midas Gen SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Cads File Name ASD.spf
* MASS GENERATION DATA FOR LATERAL ANALYSIS OF BUILDING [UNIT: kN, m]
_________________________________________________________
STORY TRANSLATIONAL MASS ROTATIONAL CENTER OF MASS
NAME (X-DIR) (Y-DIR) MASS (X-COORD) (Y-COORD)
----------- ----------- ----------- ----------- ----------- -----------
Roof 46.2195993 46.2195993 912.813835 7.39219435 6.01789006
1F 98.0641645 98.0641645 2355.65182 6.56678147 5.57798995
B1 0.0 0.0 0.0 0.0 0.0
----------- ----------- ----------- ----------- ----------- -----------
TOTAL : 144.283764 144.283764
* ADDITIONAL MASSES FOR THE CALCULATION OF EQUIVALENT SEISMIC FORCE
_____________________________________________________________________
Note. The following masses are between two adjacent stories or on the
nodes released from floor rigid diaphragm by *Diaphragm Disconnect command.
The masses are proportionally distributed to upper/lower stories according
to their vertical locations. For dynamic analysis, however, floor masses
and masses on vertical elements remain at their original locations.
STORY TRANSLATIONAL MASS
NAME (X-DIR) (Y-DIR)
-------------- ----------- -----------
Roof 0.0 0.0
1F 0.0 0.0
B1 13.4852405 13.4852405
-------------- ----------- -----------
TOTAL : 13.4852405 13.4852405
* EQUIVALENT SEISMIC LOAD IN ACCORDANCE WITH UNIFORM BUILDING CODE 1997 [UNIT: kN, m]
_____________________________________________________________________________________________
Seismic Zone Factor (Z) : 0.40
Importance Factor (I) : 1.00
Soil Profile Type : SD
Seismic Source Type : A
Closest Distance To Known Seismic Source [km] : 10.00
Near Source Factor, Na (UBC-97 Table 16-S) : 1.00
Near Source Factor, Nv (UBC-97 Table 16-T) : 1.20
Seismic Coefficient, Ca (UBC-97 Table 16-Q) : 0.44
Seismic Coefficient, Cv (UBC-97 Table 16-R) : 0.77
Fundamental Period Associated With X-dir. (Tx) : 0.2222
R Factor of Lateral System for X-direction (Rx) : 6.0000
Seismic Coefficient for X-dir. UBC-97(Para.1630.2.1) : 0.183333
Fundamental Period Associated With Y-dir. (Ty) : 0.2222
R Factor of Lateral System for Y-direction (Ry) : 6.0000
Seismic Coefficient for Y-dir. UBC-97(Para.1630.2.1) : 0.183333
Total Effective Weight For X-dir. Seismic Loads (Wx) : 1414.846587
Total Effective Weight For Y-dir. Seismic Loads (Wy) : 1414.846587
Scale Factor For X-directional Seismic Loads : 1.00
Scale Factor For Y-directional Seismic Loads : 0.00
Accidental Eccentricity For X-direction (Ex) : None
Accidental Eccentricity For Y-direction (Ey) : None
Modeling, Integrated Design & Analysis Software Print Date/Time : 04/19/2025 12:21
http://www.MidasUser.com
Gen 2024 -1/3-
midas Gen SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Cads File Name ASD.spf
Torsional Amplification for Accidental Eccentricity : Do not Consider
Torsional Amplification for Inherent Eccentricity : Do not Consider
Total Base Shear Of Model For X-direction : 259.388541
Total Base Shear Of Model For Y-direction : 0.000000
Summation Of Wi*Hi Of Model For X-direction : 5791.035531
Summation Of Wi*Hi Of Model For Y-direction : 0.000000
--------------------------------------------------------------------------------------
===========================
ECCENTRICITY RELATED DATA
===========================
X - D I R E C T I O N A L L O A D Y - D I R E C T I O N A L L O A D
STORY ACCIDENTAL INHERENT ACCIDENTAL INHERENT ACCIDENTAL INHERENT ACCIDENTAL INHERE
NT
NAME ECCENT. ECCENT. AMP.FACTOR AMP.FACTOR ECCENT. ECCENT. AMP.FACTOR AMP.FA
CTOR
---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ------
----
Roof 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
1F 0.0 0.0 1.0 0.0 0.0 0.0 1.0
0.0
---------------------------------------------------------------------------------------------------
----
---------------------------------------------------------------------------------------------------
----
The accidental amplification factors are automatically set to 1.0 when torsional amplification effe
ct
to accidental eccentricity is not considered.
The inherent amplification factors are automatically set to 0 when torsional amplification effect
to inherent eccentricity is not considered.
The inherent amplification factors are all set to 'the input value - 1.0'.(This is to exclude the t
rue
inherent torsion)
---------------------------------------------------------------------------------------------------
----
** Story Force , Seismic Force x Scale Factor + Added Force
S E I S M I C L O A D G E N E R A T I O N D A T A X - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 453.2294 6.2 125.8648 0.0 125.8648 0.0 0.0 0.0 0.0
0.0
1F 961.6172 3.1 133.5237 0.0 133.5237 125.8648 390.1809 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 259.3885 1194.285 --- --- --
-
---------------------------------------------------------------------------------------------------
----
Modeling, Integrated Design & Analysis Software Print Date/Time : 04/19/2025 12:21
http://www.MidasUser.com
Gen 2024 -2/3-
midas Gen SEIS LOAD CALC.
PROJECT TITLE :
Company Client
Author Cads File Name ASD.spf
S E I S M I C L O A D G E N E R A T I O N D A T A Y - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 453.2294 6.2 125.8648 0.0 0.0 0.0 0.0 0.0 0.0
0.0
1F 961.6172 3.1 133.5237 0.0 0.0 0.0 0.0 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 0.0 0.0 --- --- --
-
---------------------------------------------------------------------------------------------------
----
=================================================
COMMENTS ABOUT TORSION
=================================================
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity * Amp. Factor for Accidental Eccentricit
y
Inherent Torsion , Story Force * Inherent Eccentricity * Amp. Factor for Inherent Eccentricity
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are not considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity
Inherent Torsion , 0
---------------------------------------------------------------------------------------------------
----
The inherent torsion above is the additional torsion due to torsional amplification effect.
The true inherent torsion is considered automatically in analysis stage when the seismic force is
applied to the structure.
---------------------------------------------------------------------------------------------------
----
Modeling, Integrated Design & Analysis Software Print Date/Time : 04/19/2025 12:21
http://www.MidasUser.com
Gen 2024 -3/3-