0% found this document useful (0 votes)
85 views2 pages

Blower Curve

The document provides technical specifications for the G-BH 1 N side channel blower equipped with IE3 motors, including performance curves for both vacuum and compressor operations. It details the blower's capabilities, including suction capacity, power consumption, and temperature rise of conveyed air, under specified conditions. Additionally, it includes selection and ordering data, motor specifications, and compliance with UL and CSA standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views2 pages

Blower Curve

The document provides technical specifications for the G-BH 1 N side channel blower equipped with IE3 motors, including performance curves for both vacuum and compressor operations. It details the blower's capabilities, including suction capacity, power consumption, and temperature rise of conveyed air, under specified conditions. Additionally, it includes selection and ordering data, motor specifications, and compliance with UL and CSA standards.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

G-BH 1 N

Data sheet 2BH1 610


Side channel blower with IE3-motors

Performance curves

Vacuum operation Compressor operation

450
400 50 Hz 50 Hz
60 Hz 1 1 60 Hz
350 2
2 3
300
4
Suction capacity V [m³/h]

250 3 1 5
1
200 2
4 5 2 3
150
4
100
4 5 3 5
50
0
500 400 300 200 100 000 200 400 600 800

Vacuum Total pressure difference p [mbar] Pressure


10,0
9,0
5
8,0 4
4 5
7,0
3 5
6,0
4 5 2 3 4
5,0
Power consumption P

2
1
4,0
at pump shaft [kW]

1
3 3
3,0
2 2
2,0
1 1
1,0
0,0
500 400 300 200 100 00 200 400 600 800
0

Vacuum Total pressure difference p [mbar] Pressure


140
4 5 4 5 5
120
3 5
100
4
80
3
2 3 4
Temperature rise T

60
of conveyed air [K]

1 2
40
2 1 3
20 2
1 1
0
500 400 300 200 100 00 200 400 600 800
0

Vacuum Total pressure difference p [mbar] Pressure

The performance curves are based on air at a temperature of 15 °C and an Every G-BH pump can be used both as vacuum pump and compressor in
atmospheric pressure of 1013 mbar with a tolerance of ± 10 %. The total continuous operation over the total performance curve range. The motors
pressure differences are valid for suction and ambient temperature up to are available as standard in protection category IP 55 and insulation class
25 °C. For other conditions please get in touch with us. F. The vacuum pumps / compressors are UL and CSA approved.

 Gardner Denver Deutschland GmbH Technical data sheet - Edition 05/2018


T
.
Selection and ordering data
Type
No. Fre- Rated Max. differential Sound
quency pressure 2) Efficiency Weight
pres. 4)
1) Level
3) class approx. Order No.
Voltage Current Power Vacuum Pressure
Hz V A kW mbar dB(A) kg
3~ 50/60 Hz, IP55, Insulation material class F, UL (certificate number E489378)
50 190-210  9,9  2,5 -170 160 73 IE3
1 60 190-210  / 380-420  12,0  / 6,0  3,0 -130 120 75 IE3 55 2BH1610-1HK11
60 200  12,0  3,0 -130 120 75 NP
50 190-210  13,3  3,45 -270 260 73 IE3
2 60 190-210  / 380-420  15,2  / 7,6  4,0 -230 200 75 IE3 60 2BH1610-1HK21
60 200  15,2  4,0 -230 200 75 NP
50 190-210  17,1  4,6 -400 360 73 IE3
3 60 190-210  / 380-420  19,6  / 9,8  5,3 -350 320 75 IE3 67 2BH1610-1HK31
60 200  19,6  5,3 -350 320 75 NP
50 190-210  23,5  6,3 -420 530 73 IE3
4 60 190-210  / 380-420  27,6  / 13,8  7,3 -440 490 75 IE3 77 2BH1610-1HK41
60 200  27,6  7,3 -440 490 75 NP
50 190-210  30,8  8,6 -420 610 73 IE3
5 60 190-210  / 380-420  35,2  / 17,6  9,9 -440 670 75 IE3 88 2BH1610-1HK51
60 200  35,2  9,9 -440 670 75 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL (certificate number E489378)
50 220-240  / 380-420  8,6  / 5,0  2,5 -170 160 73 IE3
1 60 220-240  / 440-480  10,4  / 5,2  3,0 -130 120 75 IE3 55 2BH1610-1HK16
60 230  / 460  10,4  / 5,2  3,0 -130 120 75 NP
50 220-240  / 380-420  11,6  / 6,7  3,45 -270 260 73 IE3
2 60 220-240  / 440-480  13,2  / 6,6  4,0 -230 200 75 IE3 60 2BH1610-1HK26
60 230  / 460  13,2  / 6,6  4,0 -230 200 75 NP
50 220-240  / 380-420  14,9  / 8,6  4,6 -400 360 73 IE3
3 60 220-240  / 440-480  17,0  / 8,5  5,3 -350 320 75 IE3 67 2BH1610-1HK36
60 230  / 460  17,0  / 8,5  5,3 -350 320 75 NP
50 220-240  / 380-420  20,4  / 11,8  6,3 -420 530 73 IE3
4 60 220-240  / 440-480  24,0  / 12,0  7,3 -440 490 75 IE3 77 2BH1610-1HK46
60 230  / 460  24,0  / 12,0  7,3 -440 490 75 NP
50 220-240  / 380-420  26,8  / 15,5  8,6 -420 610 73 IE3
5 60 220-240  / 440-480  30,6  / 15,3  9,9 -440 670 75 IE3 88 2BH1610-1HK56
60 230  / 460  30,6  / 15,3  9,9 -440 670 75 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL 1(certificate number E489378)
50 500  4,0  2,5 -170 160 73 IE3
1 55 2BH1610-1HQ13
60 575  4,1  3,0 -130 120 75 NP
50 500  5,4  3,45 -270 260 73 IE3
2 60 2BH1610-1HQ23
60 575  5,3  4,0 -230 200 75 NP
50 500  6,9  4,6 -400 360 73 IE3
3 67 2BH1610-1HQ33
60 575  6,8  5,3 -350 320 75 NP
50 500  9,5  6,3 -420 530 73 IE3
4 77 2BH1610-1HQ43
60 575  9,6  7,3 -440 490 75 NP
50 500  12,4  8,6 -420 610 73 IE3
5 88 2BH1610-1HQ53
60 575  12,2  9,9 -440 670 75 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL (certificate number E489378)
50 380-420  / 660-725  5,0  / 2,90  2,5 -170 160 73 IE3
1 60 440-480  5,2  3,0 -130 120 75 IE3 55 2BH1610-1HQ17
60 460  5,2  3,0 -130 120 75 NP
50 380-420  / 660-725  6,7  / 3,85  3,45 -270 260 73 IE3
2 60 440-480  6,6  4,0 -230 200 75 IE3 60 2BH1610-1HQ27
60 460  6,6  4,0 -230 200 75 NP
50 380-420  / 660-725  8,6  / 5,0  4,6 -400 360 73 IE3
3 60 440-480  8,5  5,3 -350 320 75 IE3 67 2BH1610-1HQ37
60 460  8,5  5,3 -350 320 75 NP
50 380-420  / 660-725  11,8  / 6,8  6,3 -420 530 73 IE3
4 60 440-480  12,0  7,3 -440 490 75 IE3 77 2BH1610-1HQ47
60 460  12,0  7,3 -440 490 75 NP
50 380-420  / 660-725  15,5  / 8,9  8,6 -420 610 73 IE3
5 60 440-480  15,3  9,9 -440 670 75 IE3 88 2BH1610-1HQ57
60 460  15,3  9,9 -440 670 75 NP

1) In case of frequency converter operation the standard motor insulation system is suitable for converter input voltages up to 500 V.

2) Relief valves available for limiting differential pressure.

3) Measuring surface sound pressure level acc. to EN ISO 3744, measured with an equivalent unit at a distance of 1 m. The pump is throttled to an average suction pressure, with piping
connected, but no relief valves fitted, tolerance ±3 dB (A).

2) The motors according to NEMA MG1-12. NP=NEMA Premium; NEMA Premium includes IE3.

All G-BH match the 2006/42/EC (machinery) and 2006/95/EC (low voltage) directives and the EN 60034 norm “Rotating electrical machines”.

Service factor (SF) and motor efficiency according NEMA MG1-12.


Voltage tolerances for three phase motors are +/-10%.
The frequency tolerance is +/- 2 % maximum.

Motor for alternate voltages


Voltage range
Wirkungs-
grad
50 Hz 60Hz 60 Hz 2BH1…-1. □ . □

3~

200 V 200 V YY / 230 V / 400 VY


• K 1
190-210 V  VYY220-240 V / 380-420VY

200 V YY / 230 V / 400 VY 230 V YY / 460 VY


• K 6
 VYY220-240 V / 380-420VY 220-240 VYY / 440-480VY

Q 3
475-525 V Y 550-600 V Y •

475-525 V 550-600 V • Q 5

400 V / 690 V Y 460 V • Q 7

Changes in particular of the quoted performance curve, data and weights may occur without prior notice. The data given does not constitute an obligation from our side to deliver as shown.

Elmo Rietschle is a brand of Gardner Denver Gardner Denver Deutschland GmbH Gardner Denver Schopfheim GmbH
Industriestraße 26 Roggenbachstraße 58
97616 Bad Neustadt - Germany 79650 Schopfheim - Germany
Tel.: +49 9771 6888-0 Tel.: +49 7622 392-0
Fax: +49 9771 6888-4000 Fax: +49 7622 392-300
Your Ultimate Source for Vacuum and Pressure www.gd- ▪ [email protected]