Comflor 80/1.2/S350 Bs 5950 Parts 4, 6 and 8 Page 1 of 6
Comflor 80/1.2/S350 Bs 5950 Parts 4, 6 and 8 Page 1 of 6
FULL OUTPUT
SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations
DECK PROFILE:
Sagging Inertia, Ixx 213.000 cm4/m Area of profile (Net), Ap 1864 mm²/m
Hogging Inertia, Iyy 203.000 cm4/m
COMPOSITE:
Inertia, Ixx - Uncracked 2296 cm4/m Cracked 1186 cm4/m
Average inertia 1741 cm4/m Cracked inertia (dynamic) 1354 cm4/m
Shear bond coefficients - Mr 104.19 Kr 0.049200
Concrete volume 0.104 m³/m/m
FIRE DATA :
Design method SIMPLE Fire resistance period 30 mins
Non-permanent imposed loads 2.9 kN/m²
CONSTRUCTION STAGE
SAGGING:
Max applied moment is at 1.41 m from support in longer span
Max applied moment = 5.98 kNm/m
Moment resistance, Mc = 18.49 kNm/m
UNITY FACTOR = 0.32 PASS
HOGGING:
Max. applied moment = 6.13 kNm/m
Moment resistance, Mc = 14.59 kNm/m
UNITY FACTOR = 0.42 PASS
DEFLECTION CHECK :
Allowable deflection ðmax, is the lesser of
1) Effective span/180 (= 18.6 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 15.0 mm )
Max. deflection is at 1.41 m from support in longer span.
Max. self weight deflection = 5.41 mm
( < 15.00 mm ) SATISFACTORY
***NOTE: Deflection within code limits; ponding is not considered
NORMAL STAGE
EFFECTIVE SPAN :
Effective span Le, is the smaller of
1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 3.27 + 150 / 1000 - 45.01 / 1000
= 3.37 m
Therefore Le = 3.37 m
DEFLECTION CHECK :
Allowable deflection ðmax-i under imposed loads, is the lesser of
DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
Dynamic inertia (cracked section) = 1354 cm4
Maximum deflection = 0.013 * 5.67 * (3.37* 1000 )^4 / (205*13540940 )/1000
= 3.49 mm
Frequency = 18 / √ 3.49 )
= 9.64 Hz ( > 5.00 Hz) SATISFACTORY