International Limited: Certificate of Visual Examination

This document provides certificates of visual examination for various lifting equipment on the Pacific Bora drilling rig. It summarizes the inspection of 10 items between December 2011 and January 2012, finding no defects in the wire rope slings, shackles and other equipment. The inspector was Fredrick Mina, qualified through LEEA and SNT Level II testing, and re-inspection of the equipment is required between June and July 2012.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views434 pages

International Limited: Certificate of Visual Examination

This document provides certificates of visual examination for various lifting equipment on the Pacific Bora drilling rig. It summarizes the inspection of 10 items between December 2011 and January 2012, finding no defects in the wire rope slings, shackles and other equipment. The inspector was Fredrick Mina, qualified through LEEA and SNT Level II testing, and re-inspection of the equipment is required between June and July 2012.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 434

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2005 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 4187-20 1set 16mm X 6ft X 2 legged c/w ORing and thimble eye at one end, other end thimble eye. N/A
2.8t @ 0 0-45

N/A

N/A

22-07-12

LOCATION: SACK STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2006 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 4187-19 1set 16mm X 6ft X 2 legged c/w ORing and thimble eye at one end, other end thimble eye. N/A
2.8t @ 0 0-45

N/A

N/A

22-07-12

LOCATION: SACK STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2007 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-2 1pc 1 X 10ft X Single leg sling c/w soft eye at both ends. N/A 8t N/A N/A 22-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2008 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5142-2 1set 20mm X 4ft X 4 legged c/w Quad master link assembly with ferrule secured thimble eye at all ends. N/A 10.5t @ 0 0-45 N/A N/A 23-07-12

LOCATION: REMOVABLE COMPLETION BOP DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2009 Identification Number Qty

29/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING MCRM 237222MF 1set 19mm X 7ft X 4 legged c/w Quad master link assembly with ferrule secured thimble eye at all ends. N/A 9.6t @ 0 0-45 N/A N/A 28-07-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2010 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5122-8 1pc 20mm X 5ft X Single leg sling c/w soft eye at both ends. N/A 5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2011 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5122-4 1pc 20mm X 5ft X Single leg sling c/w soft eye at both ends. N/A 5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2012 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 964343-0-5-2 1pc


5

/8 X 11ft X Single leg sling c/w soft eye at both ends.

N/A

7.6t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2013 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-1 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends. N/A 6t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2014 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-44 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends.

N/A

1.4t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2015 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-12 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends.

N/A

1.4t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2016 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5112-2 1pc


3

/8 X 2ft X Single leg sling c/w soft eye at both ends.

N/A

1.2t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2017 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-6 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends.

N/A

2.5t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2018 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q1393-7 1pc 16mm X 9.20mtrs X Single leg sling c/w soft eye at both ends. N/A 3t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2019 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-13 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends.

N/A

1.4t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2020 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-11 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends.

N/A

1.4t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2021 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5122-6 1pc 20mm X 5ft X Single leg sling c/w soft eye at both ends. N/A 5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2022 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-5-12 1pc 13mm X 12ft X Single leg sling c/w soft eye at both ends. N/A 2.5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2023 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PBS 01 1pc 13mm X 12ft X Single leg sling c/w soft eye at both ends. N/A 2.5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2024 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PBS 02 1pc 13mm X 12ft X Single leg sling c/w soft eye at both ends. N/A 2.5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2025 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q1393-17 1pc 20mm X 20ft X Single leg sling c/w soft eye at both ends. N/A 5t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2026 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OPW 151 1pc 22mm X 9.2mtrs X Single leg sling c/w soft eye at both ends. N/A 6.2t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2027 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OSL/PD 234 1pc 28mm X 11ft X Single leg sling c/w soft eye at both ends. N/A 10.1t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2028 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-12 1pc 1 X 10ft X Single leg sling c/w soft eye at both ends. N/A 8t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2029 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-10 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends. N/A 6t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2030 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-6 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends. N/A 6t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2031 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-7 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends. N/A 6t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2032 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 1594 1pc 16mm X 20ft X Single leg sling c/w soft eye at both ends. N/A 3.3t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2033 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PBS 03 1pc 19mm X 2mtrs X Single leg sling c/w soft eye at both ends. N/A 3t N/A N/A 27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2034 Identification Number Qty

28/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-6 1pc


3

/8X 12ft X Single leg sling c/w soft eye at both ends.

N/A

1.4t

N/A

N/A

27-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 28/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2035 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OPW 290 1pc 22mm X 9.2mtrs X Single leg sling c/w soft eye at both ends. N/A 6.2t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2036 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OPW 202 1pc 22mm X 9.2mtrs X Single leg sling c/w soft eye at both ends. N/A 6.2t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2037 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5130-9 1pc 32mm X 25ft X Single leg sling c/w soft eye at both ends. N/A 14t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2038 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5132-5 1pc 52mm X 25ft X Single leg sling c/w soft eye at both ends. N/A 39t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2039 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5132-4 1pc 52mm X 25ft X Single leg sling c/w soft eye at both ends. N/A 39t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2040 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-2-3 1set 1 X 20ft X 2 legged sling c/w master link one end and the other end shur loc hook. N/A 14t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2041 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5143-5 1set 28mm X 10ft X 4 legged sling c/w quad master link with ferrule secured thimble eye at all ends. N/A 21t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2042 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-1-4 1pc 11/8X 20ft X Single leg sling c/w master link and shur loc hook. N/A 12t N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2043 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5150-02 1pc 38mm X 3.67mtrs X Single leg sling c/w master link and hard eye. N/A 20t N/A N/A 28-06-12

LOCATION: RISER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2044 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5149-01 1pc 38mm X 1.84mtrs X Single leg sling c/w master link and hard eye. N/A 20t N/A N/A 28-06-12

LOCATION: RISER DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2045 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5149-02 1pc 38mm X 1.84mtrs X Single leg sling c/w master link and hard eye. N/A 20t N/A N/A 28-06-12

LOCATION: RISER DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2046 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5144-3 1set 28mm X 5ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 21t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2047 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5144-1 1set 28mm X 5ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 21t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2048 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5143-3 1set 28mm X 10ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 21t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2049 Identification Number Qty

29/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5137-2 1set 28mm X 20ft X 2 legged sling c/w master link assembly with ferrule secured thimble eye at all ends. N/A 14t @ 0 0-45 N/A N/A 28-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 29/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2050 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OSL/PD 235 1pc 28mm X 11ft X Single leg sling c/w soft eye both ends. N/A 10.1t N/A N/A 29-06-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2051 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5130-1 1pc 32mm X 25ft X Single leg sling c/w soft eye both ends. N/A 14t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2052 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5130-12 1pc 32mm X 25ft X Single leg sling c/w soft eye both ends. N/A 14t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2053 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5130-8 1pc 32mm X 25ft X Single leg sling c/w soft eye both ends. N/A 14t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2054 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5131-5 1pc 38mm X 25ft X Single leg sling c/w soft eye both ends. N/A 20t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2055 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5131-1 1pc 38mm X 25ft X Single leg sling c/w soft eye both ends. N/A 20t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2056 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5131-6 1pc 38mm X 25ft X Single leg sling c/w soft eye both ends. N/A 20t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2057 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING AN55955-1 1pc 44mm X 50ft X Single leg sling c/w soft eye both ends. N/A 19.52t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2058 Identification Number Qty

30/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING AN55955-2 1pc 44mm X 50ft X Single leg sling c/w soft eye both ends. N/A 19.52t N/A N/A 29-06-12

LOCATION: RISER DECK PORT AFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2059 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-25 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2060 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-18 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2061 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-5 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2062 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-10 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2063 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-22 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2064 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-6 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2065 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-11 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2066 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-30 1pc 16mm X 9.16mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2067 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PB/SL/04 1set 19mm X 4.56mtrs X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 9.7t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RISER DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2068 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-34 1pc 13mm X 12ft X Single leg sling c/w soft eye both ends. N/A 2.5t N/A N/A 30-06-12

LOCATION: RISER DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2069 Identification Number Qty

31/12/2011 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-6 1pc 1 X 10ft X Single leg sling c/w soft eye both ends. N/A 8t N/A N/A 30-06-12

LOCATION: RISER DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 31/12/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2070 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-23 1pc


5

/8 X 10ft X Single leg sling c/w soft eye both ends.

N/A

3.9t

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2071 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-8 1pc


3

/4 X 30ft X Single leg sling c/w soft eye both ends.

N/A

4.1t

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2072 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-7 1pc


3

/4 X 30ft X Single leg sling c/w soft eye both ends.

N/A

4.1t

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2073 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-3 1pc


5

/8 X 20ft X Single leg sling c/w soft eye both ends.

N/A

3.9t

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2074 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OSL/PD 052 1pc 22mm X 20ft X Single leg sling c/w soft eye both ends. N/A 6.2t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2075 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5129-1 1pc 28mm X 5ft X Single leg sling c/w soft eye both ends. N/A 10t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2076 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 964343-0-7-1 1pc


7

/8 X 8ft X Single leg sling c/w soft eye both ends.

N/A

7.6t

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2077 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-3 1pc 16mm X 9.20mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2078 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1393-31 1pc 16mm X 9.20mtrs X Single leg sling c/w soft eye both ends. N/A 3t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2079 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PB/SL/05 1set 20mm X 1.67mtrs X 2 legged sling c/w hard eye both ends. N/A 6.7t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2080 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING PB/SL/06 1set 20mm X 1.67mtrs X 2 legged sling c/w hard eye both ends. N/A 6.7t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2081 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5124-7 1pc 20mm X 20ft X Single leg sling c/w soft eye both ends. N/A 5t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2082 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OSL/PD 018 1pc 22mm X 20ft X Single leg sling c/w soft eye both ends. N/A 6.2t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2083 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-12 1pc 1 X 20ft X Single leg sling c/w soft eye both ends. N/A 8t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2084 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5122-9 1pc 20mm X 5ft X Single leg sling c/w soft eye both ends. N/A 5t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2085 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-4 1pc 22mm X 10ft X Single leg sling c/w soft eye both ends. N/A 6t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2086 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-10 1pc 1X 10ft X Single leg sling c/w soft eye both ends. N/A 8t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2087 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-1-1 1pc 11/8X 20ft X Single leg sling c/w master link and shur loc hook N/A 12t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2088 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING OSL/PD 232 1pc 28mm X 17ft X Single leg sling c/w soft eye both ends. N/A 10.1t N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2089 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING CPCS/08-002/1 1set TOP LEG: 32mm X 1.66mtrs X Single leg c/w master link BOTTOM LEG: 22mm X 2.81mtrs X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 8t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: MINA FREDERICK Conducting Examination Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2090 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5142-5 1set 20mm X 4ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 10.5t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2091 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5142-1 1set 20mm X 4ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 10.5t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2092 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5142-3 1set 20mm X 4ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends. N/A 10.5t @ 0 0-45 N/A N/A 30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2093 Identification Number Qty

02/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5151-01 1pc 28mm X 1.85mtrs X Single leg sling c/w master link one end, the other hard eye. N/A 10t N/A N/A 01-09-12

LOCATION: PIPE DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 02/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2094 Identification Number Qty

02/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5151-02 1pc 28mm X 1.85mtrs X Single leg sling c/w master link one end, the other hard eye. N/A 10t N/A N/A 01-09-12

LOCATION: PIPE DECK STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 02/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2095 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5142-3 1set 1 X 20ft X 2 legged sling c/w master link and shur loc hook N/A 14t @ 0 0-45 N/A N/A 30-06-12

LOCATION: PIPE DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2096 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-39 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2097 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-12 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2098 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-3 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2099 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-8 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2100 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-29 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2101 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-14 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2102 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-49 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2103 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-44 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2104 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-5 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2105 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-22 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2106 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-9 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2107 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-48 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2108 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-23 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2109 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-15 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2110 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-30 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2111 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-46 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2112 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-26 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2113 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-36 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2114 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-38 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2115 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-20 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2116 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-24 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2117 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-28 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2118 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-40 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2119 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-41 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2120 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-17 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2121 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-43 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2122 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-21 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2123 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2124 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-37 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2125 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-47 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2126 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-42 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2127 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-50 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2128 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-18 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2129 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-2 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2130 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-10 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2131 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-16 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2132 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-19 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2133 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-35 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2134 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-25 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2135 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-13 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2136 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-32 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2137 Identification Number Qty

03/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-8-27 1pc


1

/2 X 12ft X Single leg sling c/w soft eye at both ends

N/A

2.5t

N/A

N/A

02-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 03/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2138 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-1 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2139 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-6 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2140 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-5 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2141 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-4 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2142 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-2 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2143 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-6-3 1pc


3

/4 X 30ft X Single leg sling c/w soft eye at both ends

N/A

4.1t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2144 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-13 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2145 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-28 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2146 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-14 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2147 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-27 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2148 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-26 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2149 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-22 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2150 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-12 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2151 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-4 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2152 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-29 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2153 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-18 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2154 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-21 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2155 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-10 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2156 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-19 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2157 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-9 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2158 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-20 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2159 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-17 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2160 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-24 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2161 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-8 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2162 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-16 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2163 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-5 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2164 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-2 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2165 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-11 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2166 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-7 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2167 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-25 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2168 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-30 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2169 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-1-1 1pc


5

/8 X 20ft X Single leg sling c/w soft eye at both ends

N/A

3.9t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2170 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-6 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2171 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-12 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2172 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-5 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2173 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-10 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2174 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-7 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2175 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-11 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2176 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-4 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2177 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-1 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2178 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-2 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2179 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-8 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2180 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-3 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2181 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-7-9 1pc


7

/16 X 30ft X 8parts braided sling c/w soft eye both ends

N/A

11t

N/A

N/A

03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2182 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5137-5 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other hard eye N/A 14t @ 0 0-45 N/A N/A 03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2183 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5137-1 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other hard eye N/A 14t @ 0 0-45 N/A N/A 03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2184 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5137-3 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other hard eye N/A 14t @ 0 0-45 N/A N/A 03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2185 Identification Number Qty

04/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5137-4 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other hard eye N/A 14t @ 0 0-45 N/A N/A 03-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 04/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2186 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5143-4 1set 28mm X 10ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eye at all ends N/A 21t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2187 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-2-1 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other shur loc hooks N/A 14t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2188 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-2-4 1set 28mm X 20ft X 2 legged sling c/w master link one end and the other shur loc hooks N/A 14t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2189 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-35 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2190 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-32 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2191 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-46 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2192 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-42 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2193 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-18 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2194 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-28 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2195 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-39 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2196 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-41 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2197 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-48 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2198 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-37 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2199 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-16 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2200 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-34 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2201 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-49 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2202 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-36 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2203 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-27 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2204 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-47 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2205 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-21 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2206 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-43 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2207 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-19 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2208 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961699-0-4-50 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2209 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-1 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2210 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-8 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2211 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-45 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2212 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-33 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2213 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 961696-0-4-23 1pc


3

/8 X 12ft X Single leg sling c/w soft eye at both ends

N/A

1.4t

N/A

N/A

04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2214 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-2-1 1pc 11/2 X 15ft X Single leg sling c/w master link and eye hook N/A 21t N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2215 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-2-2 1pc 11/2 X 15ft X Single leg sling c/w master link and eye hook N/A 21t N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2216 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-2-3 1pc 11/2 X 15ft X Single leg sling c/w master link and eye hook N/A 21t N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2217 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963902-0-2-4 1pc 11/2 X 15ft X Single leg sling c/w master link and eye hook N/A 21t N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2218 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5136-5 1set 20mm X 20ft X 2 legged sling c/w master link one end the other master link N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2219 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5135-5 1set 20mm X 15ft X 2 legged sling c/w master link one end the other hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2220 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5136-4 1set 20mm X 20ft X 2 legged sling c/w master link one and hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2221 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5136-2 1set 20mm X 20ft X 2 legged sling c/w master link one end the other hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2222 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5136-3 1set 20mm X 20ft X 2 legged sling c/w master link one end the other hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2223 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5135-3 1set 20mm X 15ft X 2 legged sling c/w master link one end the other hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2224 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5135-1 1set 20mm X 15ft X 2 legged sling c/w master link one end the other hard eyes N/A 7t @ 0 0-45 N/A N/A 04-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2225 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING GLN/18251/07 1pc 22mm X 2.5ft X Single leg sling c/w hard eyes both ends N/A 6.2t N/A N/A 04-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2226 Identification Number Qty

05/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING GLN/18251/09 1pc 22mm X 2.5ft X Single leg sling c/w hard eyes both ends N/A 6.2t N/A N/A 04-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 05/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2227 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-28 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2228 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-31 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2229 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-4 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2230 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-5 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2231 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-35 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2232 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-38 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2233 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-36 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2234 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-37 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2235 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-23 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2236 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-24 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2237 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-39 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2238 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-40 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2239 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-32 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2240 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-33 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2241 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-25 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2242 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-27 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2243 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-20 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2244 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-22 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2245 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-30 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2246 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-34 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2247 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-12 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2248 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-13 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2249 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTC Q 1392-11 1pc 20mm X 9.10mtrs X Single leg sling c/w soft eye both ends N/A 5t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2250 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-13-1 1pc


3

/4 X 5.6 X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2251 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-13-2 1pc


3

/4 X 5.6 X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2252 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-13-3 1pc


3

/4 X 5.6 X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2253 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-13-4 1pc


3

/4 X 5.6 X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2254 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-12-1 1pc


3

/4 X 14ft X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2255 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-12-2 1pc


3

/4 X 14ft X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2256 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-12-3 1pc


3

/4 X 14ft X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2257 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 963690-0-12-4 1pc


3

/4 X 14ft X Single leg sling c/w master link and eye hook

N/A

5.6t

N/A

N/A

05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2258 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-4 1pc 1 X 10ft X Single leg sling c/w master link and eye hook N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2259 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-5 1pc 1 X 10ft X Single leg sling c/w master link and eye hook N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2260 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5127-3 1pc 1 X 10ft X Single leg sling c/w master link and eye hook N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2261 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-80 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2262 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-95 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2263 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-92 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2264 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-82 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2265 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-79 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2266 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-81 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2267 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-85 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2268 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-93 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2269 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-72 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2270 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-97 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2271 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-78 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2272 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-74 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2273 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-89 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2274 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-91 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2275 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-96 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2276 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-94 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2277 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-14 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2278 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-31 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2279 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-49 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2280 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-89 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2281 Identification Number Qty

06/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-98 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 05-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 06/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2282 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-25 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2283 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-8 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2284 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-26 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2285 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-44 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2286 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-52 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2287 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-19 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2288 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-9 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2289 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-63 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2290 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-40 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2291 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-51 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2292 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-67 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2293 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-28 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2294 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-12 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2295 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-11 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2296 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-32 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2297 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-1 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2298 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-34 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2299 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-59 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2300 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-36 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2301 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-83 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2302 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-47 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2303 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-4 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2304 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-7 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2305 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-13 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2306 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-3 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2307 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-2 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2308 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-6 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2309 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-18 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2310 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-24 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2311 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-46 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2312 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-55 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2313 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-21 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2314 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5133-16 1pc 1 X 30ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2315 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-4 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2316 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-2 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2317 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-6 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2318 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-9 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2319 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-10 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2320 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5128-5 1pc 1 X 20ft X Single leg sling c/w soft eye at both ends N/A 8t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2321 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5126-4 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2322 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5126-11 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2323 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5126-5 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2324 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5126-6 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2325 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5126-12 1pc 22mm X 20ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2326 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-2 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2327 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-11 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2328 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-9 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2329 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-12 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

2330 Identification Number Qty

07/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING BTCP 5125-3 1pc 22mm X 10ft X Single leg sling c/w soft eye at both ends N/A 6t N/A N/A 06-07-12

LOCATION: UNDER DECK PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body and MPI on Hook RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 07/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1070 Identification Number Qty

14/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 1 X 30ft X single leg sling c/w soft eyes both ends

BTCP 513335

N/A

8mt PL: 16mt

N/A

N/A

13-07-12

LOCATION: TRANSFER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 14/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1071 Identification Number Qty

14/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING 1 X 30ft X single leg sling c/w soft eyes both ends

BTCP 513373

N/A

8mt PL: 16mt

N/A

N/A

13-07-12

LOCATION: TRANSFER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 14/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1072 Identification Number Qty

14/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING

BTCP 5114-1

12mm X 0.6mtr X single leg sling c/w soft eyes both ends

N/A

2mt PL: 4mt

N/A

N/A

13-07-12

LOCATION: TRANSFER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 14/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-0

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1073 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

963690-0-10-1

19mm X 7ft X single leg sling c/w soft eyes both ends

N/A

5.6 t

N/A

N/A

22-07-12

LOCATION: MOON POOL


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-0

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1074 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

963690-0-10-2

19mm X 7ft X single leg sling c/w soft eyes both ends

N/A

5.6 t

N/A

N/A

22-07-12

LOCATION: MOON POOL


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1075 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING X 6ft X single leg sling c/w soft eyes both ends

963690-0-9-1

N/A

5.6 t

N/A

N/A

22-07-12

LOCATION: MOON POOL


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1076 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

BTCP 5112-3

10mm X 2ft X single leg sling c/w soft eyes both ends

N/A

1.2 t

N/A

N/A

22-07-12

LOCATION: MOON POOL


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1077 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

5201-8

1set

16mm X 6ft X 2 Legged sling c/w O-Ring and thimble eye one end other end thimble eye.

N/A

2.8 t @ 0-450

N/A

N/A

22-07-12

LOCATION: FORWARD PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1078 Identification Number Qty

23/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

5201-7

1set

16mm X 6ft X 2 Legged sling c/w O-Ring and thimble eye one end other end thimble eye.

N/A

2.8 t @ 0-450

N/A

N/A

22-07-12

LOCATION: FORWARD PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1079 Identification Number Qty

25/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

BTCP 5519-5

1pc

16mm X 4ft X Single leg sling c/w Soft eyes at both ends

N/A

3t

N/A

N/A

24-07-12

LOCATION: HELIDECK SERVICE CRANE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 25/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1080 Identification Number Qty

26/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

BTCP 5113-8

1pc

10mm X 4ft X Single leg sling c/w Soft eyes at both ends

N/A

1.2 t

N/A

N/A

25-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 26/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1081 Identification Number Qty

26/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

DK-101006/1

1pc

14mm X 2mtrs X Single leg sling c/w Soft eyes at both ends

N/A

2.3 t

N/A

N/A

25-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 26/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1082 Identification Number Qty

30/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

OSL/PD 238

1pc

28mm X 10ft X Single leg sling c/w Soft eyes at both ends

N/A

10.1 t

N/A

N/A

29-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1083 Identification Number Qty

30/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING

BTCP 5129-2

1pc

28mm X 5ft X Single leg sling c/w Soft eyes at both ends

N/A

10 t

N/A

N/A

29-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 30/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1084 Identification Number Qty

21/01/2012

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING X 12ft X Single leg sling c/w Soft eyes at both ends

961696-0-5-5

1pc

N/A

2.5 t

N/A

N/A

20-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1085 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROS S WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING

BTCP 5122-2

1pc

20mm X 5ft X Single leg sling c/w Soft eyes at both ends

N/A

5 mt PL:10mt

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1086 Identification Number Qty

01/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROS S WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING

BTCP 5120-5

1pc

16mm X 5ft X Single leg sling c/w Soft eyes at both ends

N/A

3mt PL: 6mt

N/A

N/A

30-06-12

LOCATION: RIGGING LOFT PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 01/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1282 Identification Number Qty

20/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Shackle ID: 963902-0-8-4 X 12ft X single leg sling c/w Soft eyes both ends

1pc

N/A

2.5 t

N/A

N/A

19-07-12

LOCATION: MUD PUMP ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling
We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: Pacific Bora

20/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1283 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Shackle ID: SOL/PD/243

1pc

28mm X 8ft X single leg sling c/w Soft eyes both ends

N/A

10.1 t

N/A

N/A

16-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Pacific Drilling
We hereby certify that on inspection. Fit for use Signature of Inspector: Conducting Examination

Address of premises where Test / Examination was held: Pacific Bora

17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of

Name of Inspector: FREDRICK MINA Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1696 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-3-4

1pc

1.1/4 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

15 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1697 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-3-1

1pc

1.1/4 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

15 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1698 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-3-2

1pc

1.1/4 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

15 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1699 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-3-3

1pc

1.1/4 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

15 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1700 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-1-3

1pc

1.1/8 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

12 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1701 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-1-2

1pc

1.1/8 X 20ft X Single leg sling c/w Master Link on one end and shur loc hook on the other end

N/A

12 t

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1702 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5144-4

1set

28mm X 5ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

N/A

21mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1703 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5144-2

1set

28mm X 5ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

N/A

21mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1704 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5144-5

1set

28mm X 5ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

N/A

21mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1705 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-4

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1706 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-6

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1707 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-10

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1708 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-11

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1709 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-5

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1710 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-7

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: UNDER PORT CRANE AFT UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1711 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5133-100

1pc

1 X 30ft X Single leg sling c/w soft eyes at both ends

N/A

8mT

N/A

N/A

07-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1712 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5133-58

1pc

1 X 30ft X Single leg sling c/w soft eyes at both ends

N/A

8mT

N/A

N/A

07-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1713 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-2

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1714 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5130-3

1pc

32mm X 25ft X Single leg sling c/w soft eyes at both ends

N/A

14mT

N/A

N/A

07-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1715 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5145-1

1set

35mm X 30ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

N/A

33.5 mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1716 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5146-5

1set

48mm X 30ft X 4 legged sling c/w quad master link assembly with ferrule secured thimble eyes at all ends

N/A

67 mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1717 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5147-2

1set

Top Leg: 2 X 8ft X Single leg sling c/w hard eye Bottom Leg: 1.3/4 X 5ft X 2 legged sling c/w soft eyes

N/A

37.5 mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1718 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5147-1

1set

Top Leg: 2 X 8ft X Single leg sling c/w hard eye Bottom Leg: 1.3/4 X 5ft X 2 legged sling c/w soft eyes

N/A

37.5 mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1719 Identification Number Qty

08/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5148

1set

Top Leg: 3 X 6mtrs X Single leg sling c/w hard eye Bottom Leg: 2.1/2 X 3mtrs X 2 legged sling c/w soft eyes

N/A

84 mT @ o 0-45

N/A

N/A

07-07-12

LOCATION: UPPER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 08/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1720 Identification Number Qty

12/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5119-4

1pc

16mm X 5ft X Single leg sling c/w soft eyes at both ends

N/A

3 mT

N/A

N/A

11-07-12

LOCATION: BOSUNS STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1721 Identification Number Qty

12/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5112-4

1pc

10mm X 2ft X Single leg sling c/w soft eyes at both ends

N/A

1.2 mT

N/A

N/A

11-07-12

LOCATION: BOSUNS STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 12/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1722 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: OSL/PD 242

1pc

28mm X 8ft X Single leg sling c/w soft eyes at both ends

N/A

10.1 t

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1723 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5123-11

1pc

20mm X 10ft X Single leg sling c/w soft eyes at both ends

N/A

5mT

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1724 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5123-1

1pc

20mm X 10ft X Single leg sling c/w soft eyes at both ends

N/A

5mT

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1725 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5121-4

1pc

20mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

5mT

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1726 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5122-1

1pc

20mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

5mT

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1727 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5121-3

1pc

20mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

5mT

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1728 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5120-4

1pc

16mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1729 Identification Number Qty

15/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-3-1

1pc

1 X 300ft X Single leg sling c/w hard eyes at both ends

N/A

9.8 t

N/A

N/A

14-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 15/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1730 Identification Number Qty

16/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5113-10

1pc

10mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

1.2 t

N/A

N/A

15-07-12

LOCATION: SUB SEA STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 16/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1731 Identification Number Qty

16/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-1-26

1pc

10mm X 12ft X Single leg sling c/w soft eyes at both ends

N/A

1.4 t

N/A

N/A

15-07-12

LOCATION: SUB SEA STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 16/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1732 Identification Number Qty

16/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 961696-0-5-10

1pc

1/2 X 12ft X Single leg sling c/w soft eyes at both ends

N/A

2.5 t

N/A

N/A

15-07-12

LOCATION: SUB SEA STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 16/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1733 Identification Number Qty

16/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: DIL 101006

1pc

14mm X 2mtrs X Single leg sling c/w soft eyes at both ends

N/A

2.3 t

N/A

N/A

15-07-12

LOCATION: SUB SEA STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 16/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1734 Identification Number Qty

16/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5119-6

1pc

16mm X 4ft X Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

15-07-12

LOCATION: SUB SEA STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 16/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1735 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: Q469721/3

1pc

19mm (6 x 36 IWRC Galv. RHO) x 120mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

5.14 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1736 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: Q469721/4

1pc

19mm (6 x 36 IWRC Galv. RHO) x 120mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

5.14 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1737 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: R26041A

1pc

10mm (50 DB Galv. RHL) x 140mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

1.58 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1738 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: R25654A

1pc

10mm (50 DB Galv. RHL) x 140mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

1.58 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA PORT SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1739 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: R46721/1

1pc

19mm (6 x 36 IWRC Galv. RHO) x 120mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

5.14 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1740 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: Q469721/2

1pc

19mm (6 X 36 IWRC Galv. RHL) x 120mtrs X Single leg sling c/w closed spelter socket on one end and other end fused and tapered

N/A

5.14 t

N/A

N/A

16-07-12

LOCATION: MOON POOL AREA STBD


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1741 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-6-1

1pc

7/8 x 17 x Single leg sling c/w soft eyes at both ends

N/A

7.6 t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1742 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-6-2

1pc

7/8 x 17 x Single leg sling c/w soft eyes at both ends

N/A

7.6 t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1743 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-4-1

1pc

7/8 x 17 x Single leg sling c/w soft eyes at both ends

N/A

7.6 t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1744 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-4-2

1pc

7/8 x 17 x Single leg sling c/w soft eyes at both ends

N/A

7.6 t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1745 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-8-4

1pc

1/2 x 12 x Single leg sling c/w soft eyes at both ends

N/A

2.5 t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1746 Identification Number Qty

17/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-8

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

16-07-12

LOCATION: HEAVY TOOL STORE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 17/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1747 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-1

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1748 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-3

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1749 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-5

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1750 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5110-3

1pc

16mm x 4ft x Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1751 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: CER 001

1pc

18mm x 2mtrs x Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1752 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: DK 101006

1pc

14mm x 2mtrs x Single leg sling c/w soft eyes at both ends

N/A

2.3 t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1753 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5118-2

1pc

12mm x 10ft x Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

20-07-12

LOCATION: CENTER ENGINE ROOM


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1754 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: OSL/PD 241

1pc

28mm x 10ft x Single leg sling c/w soft eyes at both ends

N/A

10.1 t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1755 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 963902-0-1-15

1pc

5/8 x 20ft x Single leg sling c/w soft eyes at both ends

N/A

3.9 t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1756 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-5-1

1pc

7/8 x 11 x Single leg sling c/w soft eyes at both ends

N/A

7.6 t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1757 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5126-5

1pc

22mm x 20ft x Single leg sling c/w soft eyes at both ends

N/A

6t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1758 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: OPW 137

1pc

22mm x 9.2mtrs x Single leg sling c/w soft eyes at both ends

N/A

6.2 t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1759 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: AOS 712

1pc

19mm x 28ft x Single leg sling c/w soft eyes at both ends

N/A

4.3 t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1760 Identification Number Qty

21/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5133-10

1pc

1 x 30ft x Single leg sling c/w soft eyes at both ends

N/A

8t

N/A

N/A

20-07-12

LOCATION: RIG FLOOR


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 21/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1761 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-12

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

21-07-12

LOCATION: PIPE DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1762 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5114-4

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

21-07-12

LOCATION: PIPE DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1763 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-4

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

21-07-12

LOCATION: PIPE DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1764 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-2

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

21-07-12

LOCATION: PIPE DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1765 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5116-11

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

21-07-12

LOCATION: PIPE DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1766 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 4351-1

1set

5/8 x 6ft x 2 legged sling c/w O Ring one end the other hard eyes.

N/A

2.8 t @ o 0-45

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1767 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 4351-2

1set

5/8 x 6ft x 2 legged sling c/w O Ring one end the other hard eyes.

N/A

2.8 t @ o 0-45

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1768 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5133-68

1pc

1 x 30ft x Single leg sling c/w soft eyes at both ends

N/A

8t

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1769 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5133-84

1pc

1 x 30ft x Single leg sling c/w soft eyes at both ends

N/A

8t

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1770 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 5201-5

1set

5/8 x 6ft x 2 legged sling c/w O Ring one end the other hard eyes.

N/A

2.8 t @ o 0-45

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1771 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 5201-6

1set

5/8 x 6ft x 2 legged sling c/w O Ring one the other hard eye.

N/A

2.8 t @ o 0-45

N/A

N/A

21-07-12

LOCATION: RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1772 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 963902-0-8-1

1pc

1/2 x 12ft x Single leg sling c/w soft eyes at both ends

N/A

2.5 t

N/A

N/A

21-07-12

LOCATION: RIGGING LOFT RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1773 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: PB/SL/08

1set

20mm x 1.5mtrs x 2 legged sling c/w master link assembly

N/A

5.6 t @ o 0-45

N/A

N/A

21-07-12

LOCATION: RIGGING LOFT RISER DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1774 Identification Number Qty

22/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5120-6

1pc

16mm x 5ft x Single leg sling c/w soft eyes at both ends

N/A

3t

N/A

N/A

21-07-12

LOCATION: UPPER DECK STBD SIDE


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1775 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5123-8

1pc

20mm x 10ft x Single leg sling c/w soft eyes at both ends

N/A

5t

N/A

N/A

21-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 22/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1776 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5121-2

1pc

20mm x 4ft x Single leg sling c/w soft eyes at both ends

N/A

5t

N/A

N/A

22-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1777 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5121-1

1pc

20mm x 4ft x Single leg sling c/w soft eyes at both ends

N/A

5t

N/A

N/A

22-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1778 Identification Number Qty

23/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5122-10

1pc

20mm x 5ft x Single leg sling c/w soft eyes at both ends

N/A

5t

N/A

N/A

22-07-12

LOCATION: MOON POOL AREA


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 23/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1779 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5114-5

1pc

12mm x 2ft x Single leg sling c/w soft eyes at both ends

N/A

2t

N/A

N/A

23-07-12

LOCATION: PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1780 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: PB/SL/09

1set

18mm x 1.7mtrs x 2 legged sling c/w hard eyes at all ends

N/A

5.8 t @ o 0-45

N/A

N/A

23-07-12

LOCATION: PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1781 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: PB/SL/10

1pc

26mm x 3.4mtrs x 2 legged sling c/w master link

N/A

9.8 t @ o 0-45

N/A

N/A

23-07-12

LOCATION: PIPE DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1782 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: 964343-0-1-1

1pc

7/8 x 10ft x Single leg sling c/w soft eyes at both ends

N/A

9.8 t

N/A

N/A

23-07-12

LOCATION: REMOVABLE COMPLETION DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1783 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: PB/SL/11

1set

7/8 x 10ft x 2 legged sling c/w hard eyes

N/A

7.15 t @ o 0-45

N/A

N/A

23-07-12

LOCATION: REMOVABLE COMPLETION DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

1784 Identification Number Qty

24/01/2012 Description of Equipment

FREDRICK MINA TARE WT SWL

LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Examination

WIRE ROPE SLING Sling #: BTCP 5113-6

1pc

10mm x 4ft x Single leg sling c/w soft eyes at both ends

N/A

1.2 t

N/A

N/A

23-07-12

LOCATION: REMOVABLE COMPLETION DECK


SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection fit for use.

Name and address of equipment owner: Pacific Drilling

Address of premises where Test / Examination was held: Pacific Bora

We hereby certify that on 24/01/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: MINA FREDERICK Conducting: Exam only