0% found this document useful (0 votes)
44 views5 pages

Ul Product

The document outlines fire-resistance ratings for wide flange steel columns as per ANSI/UL 1709, detailing specifications for various steel sizes and required thicknesses of protective coatings. It emphasizes the importance of consulting authorities having jurisdiction for installation requirements and highlights that only products bearing UL's Mark are considered certified. Additionally, it provides guidelines for the application of mastic and intumescent coatings, as well as the use of carbon fiber mesh for enhanced fire protection.

Uploaded by

aloke2mondal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views5 pages

Ul Product

The document outlines fire-resistance ratings for wide flange steel columns as per ANSI/UL 1709, detailing specifications for various steel sizes and required thicknesses of protective coatings. It emphasizes the importance of consulting authorities having jurisdiction for installation requirements and highlights that only products bearing UL's Mark are considered certified. Additionally, it provides guidelines for the application of mastic and intumescent coatings, as well as the use of carbon fiber mesh for enhanced fire protection.

Uploaded by

aloke2mondal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

BYBU.XR620 - Fire-resistance Ratings - ANSI/UL 1709 | UL Product iQ https://iq.ulprospector.com/en/profile?

e=17462

Design/System/Construction/Assembly Usage Disclaimer


Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation
and use of UL Certified products, equipment, system, devices, and materials.
Authorities Having Jurisdiction should be consulted before construction.
Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for
compliance with applicable requirements. The published information cannot always address every construction nuance
encountered in the field.
When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the
product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide
Information for each product category and each group of assemblies. The Guide Information includes specifics concerning
alternate materials and alternate methods of construction.
Only products which bear UL's Mark are considered Certified.

See General Information for Fire-resistance Ratings - ANSI/UL 1709

Design No. XR620


September 30, 2020

Ratings - 1, 1-1/2, 2, 2-1/2, 3 Hr (See Table)


* Indicates such products shall bear the UL or cUL Certification Mark for
jurisdictions employing the UL or cUL Certification (such as Canada), respectively.

1 of 5 1/12/2021, 9:50 AM
BYBU.XR620 - Fire-resistance Ratings - ANSI/UL 1709 | UL Product iQ https://iq.ulprospector.com/en/profile?e=17462

1. Steel Column — Wide flange steel columns having a W/D ratio of .84 to 3.55 and a maximum flange width of 16-1/8 in.
See table in Item 2. Table not intended to be all inclusive.

2. Mastic and Intumescent Coating — Spray applied in one or more coats to the thickness shown in the table below.
Column surfaces which must be free of dirt, loose scale and oil. Column surfaces to be primed. Primer thickness
approximately 0.0015 in. Coating lightly rolled after final coat with a paint roller.
CARBOLINE CO — Types Thermo-lag 3000-SP, Thermo-Lag 3000-P, Thermo-Lag 3000-SA, Thermo-Lag 3000-A and Thermo-Lag
3000-FC INVESTIGATED FOR UL 2431 CLASSIFICATION CATEGORY I- A and EXTERIOR ENVIRONMENTAL PURPOSE.

Wide Flange Steel


Specifications Time (min)
60 Thkns 90 Thkns 120 Thkns 150 Thkns 180 Thkns
Required, Required, Required, Required, Required,
Steel Size W/D HP/A In. In. In. In. In.

W12X279 3.48 39 0.12 0.13 0.19 0.25 0.35

W14X311 3.26 41 0.12 0.14 0.20 0.26 0.37

W12X252 3.19 42 0.12 0.14 0.20 0.26 0.37

W14X283 3.00 45 0.12 0.14 0.21 0.27 0.39

W12X230 2.94 46 0.12 0.14 0.21 0.27 0.39

W14X257 2.75 49 0.12 0.15 0.22 0.28 0.41

2 of 5 1/12/2021, 9:50 AM
BYBU.XR620 - Fire-resistance Ratings - ANSI/UL 1709 | UL Product iQ https://iq.ulprospector.com/en/profile?e=17462

W12X210 2.72 49 0.12 0.15 0.22 0.28 0.41

W14X233 2.52 53 0.12 0.16 0.22 0.29 0.42

W14X228 2.44 55 0.12 0.16 0.23 0.30 0.43

W14X211 2.30 58 0.12 0.16 0.23 0.31 0.44

W12X170 2.26 59 0.12 0.16 0.24 0.31 0.44

W36X300 2.19 61 0.12 0.16 0.24 0.31 0.45

W14X193 2.12 63 0.12 0.17 0.24 0.32 0.45

W36X280 2.07 65 0.12 0.17 0.24 0.32 0.46

W12X152 2.04 66 0.12 0.17 0.25 0.32 0.46

W14X176 1.95 69 0.12 0.17 0.25 0.33 0.47

W36X260 1.92 70 0.12 0.17 0.25 0.33 0.47

W33X241 1.88 71 0.12 0.18 0.25 0.33 0.47

W12X136 1.84 73 0.12 0.18 0.26 0.33 0.48

W10X112 1.81 74 0.12 0.18 0.26 0.34 0.48

W14X159 1.77 75 0.12 0.18 0.26 0.34 0.48

W30X211 1.76 76 0.12 0.18 0.26 0.34 0.48

W33X221 1.72 78 0.12 0.18 0.26 0.34 0.49

W36X230 1.71 78 0.12 0.18 0.26 0.34 0.49

W10X100 1.63 82 0.12 0.18 0.27 0.35 0.49

W21X147 1.60 84 0.12 0.19 0.27 0.35 0.49

W33X201 1.58 85 0.12 0.19 0.27 0.35 0.50

W14X132 1.54 87 0.12 0.19 0.27 0.36 0.50

W24X146 1.48 91 0.12 0.19 0.28 0.36 0.50

W18X119 1.47 91 0.12 0.19 0.28 0.36 0.50

W12X106 1.47 91 0.12 0.19 0.28 0.36 0.50

W10X88 1.45 92 0.12 0.19 0.28 0.36 N/A

W14X120 1.40 95 0.12 0.19 0.28 0.37 N/A

W33X152 1.37 97 0.12 0.20 0.28 0.37 N/A

W8X67 1.36 98 0.12 0.20 0.28 0.37 N/A

W21X122 1.34 100 0.12 0.20 0.28 0.37 N/A

3 of 5 1/12/2021, 9:50 AM
BYBU.XR620 - Fire-resistance Ratings - ANSI/UL 1709 | UL Product iQ https://iq.ulprospector.com/en/profile?e=17462

W12X96 1.34 100 0.12 0.20 0.28 0.37 N/A

W18X106 1.32 101 0.12 0.20 0.29 0.37 N/A

W36X150 1.28 104 0.12 0.20 0.29 0.38 N/A

W10X77 1.28 104 0.12 0.20 0.29 0.38 N/A

W21X93 1.24 108 0.12 0.20 0.29 0.38 N/A

W21X111 1.23 109 0.12 0.20 0.29 0.38 N/A

W14X82 1.22 109 0.12 0.20 0.29 0.38 N/A

W12X87 1.22 110 0.12 0.20 0.29 0.38 N/A

W24X117 1.20 112 0.12 0.20 0.29 0.38 N/A

W8X58 1.19 112 0.12 0.20 0.29 0.38 N/A

W14X99 1.17 114 0.12 0.20 0.30 0.39 N/A

W36X135 1.16 115 0.12 0.20 0.30 0.39 N/A

W10X68 1.14 117 0.12 0.21 0.30 0.39 N/A

W21X101 1.12 119 0.12 0.21 0.30 0.39 N/A

W12X79 1.11 120 0.12 0.21 0.30 0.39 N/A

W18X86 1.08 123 0.12 0.21 0.30 0.39 N/A

W18X71 1.08 124 0.12 0.21 0.30 0.39 N/A

W14X90 1.07 125 0.12 0.21 0.30 0.40 N/A

W16X77 1.06 126 0.12 0.21 0.30 0.40 N/A

W27X94 1.02 130 0.12 0.21 0.31 0.40 N/A

W14X68 1.03 130 0.12 0.21 0.31 0.40 N/A

W10X60 1.02 131 0.12 0.21 0.31 0.40 N/A

W30X99 1.00 134 0.12 0.21 0.31 0.40 N/A

W8X48 1.00 134 0.12 0.21 0.31 0.40 N/A

W21X73 0.99 135 0.12 0.21 0.31 0.40 N/A

W18X76 0.96 139 0.12 0.21 0.31 0.41 N/A

W16X57 0.95 140 0.12 0.21 0.31 0.41 N/A

W16X67 0.93 144 0.12 0.21 0.31 0.41 N/A

W12X65 0.92 145 0.12 0.21 0.31 0.41 N/A

W10X54 0.92 145 0.12 0.21 0.31 0.41 N/A

4 of 5 1/12/2021, 9:50 AM
BYBU.XR620 - Fire-resistance Ratings - ANSI/UL 1709 | UL Product iQ https://iq.ulprospector.com/en/profile?e=17462

W12X50 0.91 147 0.12 0.21 0.31 0.41 N/A

W10X45 0.89 151 0.12 0.21 0.31 0.41 N/A

W18X55 0.85 158 0.12 0.21 0.31 0.41 N/A

W12X53 0.85 157 0.12 0.21 0.31 0.41 N/A

W16X50 0.84 159 0.12 0.21 0.31 0.41 N/A

W10X49 0.84 159 0.12 0.21 0.31 0.41 N/A

For product Alternate Limiting Temperature Table click here: XR620-1

3a. Carbon Fiber Mesh — Nom 3/16 in. by 3/16 in. 3.50 oz/sq yd carbon fiber mesh to cover the entire flange face, flange
tips, and 1/2 the depth of the inner flange. The flange mesh shall be applied in a horizontal orientation with adjacent
horizontal pieces of mesh overlapped a minimum of 1 in. The mesh shall be applied to the web in a vertical orientation and
shall span the width and length of the web. The depth at which the reinforcing mesh is placed shall be in accordance with
the table below:
Thickness of Protection Depth of Placement of
Material (in.) Reinforcing Mesh (in.)

0.12 - 0.24 Approximate mid point of

0.24 and greater 0.12

3b. Steel Mesh — (As an alternate to item 3a) Nom. 19 ga.welded wire 1/2 in by 1/2 in. by 0.08 in. dia.(12.7 mm. by
12.7mm. by 2 mm. Dia) galvanized mesh to cover the entire flange face, flange tips, and 1/2 the depth of the inner flange.
The flange mesh shall be applied in a horizontal orientation with adjacent horizontal pieces of mesh overlapped a
minimum of 1 in. The mesh shall be applied to the web in a vertical orientation and shall span the width and length of the
web. For thicknesses less than 0.24 in. (6 mm.) the mesh shall be located at the steel surface. For thicknesses greater than
0.24 in. (6 mm.) the mesh shall be located at 0.12 in. (3mm) from the steel surface. Optional, Nominal 12 ga. steel pins may
be secured to the surface of the steel to aid in the placement of the mesh.

4. Top Coat* — Type Carbomastic 94 MC topcoat applied over mastic and intumescent coating (Item 2) at 0.005 to 0.012
in. thicknesses.

* Indicates such products shall bear the UL or cUL Certification Mark for
jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
Last Updated on 2020-09-30

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-
Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice
in the following format: "© 2021 UL LLC"

5 of 5 1/12/2021, 9:50 AM

You might also like