versions with the output feature, the relay is controlled according to the
voltage value ranges that are set through the menu.

Voltmeter does not require a separate supply input with its new supply design.
The device can operate if there is power (85-265 Volt) in the voltage phase (L1).

1.2 Technical Features


 Microprocessor based.
 The operating ambient temperature of the device must be between -10 °C and
+55 °C.
 The power consumption of the measuring inputs is less than 1 VA.
 It has IP20 protection class.
 The voltage measurement range is 85-265 V AC (45-65 Hz).
 Its operating frequency is 45-65 Hz.
 The measurement precision is 1%.
 The device can make the single-phase voltage measurement.
 The power consumption in the version with relay output is 4.0-8.5 VA and 3.0-
7.0 VA in the normal version.
 It can optionally have one 5A relay output.
 It has one 4-digit 7-segment display.
 The dimensions of the device are (width-length-depth) 97.5x97.5x50.5 mm.
 It operates under 85-265 V AC voltage.
 It has control output, menu and k (x1000) LEDs.

2
Voltmeter Instruction Manual

1.3 Dimensions of the Device

Figure 1.1

1.4 Measurable Line Parameters


Voltmeter can make single phase voltage measurement.

1.5 Buttons and Functions

PRG button enables to access the menu when on operation screen.


It fulfills selection function when scrolling through the menu.

It enables to return to the previous process and exit from the menu.

Up arrow button enables to change parameters displaying on operation


screen and stroll between the menus.

Down arrow button enables to change parameters displaying on


operation screen and stroll between the menus.

3
Voltmeter Instruction Manual

1.6 Connection Diagram

Figure 1.2

4
Voltmeter Instruction Manual

2.INSTALLATION
2.1 Device Installation
Make the connections of the voltage input according to the Figure 1.2.

Give energy to the device after checking and verifying the connections.

2.2 Installation Menu


After giving energy to your device, the voltage measurement
value is shown as in Figure 2.1
Figure 2.1

2.3 LED Descriptions


There are two LEDs (three in the
devices with output option) on your
device.

The menu LED will be on when


entering the menu.

There is a K(x1000) LED on the left


bottom of the device screen.

NOTE: If the related LED is on, the


unit of the value displaying on the
screen is in Kilo.

Figure 2.2

5
Voltmeter Instruction Manual

3. MAIN MENU AND SUB-MENUS

To enter menu, press the PRG button in the front panel of the device. The up and
down buttons are used to scroll between menus in the device. There are five main
menus in total. Press the PRG button to enter the wanted menu

NOTE: When scrolling through the menu, holding down to the up button makes
the transition fast and the menu come to the top. Moreover, holding down to the
down button makes the transition fast and the menu comes to the bottom

3.1 Line Voltage Menu


In “Line” menu, the line voltage value is set among the values that are seen in
the table below.

190 380 400 480 500 525 550 650 690

LINE
725 900 1000 6300 10500 11000 14000 15800 28500
VOLTAGE

29250 30000 30750 31500

3.2 Measurement Voltage Menu


In “Sens.” menu, the measurement voltage value is set among the values that are
seen in the following table.

MEASUREMENT
100 110 115 120 190 380 400 480
VOLTAGE

3.3 Cnt Menu


The settings related to the output control are made in “Cnt” menu. In this menu,
there are eight sub-menus as “type”, “Inur.”,
“set.a”,“set.b”,“t.on”,“t.off”, “t.rdy” and “rSt.”.

6
Voltmeter Instruction Manual

3.3.1 Reverse Menu


If “Yes” is selected in “Inur.” menu, the relay outputs are set reverse to the
present status.

3.3.2 Type Menu


By entering “type” menu, the parameter to produce output value will be
selected.

“Uolt” → The output controls are made via the voltage parameter.
“None” → No parameter is selected for output control.

3.3.3 SetA Menu


In “Set.a” menu, a value is given if “Uolt” is selected in the “type”
menu before.

The A point in Figure 3.1 indicates the required quantity (0 – 1000) for the output
to be “On”. If the voltage value is bigger than the value that is determined in the
“Set.a” menu, the voltmeter output becomes “On” and “Control Output” LED
becomes on. If the voltage value is smaller than “Set.b” value, the voltmeter
output becomes “Off” and “Control Output” LED becomes off.

NOTE: The entered values are in Volt (V).

A and B points in Figure 3.1 are the


voltage points that are read from the
system.

If the voltage value is bigger than A


value, the output that is related to the
voltmeter becomes ON. If the
measured value is smaller than B
value, the output that is related to the
voltmeter becomes OFF.
Figure 3.1

7
Voltmeter Instruction Manual

3.3.4 SetB Menu


In “Set.b ” menu, a value is given if “Uolt” is selected in the “type”
menu before.

It indicates the quantity (0-1000) of B point in the Figure 3. If the voltage value
is smaller than the value of point B that is determined in “Set.b” menu, the
voltmeter output becomes “Off” and “Control Output” LED becomes off.

NOTE: The entered values are in Volt (V).

3.3.5 Relay Control Time Menu


In “t.on” menu, in the case of the electrical values exceed the “Set.a” value ,the
time to wait for pulling the relay is determined.

In “t.off” menu, in the case of the electrical values drop below the “Set.b”
values, the time to wait for releasing the relay is determined.

In “t.rdy” menu, the time between the relay pull and release processes are
determined. A period of time is waited depends on charge and discharge states of
the capacitor and then the relay is pulled or released.

NOTE: The main aim to determine time is to prevent the relay to be pulled and
released frequently in case of sudden increasing and decreasing of values.

3.4 Default Setting Menu


All the settings except for the current transformer ratio are reset in the “D.Set..”
menu. (return to default values). Press the PRG button to enter the menu. There
appear two options as “Yes” and “No”. If “Yes” option is selected with the PRG
button, the device will return to the factory default settings.

3.5 Reset Menu


The “Rst” (Reset) menu brings the device back to its state before the installation.
All the saved information and parameters are reset with this menu. It also provides
to use the same device in different panels. Press the PRG button to enter the “Rst”
menu. There appear two options as “Yes” and “NO”. If the “Yes” is selected with
the PRG button, the device will be reset.

NOTE: The voltage transformer ratio does not return to the factory default
settings.
8
Voltmeter Instruction Manual

4. LANGUAGE MENU

The “lng” menu has two language options “tur” Turkish, and “Eng” English.
When the language is changed, the menu and units will change.